Records from 1981 to 2017. Most recent: inspection, 28 August 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 49
28 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6254106
26 March 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4823839
7 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4240191
20 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4228577
8 July 2011
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4074133
22 November 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3896413
3 February 2010
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3674357
23 December 2009
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3654155
7 January 2009
Re-Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3390878
18 April 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3186930
6 February 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2868367
19 January 2007
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2858413
10 April 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2620984
4 January 2005
Re-Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2273351
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232334
30 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2004041
5 January 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1975092
16 January 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1731227
13 March 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494768
27 April 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379398
2 May 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466682
3 May 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369148
21 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799179
29 November 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183766
30 November 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422605
11 March 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357129
10 March 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366996
25 June 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 484697
10 March 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373801
15 July 1992
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 954627
18 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395861
20 February 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224173
30 August 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922295
21 June 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 518773
18 May 1990
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214095
30 March 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 923936
23 March 1990
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1217989
26 February 1990
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1243106
27 February 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196817
1 August 1988
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033836
18 February 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1336273
20 February 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002319
20 February 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007810
18 February 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995298
15 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291987
29 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280279
13 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973283
12 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273938
20 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966378
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 22 November 2010
Resolved
DOT Alcohol test strips required for minimum number of crew members assigned to vessel.
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 6 December 2010
Resolution: DOT Alcohol Test strips purchased.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 22 November 2010
Resolved
Stuffing box needs to be double nutted.
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 23 November 2010
Resolution: Stuffing box double nutted.
Engineering › Fuel Oil Service System › Hose
Issued 22 November 2010
Resolved
Install a cam-lock on fuel pump to replace hose.
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 23 November 2010
Resolution: Cam-lock installed on fuel pump.
Fire Fighting › Fire Pumps › Pressure
Issued 22 November 2010
Resolved
Fire pump gauge inoperative.
Action required: 705 - Other - as specified
Due 23 December 2010
Resolved 23 November 2010
Resolution: Fire pump gauge replaced.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 February 2010
Resolved
Replace 02 lifejackets prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Construction/Loadline › Structures › Door
Issued 3 February 2010
Resolved
Re-align watertight doors to engine room and house prior to sailing. Doors would not close properly and both had several areas of daylight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Operations/Management › Drills/Instruction › Abandon Ship
Issued 3 February 2010
Resolved
Conduct drills to the satisfaction of attending marine inspector prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2010
Construction/Loadline › Hull › Hull Plating
Issued 7 January 2009
Resolved
Make proper and permanent repairs to damaged port bow area in way of upper forepeake prior to conducting any commercial operations.
Action required: 705 - Other - as specified
Resolved 12 January 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 January 2009
Resolved
Re-route grey water discharge from clothes washer so it does not mix with oily water in e/r bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 January 2009
Electrical › Electrical Distribution System (service) › Panelboard
Issued 7 January 2009
Resolved
Properly label each breaker, panel, motor controller, and electrical box in the e/r.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 January 2009
Resolved
Properly label each emergency escape exit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 7 January 2009
Resolved
Remove all standing oil and oily water mixtures from vsl's bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Engineering › Fuel Oil Service System › Filter
Issued 7 January 2009
Resolved
Install a proper flame bowl and plug on bottom of Racor filter as directed in e/r.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Lifesaving › Lifefloat › Lifeline
Issued 7 January 2009
Resolved
Replace/renew wasted line on one lifefloat and one lifering as directed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Resolution: Renewed lifering and serviced lifefloat.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 January 2009
Resolved
Install safety latches on each fridge, freezer, and oven door to prevent accidental opening in rough weather.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 January 2009
Resolved
Replace/renew each expired or opened eyewash bottle at eye safety stations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2009
Lifesaving › Rescue Boat › Carriage Requirement
Issued 7 January 2009
Resolved
Modify/add safety items to rescue platform as discussed with MI.
Action required: 705 - Other - as specified
Resolved 13 January 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2008
Resolved
Install covers on all lights without protective covers.
