← All vessels
SARA F MCCALL
SARA F MCCALL is a 1999 offshore supply vessel. The Coast Guard has recorded 31 inspections since 1999, most recently in August 2014, along with 87 deficiencies and 1 casualty investigation in 2013.
Records from 1999 to 2014. Most recent: inspection, 20 August 2014.
- Built
- 1999
- Last inspected
- 20 August 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 87 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2013
Identity
1087451
9224374 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE8278
504403
Flag
UNITED STATES
338190000 (licence lapsed)
Maury page id
psix-504403
Inspections, by type
…with no type recorded3
Years with a record
12 calendar years (1999–2014)
The 31 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it138 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
462 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
462 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDE8278MMSI 338190000 · cancelled · compulsorily equipped · granted 9 April 2009, cancelled 10 December 2015
WDB6861MMSI 338190000 · cancelled · compulsorily equipped · granted 16 March 2004, cancelled 7 April 2009
WCZ6105MMSI 338190000 · cancelled · compulsorily equipped · granted 30 December 1999, cancelled 24 March 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 31
20 August 2014
MARPOL Annex I Examination · MTSA/ISPS Verification · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4959538
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200270
18 July 2011
Administrative Inspection · Annual Inspection · Internal Structural Exam · Hull Examination · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4087256
15 December 2008
Annual Inspection
Physical examination · Activities Europe · Activity 3481082
14 July 2008
Administrative Inspection
Administrative · Activities Europe · Activity 3267366
27 February 2008
Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 3155251
21 October 2007
Hull Examination
Physical examination · Activities Europe · Activity 3076649
29 September 2006
Periodic Inspection
Physical examination · Activities Europe · Activity 2776292
16 June 2006
Administrative Inspection
Administrative · Activities Europe · Activity 2702002
8 March 2006
Annual Inspection
Physical examination · Activities Europe · Activity 2589620
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571523
16 October 2005
Hull Examination
Physical examination · Activities Europe · Activity 2532121
18 April 2005
Administrative Inspection
Administrative · Activities Europe · Activity 2415544
4 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303753
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290174
2 February 2005
Deficiency Check · COI Inspection
Physical examination · Activities Europe · Activity 2226769
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232656
2 September 2004
Deficiency Check
Physical examination · Activities Europe · Activity 2183974
24 July 2004
Type not recorded
No type recorded · Activities Europe · Activity 2315087
15 June 2004
MTSA/ISPS Verification
Physical examination · Activities Europe · Activity 2058925
11 June 2004
Type not recorded
No type recorded · Activities Europe · Activity 2095160
24 May 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2076783
23 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971754
12 December 2003
Annual Inspection
Physical examination · Activities Europe · Activity 1968150
3 November 2003
Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 1880564
9 June 2003
Administrative Inspection · Plan Review "T" Boat
Administrative · Activities Europe · Activity 1813348
10 September 2002
Annual Inspection
Physical examination · Activities Europe · Activity 1673374
19 March 2002
Administrative Inspection
Administrative · Activities Europe · Activity 1494616
26 October 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444645
2 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046870
10 December 1999
Initial Certification · Hull Examination · Inclining Experiment · Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412034
Deficiency record · 87
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 December 2008
Resolved
Proved proof of the OWS has been calibrated and is being used. Received e-mail 20Mar advising corrected and extended due date to next annual.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 15 December 2008
Resolved
Proved proof of the SMPEP approval Letter and annual audit has been conducted. Recieved copy of the new PCV-1 approval letter.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 15 December 2008
Resolved
Proved proof of the Main electrical switchboard have Ground detection meter being replaced or repaired and all light covers repaired. Received e-mail 20Mar advising corrected and extended due date to next annual.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 December 2008
Resolved
Proved proof of the of the replacement of the damaged center propulsion staff. Recieved request to extend to dd.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 15 December 2008
Resolved
Proved proof of the bridge forward control three center MDE RPM Tachometers being repaired or replaced. Received e-mail 30Mar advising corrected and extended due date to next annual.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 15 December 2008
Resolved
Proved proof of the Starboard forward MDE RPM indicator being repaired.Received e-mail 03Mar advising corrected and extended due date to next annual.
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 December 2008
Resolved
Proved proof of the of the Port radar having been replaced. Received e-mail 22Mar advising corrected and extended due date to next annual.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 February 2008
Resolved
Make repairs to all damaged state room rack lighters. Received e-mail 07 April advising corrected and extended due date to next annual.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 February 2008
Resolved
Repairs damage overhead light cover in crew state room. Received e-mail 07 April advising corrected and extended due date to next annual.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 27 February 2008
Resolved
Update all documents to show new Owner.
