Records from 2000 to 2018. Most recent: inspection, 30 May 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
30 May 2018
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6428840
26 March 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6375957
1 August 2017
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6227004
7 December 2015
ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5776524
16 November 2010
MARPOL Annex V Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3892241
11 November 2010
ISPS II Exam · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3889818
19 July 2007
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2998247
14 July 2007
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2996931
1 December 2005
ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2543863
27 March 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2320880
11 February 2005
Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2290940
1 August 2004
PII Safety Exam · ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2151843
7 September 2003
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1899666
7 August 2003
Annual Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1868084
29 July 2003
Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1860395
22 April 2002
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1607844
20 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1073627
24 August 2001
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 293171
18 April 2000
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 276902
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 July 2007
Resolved
Emergency Generator F/O day tank remote operated vavle not functioning.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 18 May 2009
Resolution: Cleared to the satisfaction of class and checked during Port State Control Examination.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 July 2007
Resolved
Escape trunk fire door auto closer disabled.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 18 May 2009
Resolution: Cleared to the satisfaction of class and checked during Port State Control Examination.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 17 July 2007
Resolved
Door to steering room does not self close, and has hold backs installed.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 18 May 2009
Resolution: Cleared to the satisfaction of class and checked during Port State Control Examination.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 17 July 2007
Resolved
Fire detection system in Engine Room not functioning properly, (FAULT). Repair and Test to the satisfaction of Class. Vessel to provide live engine room watch until repaired.
Action required: 705 - Other - as specified
Due 18 August 2007
Resolved 18 May 2009
Resolution: Cleared to the satisfaction of class and checked during Port State Control Examination.
Fire Fighting › Firemans Outfit
Issued 7 August 2003
Resolved
Provide one firemans outfit, I.A.W. SOLAS 74 (amended) II-2/17.1.1
Action required: 15 - Rectify deficiencies by next port
Resolved 7 September 2003
Resolution: 2 firemans outfits were shown
Construction/Loadline › Markings
Issued 7 August 2003
Resolved
Permanently mark vessels loadline I.A.W. ILLC 66 annex I/9. LEGACY COMPONENT DESC: Load Line Mark
Action required: 15 - Rectify deficiencies by next port
Resolved 7 September 2003
Resolution: loadline was clearly marked
Lifesaving
Issued 24 August 2001
Resolved
Missing one Tin can opener. 3 required, only two where in Lifeboat. Corrected on the Spot
Condition: Unknown
Due 24 August 2001
Resolved 27 August 2001
Documentation
Issued 24 August 2001
Resolved
3 Oil Discharge placards were missing.
Condition: Unknown
Due 24 August 2001
Resolved 29 August 2001