07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 July 2025
Resolved
All fire main piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. MI observed a significant leak in the fire pump shaft packing and in the piping threads on the discharge side of the fire pump. 46 CFR 181.15-5(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2025
Resolved 17 July 2025
Resolution: Leaks repaired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 July 2025
Resolved
Stations in the maritime service must be licensed by the FCC. MI observed the vessel's station license was expired. Vessel is limited to operations less than 1,000 feet from shore.
47 CFR 80.13(a)
Action required: 705 - Other - as specified
Due 22 July 2025
Resolved 17 July 2025
Resolution: Station License applied for. Temp issued.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 July 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions MI observed no emergency checkoff lists in an area accessible to passengers. Rectify within 7 days. 46 CFR 185.510
Action required: 705 - Other - as specified
Due 22 July 2025
Resolved 23 July 2025
Resolution: Emergency instructions posted.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 July 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions MI observed multiple missing recommended details on the vessel's checkoff list. Rectify within 7 days. 46 CFR 185.510
Action required: 705 - Other - as specified
Due 22 July 2025
Resolved 23 July 2025
Resolution: Emergency instructions updated SAT.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 15 July 2025
Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew members are familiar with their duties. MI observed a severe lack of communication among the crew members that resulted in a delay and unsafe manner of recovery during the man overboard drill. Additionally, 02 crew members asserted to not know their responsibilities during a fire. Rectify within 7 days.
46 CFR 185.524
Action required: 705 - Other - as specified
Due 22 July 2025
Resolved 23 July 2025
Resolution: Drills conducted sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 15 July 2025
Resolved
On a vessel of at least 7.9 meters in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each bilge well. MI observed the bilge well in the berthing room space had a high water alarm that provided a visual alarm to the operating station, but did not provide an audible alarm. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 23 July 2025
Resolution: Audible alarm operates SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 July 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. MI observed cables connecting each bank of batteries that were spliced together and wrapped with electrical tape in the engine room.
46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 17 July 2025
Resolution: Termional connections properly enclosed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2025
Resolved
All vessels shall be provided with suitable steering apparatus. MI observed severely corroded flexible hose fittings going into the steering ram in the lazarette.
46 CFR 182.30-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 17 July 2025
Resolution: Fittings replaced in kind.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 July 2025
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible. MI observed COI pages stapled together under the glass such that all pages were not visible. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 23 July 2025
Resolution: COI posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 July 2025
Resolved
The Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible. Stability letter not posted as to be visible.
46 CFR 176.306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2025
Resolved 23 July 2025
Resolution: Letter posted SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 September 2024
Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has high resistance to saltwater, petroleum oils and vibration. Marine inspector observed a fuel leak from flexible hose attached to the port main diesel engine, outboard side of motor.
46 CFR 182.720(e)
46 CFR(10-1-94 Edition) 182.20-40(2); 60c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 September 2024
Resolution: Vessel rep submitted photograph of fuel line replaced. Upon review, deficiency resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 September 2024
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Marine Inspector observed missing guard for rotating belt on forward section of the starboard main diesel engine.
46 CFR 177.960; 16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 20 January 2025
Resolution: Reviewed photograph sent from vessel rep, all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 September 2024
Resolved
Employers must maintain records of chemical tests to identify the total number of individuals chemically tested annually for dangerous drugs. Marine inspector observed current employment list does not reflect new employee hired.
46 CFR 16.260(b)(2);16c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 23 January 2025
Resolution: Reviewed report submitted by vessel rep, all sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 September 2024
Resolved
All marine employers must submit drug testing program data required by 49 CFR 40.26 and appendix H to 49 CFR
40. Marine Inspector observed no copy of report on file
verifying proof of submission.
46 CFR 16.500(a)(1);16c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 23 January 2025
Resolution: Reviewed report submitted by vessel rep, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 September 2024
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Marine Inspector observed 01 life float light not operational.
46 CFR 180.175(d);16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 20 January 2025
Resolution: Reviewed photos submitted by vessel rep, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 September 2024
Resolved
The equipment required for life floats must meet the following specifications: Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. Marine inspector observed all paddles for 07 life floats not lashed to the life floats which it belongs to.