Due 18 May 2008
Resolved 14 May 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 April 2008
Resolved
Renew all inoperable smoke detectors.
Due 18 May 2008
Resolved 14 May 2008
Documentation › Markings/Placards › Lifejacket Placard
Issued 18 April 2008
Resolved
Install life jacket donning placard for Kapok life jackets.
Due 18 May 2008
Resolved 14 May 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 18 April 2008
Resolved
Install sufficient emergency lighting for forward engine room compartment, and port bunk room exit.
Due 18 May 2008
Resolved 14 May 2008
Communications › Radio Communications › EPIRB
Issued 18 April 2008
Resolved
Repair lanyard for EPIRB pin mechanism.
Due 18 May 2008
Resolved 14 May 2008
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 18 April 2008
Resolved
Install.
Due 18 May 2008
Resolved 14 May 2008
Engineering › Pressure Vessel › Relief Valve
Issued 18 April 2008
Resolved
Renew pressure vessel relief valve.
Due 18 May 2008
Resolved 14 May 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 April 2008
Resolved
Renew exhaust lagging.
Due 18 May 2008
Resolved 14 May 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2008
Resolved
Install metallic clamp supports on electrical wiring and hoses.
Due 18 May 2008
Resolved 14 May 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 April 2008
Resolved
Install new compass, and provide new compass deviation table.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2008
Stability › Watertight Integrity › General
Issued 18 April 2008
Resolved
Repair hole in watertight gasket for engine room door.
Due 18 May 2008
Resolved 14 May 2008
Navigation › Piloting/Steering › Compass Deviation Table
Issued 18 April 2008
Resolved
Provide with new compass.
Due 18 May 2008
Resolved 2 May 2008
Documentation › Certificates/Documents › FCC SSL
Issued 6 February 2007
Resolved
The radio safety certificate was not present.
Due 28 February 2007
Resolved 13 February 2007
Operations/Management › Drills/Instruction › Safety Orientation
Issued 6 February 2007
Resolved
Required drills, training and monthly EPIRB checks were not being recorded/conducted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Operations/Management › Drills/Instruction › Safety Orientation
Issued 6 February 2007
Resolved
Required passenger safety orientation placards/materials were not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 6 February 2007
Resolved
An emergency broadcast placard was not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Engineering › Freshwater Generation System › Valve, Dump
Issued 6 February 2007
Resolved
The hot water heater had a leaking valve.
Due 28 February 2007
Resolved 13 February 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 February 2007
Resolved
An additional light was required in the engine room for the aft emergency exit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Engineering › Fuel Oil Service System › Piping
Issued 6 February 2007
Resolved
A fuel leak was found near one of the filters on the starboard main diesel engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 6 February 2007
Resolved
Lighting fixtures in the accommodations spaces did not have bulb covers/guards.
Due 28 February 2007
Resolved 13 February 2007
Construction/Loadline › Structures › Door
Issued 6 February 2007
Resolved
The aft door on the crew lounge area had a wasted section around the lip of the door frame.
Due 28 February 2007
Resolved 13 February 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 6 February 2007
Resolved
The emergency exit from the crew accommodation space and engine room was not properly marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 6 February 2007
Resolved
A safety harness for the rescue platform was not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 6 February 2007
Resolved
A mettalic exhaust hose/lint trap assembly was not installed on the dryer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Engineering › Lubricating Oil Service System › Piping
Issued 6 February 2007
Resolved
The lube oil piping was not blanked off at the service end.
Due 28 February 2007
Resolved 13 February 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 6 February 2007
Resolved
The magnetic compass did not illuminate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2008
Construction/Loadline › Structures › Air Pipe
Issued 6 February 2007
Resolved
The engine room vent pipe was severely wasted on the aft deck.
Due 28 February 2007
Resolved 13 February 2007
Engineering › Fuel Oil Service System › Filter
Issued 6 February 2007
Resolved
Flame bowls were not installed on the main diesel engines.
