Records from 1985 to 1989. Most recent: inspection, 28 December 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
28 December 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916826
7 October 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890061
2 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028033
28 October 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329063
21 October 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018113
7 October 1987
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015313
23 September 1987
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326098
4 October 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008152
17 January 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286015
Fire Fighting
Issued 7 October 1988
Resolved
PROVIDE INSPECTION RECORDS AND TEST REPORTS FOR FIXED AND PORTABLE FIRE EXTINGUISHING SYSTEMS.
Condition: Unknown
Due 2 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 October 1988
Resolved
PROVE PROPER OPERATION OF #1 & 2 S/S GENERATORS REVERSE POWER RELAYS. PROVIDE LOG ENTRIES ENDORSED BY MASTER OF SATISFACTORY TESTING OF SAME.
Condition: Unknown
Due 2 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 7 October 1988
Resolved
PROVE HIGH PRESSURE CYLINDERS MEET 46CR 147.60 (A)(1) & (2) OR THE WAIVER GRANTED BY USCG CMDT LETTER 16703/46CFR 147.
Condition: Unknown
Due 31 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 October 1987
Resolved
PROVIDE 3 REPLACEMENT RING BUOYS AND 96 FEET OF LINE ATTACHED TO AT LEAST ONE RING BUOY ON EACH SIDE OF VESSDL.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987
Resolved
REPLACE INOPRABLE EMERGENCY LIGHTS LOCATED ON FORWARD GALLEY BULKHEAD AND PORT BOAT DECK.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Navigation
Issued 7 October 1987
Resolved
REPLACE INOPERABLE SOUND POWERED PHONE AT AFTER STEERING STATION.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Fire Fighting
Issued 7 October 1987
Resolved
HYDROSTATICALLY TEST OR REPLACE WITH APPROVED MODEL, THE PAINT LOCKER CO2 BOTTLE.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Navigation
Issued 7 October 1987
Resolved
REPLACE NAVIGATION LIGHT SYSTEM WITH DUAL SOURCE SYSTEM MANDATED BY CURRENTCG ELECTRICAL REQUIREMENTS.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987
Resolved
ENSURE PROPER OPERATION OF PART MDE OVERSPEED TRIP.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987
Resolved
REPLACE INOPERABLE HIGH LUBE OIL TEMP SENSORS ON BOTH MDE'S AND PORT REDUCTION GEAR.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987
Resolved
REPLACE, WITH APPROVED MODELS, THE SAFETY VALVES FOR BOTH ENGINE ROOM AIR RECEIVERS.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Lifesaving
Issued 7 October 1987
Resolved
PROVIDE CLIPS FOR 2 PFD'S MISSING SOME AND PROVIDE ONE ADDITIONAL USCG APPROVED PFD SO THAT VESSEL HAS TOTAL COMPLEMENT OF 20 JACKETS.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987
Resolved
REPLACE INOPERAABLE HIGH LUBE OIL TEMP SENSORS ON BOTH GENERATORS AND HIGH JACKET WATER TEMP SENSOR ON PART GENERATOR.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987
Resolved
REPAIR OR REPLACE STAND-BY BILGE PUMP.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987
Resolved
ENSURE PROPER OPERATION OF OVERSPEED TRIPS FOR BOTH GENERATORS
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987
Resolved
REPLACE AND ENSURE PROPER OPERATION OF MAIN SWITCHBOARD REVERSE POWER RELAY.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Fire Fighting
Issued 7 October 1987
Resolved
PROVIDE AND INSTALL SIX ANSUL-TYPE EXTINGUISHER BRACKETS TO ACCOMODATE PORTABLE EXTINGUISHERS IN ENGINE ROOM.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987