9 July 2026
Deficiency Check · Administrative Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8434049
10 March 2026
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8308226
16 September 2024
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8003694
21 August 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7773708
4 April 2023
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7660514
13 July 2022
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7505749
12 July 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7517324
4 January 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7375335
1 February 2021
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7133947
6 January 2021
Internal Structural Exam · Drydock Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7120283
28 October 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6843836
23 October 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6840571
22 August 2018
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6519468
14 August 2018
Hull Examination · Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6518159
24 October 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6293839
16 November 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6042892
8 November 2016
Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6029951
19 January 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5799731
5 November 2015
Administrative Inspection · Internal Structural Exam · Damage Survey · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5758208
2 November 2015
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5756011
2 November 2015
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5793808
15 September 2010
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3849727
22 October 2008
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3349238
22 September 2008
Examination of Repairs · Damage Survey · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3330285
11 October 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3087602
7 September 2007
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3052081
7 June 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2954633
31 May 2007
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2952621
12 October 2006
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2799914
16 August 2005
Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2501396
1 September 2004
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2183269
5 August 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2156519
1 July 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2219944
27 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1995122
11 December 2003
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1962401
12 November 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1946582
3 November 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1940947
26 August 2002
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1666447
7 November 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366648
15 August 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406775
16 September 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416965
31 July 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466539
27 August 1997
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380974
12 September 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377832
11 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088044
29 April 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087196
1 August 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088046
1 August 1995
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392270
18 October 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370940
29 May 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 145100
10 August 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358130
20 August 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414074
1 October 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248463
7 August 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1250652
24 June 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904868
19 July 1990
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239229
8 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204525
24 October 1988
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205263
7 October 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 886911
10 August 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1339230
30 July 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1000966
20 August 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987195
18 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283099
11 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273565
13 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970121
14 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966192
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2024
Resolved
Each hydraulic system must be provided with arrangements to maintain the cleanliness of the hydraulic fluid appropriate to the type and design of the hydraulic system. Steering system had hydraulic water leak into it.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2024
Resolution: Vsl provided photo documentation showing that hydraulic tank was clear of water.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 October 2024
Resolved
All items of lifesaving equipment shall be examined to determine that they are in suitable condition. Rescue platform does not fully extend near the water and grating has broken and is exposed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2024
Resolution: Vessel modified rescue platform to allow for it to be placed flush with the water. Sufficient photo documentation was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 1 October 2024
Resolved
Electrical installations on vessels shall be such that services essential for safety of passengers, crew, and vessel from electrical hazards. Exposed junction box under pilothouse control station.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 October 2024
Resolution: Master installed a cover over the exposed junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 1 October 2024
Resolved
The general construction of the vessel shall be such as to minimize fire hazards. Gap where the exhaust connects to the stack missing lagging and several electrical cables are in the close knit vicinity.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 October 2024
Resolution: Vessel rep sent in a photograph of extra lagging added to the missing gap on exhaust pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2024
Resolved
Misc. machinery alarms shall be installed in accordance with subchapter J. STBD generator float switch is installed, but not operable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 October 2024
Resolution: Vessel rep sent in a photograph of a new operable float switch.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2024
Resolved
Each fire hydrant shall be identified in red letters and figures at least two inches high " FIRE STATION NO. 1,2,3". Fire extinguishers were labeled fire stations and fire stations were labeled fire hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 October 2024
Resolution: Vessel rep provided inspection team with pictures showcasing the proper markings for fire stations and portable fire extinguishers.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 September 2024
Resolved
A person may not employ or engage an individual and an individual may not serve in a postition in which a TWIC is required without holding the necessary credential. A person may not employ or engage an individual in a position required to hold an MMC unless individual maintains a current medical certificate. Master did not have a current medical certificate. Other potential master did not have a valid TWIC.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 October 2024
Resolution: Vessel master had valid medical certificate and licensed mate had valid TWIC card.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 16 September 2024
Resolved
Each cargo ship equipped with a readiotelephone station must carry a radio operator who holds a marine radio operator permit. Master did not have a marine radio operator permit.
