DECATHLON is a 1979 offshore supply vessel. The Coast Guard has recorded 46 inspections since 1981, most recently in May 2009, along with 45 deficiencies — 1 with no resolution recorded —.

Records from 1981 to 2009. Most recent: inspection, 5 May 2009.

Built
1979
Last inspected
5 May 2009
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC7659
Flag
UNITED STATES
367074760 (licence lapsed)
Maury page id
psix-50398

Inspections, by type

…with no type recorded7
Years with a record 27 calendar years (1981–2009)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)106.9 ft × 26.0 ft × 8.0 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCULLY BROS BOAT BUILDNG · STEPHENSVILLE, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLAROSE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC7659MMSI 367074760 · expired · compulsorily equipped · granted 3 November 2005, cancelled 9 January 2016
WCB2684MMSI not assigned · expired · compulsorily equipped · granted 10 August 1998, cancelled 20 December 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 46

5 May 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3467962
12 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3204919
8 May 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3201597
2 May 2007 Hull Examination · Re-Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2924653
24 May 2006 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2657787
24 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2657827
13 April 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2623668
26 October 2005 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2522370
16 June 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2392423
26 April 2004 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2053215
2 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979689
28 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1764345
6 February 2003 Damage Survey · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1859767
27 August 2002 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1667253
14 May 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1616653
17 April 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362124
3 April 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412076
23 April 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375736
18 May 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388571
20 March 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446464
29 October 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392551
31 August 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427113
29 October 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363131
4 March 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450831
25 August 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395980
21 October 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414095
9 April 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473552
27 August 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936948
27 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245493
27 August 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249132
19 May 1991 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904206
19 May 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929068
17 May 1991 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224335
17 August 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238458
31 July 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224158
11 September 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891753
16 August 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204601
1 February 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210622
15 September 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042567
23 August 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347996
20 August 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308148
31 July 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337660
4 November 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303650
23 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974603
30 August 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1272421
2 September 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277302

