Records from 2016 to 2026. Most recent: inspection, 20 July 2026.
Inspection history · 24
20 July 2026
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8439522
29 July 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8197534
14 June 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8159220
7 May 2025
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8130315
1 May 2025
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8117871
30 January 2024
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7857905
24 January 2024
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7845950
11 June 2023
PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7710816
9 June 2023
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7710346
5 October 2022
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7568036
21 April 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7435742
30 March 2022
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7420837
30 March 2022
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7421688
29 September 2021
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7322836
14 June 2021
In-Service Inspection · Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7225485
29 March 2021
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7164538
21 September 2020
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7062037
27 February 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6917033
15 February 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6909650
14 February 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6910719
26 September 2018
ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6546062
4 June 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6161294
25 August 2016
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5980224
26 February 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5822852
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 May 2025
Resolved
...Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. PSCO observed one category A fire door from the engine room to the main stairway was incapable of latching due to broken latch.
74 SOLAS (2001) II-2/47.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 7 May 2025
Resolution: Class survey report states the broken latch on the mentioned Engine Control Room door was renewed. The gastight condition and self-closing function for that door were surveyed satifactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 May 2025
Resolved
Oil fuel lines shall be screened or otherwise suitably protected to avoid as far as practicable, oil spray or oil leakages onto hot surfaces. PSCO observed two sections of pipes that were missing lagging in the purifier space.
74 SOLAS (2001) II-2/15.2.11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 7 May 2025
Resolution: Class survey report states the missing lagging on the mentioned pipes in the ship's Purifier Room was installed and surveyed satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 January 2024
Resolved
SOLAS 74 (88) I/11; After any survey of the ship under regulations 7,8,9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration.
PSCO observed questionable repairs of cargo deck 06/main deck into steering gear room. It appears repairs were made by a combination of sealant on the top and bracing with bolts. While discharging heavy machinery, as cargo, PSCO noticed the overhead of sterring gear room flex as much as two inches. When questioned, crew could not provide class approval for the repairs.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 February 2024
Resolved 30 January 2024
Resolution: Sector Puget Sound recieved documentation from class attesting to approved repairs of cargo deck 06/main deck into steering gear room. See documents tab for more information.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 June 2023
Resolved
11104 - Rescue Boats
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed that the rescue boat will not start due to broken fuel pump.
SOLAS (20) III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2023
Resolution: Condition of Class (LLOYD'S REGISTER) has been issued for inoperable rescue boat. Dispensation letter and short term Cargo Equipment Cert issued.