Records from 1981 to 2010. Most recent: inspection, 20 January 2010.
Inspection history · 51
20 January 2010
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4055140
3 July 2009
Periodic Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3522748
21 August 2008
Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3304630
12 June 2008
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3235177
21 September 2007
Examination of Repairs
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3063429
2 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2980576
12 October 2005
Hull Examination · COI Inspection · Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2513949
19 November 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2244296
21 September 2004
COI Inspection · Administrative Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2204145
12 January 2004
Hull Examination · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1982114
3 January 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1976402
3 July 2003
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1833818
31 January 2003
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1738061
10 September 2002
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1673808
7 August 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1658047
2 July 2002
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1640057
5 June 2002
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1626577
9 May 2002
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1614842
10 August 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1410589
21 September 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 103842
8 September 2000
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 822497
6 July 2000
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1052862
7 June 2000
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1393476
12 May 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376163
8 May 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817878
8 May 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1104637
27 December 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1094752
20 May 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470688
16 August 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874712
19 May 1995
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390065
18 May 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1442147
29 November 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 848073
27 September 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 843623
31 May 1993
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436767
15 July 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408904
27 November 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1262722
15 July 1991
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1252062
26 June 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914137
15 December 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236748
9 February 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914207
10 February 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1039001
13 February 1988
Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 990850
18 November 1987
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1331928
30 April 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336224
12 March 1986
COI Inspection · Credit Drydock
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1300927
28 February 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 978281
24 February 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279297
24 February 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281174
18 February 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1272129
11 February 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966526
29 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968126
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 June 2008
Resolved
Replace wasted life jackets: vsl will be limited in total persons allowed by amount of remaining jackets - 38 total.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 21 August 2008
Resolution: Lifejackets replaced to satisfaction, passenger + crew count as per COI.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 June 2008
Resolved
Repair/Replace Hz gauge for generator switchboard by 28AUG08.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 August 2008
Resolved 21 August 2008
Resolution: Replaced to satisfaction
Electrical › Electric Supply System (service) › Cable
Issued 2 July 2007
Resolved
Remove Dead End wires IWO Lazarette.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Removed all dead end wires.
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 2 July 2007
Resolved
Repair fractures and buckled deck IWO aft stbd bit.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Inserted Deck
Construction/Loadline › Penetrations › Weld
Issued 2 July 2007
Resolved
Crop and renew through hole IWO A/C condensate drain on port side, with backing plate and new pipe insert.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Installed insert and new pipe
Construction/Loadline › Hull › Weld
Issued 2 July 2007
Resolved
Gouge and weld wasted seam IWO passenger compartment on port side Centerline approx 1 ft from keel. Make space clean and available for further inspection.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Gouge and welded seam.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 2 July 2007
Resolved
Remove and replace plastic drum with lube oil with metal containment i.e. drum or tank with fixed piping.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Removed plastic drum
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 2 July 2007
Resolved
Install non-conductive mat IWO lazarette
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Installed matting
Stability › Watertight Integrity › General
Issued 2 July 2007
Resolved
Replace all foam gaskets IWO engine room hatches and lazarette with rubber. Replace and adjust door WTD IWO Galley.
Action required: 705 - Other - as specified
Resolved 10 July 2007
Resolution: Replaced all gaskets with proper gasket material.
Engineering › Generator (propulsion-electric) › Overcurrent Devices Circuitry
Issued 10 July 2006
Resolved
Provide proper operation of stbd generator overcurrent protection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 21 July 2006
Engineering › Generator (propulsion/auxiliary-electric) › Feeder Circuitry
Issued 10 July 2006
Resolved
Provide continous operation of port generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 21 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 July 2006
Resolved
Provide exhaust lagging for port MDE and generator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 21 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 July 2006
Resolved
Repair stbd generator exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 21 July 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 July 2006
Resolved
Provide hose clamps for stbd MDE and generator raw water intake.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 21 July 2006
Engineering › Freshwater Generation System › Pump
Issued 10 July 2006
Resolved
Repair/renew freshwater pump IWO generator room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 21 July 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 July 2006
Resolved
Properly label individual bilge alarms.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 21 July 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 July 2006
Resolved
Provide proper operation of bilge alarms.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 21 July 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 6 July 2006
Resolved
Provide non expired USCG approved life jacket lights for all lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 10 July 2006
Resolution: Vessel provided non-expired lights for all life jackets.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 6 July 2006
Resolved
Provide currently corrected charts and publications.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 10 July 2006
Resolution: Vessel provided current charts and publications.
