Records from 1981 to 2002. Most recent: inspection, 23 August 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
23 August 2002
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1665286
25 October 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376778
6 September 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361678
10 April 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1050560
29 September 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1468094
1 September 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396984
24 September 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375163
27 September 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457390
9 March 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 43407
12 October 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360274
4 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 136422
2 November 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456209
15 December 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370750
11 November 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 131397
23 June 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354374
17 December 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453992
10 November 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 136300
20 February 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1259151
21 February 1991
COI Inspection · Hull Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1231288
8 May 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 911764
26 September 1989
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1350522
10 May 1989
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 896877
19 May 1988
COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1200792
19 January 1988
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1013649
23 June 1987
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1005597
15 August 1986
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007937
12 August 1985
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 985065
12 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984245
14 August 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972801
16 August 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967188
24 August 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1275082
15 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272216
31 August 1981
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1277726
Lifesaving › Lifebuoys › Stowage
Issued 29 August 2002
Resolved
ARRANGE LIFERINGS FOR QUICK RELEASE.
Due 29 September 2002
Resolved 6 September 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 29 August 2002
Resolved
INSTALL GUARD FOR RANGE HOOD LIGHT. LEGACY COMPONENT DESC: RANGE HOOD
Due 29 September 2002
Resolved 6 September 2002
Lifesaving › Buoyant Apparatus
Issued 29 August 2002
Resolved
RESTENCIL LIFEFLOATS. LEGACY COMPONENT DESC: LABELING
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2002
Resolved 6 September 2002
Stability › Watertight Integrity
Issued 29 August 2002
Resolved
ADJUST ALL WATERTIGHT DOORS. LEGACY COMPONENT DESC: WATERTIGHT DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2002
Resolved 6 September 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 29 August 2002
Resolved
SERVICE CO2 ON PAINT LOCKER.
Due 29 September 2002
Resolved 6 September 2002
Engineering
Issued 29 September 1999
Resolved
Prove proper operation of starboard pressure vessel relief valve and pressure guage.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 29 September 1999
Resolved
Properly install watertight fitting for electrical cable passing though aftwatertight bulkhead of engineroom.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 29 September 1999
Resolved
Properly seal hole in watertight bulkhead at the forward end of the engineroom above the watertight door. Hole was drilled to allow passage of speaker wire.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Navigation
Issued 1 September 1998
Resolved
PROVIDE UPDATED DEVIATION TABLE.
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Navigation
Issued 1 September 1998
Resolved
PROVIDE LARGE SCALE CHART OF INTRACOASTAL CITY (NOS CHART 11349)._x001C_
Condition: Unknown
Due 2 September 1998
Resolved 2 September 1998
Fire Fighting
Issued 14 August 1984
Resolved
MAKE PERMANENT REPAIRS AND SERVICE V BC(150 LB) DRY CHEMICAL FIRE EXTINGUISHER.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984
Lifesaving
Issued 14 August 1984
Resolved
PROVIDE ILLUSTRATED LIFE JACKET DONNING INSTRUCTIONS IN PASSENGER SPACES. THESE REQUIREMENTS ARE TO BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMIU.S. COAST GUARD PRIOR TO CARRYING FLAMMABLE OR HAZARDOUS CARGO. NLT 1SEP84FOR ITEM 1, AND NLT 15SEP84 FOR ITEM 2
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984