46 CFR 180.175(f)(2);16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 20 January 2025
Resolution: Reviewed photos submitted by vessel rep, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 September 2024
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Marine inspector observed 03 light missing guards.
46 CFR 183.410(a);16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 20 January 2025
Resolution: Reviewed photos submitted by vessel rep, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 September 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Marine inspector observed fire detection systems not interconnected.
46 CFR 181.405(c);16c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2024
Resolved 24 January 2025
Resolution: Reviewed video submitted by vessel rep, all sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 12 September 2023
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
MI observed EPIRB batter was expired.
Route reduced to no more than 3 miles from the coastline.
46 CFR 180.64
Action required: 705 - Other - as specified
Due 12 September 2023
Resolved 14 September 2023
Resolution: Vessel sent photo showing properly installed EPIRB with new battery.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 12 September 2023
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR 80.
MI observed that the MF radio was inoperable.
Route restricted to no more than 20 miles from the coastline.
46 CFR 184.502
Action required: 705 - Other - as specified
Due 12 September 2023
Resolved 19 October 2023
Resolution: Vessel had technician repair radio, all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 September 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
MI observed that the port side navigation light was inoperable.
Restricted to daylight operations only.
46 CFR 183.420
Action required: 705 - Other - as specified
Due 12 September 2023
Resolved 13 September 2023
Resolution: Vessel rep purchased new nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 September 2023
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light approved in accordance with 160.012 in subchapter Q.
MI observed 02 life jacket lights were inoperable.
Restricted to 74 passengers when operating on an oceans or coastwise route.
46 CFR 180.75(a)
Action required: 705 - Other - as specified
Due 12 September 2023
Resolved 12 October 2023
Resolution: Vessel rep replaced life jacket lights.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 September 2023
Resolved
Each life float must have a floating water light approved under series 161.010.
MI observed 01 life float light that was inoperable.
Vessel restricted to daylight operation only.
46 CFR 180.175(f)(4)
Action required: 705 - Other - as specified
Due 12 September 2023
Resolved 12 October 2023
Resolution: Vessel rep replaced 01 light, and a batter in the other light.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 12 September 2023
Resolved
When life floats are stowed in tiers, the separate units must be kept apart by spacers.
MI observed that each tier of life floats did not have spacers in use.
One week given to rectify deficiency.
46 CFR 180.137(f)
Action required: 705 - Other - as specified
Due 19 September 2023
Resolved 2 October 2023
Resolution: Picture evidence submitted showing spacers utilized.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 12 September 2023
Resolved
Each life float and buoyant apparatus must be individually attached to the painter by a line meeting 180.175(f)(3)(ii), (iii), and (iv) and long enough that each life float can float without contacting any other life float in the group.
MI observed that port side life float(s) were not attached to the weak link via the painter.
One week given to rectify deficiency.
46 CFR 180.137(e)(3)
Action required: 705 - Other - as specified
Due 19 September 2023
Resolved 16 October 2023
Resolution: Vessel POC attached lifefloat to painter.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 12 September 2023
Resolved
At least 50% of the crew shall have current first aid and CPR certifications.
MI observed that none of the crew had current first aid or CPR certificates.
Vessel given one week to identify certified course.
46 CFR 15.103
NVIC 1-91
Action required: 705 - Other - as specified
Due 19 September 2023
Resolved 16 October 2023
Resolution: Vessel crew members attended CPR/First Aid training.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2023
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 150 degrees F must be suitably insulated where necessary to prevent injuries.
MI observed port side MDE lagging was torn.
46 CFR 177.970
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 2 October 2023
Resolution: Picture evidence submitted showing lagging replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 September 2023
Resolved
The installation and location of each portable fire extinguisher must be to the satisfaction of the Officer in Charge, Marine Inspection.
MI observed bracket for the portable fire extinguisher at the bottom of the stairwell leading to the engine room was severely wasted, replace.