Lifesaving › Lifefloat › Float-free Link
Issued 6 July 2006
Resolved
Reattach weak link to lifefloat.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 10 July 2006
Resolution: Weak link was properly attached.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 6 July 2006
Resolved
Post station bill in a visible location.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 10 July 2006
Resolution: Vessel posted station bill.
Engineering › Lubricating Oil Service System › Gauge
Issued 6 July 2006
Resolved
Provide adequate operation of the oil pressure gauge at the control station for stbd MDE.l
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 21 July 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 6 July 2006
Resolved
Provide adequate operation of the stbd MDE water temp gauge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 21 July 2006
Lifesaving › Lifefloat › Serviceable
Issued 6 July 2006
Resolved
Provide spacers to seperate life floats that are stacked.
Condition: Unknown
Due 6 July 2006
Resolved 10 July 2006
Resolution: Vessel provided adequate spacers for lifefloats.
Engineering › Steering Gear System › Bracket/Clamp
Issued 6 July 2006
Resolved
Provide hose clamps for rudder hydaulic hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 10 July 2006
Resolution: Vessel provided hose clamps for hose.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 6 July 2006
Resolved
Provide hose clamps for AC overboard line.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 10 July 2006
Resolution: Vesel provided hose clamps for AC line.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 July 2006
Resolved
Provide visible indicator light for each bilge alarm.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 21 July 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 July 2006
Resolved
Properly demonstrate a satisfactory MOB and fire drill.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 21 July 2006
Fire Fighting › Fire Pumps › Pressure
Issued 12 October 2005
Resolved
Fire pump would not provide 60 PSI.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2006
Stability › Watertight Integrity › General
Issued 12 October 2005
Resolved
Survey main deck and properly repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 October 2005
Resolved
EPIRB antenna is broken.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2006
Engineering › Bilge Water Management System › Not Operational
Issued 30 September 2004
Resolved
Engine room bilge alarm #3 inoperative
Action required: 705 - Other - as specified
Resolved 12 October 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 30 September 2004
Resolved
Label breaker panel in stateroom across from washer
Action required: 705 - Other - as specified
Resolved 12 October 2004
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 30 September 2004
Resolved
Replace globe on light in pantry
Action required: 705 - Other - as specified
Resolved 12 October 2004
Construction/Loadline › Structures › Manhole
Issued 30 September 2004
Resolved
Forward engine room emergency escape missing dogs
Action required: 705 - Other - as specified
Resolved 12 October 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 September 2004
Resolved
Center engine salt water exhaust leak
Action required: 705 - Other - as specified
Resolved 12 October 2004
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 30 September 2004
Resolved
Cap pipes on oil tank in engine room
Action required: 705 - Other - as specified
Resolved 12 October 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 September 2004
Resolved
All machinery space fans are missing covers
Action required: 705 - Other - as specified
Resolved 12 October 2004
Construction/Loadline › Structures › Door
Issued 30 September 2004
Resolved
Aft engine room door dogs need adjusting
Action required: 705 - Other - as specified
Resolved 12 October 2004
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 30 September 2004
Resolved
Stbd generator exhaust leak in overhead
Action required: 705 - Other - as specified
Resolved 12 October 2004
Engineering › Steering Gear System › Linkage
Issued 30 September 2004
Resolved
Port rudder ram missing cotter pin
Action required: 705 - Other - as specified
Resolved 12 October 2004
Communications › Radio Communications › EPIRB
Issued 30 September 2004
Resolved
EPIRB hydrostatic release is expired
Action required: 705 - Other - as specified
Resolved 12 October 2004
Construction/Loadline › Structures › Door
Issued 30 September 2004
Resolved
Watertight door indicator light inoperative
Action required: 705 - Other - as specified
Resolved 12 October 2004
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 30 September 2004
Resolved
Repair water tank movement in steering gear
Action required: 705 - Other - as specified
Resolved 12 October 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 September 2004
Resolved
Vessel is prohibited from operating until a satisfactory re-inspection is completed and COI is properly endorsed. Vessel is to remain at CHS Galveston dock.
