MAURY USCG vessel records
← All vessels

C - RAMBLER

C - RAMBLER is a 1999 offshore supply vessel. The Coast Guard has recorded 18 inspections since 2016, most recently in October 2024, along with 4 deficiencies and 2 casualty investigations between 2021 and 2023.

Records from 2016 to 2024. Most recent: inspection, 31 October 2024.

Built
1999
Last inspected
31 October 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 31 October 2024
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9220251
WDP3610
504187
Flag
UNITED STATES
Maury page id
psix-504187

Documentation record

Registered dimensions (L × B × D)221.6 ft × 56.0 ft × 21.0 ft
Registered tonnagegross 2,092 / net 627
ITC dimensions (L × B × D)221.6 ft × 56.0 ft × 21.0 ft
ITC tonnagegross 2,092 / net 627
BuilderN.AMERICAN FABRICATORS · HOUMA, LA, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 28 March 2026 · expires 30 April 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2092 - Convention (Subpart B), Gross Ton
627 - Convention (Subpart B), Net Ton
3252 - Dead Weight, Ton
4829 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

C - CONSTRUCTOR Industrial Vessel · MISLE 1650358 · 21 January 2023 · activity 7640305

Inspection history · 18

31 October 2024 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8027368
18 April 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7905596
20 February 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7867370
17 November 2023 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7826536
2 September 2023 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7792405
18 August 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7771445
15 August 2023 Damage Survey · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7768794
1 August 2023 Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7757648
15 June 2023 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7714851
23 January 2023 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7625907
21 January 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7640305
2 November 2022 ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7588310
5 August 2021 COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7277647
12 July 2021 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7253638
10 July 2021 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7327207
25 June 2021 ACP Drydock Oversight · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7240834
14 July 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5940199
13 May 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876270

Deficiency record · 4

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2024 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including in paint lockers, unless the Administration is satisfied that such equipment is appropriate for the space concerned. The vessel’s paint locker has an intrinsic light apparatus installed that is rated for Class 1, Div 2 (Zone 2) locations, and requires one that is rated for Class 1, Div 1 (Zone 0 or 1). SOLAS 74 (2004 cons) Ch. II-1 Reg. 45.10 46 CFR 111.105-43
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2024
Resolved 26 November 2024
Resolution: ABS opened a Finding Numbers Report (408.0) and issued a due date of 23FEB25.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 October 2024 Resolved
In all ships general arrangement plans shall be permanently exhibited for the guidance of ship’s officers, showing clearly for each deck the various fire sections enclosed by “A” & “B” class divisions. The vessel’s fire control plan indicates that the foreword bulkhead in the emergency generator fuel tank space is an A class boundary. A area of the boundary/insulation was missing. SOLAS 74 (1997 cons.) Ch. II-2 Reg. 20.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2024
Resolved 26 November 2024
Resolution: ABS opened a Finding Numbers Report (409.0) and issued a due date of 23FEB25.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2023 Resolved
The owner or operator of an OSV shall make the vessel available for inspection by a Marine Inspector whenever any important repairs or renewals are made. Vessel has reported a hydraulic leak from its swing down thruster. Prior to use of the thruster or DP operations, effect repairs to the satisfaction of the attending/reviewing Marine Inspector.
Action required: 705 - Other - as specified
Due 15 August 2023
Resolved 2 September 2023
Resolution: Cleared by SEC SENE.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 August 2021 Resolved
The vessel had a third party company conduct the fire-fighting servicing on June 17, 2021 and June 21, 2021. While conducting the inspection MI's identified 6 fire extinguishers that were not fully charged. The pull station to the paint locker was not serviced or tested and was incorrectly labeled as a pneumatic station on the servicing report. the report also stated that the manual pull stations were tested as well as the fusible link line in the galley. There is not a fusible link over the deep fat fryer. The weights listed for the fixed fire suppression system are all listed as 101 pounds on the report for the suppression agent. The accuracy of the third-party report is in question by the CG MI's.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2021
Resolution: RO cleared the issued deficiency and witness CO2 testing.

Casualty record · 2

10 July 2021Routine · role: Involved in a Marine Casualty · activity 7327207
21 January 2023Routine · role: Involved in a Marine Casualty · activity 7640305
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record