Records from 1981 to 2009. Most recent: inspection, 5 May 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 46
5 May 2009
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3467962
12 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3204919
8 May 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3201597
2 May 2007
Hull Examination · Re-Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2924653
24 May 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2657787
24 May 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2657827
13 April 2006
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2623668
26 October 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2522370
16 June 2005
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2392423
26 April 2004
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2053215
2 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979689
28 March 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1764345
6 February 2003
Damage Survey · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1859767
27 August 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1667253
14 May 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1616653
17 April 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362124
3 April 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412076
23 April 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375736
18 May 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388571
20 March 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446464
29 October 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392551
31 August 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427113
29 October 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363131
4 March 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450831
25 August 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395980
21 October 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414095
9 April 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473552
27 August 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936948
27 August 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245493
27 August 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249132
19 May 1991
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904206
19 May 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929068
17 May 1991
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224335
17 August 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238458
31 July 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224158
11 September 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891753
16 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204601
1 February 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210622
15 September 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042567
23 August 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347996
20 August 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308148
31 July 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337660
4 November 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303650
23 October 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974603
30 August 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1272421
2 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277302
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2008
Resolved
Provide updated marine charts suitable for navigating approaches to ports transitted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 May 2008
No resolution recorded
Properly conduct and log required monthly safety drills.
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 May 2008
Resolved
Install a removable safety chain in place of missing section of grab rail leading down into the engine room.
Action required: 705 - Other - as specified
Resolved 9 May 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 May 2008
Resolved
Renew safety latch for vsl's oven in galley.
Action required: 705 - Other - as specified
Resolved 9 May 2008
Lifesaving › Lifebuoys › Serviceable
Issued 8 May 2008
Resolved
Renew retroreflective tape on lifebouys as directed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2008
Navigation › Piloting/Steering › Marine Charts
Issued 24 May 2006
Resolved
Failure to have on board adequate and up to date charts for area of intended voyage.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 24 July 2007
Resolution: New charts for the areas transitted onboard.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 24 May 2006
Resolved
Vessel operated without full compliment required by vessel's certificate of inspection.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 24 July 2007
Resolution: Full compliment onboard.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 24 May 2006
Resolved
Failing to submit sailing short list as required.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 24 July 2007
Engineering › Pressure Vessel › Marking and Stamping
Issued 13 April 2006
Resolved
Pressure Vessel visual inspection was not completed at COI inspection.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 19 May 2006
Engineering › Fuel Oil Service System › Filter
Issued 28 March 2003
Resolved
PROVIDE METALLIC PLUGS FOR ALL RACOR FUEL FILTERS IN ENGINEROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 March 2003
Resolved
LABEL ELECTRICAL PANEL ON MESSDECK.
Due 28 April 2003
Resolved 28 March 2003
Documentation › Safety/Response Plans/Programs
Issued 28 March 2003
Resolved
PROVIDE FIRE SAFETY PLAN TO THE ATTENDING MARINE INSPECTOR FOR APPROVAL. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 28 April 2003
Resolved 5 May 2004
Fire Fighting › Fire Hydrants › Location/Position
Issued 28 March 2003
Resolved
ADJUST DECK FIRE CONNECTION VALVES TO POINT IN THE HORIZONTAL POSITION VERSES THE VERTICAL POSITION.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 March 2003
Resolved
PROVIDE 2002 LIGHT LIST.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Engineering › Steering Gear System › Piping
Issued 28 March 2003
Resolved
REPAIR HYDRAULIC LEAK IN PIPING LOCATED IN RUDDER ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 28 March 2003
Resolved
PROVIDE 250 PSI GAUGES FOR BOTH AIR RECEIVERS.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Engineering › Steering Gear System
Issued 10 February 2003
Resolved
Reweld all broken welds as marked on rudder post & steering gear bracing in rudder room (lazarette).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Side Shell
Issued 10 February 2003
Resolved
Remove epoxy filler & reweld crack between deck & outboard bulkhead of aft starboard cargo tank.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Stiffener
Issued 10 February 2003
Resolved
Reweld deck support angle to overhead in aft starboard cargo tank.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 10 February 2003
Resolved
Reweld stern tube as original to swash bulkhead in starboard aft void.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Engineering › Bilge Water Management System › Piping
Issued 10 February 2003
Resolved
Reinnstall forepeak suction pipe & strainer.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Keel
Issued 10 February 2003
Resolved
Gouge & weld keel bar to main deck where cracked in forepeak.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Stiffener
Issued 10 February 2003
Resolved
Gouge & reweld 10" angle where cracked under main deck centerline in forepeak.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 February 2003
Resolved
Gouge & reweld cracked railpipe on bow gunwale.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 February 2003
Resolved
Install safety retaining chains on all external manhole covers.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 February 2003
Resolved
Provide Marine Chemist Certification that all enclosed spaces & voids are "safe for workers" so that all spaces are available for Coast Guard inspection.
