Records from 2009 to 2018. Most recent: inspection, 17 October 2018.
Inspection history · 9
17 October 2018
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6562935
16 October 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6553734
30 January 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6059265
8 September 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5229938
2 September 2015
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5232898
2 September 2015
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5233359
25 August 2014
PII Safety Exam · ISPS III Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4961140
12 August 2011
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4113329
22 April 2009
Ballast Water Examination · PII Safety Exam · ILO-147 Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3467210
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 October 2018
Resolved
EVERY SHIP SHALL BE PROVIDED WITH FIRE PUMPS, FIRE MAINS, HYDRANTS, AND HOSES COMPLYING AS APPLICABLE WITH THE REQUIREMENTS OF THIS REGULATION. PSCO NOTED (02) PIN HOLE LEAKS IN THE FIRE MAIN PIPING STARBOARD SIDE OF CARGO HOLD NO.4.
(74) SOLAS 97 II-2/4.1
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2018
Resolution: Energized the fire main and walked the maindeck to check the firemain repairs where an approximate three meter repair was made. Also noted small drip, may have been condensation in the repair. The vessel will test when dew and humidity is lifted.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 8 September 2015
Resolved
15 ac - 0799 - Class "A" boundary - The minimum fire integrity of bulkheads and decks shall be as prescribed in Tables 44.1 and 44.2. Service window in galley identified as a Class A boundary will not close. 74 SOLAS (97) II-2 / 44.1.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 11 November 2015
Resolution: Received class report from ClassNK attesting to repairs made to service window.
Lifesaving › Lifeboat › Rigid Cover
Issued 2 September 2015
Resolved
0600: Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. Lifeboat was punctured and lifeboat davit was bent during allision with another vessel. 74SOLAS(09)CH.III/17. 17ac
Action required: 705 - Other - as specified
Due 6 December 2015
Resolved 30 January 2017
Resolution: Vessel attended by NKK representative on 20NOV2015 to survey and attest to repairs made to port side lifeboat and port side lifeboat davit. All repairs were completed to the satifaction of NKK as indicated on class report provided to PSC officers.
Construction/Loadline › Hull › Hull Plating
Issued 2 September 2015
Resolved
1299: Whenever an accident occyres to a ship the master or owner of the ship shall report at the earliest opportunity to the Administration. Vessels hull was damaged in 02 locations and the port side bridge wing was damaged following an allision witih another vessel. 74SOLAS(09)Ch.I/11, 17ac
Action required: 17 - Rectify deficiencies prior to departure
Due 5 September 2015
Resolved 6 September 2015
Resolution: Receieved class report issuing condition of class to damage to hull plating and bridge wing. See attached class report.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 22 April 2009
Resolved
Switchboard in engine room did not have non conducting mats on the front side.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 April 2011
Resolution: FFVE verified switchboard in engine has non conducting mats on the front side.
Fire Fighting › Means of Escape › Blocked
Issued 22 April 2009
Resolved
Freon cylinder in steering gear room improperly stowed. Potentially blocking emergency escape.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 April 2011
Resolution: FFVE verified that emergency escapes were not blocked.