Due 28 February 2007
Resolved 13 February 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 6 February 2007
Resolved
Non conductive matting was not present below the electrical switchboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 February 2007
Resolved
A solid deck was installed on the rescue platform vs. the required open grating.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2007
Documentation › Certificates/Documents › FCC SSL
Issued 10 April 2006
Resolved
Provide FCC station license as required by 47 CFR 80.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 12 June 2006
Resolution: Received faxed copy.
Documentation › Certificates/Documents › FCC SSL
Issued 10 April 2006
Resolved
Provide on board vessel a valid FCC Communications Act Safety Radiotelephony Certificate to the satisfaction of the attending marine inspector as required by 46 CFR 184.502 and 47 CFR 80.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 13 February 2007
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 10 April 2006
Resolved
Provide proof the 50% of the vessel's crew has received first aid and CPR training as required by NVIC 1-91.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 11 April 2006
Resolution: The entire crew provided proof of training.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 April 2006
Resolved
Log EPIRB tests once a month as required by 46 CFR 185.702.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 10 April 2006
Resolution: A log book was started immediately.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 10 April 2006
Resolved
Renew or remove unused deck machinery electrical distribution panel ito the satisfaction of the attending marine inspector in accordance with 46 CFR 183.330.
Action required: 705 - Other - as specified
Due 10 May 2006
Resolved 18 April 2008
Stability › Watertight Integrity
Issued 5 January 2004
Resolved
Repair engine room escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Mechanic brought in to repair hatch during inspection. Worn bushing replaced & lubricated.
Communications › Radio Communications › Emergency Source of Power
Issued 5 January 2004
Resolved
SSB & 1 VHF lack back up power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Technician brought in to install dedicated back up battery & charger. Approved location & materials.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 January 2004
Resolved
Several lights were broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Broken lights replaced.
Fire Fighting › Fire Hydrants › Condition
Issued 5 January 2004
Resolved
Valve on stbd fire station frozen shut.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Valve purchased at local marine hardware store and installed.
Construction/Loadline › Hull
Issued 16 January 2003
Resolved
Crop & Renew wasted deck in rope locker, associated frame members and manhole to rope locker.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2003
Resolution: Repairs completed sat.
Fire Fighting › Ventilation Systems
Issued 13 March 2002
Resolved
Provived covers for engine room ventilation.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2002
Resolution: Covers provided.
Fire Fighting › Nozzles
Issued 13 March 2002
Resolved
Provide 2 each nozzles IAW 46 CFR 181.320
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2002
Resolution: Proper nozzles provided
Electrical › Electric Generation Source (service) › Generator
Issued 13 March 2002
Resolved
Provide metallic drain plugs in RACOR filters as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2002
Resolution: Plugs installed
Engineering › Bilge Water Management System › Piping
Issued 13 March 2002
Resolved
Repair bilge suction pipe.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2002
Resolution: Wasted pipe replaced.
Electrical
Issued 26 February 1990
Resolved
SPLIT-BUS POWER PANEL HAS UNCOVERED BREAKER SLOTS AND OPEN CABLE ENTRY ON TOP THAT NEEDS TO BE SEALED.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Engineering
Issued 26 February 1990
Resolved
RACOR FUEL FILTERS HAVE PETCOCK VALVES ON BOTTOM OF BOWL NOT EQUIPPED WITH CAP OR PLUG AS REQUIRED BY 46CFR182.20-40(B)(7).
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Electrical
Issued 26 February 1990
Resolved
NON-APPROVED AUTOMOTIVE TYPE BATTERY CABLE CLAMPS ON BATTERY CABLES.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990
Deck/Cargo
Issued 26 February 1990
Resolved
HYDRO-TEST DIESEL FUEL TRANSFER HOSES AT 1 1/2 DSTIMES WORKING PRESSURE CERTIFIED BY MANUFACTURER.
Condition: Unknown
Due 26 February 1990
Resolved 26 February 1990