46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 2 October 2023
Resolution: Picture evidence submitted showing new PFE brackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 September 2023
Resolved
The marine employer shall ensure that all personnel directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol in accordance with 46 CFR 4.06.
MI observed alcohol test strips were expired. Replace strips within one week.
46 CFR 16.240
Action required: 705 - Other - as specified
Due 19 September 2023
Resolved 2 October 2023
Resolution: Picture evidence submitted showing new test strips.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 September 2023
Resolved
Vessels which have overnight accommodations, or operate on an oceans or coastwise route must install interconnected fire detection systems in all enclosed areas where passengers and/or crew have routine access, including accommodation spaces and machinery spaces.
MI observed no interconnected system was in place.
Provide plan for placement of fire detector locations, and install system.
46 CFR 185.364
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 24 January 2025
Resolution: Interconnected fire detection system installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2023
Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
MI observed that there was not a designated location for the charging of devices containing a lithium ion battery.
46 CFR 185.364
CG-CVC Policy Letter 20-03
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 16 October 2023
Resolution: Vessel rep sent picture showing which areas are designated/not designated for charging.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 September 2023
Resolved
Vessels described by 46 CFR 175.110(d) must ensure that the two means of escape required in paragraph (b) of this section are unobstructed and the door, hatch, or cuttle is not located directly above, or dependent on, a berth.
MI observed that one means of escape from the lower accommodation space was dependent on a berth for escape.
46 CFR 177.500(n)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2023
Resolved 19 October 2023
Resolution: Vessel installed step in lower berthing, allowing for it to be used rather than the berth for escape.
10 - Safety of Navigation › N/A - No Subsystem › Bridge Navigation Watch Alarm System (BNWAS)
Issued 12 September 2023
Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46 CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the watchmen required in paragraph (a) of this section. The Coast Guard will work with the vessel operators to determine a reasonable implementation schedule once the plans are accepted. The monitoring device(s) must:
1. Ensure the wakefulness of the crew in the event that the watchman required in paragraph (a) of this section is unresponsive;
2. Remain operable during the nighttime watch; and
3. Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards.
MI observed that no BNWAS type system was installed. Submit plan for type and installation of system.
46 CFR 185.410(b)(1)-(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 10 September 2024
Resolution: Marine Inspector observed operational test of equipment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
MI observed stbd side steering hydraulic line fitting was severely wasted, replace.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 September 2023
Resolved 12 October 2023
Resolution: Vessel rep submitted picture showing hydraulic fitting replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 September 2023
Resolved
A power-driven vessel underway shall exhibit a sternlight showing an unbroken light over an arc of the horizon of 135 degrees and so fixed as to show the light 67.5 degrees from right aft on each side of the vessel.
MI observed stern light was inoperable.
Restricted to day light operations.
33 CFR 83.23(a)(iv)
Action required: 705 - Other - as specified
Due 12 September 2023
Resolved 12 October 2023
Resolution: Vessel rep submitted picture showing mast head light operable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022
Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, which are completed to the satisfaction of the cognizant Officer in Charge, Marine Inspection (OCMI) on or after March 11, 1996, must comply with this part.
MI identified a new battery charger installation in the engine compartment.
Submit electrical plans to the MSC for review and approval.
46 CFR 183.115
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 14 July 2022
Resolution: The owner/operator removed the battery charger and all associated conductors from the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 June 2022
Resolved
Each hatch exposed to the weather must be watertight.
Identified a flush deck hatch on the laz/fuel tank space that has a damaged gasket.
46 CFR 171.124(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 14 July 2022
Resolution: The flush deck hatch gaskets were replaced and renewed like/in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 June 2022
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant.
Identified 7 fractured paddles for life floats.
46 CFR 180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2022
Resolved 14 June 2022
Resolution: The owner/operator replaced 7 life float paddles in kind and marked them IAW regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 June 2022
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Each platform must be of a material that is resistant to deterioration by exposure to weather or must have a surface that protects it from deterioration by exposure to weather. Each metal part of a buoyant apparatus must be -410 stainless steel or have salt water and salt air corrosion characteristics equal or superior to 410 stainless steel; and
Galvanically compatible with each other metal part in contact with it.