Electrical › Electric Supply System (service) › Cable
Issued 27 February 2008
Resolved
Make permanent repairs to cable hangers in forward storage room. Received e-mail 07 April advising corrected and extended due date to next annual.
Fire Fighting › Fire Hoses › Condition
Issued 27 February 2008
Resolved
Provide new UL approved fire hose for fire stations #s 4, 5 and 14 that work with the hose connection at the fire stations. Received e-mail 12 June advising corrected and extended due date to next annual.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 24 October 2007
Resolved
Provide manuals and drawings for fixed fire fighting system to be used during annual servicing.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 24 October 2007
Resolved
Replace leaking temperature plugs in wet exhaust starboard side forward.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Engineering › Bilge Water Management System › Valve
Issued 24 October 2007
Resolved
Replace broken ball valve in way of waste oil pump suction line.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 24 October 2007
Resolved
Provide copy of shaft wear readings and ABS ruling.
Item pending ABS report.
Engineering › Thrusters › Motor
Issued 24 October 2007
Resolved
Provide copy of technical report attesting to proper installation of bow thruster.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 October 2007
Resolved
Provide copy of service report for fixed CO2 system.
Pending Service report
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 24 October 2007
Resolved
Replace fill valves in fuel day tank and ballast tanks number 2 and 3.
Item reported clear via E-mail dated 07 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 October 2007
Resolved
Provide U.S. Coast Guard approved alcohol testing kits or prove that required testing can be conducted within 2 hours while in all operations.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 21 October 2007
Resolved
Replace CO2 diffuser starboard side in generator room.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 October 2007
Resolved
Provide proper battery storage for batteries in generator flat port side.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 21 October 2007
Resolved
Replace missing sight glass in way of waste oil tank port side engine room aft and renew broken / modified sight glass in way of washer and dryer starboard side.
Item reported clear via E-mail dated 14 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 21 October 2007
Resolved
Repair all fire dampers on ventilation including bolts to hold sliding dampers and replacing gasket material.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Construction/Loadline › Penetrations › Valve Flange
Issued 21 October 2007
Resolved
Replace wasted spool pieces on 5 each 4.5 inch sea valves prior to vessel leaving dry dock.
Engineering › Fuel Oil Service System › Tank
Issued 21 October 2007
Resolved
Provide ABS documentation that cracks found in tanks have been repaired and tanks have been hydrostatically tested.
Item reported clear via E-mail dated 7 Dec 07 and shall remain open until verified to be corrected by attending USCG Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 29 September 2006
Resolved
Replace missing fire extinguishers prior to departure from port.
Communications › Radio Communications › Satellite Communications Capability
Issued 29 September 2006
Resolved
Prove proper operation of GMDSS: 12 volt battery back up system & SSB. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 September 2006
Resolved
Install screens on potable water vents. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 September 2006
Resolved
Provide proof of current random drug testing program. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Communications › Radio Communications › EPIRB
Issued 29 September 2006
Resolved
Provide new antenna and NOAA registration sticker for the EPIRB. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 September 2006
Resolved
Install corrosion resistant slips on lines between ring life buoys and waterlights. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Lifesaving › Launching Appliances › Falls
Issued 29 September 2006
Resolved
Conduct weight test on rescue boat davit with 110% of full weight. Falls were renewed in May 2006. Test may be witnessed by ABS or Coast Guard Inspectors. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify the documentation.
Lifesaving › Lifebuoys › Serviceable
Issued 29 September 2006
Resolved
Remove cracked ring life buoy on the main deck, port side aft & provide new ring buoy. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Fire Fighting › Fire Hoses › Condition
Issued 29 September 2006
Resolved
Provide new fire hose to replace the holed hose at fire station #5. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 29 September 2006
Resolved
Install proper flame screens on fuel tank vents on the main deck. 20x20 mesh screens must have 2 screens. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 29 September 2006
Resolved
Remove the steel bolt in the bronze sea chest (port forward) and install a bronze bolt. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 29 September 2006
Resolved
Provide alcohol sensor for alcohol testing within 2 hours of a marine incident. 23OCT06: Rcvd email from master stating that this item has been cleared. Extended the due date to the end of the next annual window so an inspector can verify.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 16 June 2006
Resolved
Have manufacturer representative test proper operation of all main diesel engine low lube oil shutdowns and high water temp alarms and provide copy of the servicing report to cognizant OCMI.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 9 March 2006
Resolved
Make repairs to center main engine alarm panel in the bridge and prove proper operation. Rcvd email dated 5/5/06 stating requirement complete. Extended deadline one year until onboard verification can be completed.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 9 March 2006
Resolved
Make repairs to port aux generator low lube oil pressure shutdown and prove proper operation. Rcvd email dated 5/5/06 stating requirement complete. Extended deadline one year until onboard verification can be completed.