Action required: 705 - Other - as specified
Resolved 12 October 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 September 2004
Resolved
Port Nav light is missing bulb
Action required: 705 - Other - as specified
Resolved 12 October 2004
Fire Fighting › Fire Main › Condition
Issued 21 September 2004
Resolved
Make permenant repair on firemain where it penetrates forward engine room bulkhead, starboard side
Action required: 705 - Other - as specified
Resolved 12 October 2004
Lifesaving › Buoyant Apparatus
Issued 3 July 2003
Resolved
Replace life floats with proper life floats 46CFR180.200 prior to operating.
Action required: 705 - Other - as specified
Resolved 24 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 July 2003
Resolved
Demonstrate proper operation of engine stops from wheel house. 46CFR184.620 prior to operating. LEGACY COMPONENT DESC: Engine Stop Buttons
Action required: 705 - Other - as specified
Resolved 1 August 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 July 2003
Resolved
Replace fire pull box IAW Fire Protection Service rpt of 19 June 2003. LEGACY COMPONENT DESC: Operating Controls
Due 29 July 2003
Resolved 1 August 2003
Lifesaving › Lifebuoys
Issued 3 July 2003
Resolved
Renew retro tape on throw ring bouys. 184.604(i)
Due 29 July 2003
Resolved 24 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 July 2003
Resolved
Repair holes in center and port exhaust pipes 182.430(b) LEGACY COMPONENT DESC: Piping (exhaust)
Due 29 July 2003
Resolved 8 August 2003
Electrical › Electrical Distribution System (service)
Issued 3 July 2003
Resolved
Properly label breaker boxes in wheel house and engine room. LEGACY COMPONENT DESC: Panelboard
Due 29 July 2003
Resolved 1 August 2003
Electrical › Electrical Distribution System (service)
Issued 3 July 2003
Resolved
Properly wire stbd engine room blower junction box. LEGACY COMPONENT DESC: Junction Box
Due 29 July 2003
Resolved 1 August 2003
Engineering › Steering Gear System
Issued 3 July 2003
Resolved
Install rudder stops. 182.610(e) LEGACY COMPONENT DESC: Rudder Stops
Due 29 July 2003
Resolved 1 August 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 3 July 2003
Resolved
Install guard on front of stbd MDE 177.960 LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 29 July 2003
Resolved 1 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 July 2003
Resolved
Correctly adjust stbd shaft packing (leaks excessivly) LEGACY COMPONENT DESC: Shaft Packing
Due 29 July 2003
Resolved 1 August 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 3 July 2003
Resolved
Repair light fixture on galley stove. LEGACY COMPONENT DESC: Stove Light Fixture
Due 29 July 2003
Resolved 8 August 2003
Accommodation/Occupational Safety › Ventilation
Issued 3 July 2003
Resolved
Clean oil out of stbd engine room blower. LEGACY COMPONENT DESC: Engine Room Blower
Due 29 July 2003
Resolved 1 August 2003
Documentation › Markings/Placards
Issued 3 July 2003
Resolved
Install Emergency Broadcast Placard IAW 184.506 LEGACY COMPONENT DESC: Emergency Broadcast Placard
Due 29 July 2003
Resolved 1 August 2003
Engineering › Bilge Water Management System
Issued 3 July 2003
Resolved
Demonstrate proper operation of fore peak bilge suction reach rod and valve. 182.510 LEGACY COMPONENT DESC: Piping
Due 29 July 2003
Resolved 8 August 2003
Electrical › Electrical Distribution System (service)
Issued 3 July 2003
Resolved
Replace "Shore Power Available" light and lens cover on generator switch board. LEGACY COMPONENT DESC: Distribution Panel Bus