47 CFR 80.161(c)(2)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 October 2024
Resolution: Master had valid Marine Radio Operator Permit.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 April 2023
Resolved
All vessels shall have efficient guard rails or bulwarks on decks, and at exposed peripheries of the superstructure, the rails shall be in at least three courses of 39.5"; vessel superstructure used as a muster area did not have rail. Replace rails at next drydocking.
46 CFR 92.25-5 (a) (Old "I")
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 1 October 2024
Resolution: Veseel rep installed two rows of chain on the aft deck muster area to establish railing at three courses of 39.5".
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 April 2023
Resolved
Each life float must be secured to the vessel by a painter and a float-free link; vessel's two (02) lifefloats were attached by one painter and float-free link.
46 CFR 94.15-10(d) (Old "I")
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2023
Resolved 11 April 2023
Resolution: Received photo evidence of corrected installation.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 April 2023
Resolved
Vessels must carry adequate and up-to-date charts; vessel completed corrections for periodic inspection but had not completed chart corrections since the previous inspection.
46 CFR 97.05-05 (Old "I")
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2023
Resolution: Charts corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 April 2023
Resolved
A heat resistant durable type wiring diagram of each motor controller shall be permanently attached to the inside of the controller door; motor controller found to be missing wiring diagram.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2023
Resolved 11 April 2023
Resolution: Wiring diagram replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 July 2022
Resolved
Except in an emergency situation, no repairs or alterations to the hull, machinery or other equipment that affects the safety of the vessel may be made prior to notice to the cognizant OCMI.
M/V CHRIS R was involved in a grounding and has undetermined amount of damage to the port shaft and/or propeller. Vessel representative must coordinate with MSU Houma once vessel is out of the water and prior to making any repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2022
Resolved 9 August 2022
Resolution: All repairs completed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2021
Resolved
46CFR91.27-1 Your vsl must undergo an annual inspection with in the 3 months before of after eachanniversary date. Vsl was due for its annual inspection 29 AUG and could conduct inspectionuntil 29NOV. Vsl failed to have annual insp prior to 3 months past anniversary date.
Action required: 10 - Deficiency Rectified
Due 1 February 2021
Resolved 1 February 2021
Resolution: Vessel scheduleded and inspection and conducted a new COI
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 1 February 2021
Resolved
Life Floats shall be stowed in such a manner that they are in a float free arrangement and easily released; vsl had incorrect week link attached for combined capacity of life floats; had a rated 11-20 week link and needed at least a rated weak link for 24.
Old I-46CFR94.15-10c
Action required: 10 - Deficiency Rectified
Due 1 February 2021
Resolved 1 February 2021
Resolution: Vsl replaced weak line to account for current capacity of life floats
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 28 October 2019
Resolved
VESSEL WAS NOT KEEPING A RADIO LOG IAW 47 CFR 80.409.
Action required: 10 - Deficiency Rectified
Due 29 October 2019
Resolved 29 October 2019
Resolution: [name withheld] TO BEGIN PROPER LOGGING.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 October 2019
Resolved
MMSI NUMBER ENTERED IN AIS DID NOT MATCH THAT OF FCC DOCUMENTS ASSIGNING VESSEL'S MMSI.
33 CFR 164.46
Action required: 10 - Deficiency Rectified
Due 29 October 2019
Resolved 29 October 2019
Resolution: VESSEL INFORMATION IN AIS WAS UPDATED AND VERIFIED TO BE ACCURATE BY VESSEL REP.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 28 October 2019
Resolved
LIFE FLOATS' GRABLINES WERE DRYROTTED, (01) PADDLE WAS BROKEN, AND FLOATS' BODIES HAD MINOR CRACKING; PROVIDE PROOF OF LIFEFLOAT SERVICING.
46 CFR 199.640(j)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: Lifefloats and paddles were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 October 2019
Resolved
HYDROSTATIC RELEASE UNIT AND HOUSING FOR EPIRB WERE DAMAGED AND DID NOT ALLOW FOR PROPER RELEASE OF EPIRB; HOUSING AND HYDROSTATIC RELEASE UNIT MUST BE REPLACED SUCH THAT THE EPIRB MAY FLOAT FREE AS DESIGNED.