Deficiency record · 45

Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2008 Resolved
Provide updated marine charts suitable for navigating approaches to ports transitted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2008
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 May 2008 No resolution recorded
Properly conduct and log required monthly safety drills.
Action required: 705 - Other - as specified
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 May 2008 Resolved
Install a removable safety chain in place of missing section of grab rail leading down into the engine room.
Action required: 705 - Other - as specified
Resolved 9 May 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 May 2008 Resolved
Renew safety latch for vsl's oven in galley.
Action required: 705 - Other - as specified
Resolved 9 May 2008
Lifesaving › Lifebuoys › Serviceable
Issued 8 May 2008 Resolved
Renew retroreflective tape on lifebouys as directed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2008
Navigation › Piloting/Steering › Marine Charts
Issued 24 May 2006 Resolved
Failure to have on board adequate and up to date charts for area of intended voyage.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 24 July 2007
Resolution: New charts for the areas transitted onboard.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 24 May 2006 Resolved
Vessel operated without full compliment required by vessel's certificate of inspection.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 24 July 2007
Resolution: Full compliment onboard.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 24 May 2006 Resolved
Failing to submit sailing short list as required.
Action required: 705 - Other - as specified
Due 24 May 2006
Resolved 24 July 2007
Engineering › Pressure Vessel › Marking and Stamping
Issued 13 April 2006 Resolved
Pressure Vessel visual inspection was not completed at COI inspection.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 19 May 2006
Engineering › Fuel Oil Service System › Filter
Issued 28 March 2003 Resolved
PROVIDE METALLIC PLUGS FOR ALL RACOR FUEL FILTERS IN ENGINEROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 March 2003 Resolved
LABEL ELECTRICAL PANEL ON MESSDECK.
Due 28 April 2003
Resolved 28 March 2003
Documentation › Safety/Response Plans/Programs
Issued 28 March 2003 Resolved
PROVIDE FIRE SAFETY PLAN TO THE ATTENDING MARINE INSPECTOR FOR APPROVAL. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 28 April 2003
Resolved 5 May 2004
Fire Fighting › Fire Hydrants › Location/Position
Issued 28 March 2003 Resolved
ADJUST DECK FIRE CONNECTION VALVES TO POINT IN THE HORIZONTAL POSITION VERSES THE VERTICAL POSITION.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 March 2003 Resolved
PROVIDE 2002 LIGHT LIST.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Engineering › Steering Gear System › Piping
Issued 28 March 2003 Resolved
REPAIR HYDRAULIC LEAK IN PIPING LOCATED IN RUDDER ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 28 March 2003 Resolved
PROVIDE 250 PSI GAUGES FOR BOTH AIR RECEIVERS.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 April 2003
Resolved 28 March 2003
Engineering › Steering Gear System
Issued 10 February 2003 Resolved
Reweld all broken welds as marked on rudder post & steering gear bracing in rudder room (lazarette).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Side Shell
Issued 10 February 2003 Resolved
Remove epoxy filler & reweld crack between deck & outboard bulkhead of aft starboard cargo tank.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Stiffener
Issued 10 February 2003 Resolved
Reweld deck support angle to overhead in aft starboard cargo tank.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 10 February 2003 Resolved
Reweld stern tube as original to swash bulkhead in starboard aft void.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Engineering › Bilge Water Management System › Piping
Issued 10 February 2003 Resolved
Reinnstall forepeak suction pipe & strainer.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Keel
Issued 10 February 2003 Resolved
Gouge & weld keel bar to main deck where cracked in forepeak.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Construction/Loadline › Hull › Stiffener
Issued 10 February 2003 Resolved
Gouge & reweld 10" angle where cracked under main deck centerline in forepeak.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 February 2003 Resolved
Gouge & reweld cracked railpipe on bow gunwale.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 February 2003 Resolved
Install safety retaining chains on all external manhole covers.
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 16 February 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 6 February 2003 Resolved
Provide Marine Chemist Certification that all enclosed spaces & voids are "safe for workers" so that all spaces are available for Coast Guard inspection.
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 10 February 2003
Engineering › Shafting/Propeller Arrangements
Issued 6 February 2003 Resolved
Provide written repair proposal for damage to shafts & rudders.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 10 February 2003
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 6 February 2003 Resolved
Address pitting on starboard shaft. Provide written report on shaft condition.
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 10 February 2003
Operations/Management › Casualty Reporting/Post-Casualty Actions
Issued 6 February 2003 Resolved
Submit written report of casualty (CG2692) for grounding/strike that occurred OOB 0300 CST 03FEB03. Casualty occurred in the vicinity of the Brown & Root Dock, Port Aransas, TX. LEGACY COMPONENT DESC: Filing Written Report of Marine Casualty
Action required: 705 - Other - as specified
Due 10 February 2003
Resolved 31 July 2003
Resolution: After contacting Burke of KMJ Services, he submitted a CG2692 for the incident.
Lifesaving › Hand Flares › Marking
Issued 14 May 2002 Resolved
DISTRESS FLARES NOT STENCILED ON STORAGE BOX.
Due 18 June 2002
Resolved 19 June 2002
Navigation › Piloting/Steering
Issued 14 May 2002 Resolved
RUDDER ANGLE INDICATOR INOPERABLE. LEGACY COMPONENT DESC: RUDDER ANGLE INDICATOR
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 May 2002 Resolved
PORT MAIN ENGINE TACHOMETER INOPERABLE. LEGACY COMPONENT DESC: PORT TACHOMETER
Due 18 June 2002
Resolved 19 June 2002
Lifesaving › Lifebuoys › Quantity
Issued 14 May 2002 Resolved
MISSING 1 REQUIRED LIFERING.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 14 May 2002 Resolved
FUEL SHUTOFFS NOT PROPERLY STENCILED. LEGACY COMPONENT DESC: MARKING
Due 18 June 2002
Resolved 19 June 2002
Communications › Radio Communications › EPIRB
Issued 14 May 2002 Resolved
EPIRB NOT OPERATIONAL, NEEDS SERVICING.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 May 2002 Resolved
STERN LIGHT NON OPERATIONAL.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Engineering › Diesel Engine (auxiliary)
Issued 14 May 2002 Resolved
PORT GENERATOR LEAKS DIESEL FUEL EXCESSIVELY. LEGACY COMPONENT DESC: FUEL SYSTEM LEAK
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Electrical › Electrical Distribution System (emergency)
Issued 14 May 2002 Resolved
ENGINE ROOM EMERGENCY LIGHTS INOPERABLE. LEGACY COMPONENT DESC: LIGHTS
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2002
Resolved 19 June 2002
Electrical › Electrical Distribution System (service) › Switchboard
Issued 14 May 2002 Resolved
SWITCHBOARD MISSING ELECTRICAL SAFETY MATTING.
Action required: 705 - Other - as specified
Due 18 June 2002
Resolved 19 June 2002
Construction/Loadline
Issued 17 April 2001 Resolved
PROVIDE PROOF THAT VESSEL WAS CONSTRUCTED TO APPROVED PLANS TO THE OCMI MARINE SAFETY OFFICE MORGAN CITY.
Condition: Unknown
Due 17 July 2001
Resolved 3 May 2001
Lifesaving
Issued 29 October 1996 Resolved
REPLACED WASTED 12 PERSON LIFEFLOAT. TOTAL PERSONS ONBOARD LIMITED TO 12_x001C_ UNTIL SECOND FLOAT IS INSTALLED.
Condition: Unknown
Due 4 November 1996
Resolved 4 November 1996
Documentation
Issued 29 October 1996 Resolved
PROVIDE TO MSO MORGAN CITY SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS ESTABLISHED AND IMPLEMENTED A CHEMICAL TESTING PROGRAM AS REQUIRED BY 46CFR PART 16.
Condition: Unknown
Due 29 October 1996
Resolved 29 October 1996
Electrical
Issued 21 October 1992 Resolved
COMPLETE WORKLIST ITEMS #2, 6, & 8 ISSUED AT MID-PERIOD INSPECTION._x001C_ _x001C_ (CG-SEE MINS)
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Construction/Loadline
Issued 17 May 1991 Resolved
MAKE PERMANENT REPAIRS TO APPROX. 12" FRACTURE/PUNCTURE AT CHINE BAR IN_x001C_ WAY OF STBD. SIDE IN ENGINE ROOM.
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Navigation
Issued 16 August 1989 Resolved
INSTALL RUDDER ANGLE INDICATOR SYSTEM IN ACCORDANCE WITH 46 CFR 113.4 AS PER 46 CFR 96.05.
Condition: Unknown
Due 16 August 1989
Resolved 16 August 1989