Due 29 July 2003
Resolved 8 August 2003
Construction/Loadline › Hull
Issued 3 July 2003
Resolved
Repair weld fractures in fore peak and bilge under Capt. qtrs. LEGACY COMPONENT DESC: Weld
Due 29 July 2003
Resolved 1 August 2003
Engineering › Steering Gear System
Issued 3 July 2003
Resolved
Replace hydraulic hose to steering pump, port side, under emergency escape hatch in engine room (chaffed thru) LEGACY COMPONENT DESC: Hydraulic Hose
Due 29 July 2003
Resolved 1 August 2003
Construction/Loadline › Hull
Issued 3 July 2003
Resolved
Install means to prevent forward emergency escape hatch from holing life floats. LEGACY COMPONENT DESC: Escape Hatch
Due 29 July 2003
Resolved 1 August 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 July 2003
Resolved
Provide servicing report for fire detection/supression system including notations to fire anunceator in wheel house and heat sensors in engine room. LEGACY COMPONENT DESC: Servicing Report
Due 29 July 2003
Resolved 20 August 2003
Personnel › Training
Issued 3 July 2003
Resolved
Demonstrate fire drills and man over board drill. LEGACY COMPONENT DESC: Familiarization Training
Due 29 July 2003
Resolved 1 August 2003
Construction/Loadline › Hull › Side Shell
Issued 31 January 2003
Resolved
Prior to carrying passengers, make temporary repairs to fracture on port stern. Make permanent repairs prior to 20FEB03l
Due 20 February 2003
Resolved 13 September 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 2 July 2002
Resolved
Prior to carrying passengers/operation under current COI, vessel is to be inspected by USCG Marine Inspector for repairs made after port engine fire.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2002
Resolved 1 August 2002
Resolution: Estimated correction date.
Construction/Loadline › Hull
Issued 9 May 2002
Resolved
MAKE REPAIRS TO FRACTURED WELDS, PITS, SIDESHELL PLATING IN LAZERTTE AS MARKED (9 ITEMS MARKED).
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Electrical › Electric Supply System (service)
Issued 9 May 2002
Resolved
RENEW BROKEN BATTERY BOX ON P/S SSDG. LEGACY COMPONENT DESC: Battery Installation
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Electrical › Electric Generation Source (service)
Issued 9 May 2002
Resolved
RENEW 2 STRAINER BASKETS ON P & S SSDGs.
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Construction/Loadline › Structures
Issued 9 May 2002
Resolved
ADJUST TOP DOG ON AFT WATERTIGHT DOOR. LEGACY COMPONENT DESC: Door
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Construction/Loadline › Hull
Issued 9 May 2002
Resolved
MAKE REPAIRS TO FRACTURED WELDS, PITS, SIDE SHELL PLATING IN ENGINE ROOM AS MARKED (8 ITEMS).
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Construction/Loadline › Structures
Issued 9 May 2002
Resolved
ADJUST TWO FORWARD WTD TO ENSURE ADEQUATE SEAL. CHALK TEST FOR MARINE INSPECTOR.. LEGACY COMPONENT DESC: Door
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Construction/Loadline › Hull
Issued 9 May 2002
Resolved
MAKE REPAIRS TO FRACTURED WELDS AND RUPTURE IN WAY OF STEM IN FOREPEAK.
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Construction/Loadline › Hull
Issued 9 May 2002
Resolved
MAKE REPAIRS TO BROKEN WELD ON PORT SIDE VERTICAL SUPPORT AND BUCKLED FLANGE ON TRANSVERSE FRAME ON PORT SIDE IN CAPTAIN'S QUARTERS BILGE COMPARTMENT.
Due 9 June 2002
Resolved 24 May 2002
Resolution: Cited cleared 835.
Documentation
Issued 10 August 2001
Resolved
PROVIDE TRAINING LOG IAW 46 CFR 185.420.