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 10 February 2003
Engineering › Shafting/Propeller Arrangements
Issued 6 February 2003
Resolved
Provide written repair proposal for damage to shafts & rudders.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 10 February 2003
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 February 2003
Resolved
Address pitting on starboard shaft. Provide written report on shaft condition.
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 10 February 2003
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 6 February 2003
Resolved
Submit written report of casualty (CG2692) for grounding/strike that occurred OOB 0300 CST 03FEB03. Casualty occurred in the vicinity of the Brown & Root Dock, Port Aransas, TX. LEGACY COMPONENT DESC: Filing Written Report of Marine Casualty
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 31 July 2003
Resolution: After contacting Burke of KMJ Services, he submitted a CG2692 for the incident.
Lifesaving › Hand Flares › Marking
Issued 14 May 2002
Resolved
DISTRESS FLARES NOT STENCILED ON STORAGE BOX.
Due 18 June 2002
Resolved 19 June 2002
Navigation › Piloting/Steering
Issued 14 May 2002
Resolved
RUDDER ANGLE INDICATOR INOPERABLE. LEGACY COMPONENT DESC: RUDDER ANGLE INDICATOR
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 May 2002
Resolved
PORT MAIN ENGINE TACHOMETER INOPERABLE. LEGACY COMPONENT DESC: PORT TACHOMETER
Due 18 June 2002
Resolved 19 June 2002
Lifesaving › Lifebuoys › Quantity
Issued 14 May 2002
Resolved
MISSING 1 REQUIRED LIFERING.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 14 May 2002
Resolved
FUEL SHUTOFFS NOT PROPERLY STENCILED. LEGACY COMPONENT DESC: MARKING
Due 18 June 2002
Resolved 19 June 2002
Communications › Radio Communications › EPIRB
Issued 14 May 2002
Resolved
EPIRB NOT OPERATIONAL, NEEDS SERVICING.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 May 2002
Resolved
STERN LIGHT NON OPERATIONAL.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Engineering › Diesel Engine (auxiliary)
Issued 14 May 2002
Resolved
PORT GENERATOR LEAKS DIESEL FUEL EXCESSIVELY. LEGACY COMPONENT DESC: FUEL SYSTEM LEAK
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Electrical › Electrical Distribution System (emergency)
Issued 14 May 2002
Resolved
ENGINE ROOM EMERGENCY LIGHTS INOPERABLE. LEGACY COMPONENT DESC: LIGHTS
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 May 2002
Resolved
SWITCHBOARD MISSING ELECTRICAL SAFETY MATTING.
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Construction/Loadline
Issued 17 April 2001
Resolved
PROVIDE PROOF THAT VESSEL WAS CONSTRUCTED TO APPROVED PLANS TO THE OCMI MARINE SAFETY OFFICE MORGAN CITY.
Condition: Unknown
Due 17 July 2001
Resolved 3 May 2001
Lifesaving
Issued 29 October 1996
Resolved
REPLACED WASTED 12 PERSON LIFEFLOAT. TOTAL PERSONS ONBOARD LIMITED TO 12_x001C_ UNTIL SECOND FLOAT IS INSTALLED.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Documentation
Issued 29 October 1996
Resolved
PROVIDE TO MSO MORGAN CITY SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS ESTABLISHED AND IMPLEMENTED A CHEMICAL TESTING PROGRAM AS REQUIRED BY 46CFR PART 16.
Condition: Unknown
Due 29 October 1996
Resolved 29 October 1996
Electrical
Issued 21 October 1992
Resolved
COMPLETE WORKLIST ITEMS #2, 6, & 8 ISSUED AT MID-PERIOD INSPECTION._x001C_ _x001C_ (CG-SEE MINS)
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Construction/Loadline
Issued 17 May 1991
Resolved
MAKE PERMANENT REPAIRS TO APPROX. 12" FRACTURE/PUNCTURE AT CHINE BAR IN_x001C_ WAY OF STBD. SIDE IN ENGINE ROOM.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Navigation
Issued 16 August 1989
Resolved
INSTALL RUDDER ANGLE INDICATOR SYSTEM IN ACCORDANCE WITH 46 CFR 113.4 AS PER 46 CFR 96.05.
Condition: Unknown
Due 16 August 1989
Resolved 16 August 1989