MAURY USCG vessel records Sign in
← All vessels

NANA HOPE

NANA HOPE is a 1979 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 1982, most recently in January 2001, along with 39 deficiencies.

Records from 1982 to 2001. Most recent: inspection, 19 January 2001.

Built
1979
Last inspected
19 January 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCP2313
Flag
UNITED STATES
—
Maury page id
psix-50394

Inspections, by type

…with no type recorded6
Years with a record 16 calendar years (1982–2001)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it15 - Regulatory (Subpart C or D), Net Ton
22 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCP2313MMSI not assigned · expired · voluntarily equipped · granted 2 December 1994, cancelled 5 February 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

19 January 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 825348
11 December 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 813634
29 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812331
26 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812330
22 November 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812327
29 October 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 812326
22 October 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361174
15 March 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 806028
29 January 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381457
27 November 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 805360
16 October 1998 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368892
6 November 1997 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1119339
17 October 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1368443
19 November 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359299
23 October 1996 Re-Inspection · Drydock Extension · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1405988
24 November 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357393
18 October 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1385561
2 December 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1405628
6 October 1994 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380072
4 November 1990 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1230096
16 October 1990 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 918564
27 June 1989 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1206350
3 June 1989 Hull Examination
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1351724
1 November 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891933
4 November 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1026590
10 November 1986 Re-Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323626
23 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293056
14 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286226
16 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972348
28 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273725

Deficiency record · 39

Electrical
Issued 22 October 1999 Resolved
Remove or repair lighting fixtures in the engine compartment iaw 46CFR 183.410.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 22 October 1999 Resolved
Repair cabin lighting iaw 46CFR 183.410.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 22 October 1999 Resolved
Install audible and visual bilge high level alarm iaw 46CFR 182.530.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Navigation
Issued 22 October 1999 Resolved
Post emergency broadcast placard where it is readily readable from radio location iaw 46CFR 184.506.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Navigation
Issued 22 October 1999 Resolved
Acquire current USCG Light List (excerpt) and tide tables/tide calendar iaw46CFR 184.420.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Documentation
Issued 22 October 1999 Resolved
Complete FCC inspection and acquire current FCC Safety Radio Certificate.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 22 October 1999 Resolved
Place (2) flashlights on vessel to satisfy requirements for portable lighting iaw 46CFR 183.432.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Navigation
Issued 22 October 1999 Resolved
Repair night illumination on installed magnetic compass iaw 46CFR 184.402.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 22 October 1999 Resolved
Clean or replace battery which shows corrosion at the terminals.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 22 October 1999 Resolved
Document quarterly training held for crew iaw 46CFR 185.420.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Fire Fighting
Issued 22 October 1999 Resolved
Replace broken valve handle to fire (garden) hose spigot on main deck iaw 46CFR 181.310.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Engineering
Issued 22 October 1999 Resolved
Replace rusted connection on fuel tank fuel return lines iaw 46CFR 182.455.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Navigation
Issued 22 October 1999 Resolved
Repair installed (generator operated), ship's whistle, or provide other suitable device iaw 33CFR 86.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Lifesaving
Issued 22 October 1999 Resolved
Replace damaged buoyant apparatus with approved lifefloat iaw 46CFR 180.200(a)(2).
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 22 October 1999 Resolved
Replace (3) of (6) expired orange smoke distress signals with approved signals iaw 46CFR 180.68.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 22 October 1999 Resolved
Demonstrate proper operation of installed generator, or remove and permanantly seal generator through-hull fittings. Replace labelplate. Generator must operate iaw 46CFR 183.320.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 22 October 1999 Resolved
Post lifejacket donning procedures where best seen iaw 46CFR 185.516.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 22 October 1999 Resolved
Replace condemned ring life buoy. Remount in a location where ring buoy will not be gouged by hatch latch. Place iaw 46CFR 180.70.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Electrical
Issued 22 October 1999 Resolved
Replace wire nut beneath pilothouse console with proper pressure type connector iaw 46CFR 183.330.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Lifesaving
Issued 22 October 1999 Resolved
Install Cat I 406MHz EPIRB iaw 46CFR 180.64.
Condition: Unknown
Due 22 October 1999
Resolved 22 October 1999
Construction/Loadline
Issued 29 January 1999 Resolved
Steel bitts installed into aluminum deck forward, port and starboard are galvanically reacting and show moderate corrosion. Repair or replace bittsto the satisfaction of an attending marine inspector.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Lifesaving
Issued 16 October 1998 Resolved
Found water light was not properly attached to ring buoy. Required water light be attached IAW 46 CFR 180.70 (d)(2)&(3).
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Electrical
Issued 16 October 1998 Resolved
Found A/C unit and Battery Charger were being provided electrical power by a temporary wiring installation. Required hard wiring of A/C system and Battery Charger including the provision of overcurrent protection IAW 46 CFR 183.380.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Lifesaving
Issued 17 October 1997 Resolved
Renew retroreflective tape on both lifefloats as per 46 CFR 160.010-3(p).
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Construction/Loadline
Issued 17 October 1997 Resolved
Provide one portable manual bilge pump as per 46 CFR 182.520.
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Lifesaving
Issued 17 October 1997 Resolved
Replace lifeline on bottom lifefloat serial #63 37 9 as per 46 CFR 160.010-3(f).
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Lifesaving
Issued 17 October 1997 Resolved
Provide one additional adult sized life preserver as per 46 CFR 180.71. Passenger capacity reduced to 24 until this deficiency is cleared.
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Electrical
Issued 23 October 1996 Resolved
PROPERLY LABEL ALL ELECTRICAL PANELS.
Condition: Unknown
Due 24 October 1996
Resolved 24 October 1996
Construction/Loadline
Issued 23 October 1996 Resolved
PROPERLY REPAIR ALL CRACKS IN THE HORIZONTAL STRINGER JUST BELOW THE STARBOARD EXHAUST ON THE TRANSOM BULKHEAD IN THE LAZARETTE AND THE BROKEN WELD ALONG THE ENGINE ROOM BULKHEAD HORIZONTAL STRINGER IN THE LAZARETTE.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Construction/Loadline
Issued 18 October 1995 Resolved
Properly label vessel name on stern.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Documentation
Issued 18 October 1995 Resolved
Provide Employee Assistance Program in accordance with 46 CFR 16.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Electrical
Issued 18 October 1995 Resolved
Install guards for light bulbs in main cabin.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Lifesaving
Issued 18 October 1995 Resolved
Install pendants on life float.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Engineering
Issued 18 October 1995 Resolved
Repair lagging on starboard engine exhaust.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Engineering
Issued 18 October 1995 Resolved
Prove operation of vent closures to engine room.
Condition: Unknown
Due 18 October 1995
Resolved 24 October 1995
Engineering
Issued 18 October 1995 Resolved
Conduct operational tests of machinery, steering apparatus and electronic equipment and conduct emergency drills.
Condition: Unknown
Due 18 October 1995
Resolved 24 October 1995
Construction/Loadline
Issued 18 October 1995 Resolved
Prior to carrying passengers for hire clean engine room bilge and machineryof excessive oil.
Condition: Unknown
Due 18 October 1995
Resolved 24 October 1995
Fire Fighting
Issued 18 October 1995 Resolved
Install metallic piping for fire main and bilge systems.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Construction/Loadline
Issued 18 October 1995 Resolved
Label forepeak valve on bilge manifold.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995

Ownership record