Condition: Unknown
Due 10 August 2001
Resolved 17 September 2001
Accommodation/Occupational Safety
Issued 10 August 2001
Resolved
PROVE PROPER OPERATION OF MSD DISCHARGE VALVE AND PROVIDING MEANS OF SECURING IAW 33 CFR 159.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001
Resolved
RENEW WASTED BILGE SUCTION AND AC LINES THROUGHOUT BILGE.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001
Resolved
RENEW COOPER FRESH WATER LINES IWO SEWAGE TANK COMPARTMENT.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Fire Fighting
Issued 10 August 2001
Resolved
PROVE PROPER OPERATION OF #6 AND #3 VENTILATION CLOSURES IWO ENGINE ROOM.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Fire Fighting
Issued 10 August 2001
Resolved
PROVE PROPER OPERATION OF FIRE PUMP PRESSUE GUAGE IAW 46 CFR 181.300(B).
Condition: Unknown
Due 10 August 2001
Resolved 17 September 2001
Navigation
Issued 10 August 2001
Resolved
OBTAIN AND PROVE PROPER OPERATION OF NOT UNDER COMMAND LIGHTS.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 10 August 2001
Resolved
PROVE PROPER OPERATION OF PORTSIDE GENERATOR OVERCURRENT DEVICE IAW 46 CFR 183.320(F)
Condition: Unknown
Due 10 August 2001
Resolved 17 September 2001
Lifesaving
Issued 10 August 2001
Resolved
PROVIDE LIFEJACKETS LIGHTS FOR 10 LIFEJACKETS NOTED.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001
Resolved
INSTALL ESCAPE HATCH HOLD BACK DEVICES IAW 46 CFR 177.500(L)
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001
Resolved
MAKE AVAILABLE HULL UNDERNEATH TIRES FOR INSPECTION, CROP AND RENEW PORT AND STARBOARD HOLES IWO HULL AND DECK.
Condition: Unknown
Due 10 August 2001
Resolved 17 September 2001
Lifesaving
Issued 10 August 2001
Resolved
LATCH DOWN DEEP FREEZER IWO LOWER PASSENGER SPACE.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Electrical
Issued 10 August 2001
Resolved
REPAIR 12 VOLT BILGE ALARM CONNECTION IWO MAIN ENGINE STARBOARD SIDE HULL.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Accommodation/Occupational Safety
Issued 10 August 2001
Resolved
INSTALL SEA RAILS ON GALLEY RANGE IAW 46 CFR 184.220(E).
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Engineering
Issued 10 August 2001
Resolved
REPLACE CONTROL AIR LINES IWO ENGINE ROOM.
Condition: Unknown
Due 10 August 2001
Resolved 17 September 2001
Electrical
Issued 10 August 2001
Resolved
ELECTRICAL CABLES NEED TO BE PROPERLY SUPPORTED THROUGHOUT BILGES.
Condition: Unknown
Due 10 August 2001
Resolved 17 September 2001
Electrical
Issued 10 August 2001
Resolved
INSTALL GUARDS ON ALL LIGHT FIXTURES IWO ENGINE ROOM IAW 46 CFR 183.410(A).
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Construction/Loadline
Issued 10 August 2001
Resolved
CLEAN OUT ALL BILGE COMPARTMENTS.
Condition: Unknown
Due 10 August 2001
Resolved 17 September 2001
Construction/Loadline
Issued 10 August 2001
Resolved
REPAIR OR RENEW STUFFING TUBE WHERE WIRE PASSES THROUGH COLLISON BULKHEAD IWO SEWAGE TANK COMPARTMENT.
Condition: Unknown
Due 10 August 2001
Resolved 10 August 2001
Engineering
Issued 7 June 2000
Resolved
Install machinery guard for rotating belt on starboard engine.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Construction/Loadline
Issued 7 June 2000
Resolved
REPAIR FORWARD BILGE SUCTION VALVE REACH ROD IN FOREPEAK SPACE.
Condition: Unknown
Due 7 July 2000
Resolved 24 July 2000
Documentation
Issued 7 June 2000
Resolved
OBTAIN FCC RADIO STATION LICENSE.
