Records from 2004 to 2025. Most recent: inspection, 8 May 2025.
Inspection history · 15
8 May 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8131385
29 December 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8051564
3 June 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7926444
21 January 2024
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7859379
28 June 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7725459
2 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7631088
10 August 2022
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7543542
22 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7231670
19 March 2020
Drydock Exam · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6929292
1 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6674098
3 March 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6367049
30 January 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6346444
22 January 2018
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6341229
17 January 2017
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6072044
10 May 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5873715
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2024
Resolved
Electrical equipment and installations must be suitable for the roll, pitch and vibrations of the vessel underway.
Small battery needs bracing to prevent movement within the enclosure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 20 June 2024
Resolution: 2X4 piece of wood was cut and use to fill empty space of battery container.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 3 June 2024
Resolved
Exposed hazards, such as gears or rotating machinery, must be properly protected by a cover, guard, or rails.
Front of both generators, front of both MDEs, and starter/jacking gear hole on both MDEs need covers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 20 June 2024
Resolution: Guards installed, sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 June 2024
No resolution recorded
Name of the vessel and hailing port shall be marked on the stern, permanently, not less than 4 inches in height.
Vessel name and hailing port on the stern were less than 4 inches and not permanently marked, correct at next drydock.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 4 July 2024 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 28 June 2023
Resolved
Each Class 1 door on a vessel in ocean service must be watertight. Engine room watertight door is misaligned.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2023
Resolution: Eng Rm WTD realigned and adjusted.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 June 2023
Resolved
Fuel tank vent pipes must be fitted with flame screens. Port fuel tank vent on main deck has holes in the flame screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 30 June 2023
Resolution: Flame screen replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 June 2023
Resolved
Vessel name and hailing port as identified on the certificate of documentation must be marked on the bow and stern. Vsl name is incorrect (missing "M/V") and hailing port on stern is missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2023
Resolved 30 June 2023
Resolution: Markings properly applied to the vsl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 June 2021
Resolved
In no case shall the upper range of the gauge be less than 1.2 time nor more than 2 times the pressure at which the relieving device is set to function. The installed gauge had a maximum of 200 psi when the upper range of the gauge had to be between 210-350 psi.
46 CFR 54.15-5
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: Installed new gauges on the spot with a maximum range up to 300 psi.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 June 2021
Resolved
Each ring buoy must be marked in clearly legible block capital letters w/ the vessel's name & w/ Type I retro-reflective material. The name of the vessel was stenciled over the retro-reflective tape.
46 CFR 185.604(b) & (g)
Action required: 10 - Deficiency Rectified
Resolved 22 June 2021
Resolution: Stenciled vessel name and installed new retro-reflective tape.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 May 2019
Resolved
Replace gaskets and adjust main deck to utility room and utility room to engine room watertight door.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 1 May 2019
Resolved
Place vessel name on the vessel and change necessary documents to have correct vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2019
Resolved 2 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2019
Resolved
Replace or repair squirrel cage on fuel transfer pump motor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 May 2019
Resolved
Provide and install protective guard for fire monitor engine alternator belt.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2019
Resolved
Replace fuel return hose on stbd main engine and fuel supply hose on fire monitor engine that meet SAE J-1942.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 2 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2019
Resolved
Replace relief valve on engine room hot water heater.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 May 2019
Resolved
Relocate emergency light in utility room to illuminate egress to the main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 2 May 2019
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 May 2019
Resolved
Make adjustments to rescue platform to retrieve a helpless person from the water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2019
Resolved 2 May 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2019
Resolved
Provide and install blank in engine room electrical panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2019
Engineering › Generator (propulsion-electric) › Winding
Issued 17 January 2017
Resolved
Windings on starboard generator were covered in excess dust and oil. Provide proof of satisfactorily cleaning generator windings IAW 46 CFR 183.200(b).
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 19 January 2017
Resolution: Windings were cleaned.
Engineering › Bilge Water Management System › Strainer
Issued 17 January 2017
Resolved
Bilge suction in fwd portion of engine room has no strainer, has unathorized wire mesh. Replace mesh and provide proof of satisfactory installation of suitable strainer IAW 46 CFR 182.510(b).
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 19 January 2017
Resolution: Suitable strainer was installed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 10 May 2016
Resolved
Vessel bilge was full of oily water mixture about 8 inches deep the top 1/2" was an oil mixture, presented hazard to operations via exposed combustible liquid and possible free surface effect considerations. required vessel rep to pump down the bilge
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 11 May 2016
Resolution: cleared via receipt for cleaning from OSRO
Communications › Radio Communications › EPIRB
Issued 10 May 2016
Resolved
EPIRB registration did not have correct call sign, required vessel rep to provide registration with correct call sign within 30 days.
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 12 May 2016
Resolution: cleared via scanned copy of new EPIRB registration
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2016
Resolved
Identified 4 dead end wires under the console. Required VSL rep to remove the dead end wires.
Due 10 May 2016
Resolved 10 May 2016
Resolution: vessel rep removed the dead ends prior to departure of the CGMI.
Pollution Prevention/Response › Response Equipment › Emulsifiers
Issued 10 May 2016
Resolved
Spill kit missing emulsifiers, and non sparking scoop and shovel. Vsl rep provided replacement scoop. left work list item to provide emulsifiers. within 7 days
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 11 May 2016
Resolution: Cleared via receipt for emulsifier/cleaner for spill kit