MAURY USCG vessel records Sign in
← All vessels

CHARLES F MCCALL

CHARLES F MCCALL is a 2000 offshore supply vessel. The Coast Guard has recorded 23 inspections since 2000, most recently in July 2007, along with 16 deficiencies.

Records from 2000 to 2007. Most recent: inspection, 23 July 2007.

Built
2000
Last inspected
23 July 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9232838 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDD8848
504404
Flag
UNITED STATES
338232000 (licence lapsed)
Maury page id
psix-504404

Inspections, by type

…with no type recorded5
Years with a record 8 calendar years (2000–2007)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
138 - Convention (Subpart B), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
462 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD8848MMSI 338232000 · cancelled · compulsorily equipped · granted 18 July 2007, cancelled 21 April 2009
WDB7401MMSI 338232000 · cancelled · compulsorily equipped · granted 21 April 2004, cancelled 16 July 2007
WCZ8403MMSI 338232000 · cancelled · compulsorily equipped · granted 25 May 2000, cancelled 3 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ST. FRANCIS Commercial Fishing Vessel · MISLE 421186 · 18 August 2001 · activity 52639

Inspection history · 23

23 July 2007 MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex II Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3004596
15 June 2007 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2962368
2 February 2007 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2866547
9 May 2006 Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2644430
20 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2570225
27 May 2005 COI Inspection · MTSA Verification
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2368172
3 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303016
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290072
5 January 2005 Damage Survey · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2269135
5 January 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2272226
28 October 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2230305
3 June 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2087370
27 April 2004 Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2053542
15 March 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2024989
5 August 2003 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1867355
16 May 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1615984
27 August 2001 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413994
18 August 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 52639
8 May 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393676
3 May 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 526641
26 April 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 482920
19 October 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1055085
7 June 2000 Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365885

Deficiency record · 16

Electrical › Electric Generation Source (service) › Generator
Issued 9 May 2006 Resolved
Clean generator armatures.
Condition: Improper Installation
Due 23 June 2006
Resolved 18 June 2007
Communications › Alarms/Indicators › General Alarm
Issued 9 May 2006 Resolved
Demonstrate compliance with requirement for General Alarm (46 CFR 133.170)
Condition: Improper Installation
Due 23 June 2006
Resolved 18 June 2007
Lifesaving › Line-Throwing Appliances › Lines
Issued 9 May 2006 Resolved
Provide required auxiliary line for line throwing gun.
Condition: Improper Installation
Due 23 June 2006
Resolved 18 June 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 9 May 2006 Resolved
clean exhaust fan, port side generator room.
Condition: Improper/Lack of Maintenance
Due 23 June 2006
Resolved 18 June 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 May 2006 Resolved
Provide alternate location instructions for CO2 activation station.
Condition: Improper Installation
Due 23 June 2006
Resolved 18 June 2007
Fire Fighting › Means of Escape › Blocked
Issued 9 May 2006 Resolved
RE-arrange hydraulic hoses for drop down thruster so as not to block the emergency escape.
Condition: Improper Installation
Due 23 June 2006
Resolved 18 June 2007
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 9 May 2006 Resolved
Tighten shaft packing.
Due 23 June 2006
Resolved 18 June 2007
Construction/Loadline › Hull › Side Shell
Issued 5 January 2005 Resolved
Vsl to proceed directly to Bolinger ship yard, Texas City, TX. Make permanent repairs to #2 stbd fuel tank. Repairs to be made to the satisfaction of attending C.G. inspector and prior to putting vsl back in service.
Action required: 705 - Other - as specified
Resolved 6 January 2005
Resolution: Cropped and re-newed an 18" by 30" insert.
Lifesaving › Buoyant Apparatus › Self-igniting Lights
Issued 16 May 2002 Resolved
REPAIR/ REPLACE 06 LIFE FLOAT WATERLIGHTS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2002
Resolved 16 May 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2002 Resolved
INSTALL EXHAUST LAGGING ON ALL MDE EXHAUST PIPING
Condition: Improper Installation
Due 16 May 2002
Resolved 16 May 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2002 Resolved
INSTALL PROPER MARINE CABLE ON OIL BLENDER PUMPS
Condition: Improper Installation
Due 16 May 2002
Resolved 16 May 2002
Fire Fighting › Nozzles
Issued 16 May 2002 Resolved
INSTALL PROPER FIRE NOZZLE ON THE PORT AFT FIRE STATION.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2002
Resolved 16 May 2002
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 16 May 2002 Resolved
PROVIDE AND POST PASSENGER SHIP RADIO TELEPHONY CERTIFICATE
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2002
Resolved 16 May 2002
Construction/Loadline
Issued 27 August 2001 Resolved
PROCEED DIRECTLY TO SHIPYARD VIA GICW TO MAKE REPAIRS TO 4FT X 8FT SECTION OF PORT SIDE SHELL, PORT BULWARKS, AND PORT MAIN DECK. REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Fire Fighting
Issued 7 June 2000 Resolved
Prior to the carriage of passengers or cargo, conduct a man overboard, abandon ship, and fire fighting drill as required by 46 CFR 185.57 and 46 CFR 185.524.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000
Navigation
Issued 7 June 2000 Resolved
Provide on board a compass calibration card.
Condition: Unknown
Due 24 July 2000
Resolved 24 July 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.