46 CFR 199.510(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: Housing replaced and hydrostatic release unit properly installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 October 2019
Resolved
EMBARKATION STATION, BRIDGE, AND MAIN DECK BY DOOR EXITING TO BACK DECK ALL DISPLAYED INSUFFICIENT POWER TO BATTERY-POWERED EMERGENCY LIGHT; BATTERIES REQUIRED REPLACEMENT.
46 CFR 112.39
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: Batteries were replaced and lights were all verified to have sufficient brightness.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 October 2019
Resolved
REPLACE CRACKED DISCHARGE HOSE ON PORTABLE CO2 FIRE EXTINGUISHER IN ENGINE ROOM.
46 CFR 95.01-2(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: Unit serviced and in satisfactory condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 October 2019
Resolved
PROPERLY ADJUST ENGINE ROOM EMERGENCY ESCAPE HATCH TO ENSURE WATERTIGHT INTEGRITY.
46 CFR 91.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 25 November 2019
Resolution: Hatch adjusted to properly ensure watertight integrity.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 28 October 2019
Resolved
OVERHEAD IN ENGINE ROOM ABOVE STBD SHAFT HAD PINHOLE LEAK; MAKE WELD REPAIRS TO THE DECK/OVERHEAD TO ENSURE WATERTIGHT INTEGRITY.
46 CFR 91.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: Pinhole leak welded and repaired to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2019
Resolved
EMERGENCY FUEL SHUTOFF VALVES DID NOT FULLY CLOSE WHEN ACTUATED FROM REMOTE STATION; MUST BE ADJUSTED TO ENSURE FULL CLOSURE OF THE VALVES.
46 CFR 56.50-60(d)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: MI witnessed testing of valves; satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 October 2019
Resolved
ELECTRICAL GROUND FAULT WAS DETECTED ON SWITCHBOARD INDICATOR; ISOLATE AND MAKE REPAIRS TO REMOVE GROUND.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: Ground identified and corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 October 2019
Resolved
WATERTIGHT DOORS LEADING TO INTERIOR OF MAIN DECK AND ENGINE ROOM HAD IMPROPERLY INSTALLED GASKETS; CREW TO INSTALL GASKETS CORRECTLY TO ENSURE WATERTIGHT INTEGRITY.
46 CFR 170.270(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 25 November 2019
Resolution: Gasket replaced properly to ensure watertight integrity.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 28 October 2019
Resolved
EXCESS OIL ACCUMULATED IN BILGE PRESENTS POTENTIAL HAZARD; PROPERLY REMOVE AND DISPOSE THE OIL FROM THE ENGINE ROOM BILGES.
46 CFR 91.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2019
Resolved 12 November 2019
Resolution: Bilges satisfactorily cleaned to mitigate hazards.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 8 November 2016
Resolved
Port and Starboard packing needs to be replaced. Excessive leaking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 16 November 2016
Resolution: Repacked port and starboard packing, sat.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 8 November 2016
Resolved
Vessel's transfer procedures were not adequeately written in accordance with the regs.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 16 November 2016
Resolution: Vessel generated new transfer procedures, reviewed and approved in compliance with CFR.
Engineering › Compressed Air System (start air) › Valve
Issued 8 November 2016
Resolved
Relief valve for upper PV needed to be tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 16 November 2016
Resolution: Provided new releif valve with documentation, tested sat.
Construction/Loadline › Hull › Bottom Plating
Issued 5 November 2015
Resolved
complete hull repairs IAW worklist prior to sail
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2016
Resolution: witnessed sat air test of all repairs
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 2 November 2015
Resolved
Rudder angle indicator was not working.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2015
Resolved 3 November 2015
Resolution: Tech arrived and made repairs to damaged wire.
Construction/Loadline › Hull › Hull Plating
Issued 2 November 2015
Resolved
Fore peak significantly damaged and holed due to allisiont with platform. PTP to be issued.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2015
Resolved 3 November 2015
Resolution: PTP issued for transit to Port Fourchon area.
Lifesaving › Lifefloat › Painter
Issued 2 November 2015
Resolved
Painter for lifefloats was wrapped around structure of vessel and would not float free if needed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2015
Resolved 3 November 2015
Resolution: Painter was reinstalled.