Lifesaving › Rescue Boat Equipment › First Aid Kit
Issued 9 March 2006
Resolved
Replace expired medicine on first aid kit for the rescue boat. Rcvd email dated 5/5/06 stating requirement complete. Extended deadline one year until onboard verification can be completed.
Lifesaving › Rescue Boat Equipment › Searchlight
Issued 9 March 2006
Resolved
Replace missing search light and safety knife for the rescue boat. Rcvd email dated 5/5/06 stating requirement complete. Extended deadline one year until onboard verification can be completed.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 9 March 2006
Resolved
Provide vessel with machinery automation test procedure as required by 46 CFR 130.480 and to comply with 46 CFR 127.110(f).
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 2 February 2005
Resolved
Hydro test or replace 15 pound CO2 extinguishers.
Based on email dated 09 March 2005 extended deadline two months while parts are on order.
/s/ [name withheld]
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 2 February 2005
Resolved
Provide CG approved CO2 bottles for paint lockers.
Based on email dated 24 March 2005 extended deadline two months while parts are on order.
/s/ [name withheld]
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 February 2005
Resolved
Replace or recharge fire extinguisher near rear door of passenger cabin.
Based on email dated 09 March 2005 extended deadline two months while parts are on order.
/s/ [name withheld]
Lifesaving › Launching Appliances › Release Mechanism
Issued 2 February 2005
Resolved
Replace EPIRB hydrostatic release.
Based on email dated 09 March 2005 extended deadline two months while parts are on order.
/s/ [name withheld]
Accommodation/Occupational Safety › Ventilation › General
Issued 2 February 2005
Resolved
Clean coils and prove proper operation of bridge air conditioning unit.
Received email dated 24 Feb 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Lifesaving › Rescue Boat › Markings
Issued 2 February 2005
Resolved
Prove proper operation of Zodiac navigation lights.
Received email dated 24 Feb 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Lifesaving › Launching Appliances › Davit
Issued 2 February 2005
Resolved
Prove proper operation of Zodiac davit limit switch.
Received email dated 09 Mar 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Electrical › Electrical Distribution System (service) › Switchboard
Issued 2 February 2005
Resolved
Prove proper operation of switchboard lights.
Received email dated 24 Feb 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 2 February 2005
Resolved
Correctly repair leaking plugs on jacket water coolers on inboard port and center main engines.
Based on email dated 09 March 2005 extended deadline two months while parts are on order. /s/ [name withheld]
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 2 February 2005
Resolved
Prove proper operation of low lube oil alarm on stbd inboard main engine.
Received email dated 09 Mar 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Stability › Watertight Integrity › General
Issued 2 February 2005
Resolved
Install missing sea chest valve handles on all five main engines.
Received email dated 24 Feb 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 February 2005
Resolved
Submit Fire Safety Plan for review and approval. Plan submitted in 2004 does not include all systems listed in 46 CFR 131.945.
7 March 2005: Received Fire Safety Plan for review. Deficiency complete. Compliance date extended one year until plan can be reviewed and verified onboard.
Lifesaving › Launching Appliances › Davit
Issued 2 February 2005
Resolved
End for end rescue craft falls and conduct 110% weight test (((number of persons allowed in rexcue craft X 165 pounds) + weight of FRC) X 110). Note this requirement issued administratively after review of casework.
Received email dated 09 Mar 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 December 2003
Resolved
Ensure Master logs service of vessel as per Eighth Coast Guard District policy letter.
Received email dated 24 Feb 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 December 2003
Resolved
Ensure required log entries (46 CFR 131.620) are entered as required.
Received email dated 24 Feb 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 13 December 2003
Resolved
Ensure fuel vents have flame screens with back flow preventer.
Received email dated 24 Feb 2005 stating requirement complete. Extended deadline one year until onboard verification can be completed. /s/ [name withheld]
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 December 2003
Resolved
Provide proof of automation test (overspeed, low lube oil, high temp) for generators. Must state set points for alarms, as per manufacturer requirements, and test results stating when alarm sounded.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 12 December 2003
Resolved
ENSURE ALL LIFEJACKETS ARE SOLAS/CG APPROVED (39 NON-SOLAS).
