Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
206 - Regulatory (Subpart C or D), Gross Ton
206 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-50399
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 41
11 September 2025Administrative Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8231802
11 May 2010COI Inspection · MTSA Verification
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3727961
21 May 2009Drydock Exam · Deficiency Check · Cargo Tank Internal · Annual Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3468864
15 December 2008Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3380255
20 May 2008Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3213695
15 May 2007Re-Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2931527
18 September 2006Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2802672
21 July 2006Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2720491
12 May 2006Cargo Tank Internal · Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2651123
9 May 2006Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2646884
25 October 2005Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2521557
25 October 2005Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2521628
18 May 2005COI Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2361525
18 June 2004Re-Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2103199
11 June 2003Hull Examination · Periodic Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1815830
16 July 2002Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1647943
Remove water from both aft voids/rakes. Prove watertight in way of hatch covers and attach chain to hatch cover for all void covers.
Action required: 705 - Other - as specified
Due 21 June 2009
Resolved 1 June 2009
Construction/Loadline › Hull › Hull Plating
Issued 21 May 2009Resolved
Provide gauging report IAW 46CFR 31.10-21(a).
Action required: 705 - Other - as specified
Due 21 June 2009
Resolved 20 June 2009
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 21 May 2009Resolved
Renew painting of vessels name on stern, sides, and draft marks.
Action required: 705 - Other - as specified
Due 21 June 2009
Resolved 1 June 2009
Construction/Loadline › Hull › Bottom Plating
Issued 15 December 2008Resolved
Make vessel ready for hull exam prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2009
Documentation › Certificates/Documents › International Load Line Certificate
Issued 18 September 2006Resolved
Def issued under Activity #2720491.
Action required: 705 - Other - as specified
Due 17 October 2006
Resolved 17 October 2006
Resolution: Upon sat completion of DDX; ABS re-issued Load Line Certificate.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 21 July 2006Resolved
Load Line (ABS) will expired on 31JUL06. Vessel permitted to continue operations from 31JUL06 to 18SEP06 or to the period when the vessel is first Dry-Docked (whichever period comes first) without a load line INSIDE THE BOUNDARY LINE for Unalaska Bay only.
Action required: 705 - Other - as specified
Due 18 September 2006
Resolved 18 October 2006
Resolution: Load line re-issued by ABS...
Install retro-reflective tape in way of both ring buoys.
Due 18 May 2005
Resolved 18 May 2005
Construction/Loadline
Issued 14 July 1999Resolved
INSTALL CHAIN OR CABLE TO HATCH TO PORT FWD RAKE TO PREVENT FROM LOSING OVERBOARD.
Condition: Unknown
Due 20 July 1999
Resolved 22 September 1999
Deck/Cargo
Issued 14 July 1999Resolved
PROVIDE AND INSTALL PLUG TO COAMING DRAIN PORT SIDE AFT.
Condition: Unknown
Due 20 July 1999
Resolved 22 September 1999
Construction/Loadline
Issued 14 July 1999Resolved
PAINT NAME OF BARGE ON BOTH SIDES OF BOW.
Condition: Unknown
Due 20 July 1999
Resolved 22 September 1999
Deck/Cargo
Issued 31 May 1996Resolved
Prove proper operation and emergency shutdown of the cargo pump engine prior to the carriage of cargo
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Lifesaving
Issued 31 May 1996Resolved
Procure/install the appropriate warning and benzene hazard signs on the barge prior to the carriage of cargo
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Deck/Cargo
Issued 31 May 1996Resolved
Procure/install flame on all 4 ullage ports.
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Deck/Cargo
Issued 31 May 1996Resolved
Replace/install gasket material in the tank dome hatch for #2 tank dome
Condition: Unknown
Due 17 June 1996
Resolved 17 June 1996
Documentation
Issued 1 June 1994Resolved
ANNUAL ENDORSEMENT IS OVERDUE ON LOADLINE CERTIFICATE, VESSEL RESTRICTED TOOPERATING WITHIN THE BOUNDRYWATERS UNTIL ANNUAL SURVAY AND ENDORSEMENT HAS BEEN COMPLETED.
Condition: Unknown
Due 20 July 1994
Resolved 20 July 1994
Deck/Cargo
Issued 19 May 1987Resolved
REPAIR OR REPLACE EXHAUST MUFFLER IN CARGO PUMP ENGINE
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Deck/Cargo
Issued 19 May 1987Resolved
REINSTALL EMERGENCY STOP FOR CARGO PUMP AND TEST
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Deck/Cargo
Issued 19 May 1987Resolved
PROVIDE FLAME SCREENS FOR ULLAGE OPENINGS
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Navigation
Issued 19 May 1987Resolved
MOUNT STERN LIGHT AND TEST
Condition: Unknown
Due 19 May 1987
Resolved 19 May 1987
Documentation
Issued 17 June 1986Resolved
PROVIDE FOR THE ANNUAL LOAD LINE ENDORSEMENT
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986