Lifesaving › Lifebuoys › Stowage
Issued 2 November 2015
Resolved
Lifebuoy was not stowed in an easily releasable manner.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 2 November 2015
Resolved 3 November 2015
Resolution: Lifeline was redone removing issue being easily releasable.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 15 September 2010
Resolved
Provide Waste Management Plan for vessel
Action required: 705 - Other - as specified
Resolved 16 September 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 September 2010
Resolved
replace inop not under command light
Action required: 705 - Other - as specified
Resolved 16 September 2010
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 15 September 2010
Resolved
Repair inop rudder angle indicator
Action required: 705 - Other - as specified
Resolved 16 September 2010
Engineering › Thrusters › Shaft
Issued 15 September 2010
Resolved
Tailshafts leaking excessively with steady stream. Repair leak and double nut.
Action required: 705 - Other - as specified
Resolved 16 September 2010
Electrical › Electric Supply System (service) › Cable
Issued 15 September 2010
Resolved
Provide metal straps not more then 24" apart for all cables in e/r.
Action required: 705 - Other - as specified
Resolved 16 September 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 September 2010
Resolved
Remove all deadend wires in e/r
Action required: 705 - Other - as specified
Resolved 16 September 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 September 2010
Resolved
Provide E-light for ladder well on main deck to bridge
Action required: 705 - Other - as specified
Resolved 16 September 2010
Fire Fighting › Fire Pumps › Pressure
Issued 15 September 2010
Resolved
Demonstrate proper pressure of fire pump.
Action required: 705 - Other - as specified
Resolved 16 September 2010
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 11 October 2007
Resolved
Remove plastic sight glass and replace with approved sight glass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 11 October 2007
Resolved
Repair emergency light at top of stairway going to machinery spaces.
Action required: 705 - Other - as specified
Due 11 November 2007
Resolved 12 October 2007
Construction/Loadline › Hull › Hull Plating
Issued 31 May 2007
Resolved
Vessel breached hull at port transome and placed doubler over 3 inch hole.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2007
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 31 May 2007
Resolved
Vessel did not report marine casualty for the hole in the port transome.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2007
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 31 May 2007
Resolved
Vessel failed to submit CG-2692
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 May 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 31 May 2007
Resolved
Renew all E/R emergency lighting
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 31 May 2007
Resolved
Renew lagging on stbd exhaust piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 October 2006
Resolved
Wiring not properly supported or protected in cableways
Action required: 705 - Other - as specified
Resolved 19 October 2006
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 12 October 2006
Resolved
excessive oil in bilges
Action required: 705 - Other - as specified
Resolved 19 October 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 12 October 2006
Resolved
no homeport listed on any liferings
Action required: 705 - Other - as specified
Resolved 19 October 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 October 2006
Resolved
Wiring of pilot house console in complete disarray. Wiring not supported, exposed bare wiring, cut wires not terminated properly,
Action required: 705 - Other - as specified
Resolved 19 October 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 12 October 2006
Resolved
Multiple broken fixtures in engineeroom & mechanical spaces
Action required: 705 - Other - as specified
Resolved 19 October 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 October 2006
Resolved
e-light out in vestibule to engineroom, e-light on bridge missing
Action required: 705 - Other - as specified
Resolved 19 October 2006
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 October 2006
Resolved
Liftraft launching/embarkation station missing e-light
Action required: 705 - Other - as specified
Resolved 19 October 2006
Fire Fighting › Nozzles › Condition
Issued 12 October 2006
Resolved
Fire monitor system dissassembled for determination of problems / repair
Action required: 705 - Other - as specified
Resolved 19 October 2006
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 12 October 2006
Resolved
grease trap and flame screens for ventilation hood missing
Action required: 705 - Other - as specified
Resolved 19 October 2006
Documentation › Certificates/Documents › FCC SSL
Issued 12 October 2006
Resolved
Bridge to Bridge radio cert expired
Action required: 705 - Other - as specified
Resolved 19 October 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 12 October 2006
Resolved
Inspection terminated due to excessive discrepancies. Vessel to be in compliance w/ applicable sections 46 CFR subchapter "I" and all applicable supporting subchapters of "I".