Identified the corrosion to all life float metal used to support the net arrangement required to have a min breaking strength of 355 lbs.
Replace all metal with 410 stainless.
46 CFR 180.175
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 5 August 2022
Resolution: The operator constructed a weighted pvc piping ring in place of the metal. The PVC supports the net appropriately and naturally permits the netting to deploy in water.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 June 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
19 Adult lifejackets were found unsuitable for service.
Passenger count reduced to 59 when operating on voyages less than 12 hours.
46 CFR 180.71
Action required: 705 - Other - as specified
Due 14 June 2022
Resolved 14 July 2022
Resolution: The operator purchased 19 approved adult lifejackets and marked them IAW regulations. Lights and whistles were found attached.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 28 September 2021
Resolved
A marine employer whose vessel is involved in a casualty or incident...shall comply with the requirements of 4.06. The alcohol testing of each individual must be conducted within 2 hours.
Alcohol testing devices are expired.
46 CFR 185.212 & 46 CFR 4.06-3(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2021
Resolved 6 October 2021
Resolution: Operator purchased new alcohol testing devices.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 28 September 2021
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve.
03 lifefloat paddles found fractured.
46 CFR 180.175(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2021
Resolved 6 October 2021
Resolution: Operator purchased new lifefloat paddles.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 September 2020
Resolved
A power-driven fire pump shall be installed on each mechanically propelled "S" vessel which is a ferry vessel or which is permitted to carry more than 49 passengers, and on each mechanically propelled "L" vessel per 46 CFR 181-10(a). The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The master of the vessel was unable to energize the power-driven fire pump using power from the ship's generator during the inspection. The crew is unable to effectively fight a fire using the fire pump and fire main system. Prove proper operation of the fire
pump prior to carrying passengers. 46 CFR 181-10(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 21 September 2020
Resolution: The fire pump and fire main were operational tested by the crew and appeared satisfactory on this date.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 September 2020
Resolved
Means of escape from lounge areas shall be provided in accordance with Subpart 177.15. Except as otherwise provided in this section, all vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed, so located that if one is not available the other may be. The vertical escape route located in the passenger berthing is not functional and found with objects that impede egress. The aft vertical emergency escape hatch is blocked on the deck above by a permanently installed table fixture. The crew installed a locking nut under the table top which must be twisted to release the table top from its foundation. A passenger must be able to find the locking nut behind the table leg, twist the locking nut 180 degrees to release the table from its foundation, and lift the table vertically to escape the berthing area. Provide two functional avenues of escape from all general areas accessible to the passengers prior to carrying passengers on overnight voyages. 46 CFR 177.30-7(c)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2020
Resolved 18 September 2020
Resolution: The crew removed the table from above the emergency escape hatch. There are two functional avenues of escape from all general areas accessible to the passengers in the berthing area.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 September 2020
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck as per subpart 177.30-7 of this subchapter. The passenger berthing area has one emergency light positioned at the top of the forward vertical staircase and no other emergency lighting. The second avenue of escape in the passenger berthing area is located aft of the staircase and obstructed from the one light that is installed at the top of the staircase. Provide adequate emergency lighting along the line of escape located aft of the staircase in the passenger
berthing area prior to carrying passengers on overnight
voyages. 46 CFR 184.30-5
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2020
Resolved 18 September 2020
Resolution: The crew installed additional emergency lighting in the vicinity of the line of escape located aft of the staircase in the passenger berthing area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2020
Resolved
Each generator and motor must be designed for an ambient temperature of 50 deg C except that: a generator or motor designed for 40 deg C may be used in 50 deg C ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. Each generator must be protected by an overcurrent device set value not exceeding 115 percent of the generator full load rating. Generator installed in the engine room is rated for 40 deg C at ambient temperature. No Coast Guard approved electrical plans or AC load analysis was completed prior to installation of the new AC generator in 2008. Provide an AC load analysis and submit AC electrical plans to USCG Marine Safety Center for review. Contact USCG Sector St. Pete once electrical plans are approved by MSC. 46 CFR 183.320(b)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 22 January 2021
Resolution: The operator hired a third party technician to derate the generator to 80% (8kw). Tech found a 40 amp breaker installed. Contacted manufacturer that recommended 35 amp breaker to be installed in order to derate to 8kw. Operator completed install.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 September 2020
Resolved
Use of a Coast Guard type-approved AIS Class B device in lieu of an AIS Class A device is permissible on a self propelled vessel of 65 feet or more in length, engaged in commercial service. A Class A or Class B AIS is not installed on the vessel. Install a Class A or Class B AIS and prove proper operation of the AIS to the attending USCG marine inspector.
