Records from 1999 to 2024. Most recent: inspection, 31 October 2024.
Inspection history · 43
31 October 2024
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8027368
18 April 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7905596
20 February 2024
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7867370
17 November 2023
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7826536
2 September 2023
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7792405
18 August 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7771445
15 August 2023
Damage Survey · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7768794
1 August 2023
Deficiency Check · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7757648
15 June 2023
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7714851
23 January 2023
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7625907
21 January 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7640305
2 November 2022
ACP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7588310
5 August 2021
COI Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7277647
12 July 2021
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7253638
10 July 2021
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7327207
25 June 2021
ACP Drydock Oversight · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7240834
14 July 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5940199
13 May 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876270
28 August 2014
Deficiency Check · ACP COI Oversight · MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 4961016
22 August 2014
Administrative Inspection
Administrative · Activities Europe · Activity 4962078
18 June 2014
Administrative Inspection
Administrative · Activities Europe · Activity 4891938
7 November 2010
Deficiency Check · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 3850878
4 March 2009
Deficiency Check
Physical examination · Activities Europe · Activity 3427315
31 October 2008
MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Europe · Activity 3354809
28 July 2008
Administrative Inspection
Administrative · Activities Europe · Activity 3281700
27 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3245406
24 October 2007
ACP COI Oversight · MTSA/ISPS Verification · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3095293
5 October 2007
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3073667
18 October 2006
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2802883
25 January 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2572894
27 September 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502022
16 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293919
13 December 2004
MTSA Verification · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2258080
26 October 2004
Cargo Tank Internal · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2228345
3 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979627
17 September 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1907204
24 October 2002
Internal Structural Exam · Re-Inspection · Cargo Tank Internal · Underwater Inspection in lieu of Drydock
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1695517
2 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1600100
24 October 2001
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1425231
12 April 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061917
7 February 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058951
4 November 1999
Initial Construction-Excluding Oversight · Deadweight Survey · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397279
30 September 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348733
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 October 2024
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including in paint lockers, unless the Administration is satisfied that such equipment is appropriate for the space concerned. The vessel’s paint locker has an intrinsic light apparatus installed that is rated for Class 1, Div 2 (Zone 2) locations, and requires one that is rated for Class 1, Div 1 (Zone 0 or 1).
SOLAS 74 (2004 cons) Ch. II-1 Reg. 45.10
46 CFR 111.105-43
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2024
Resolved 26 November 2024
Resolution: ABS opened a Finding Numbers Report (408.0) and issued a due date of 23FEB25.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 October 2024
Resolved
In all ships general arrangement plans shall be permanently exhibited for the guidance of ship’s officers, showing clearly for each deck the various fire sections enclosed by “A” & “B” class divisions. The vessel’s fire control plan indicates that the foreword bulkhead in the emergency generator fuel tank space is an A class boundary. A area of the boundary/insulation was missing.
SOLAS 74 (1997 cons.) Ch. II-2 Reg. 20.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 December 2024
Resolved 26 November 2024
Resolution: ABS opened a Finding Numbers Report (409.0) and issued a due date of 23FEB25.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2023
Resolved
The owner or operator of an OSV shall make the vessel available for inspection by a Marine Inspector whenever any important repairs or renewals are made. Vessel has reported a hydraulic leak from its swing down thruster. Prior to use of the thruster or DP operations, effect repairs to the satisfaction of the attending/reviewing Marine Inspector.
Action required: 705 - Other - as specified
Due 15 August 2023
Resolved 2 September 2023
Resolution: Cleared by SEC SENE.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 August 2021
Resolved
The vessel had a third party company conduct the fire-fighting servicing on June 17, 2021 and June 21, 2021. While conducting the inspection MI's identified 6 fire extinguishers that were not fully charged. The pull station to the paint locker was not serviced or tested and was incorrectly labeled as a pneumatic station on the servicing report. the report also stated that the manual pull stations were tested as well as the fusible link line in the galley. There is not a fusible link over the deep fat fryer. The weights listed for the fixed fire suppression system are all listed as 101 pounds on the report for the suppression agent. The accuracy of the third-party report is in question by the CG MI's.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 August 2021
Resolution: RO cleared the issued deficiency and witness CO2 testing.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 28 August 2014
Resolved
Fire systems shall be maintained and ready for immediate use. During inspection, the emergency fire pump would not prime/operate as designed. SOLAS II-2/14.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2014
Resolution: Recieved class report from ABS that the vessel demonstrated proper operation of the emergency fire pump, the pump was able to provide required fire fighting water from 2 fire stations at the furthest distances from the pump.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 August 2014
Resolved
Vessels shall have oil filtering equipment to ensure discharged oily mixtures do not exceed 15 ppm. During inspection, proper operation of OWS could not be verified. Vessel to retain all oily mixtures on board/discharge ashore until successful demonstration of OWS. MARPOL Annex 1/14.6.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 21 September 2014
Resolution: Received class report from ABS attesting that the vessel demonstrated proper OWS operation to the attending marine surveyor.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 28 August 2014
Resolved
Vessels shall have the necessary equipment to complete the Automation Test Procedure. During inspection, vessel did not have the necessary equipment to complete lube oil shutdowns or high jacket water temperature alarms (hand pump, hot pot, etc). 46 CFR 130.480 (c).
