MAURY USCG vessel records Sign in
← All vessels

GULF FLEET NO. 36

GULF FLEET NO. 36 is a 1979 offshore supply vessel. The Coast Guard has recorded 9 inspections since 1985, most recently in December 1989, along with 18 deficiencies.

Records from 1985 to 1989. Most recent: inspection, 28 December 1989.

Built
1979
Last inspected
28 December 1989
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7914597 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WQZ4519
Flag
VANUATU
—
Maury page id
psix-50450

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (1985–1989)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it196 - Regulatory (Subpart C or D), Net Ton
289 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

28 December 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916826
7 October 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 890061
2 December 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028033
28 October 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329063
21 October 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1018113
7 October 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1015313
23 September 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326098
4 October 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008152
17 January 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1286015

Deficiency record · 18

Fire Fighting
Issued 7 October 1988 Resolved
PROVIDE INSPECTION RECORDS AND TEST REPORTS FOR FIXED AND PORTABLE FIRE EXTINGUISHING SYSTEMS.
Condition: Unknown
Due 2 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 October 1988 Resolved
PROVE PROPER OPERATION OF #1 & 2 S/S GENERATORS REVERSE POWER RELAYS. PROVIDE LOG ENTRIES ENDORSED BY MASTER OF SATISFACTORY TESTING OF SAME.
Condition: Unknown
Due 2 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 7 October 1988 Resolved
PROVE HIGH PRESSURE CYLINDERS MEET 46CR 147.60 (A)(1) & (2) OR THE WAIVER GRANTED BY USCG CMDT LETTER 16703/46CFR 147.
Condition: Unknown
Due 31 January 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 7 October 1987 Resolved
PROVIDE 3 REPLACEMENT RING BUOYS AND 96 FEET OF LINE ATTACHED TO AT LEAST ONE RING BUOY ON EACH SIDE OF VESSDL.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987 Resolved
REPLACE INOPRABLE EMERGENCY LIGHTS LOCATED ON FORWARD GALLEY BULKHEAD AND PORT BOAT DECK.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Navigation
Issued 7 October 1987 Resolved
REPLACE INOPERABLE SOUND POWERED PHONE AT AFTER STEERING STATION.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Fire Fighting
Issued 7 October 1987 Resolved
HYDROSTATICALLY TEST OR REPLACE WITH APPROVED MODEL, THE PAINT LOCKER CO2 BOTTLE.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Navigation
Issued 7 October 1987 Resolved
REPLACE NAVIGATION LIGHT SYSTEM WITH DUAL SOURCE SYSTEM MANDATED BY CURRENTCG ELECTRICAL REQUIREMENTS.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987 Resolved
ENSURE PROPER OPERATION OF PART MDE OVERSPEED TRIP.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987 Resolved
REPLACE INOPERABLE HIGH LUBE OIL TEMP SENSORS ON BOTH MDE'S AND PORT REDUCTION GEAR.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987 Resolved
REPLACE, WITH APPROVED MODELS, THE SAFETY VALVES FOR BOTH ENGINE ROOM AIR RECEIVERS.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Lifesaving
Issued 7 October 1987 Resolved
PROVIDE CLIPS FOR 2 PFD'S MISSING SOME AND PROVIDE ONE ADDITIONAL USCG APPROVED PFD SO THAT VESSEL HAS TOTAL COMPLEMENT OF 20 JACKETS.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987 Resolved
REPLACE INOPERAABLE HIGH LUBE OIL TEMP SENSORS ON BOTH GENERATORS AND HIGH JACKET WATER TEMP SENSOR ON PART GENERATOR.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987 Resolved
REPAIR OR REPLACE STAND-BY BILGE PUMP.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987 Resolved
ENSURE PROPER OPERATION OF OVERSPEED TRIPS FOR BOTH GENERATORS
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Engineering
Issued 7 October 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Electrical
Issued 7 October 1987 Resolved
REPLACE AND ENSURE PROPER OPERATION OF MAIN SWITCHBOARD REVERSE POWER RELAY.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987
Fire Fighting
Issued 7 October 1987 Resolved
PROVIDE AND INSTALL SIX ANSUL-TYPE EXTINGUISHER BRACKETS TO ACCOMODATE PORTABLE EXTINGUISHERS IN ENGINE ROOM.
Condition: Unknown
Due 7 October 1987
Resolved 7 October 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.