33 CFR 164.46(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 29 September 2020
Resolution: Class B AIS installed at the operating station. AIS was tested and is operational.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2020
Resolved
New installations of electrical equipment and material, and the repair or replacement of wire and cable, on an existing vessel, must comply with 46 CFR 183. Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. 120 V AC conductors found disconnected behind the breaker panel under the operating station on the starboard side and behind the steering apparatus. Install conductors in accordance with 46 CFR 183.340 and contact USCG marine inspector for re-inspection. 46 CFR 183.200(c)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 18 September 2020
Resolution: AC conductors were removed behind the breaker panel at the operating station and no longer pose a danger to personnel or the vessel.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 15 September 2020
Resolved
Each Marine Sanitation Device certified under this section which is installed aboard an inspected vessel must comply with 33 CFR 159.97 and Subchapter F of Title 46 CFR. MSD Type III holding tanks located above the port and starboard fuel tanks were found with corroded inlet pipes. Crop and renew inlet piping on both tanks prior to receiving credit at the next scheduled dry dock. 33 CFR 159.12a(d)
Action required: 705 - Other - as specified
Due 15 October 2020
Resolved 17 November 2020
Resolution: Operator extended flexible hose to cover corroded piping. Failure of the piping would lead to gravity
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 September 2020
Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one
at the tank connection and one at the engine end of the fuel line to stop the fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an accessible position on the weather deck. The fuel tank remote shutoff located outside of the tank compartment is attached to a wood block in between the shutoff valve and remote actuation lever. The wood block is not an acceptable attachment point for the shutoff valve in the event of a fire. Replace the wood block with a suitable remote shutoff valve that is accessible from outside of the tank compartment. 46 CFR 182.20-40(b)(3)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 18 September 2020
Resolution: The wood block was removed and replaced with a piece of steel. The emergency shut down was exercised and place back into service.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 September 2020
Resolved
All cable and wire must not be installed with sharp bends. Conductors installed on starting and house batteries located on the port and starboard side were found with sharp bends at the battery terminal. The conductor between the starting battery and the engine starter do not have overcurrent protection and sharp bends will create heat at the cold cranking amperage (550amps). Install conductors on house batteries so no sharp bends are installed. 46 CFR 183.340(b)(5)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 18 September 2020
Resolution: The operator removed the conductors from the battery and observed corrosion and burn marks. The conductors were replaced in kind and installed without sharp bends.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 September 2020
Resolved
Where an exhaust pipe passes through a watertight bulkhead, the watertight integrity of the bulkhead must be maintained. Where flexibility is necessary, a section of flexible metallic hose may be used for wet exhaust systems. Newly installed generator exhaust flexible hose found backing off of the exhaust outlet on the starboard side of the engine room. Water found under the flexible hose at the side shell plate. Renew as original. 46 CFR 182.430(f)
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 18 September 2020
Resolution: The operator renewed the exhaust flexible hose found backing off of the exhaust outlet on the starboard side of the engine room. The exhaust piping was found installed to the bulkhead with two hose clamps.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 September 2020
Resolved
Each hatch exposed to the weather must be watertight. Discovered a watertight hatch used for entry into the anchor compartment on the main deck missing a rubber gasket. Replace rubber gasket and make hatch watertight. 46 CFR 171.124(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2020
Resolved 21 September 2020
Resolution: The operator replaced the hatch gasket in kind and returned the hatch to service.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 September 2020
Resolved
Raw water pickup welded spool piece for water pump located on the starboard side of the engine room at the bottom plate was found corroded. Crop and renew prior to credit at the next scheduled dry dock. 46 CFR 176.20-1
Action required: 705 - Other - as specified
Due 15 October 2020
Resolved 17 November 2020