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 12 December 2003
Resolved
WHEN OPERATING AS A "T-BOAT" THE NUMBER OF PASSENGERS IS REDUCED FROM 75 TO 36 UNTIL ALL LIFEJACKETS ARE SOLAS/CG APPROVED (39 NON-SOLAS LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 December 2003
Resolved
SUBMIT NEW FIRE/SAFETY PLAN FOR APPROVAL. LEGACY COMPONENT DESC: Fire Control Plans
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 12 December 2003
Resolved
ENSURE ALL LIFE JACKET LIGHTS ARE PROPERLY MOUNTED ON TOP OF JACKET LEGACY COMPONENT DESC: Lights
Accommodation/Occupational Safety › Sleeping Accommodations › People Per Room
Issued 12 December 2003
Resolved
REMOVE 2 ADDITIONAL BUNKS (6 BUNKS) FROM THE 4 STATEROOM, MAIN PASSENGER DECK. LEGACY COMPONENT DESC: Area Per Person
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 12 December 2003
Resolved
ENSURE FUEL VENTS HAVE FLAME SCREENS WITH BACK FLOW PREVENTOR.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 12 December 2003
Resolved
PROVIDE SECOND JACOBS LADDER FOR EMBARKATION STATIONS LEGACY COMPONENT DESC: Accessability
Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 12 December 2003
Resolved
PROVE PROPER OPERATION OF DAVIT. (UNABLE TO LOWER/RAISE WITH POWER, BAD SWITCH).
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 12 December 2003
Resolved
PROPERLY MARK EMERGENCY EXITS (LETTERS MUST BE 2" IN HEIGHT)
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 December 2003
Resolved
PROVIDE PROOF OF AUTOMATION TEST (OVERSPEED, LOW LUBE OIL, HIGH TEMP) FOR GENERATORS. MUST STATE SET POINTS FOR ALARMS, AS PER MANUFACTURE REQUIREMENTS, AND TEST RESULTS STATING WHEN ALARM SOUNDED.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 12 December 2003
Resolved
PROVIDE PROOF OF FIRE DETECTION SYSTEM. MUST STATE THAT THE SMOKE AND HEAT SENSORS WERE TESTED AND ALL ALARMS FUNCTIONED.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 12 December 2003
Resolved
ENSURE LINE THROWING GUNS HAS 4 LINE CARTRIDGES (HAS 3 ONBOARD). LEGACY COMPONENT DESC: Lines
Navigation › Piloting/Steering › Compass Deviation Table
Issued 12 December 2003
Resolved
ENSURE VESSEL HAS A CURRENT COMPASS DEVIATION CARD.
Engineering › Fuel Oil Service System › Valve, Control
Issued 12 December 2003
Resolved
MARK EMERGENCY FUEL SHUTDOWNS WITH "PULL" TO INDICATE DIRECTION FOR OFF.
Engineering › Fuel Oil Service System › Valve, Control
Issued 12 December 2003
Resolved
PROPERLY MARK PORT EMERGENCY FUEL SHUTDOWN
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 December 2003
Resolved
REMOVE DEAD -END WIRE GALLEY BY SPEAKER AFT BULKHEAD.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 12 December 2003
Resolved
PROPERLY BRACE BATTERIES FOR EMERGENCY POWER TO PREVENT MOVEMENT IN BATTERY BOX.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 November 2003
Resolved
1. Bilge alarm missing for the bow thruster space, renew bilge alarm and prove proper operation. LEGACY COMPONENT DESC: Bilge Alarm
Operations/Management › Drills/Instruction › Fire
Issued 5 November 2003
Resolved
2. Letter "B" referenced in release instructions for the bow thruster space fixed CO2 System missing from valve identified. Renew and properly affix letter "B". LEGACY COMPONENT DESC: Fire
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 November 2003
Resolved
3. Sea water cooling lines for the main engine cooling water system wasted, holed and temporarily patched. Renew wasted and holed sea water cooling lines and prove proper operation. LEGACY COMPONENT DESC: Piping
Lifesaving › Launching Appliances › Davit
Issued 5 November 2003
Resolved
4. Non U. S. Coast Guard Approved rescue boat davit installed on board. Provide U. S. Coast Guard Approved Davit/Winch and Approved Plans. LEGACY COMPONENT DESC: Davit
Construction/Loadline › Hull › Hull Plating
Issued 5 November 2003
Resolved
5. Side shell damage: crop and renew holed port side shell in way of steering gear space, crop and renew holed side shell starboard in way of #2 fuel tank and #6 water tank. LEGACY COMPONENT DESC: Side Shell
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 5 November 2003
Resolved
6. NDT and take bearing wear down clearances for tail shafts. Provide copy of the report to U. S. Coast Guard Marine Inspection Office Europe.
Engineering › Thrusters
Issued 10 September 2002
Resolved
Supply hoses for hyd. bowthruster are blocking emergency egress. Re-route hoses. LEGACY COMPONENT DESC: Hose
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 29 August 2002
Resolved
Recharge or replace 15 lb. dry chem fire extinguisher located in crew/passenger qtrs.
Documentation
Issued 2 March 2000
Resolved
Required to have a Coast Guard approved Shipboard Oil Pollution Emergency Plan (SOPEP) iaw 33CFR151.26.
Casualty record · 1
9 July 2013Routine · role: Involved in a Marine Casualty · activity 4650554
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.