Action required: 705 - Other - as specified
Resolved 19 October 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 October 2006
Resolved
Several unplugged through holes in fwd engineroom watertight bulkhead. Plug all holes to make bulkhead watertight
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 16 November 2006
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 October 2006
Resolved
F/O stripping valves located in fwd engineroom not capped. Install caps on valves
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 16 November 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 12 October 2006
Resolved
Cable runs in engineering spaces (engine room / machine space) not properly supported in overhead. Piping is not proper supporting structure. Install cable hangers and banding to support cable.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 16 November 2006
Construction/Loadline › Structures › Deck Plating
Issued 12 October 2006
Resolved
Deck under sewage tank excessively corroded. Move sewage tank, clean deck, and make determination for further repairs if required.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 16 November 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 October 2006
Resolved
Longitudinal hull stiffener located portside, fwd machine space, outboard sewage tank. Stiffener wasted, crop and renew.
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 16 November 2006
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 12 October 2006
Resolved
Properly repair or replace exhaust vent and flamescreen over galley stove
Action required: 705 - Other - as specified
Due 19 November 2006
Resolved 16 November 2006
Engineering › Bilge Water Management System › Piping
Issued 16 August 2005
Resolved
Install skin valve and pipe brackets to installed bilge ovbd piping.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2005
Resolved 26 October 2006
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 16 August 2005
Resolved
Provide engine temp gauges at the operating station.
Action required: 705 - Other - as specified
Due 16 October 2005
Resolved 19 October 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2005
Resolved
replace broken lighting fixture, fwd port berthing compartment.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 October 2005
Resolved 19 October 2006
Navigation › Piloting/Steering › Azimuth
Issued 5 August 2004
Resolved
Rudder angle indicator inoperable.
Action required: 705 - Other - as specified
Due 5 September 2004
Resolved 1 September 2004
Resolution: Crew replaced old unit with a new unit.
Construction/Loadline
Issued 12 November 2003
Resolved
Provide stern freeboard marks per vessel stability letter.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Engineering
Issued 12 November 2003
Resolved
Provide bilge high level alarm in rudder space.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Navigation › Piloting/Steering › Azimuth
Issued 12 November 2003
Resolved
Provide operational rudder angle indicator.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 5 August 2004
Navigation
Issued 12 November 2003
Resolved
Provide NAVTEX weather reciever for unlimited route.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Lifesaving
Issued 12 November 2003
Resolved
Provide emergency light at life float embarkation area.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Engineering
Issued 12 November 2003
Resolved
Provide engine room vent closures.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Fire Fighting
Issued 12 November 2003
Resolved
Provide marine type fire ext. brackets.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Engineering
Issued 12 November 2003
Resolved
Remove positive stop valves or provide PRV's in air compressor discharge piping.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Fire Fighting
Issued 12 November 2003
Resolved
Remove/repair temporary patch in fire pump discharge piping and flex hose, make permenant repairs.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Engineering
Issued 12 November 2003
Resolved
Repair/replace excessive slack in steering idler chains.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Pollution Prevention/Response
Issued 12 November 2003
Resolved
Provide mud basket strainer for bilge pump suction.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 9 December 2003
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 12 November 2003
Resolved
Provide fire safety plan for approval.
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 5 August 2004
Electrical › Lighting (service)
Issued 26 August 2002
Resolved
PROVIDE MISSING BREAKER BLANKS FOR ENGINE ROOM AND PILOT HOUSE BREAKER PANELS. LEGACY COMPONENT DESC: PANEL
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 October 2002
Resolved 5 September 2002
Electrical › Electrical Distribution System (service)
Issued 26 August 2002
Resolved
PROVIDE AND INSTALL NON-CONDUCTIVE GRAB BAR ON MAIN SWITCH BOARD. LEGACY COMPONENT DESC: NON-CONDUCTIVE GRAB BAR
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 October 2002
Resolved 5 September 2002
Engineering › Diesel Engine (auxiliary) › Valve
Issued 26 August 2002
Resolved
REPAIR OR RENEW STARBOARD GENERATOR FUEL OIL SUPPLY VALVE.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 4 October 2002
Resolved 5 September 2002