Action required: 705 - Other - as specified
Due 14 November 2014
Resolved 15 November 2014
Resolution: Vessel sent a picture of the equipment on the vessel along with an email from ABS stating that the equipment was onboard and operational.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 28 August 2014
Resolved
The angular position of the rudder should be recognizable on the bridge/steering gear room. During operational test of steering gear, it was noted that the starboard rudder angle indicators on the bridge and in the steering gear room was more than 40 degrees different from actual z drive position. Calibrate/adjust rudder angle indicator. SOLAS II-1/29.11.2
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 29 August 2014
Resolution: All rudder angle indicators calibrated/synced. Verified/tested from all steering locations by attending MI.
Electrical › Electric Generation Source (service) › Panelboard
Issued 28 August 2014
Resolved
Machinery and associated controls shall be adequate for pupose intended. While attempting to demonstrate reverse power relay trip on #2 SSDG, the governor/frequency control on the switchboard was not responding. Repair/replace switch and demonstrate proper operation. SOLAS II-1/26.1.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 29 August 2014
Resolution: Potentiometer replaced and switch/reverse power tested by attending MI.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 28 August 2014
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid damage and batteries shall be properly secured. During exam, it was noted that the secondary start batteries for the EDG and associated cables were improperly installed/hanging from overhead. Properly support cables and fix battery installation. SOLAS II-1/45.5.1.
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 29 August 2014
Resolution: Cables were properly supported and batteries secured. Installation verified by attending MI.
Fire Fighting › Remote Fuel Shutoff › General
Issued 28 August 2014
Resolved
Lablel emergency fuel oil shutdown (EDG) in accordance with fire control plan. SOLAS II-2/4.2.2.3
Action required: 705 - Other - as specified
Due 28 September 2014
Resolved 29 August 2014
Resolution: Fuel shutoff properly labeled and verified by attending MI.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 18 June 2014
Resolved
Lost port anchor while at anchor in the Takoradi Anchorage, Ghana.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2014
Resolved 22 August 2014
Resolution: Received ABS Report for new port anchor and installation.
Lifesaving › Launching Appliances › Release Mechanism
Issued 31 December 2008
Resolved
Appropriately mark release hook for rescue boat in accordance with NVIC 08-04 or replace with CG approved hook.
Due 28 February 2009
Resolved 27 February 2009
Navigation › Piloting/Steering › Marine Charts
Issued 13 November 2008
Resolved
Obtain new or provide updated navigation charts for area of operation. Item reported cleared via E-mail dated 07Dec2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 20 November 2009
Resolved 23 October 2009
Communications › Radio Communications › EPIRB
Issued 13 November 2008
Resolved
Conduct and log required monthly EPIRB test and weekly GMDSS test. Item reported cleared via E-mail dated 18Nov2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 20 November 2009
Resolved 26 October 2009
Fire Fighting › Structural - A Class Divisions › Doors
Issued 13 November 2008
Resolved
Ensure all Class A fire doors close and latch when released (including stair wells, galley service door). Item reported cleared via E-mail dated 07Dec2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 20 November 2009
Resolved 26 October 2009
Lifesaving › Launching Appliances › Release Mechanism
Issued 13 November 2008
Resolved
Provide Coast Guard approval letter for rescue boat release hook. Item reported cleared via E-mail dated 24Dec2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 20 November 2009
Resolved 26 October 2009
Deck/Cargo › Mooring/Anchoring › Brake
Issued 13 November 2008
Resolved
Prove proper operation of port anchor windlass brake.
Due 13 January 2009
Resolved 13 November 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 November 2008
Resolved
Report proven repairs to and reliability of intermittent overspeed shutdown on Port Main Diesel Engine. Item reported cleared via E-mail dated 17Dec2008 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 20 November 2009
Resolved 26 October 2009
Communications › Radio Communications › EPIRB
Issued 18 October 2006
Resolved
REGISTER EPIRB WITH VSL CALL SIGN
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2006
Resolved 18 October 2006
Resolution: COMPLETED
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 18 October 2006
Resolved
ADD SAFETY HARNESS TO MONTHLY INSPECTION LOG AND INSPECT MONTHLY.
Action required: 705 - Other - as specified
Due 18 November 2006
Resolved 18 October 2006
Resolution: COMPLETED
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 18 October 2006
Resolved
RENEW BOTTOM SEAL ON FREEZER, LEEKING BY AND CAUSING A ICE/SLIPPING HAZARD.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 October 2006
Resolved 21 October 2006
Resolution: COMPLETED
Electrical › Electric Supply System (service)
Issued 23 October 2002
Resolved
PROVIDE PROPER BATTERY INSTALLATION FOR BATTERY INSTALLED AT O2 DECK LEVEL CLOSET WHERE INTAKE VENTILATION IS LOCATED. LEGACY COMPONENT DESC: Battery Installation
Action required: 705 - Other - as specified
Due 23 November 2002
Resolved 18 September 2003