Resolution: The hull plate and spool piece were cropped and renewed as original.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 September 2020
Resolved
The inspection and maintenance of survival craft and EPIRB shall be logged or otherwise documented. No log for survival craft inspection was available for inspection. Begin a log for survival craft and EPIRB maintenance, testing, and inspection. 46 CFR 185.722 and 46 CFR 185.728
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2020
Resolved 18 September 2020
Resolution: The operator logged the EPIRB and life raft inspections conducted on the annual inspection. The log will be updated monthly.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 September 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date U.S. Coast Pilot and Coast Guard Light List. A U.S. Coast Pilot #5 for the Tampa, FL area is not on board. A 2020 Coast Guard Light List is not on board.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2020
Resolved 18 September 2020
Resolution: U.S. Coast Pilot #5, 2020 version, and 2020 light list for FL are onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 1 October 2019
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be installed/fitted along the line of escape for lounge areas below the main deck.
Overnight passenger accommodation space light inoperable. Repair and prove proper operation prior to carriage of overnight passengers. IAW: 46 CFR 184.30-5
Action required: 705 - Other - as specified
Resolved 22 October 2019
Resolution: O/O repaired and proved proper operation of emergency lighting in overnight accommodation space.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 October 2019
Resolved
The inspection and maintenance of survival craft shall be logged or otherwise documented.
No log for survival craft. Start maintenance log. IAW: 46 CFR 185.702
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 22 October 2019
Resolution: O/O created survival craft maintenance log.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 October 2019
Resolved
Electrical equipment must be installed to minimize accidental personnel contact with energized parts.
Starboard distribution panel has open spare. Repair. IAW: 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 22 October 2019
Resolution: O/O removed electrical hazard from engine room starboard distribution panel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2018
Resolved
Vessels shall be inspected in accordance with acceptable standards to the OCMI and good marine practice.
Fire hose mount is wasted. Repair prior to completion of next drydock. - 46CFR176.25-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2018
Resolution: Repaired to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 October 2018
Resolved
Piping used in a vital system must be composed of ferrous materials. Bilge system has multiple areas of flexible non-metallic hose. Replace in accordance w/ approved original piping plan. - 46CFR182.710(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2018
Resolution: Repaired to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2018
Resolved
All escape hatches shall be marked on both sides using at least 1 inch letters: "Emergency Exit, Keep Clear." Passenger berthing needs markings. Rectify prior to completion of next drydock. - 46CFR815.30-15
Action required: 705 - Other - as specified
Resolved 19 October 2018
Resolution: Owner/operator stenciled "Emergency Exit, Keep Clear" on both sides of the escape hatch.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 September 2018
Resolved
Vessels shall be inspected in accordance with acceptable standards to the OCMI and good marine practice.
Fire hose mount is wasted. Repair prior to completion of next drydock. - 46CFR176.25-1
Action required: 705 - Other - as specified
Resolved 25 September 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 September 2018
Resolved
Piping used in a vital system must be composed of ferrous materials. Bilge system has multiple areas of flexible non-metallic hose. Replace in accordance w/ approved original piping plan. - 46CFR182.710(c)
Action required: 705 - Other - as specified
Resolved 25 September 2018
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 27 October 2016
Resolved
Repair cracked weld on stbd stanchion on main deck IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 3 November 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 October 2016
Resolved
Repair cracked weld on exhaust support IAW 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 3 November 2016
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 27 October 2016
Resolved
Repair cracked weld in fwd compartment on transverse beam holding the anchor line IAW 46 CFR 176.710.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 3 November 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 11 October 2016
Resolved
Program MMSI number in to VHF Radio with DSC function.
Due 27 October 2016
Resolved 27 October 2016
Resolution: MMSI number programmed into both VHF radios.