Condition: Unknown
Due 6 July 2000
Resolved 12 July 2000
Lifesaving
Issued 7 June 2000
Resolved
REPLACE RESCUE LADDER WITH RESCUE PLATFORM OR RESCUE BOAT TO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 6 July 2000
Resolved 12 July 2000
Documentation
Issued 7 June 2000
Resolved
OBTAIN FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 6 July 2000
Resolved 12 July 2000
Engineering
Issued 7 June 2000
Resolved
REPAIR PORT AND CENTER OIL PRESSURE GAUGES FOR MAIN ENGINES.
Condition: Unknown
Due 6 July 2000
Resolved 12 July 2000
Lifesaving
Issued 7 June 2000
Resolved
Repair dogs on forward emergency escape hatch.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Lifesaving
Issued 7 June 2000
Resolved
PROCURE PADDLES FOR LIFEFLOATS AND ENSURE THEY ARE STENCILED IN ACCORDANCE WITH 46CFR180.175.
Condition: Unknown
Due 6 July 2000
Resolved 12 July 2000
Fire Fighting
Issued 7 June 2000
Resolved
PROCURE HAND FIRE PUMP IN ACCORDANCE WITH 46CFR181.10-5.
Condition: Unknown
Due 6 July 2000
Resolved 12 July 2000
Navigation
Issued 7 June 2000
Resolved
OBTAIN MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 6 July 2000
Resolved 30 June 2000
Fire Fighting
Issued 7 June 2000
Resolved
Ensure propulsion engine-driven bilge pump and electric fire/bilge pump arecapable of independent operation.
Condition: Unknown
Due 7 June 2000
Resolved 7 June 2000
Documentation
Issued 19 May 1995
Resolved
MAKE PERMANENT LOADLINE MARKINGS WITH DIMENSIONS AS SPECIFIED BY _x001C_ 46CFR42.13-25/30 IN POSITIONS AS SPECIFIED BY ABS LOADLINE CERTIFICATE #7907168-4 ISSUED 28FEB94.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Lifesaving
Issued 19 May 1995
Resolved
PERFORM ANNUAL SERVICING OF STARBOARD LIFERAFT HYDROSTATIC RELEASE OR RENEWSAME WITH NEW OR RECENTLY SERVICED RELEASE
Condition: Unknown
Due 19 May 1995
Resolved 7 June 1995
Lifesaving
Issued 31 May 1993
Resolved
MAXIMUM NUMBER OF PERSONS (PASSENGERS & CREW) LIMITED TO FIFTY TWO (52) UNTIL 100% LIFESAVING IS SUPPLIED ONBOARD. NOTIFY [name withheld] IN WRITING WHEN LIFESAVING IS SUPPLIED
Condition: Unknown
Due 31 May 1993
Resolved 31 May 1993
Engineering
Issued 30 April 1987
Resolved
MAKE OPERABLE THE WHEELHOUSE TACHOMETER FOR CENTER MDE, WATER TEMP GAGE FORPORT MDE, AND DRIVE OIL PRESSURE GAGES FOR PORT AND STBD MDE'S. COMPLIANCE DATE IS 30MAY87
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Accommodation/Occupational Safety
Issued 30 April 1987
Resolved
REPLACE EXISTING HOT WATER TANK RELIEF VALVE WITH ONE SET AT 100 PSI/210F OR MAKE TANK AVAILABLE FOR INTERNAL EXAMINATION. COMPLIANCE DATE IS 30MAY87
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 30 April 1987
Resolved
NEXT ANNUAL LIFERAFT SERVICING CONDUCT HYDROSTATIC TEST OF INFLATION CYLINDER NO. MM215975 ON 8FG RAFT 25 MMUS SERIAL NO. 5 LOT NO. 189. COMPLIANCE DATE IS 30MAY87
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Fire Fighting
Issued 28 February 1985
Resolved
REPAIR OR REPLACE BROKEN ELECTRICAL BOX FOR FIRE DETECTOR IN ENGIN ROOM
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Lifesaving
Issued 28 February 1985
Resolved
REINSTALL ALL CHAIN RAILINGS ON FANTAIL
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985
Navigation
Issued 28 February 1985
Resolved
REPAIR OR REPLACE FATHOMETER ON BRIDGE
Condition: Unknown
Due 28 February 1985
Resolved 28 February 1985