Records from 1999 to 2026. Most recent: inspection, 22 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
22 May 2026
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8378442
2 May 2025
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8130333
19 April 2024
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7899411
26 May 2023
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7725462
28 April 2022
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7440047
28 July 2021
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7258025
1 July 2020
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6993202
17 April 2019
COC-CVE Annual · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6664713
18 April 2018
Administrative Inspection · Deficiency Check · COC-CVE Annual
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6394256
17 April 2017
COC-CVE Annual · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6126467
12 April 2016
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5921335
15 May 2012
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4306527
21 April 2009
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3636990
22 April 2008
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3199134
9 May 2007
Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2959573
17 April 2007
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2909624
18 April 2006
COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2626370
26 July 2005
Deficiency Check · COC-CVE Annual
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2426309
20 July 2004
COC-CVE Annual
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2139014
29 July 2003
Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1860262
8 August 2002
Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1658303
13 August 2001
Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1069004
10 August 2000
Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1432370
20 August 1999
Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1386594
Construction/Loadline › Structures › Superstructure
Issued 17 April 2007
Resolved
V/W cracked welds (02) at attachments of bench seats to side wall.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory repairs
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 17 April 2007
Resolved
- Fill holes in deck where component connections pass from engine space. Engine room should be well sealed to prevent the release of extinguishing agent.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory covering of penetrations to engine room.
Engineering › Bilge Water Management System › Not Operational
Issued 17 April 2007
Resolved
- Prove proper operation of starboard bilge pump float switch.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 17 April 2007
Resolution: Corrected prior to our departure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 April 2007
Resolved
- Correct chaffing interference of hydraulic lines at shift actuator on center drive unit.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 17 April 2007
Resolution: Lines repositioned prior to our departure with satisfactory demonstration of operation.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 April 2007
Resolved
- Replace retro reflective material on ring buoys.
Action required: 705 - Other - as specified
Due 17 April 2007
Resolved 9 May 2007
Resolution: Witnessed satisfactory renew of retro.
Engineering › Bilge Water Management System › Not Operational
Issued 26 July 2005
Resolved
Replace and properly mount high water alarm in engine space. (Identified wires not properly secured and switch installed with one screw vice two).
Action required: 705 - Other - as specified
Due 26 July 2005
Resolved 27 July 2005
Resolution: Attended vessel and witnessed satisfactory operation of installed system.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 July 2005
Resolved
Repair crack in way of starboard aft corner and forward port corner of passenger seating area top surface. (Understanding the properties of aluminum, it is suggested that the area, upon identification be marked and repaired prior to propagation).
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email from operation manager attesting to the satisfactory completion of issued requirements.
Fire Fighting › Ventilation Systems › Ducts
Issued 26 July 2005
Resolved
. Fire damper required to seal compartment when closed by means of adequate pressure not allow free passage of extinguishing agent from engine space. (Recommended that mating surface be free from obstruction (bolts), attach gasket to surface and closing spring implemented. Also, compartment protected by fire extinguishing agent should be free of excessive penetration such as old bolt holes an
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 10 September 2005
Resolution: Received email confirmation from operation manage attesting to the satisfactory correction of issued requirment.
Electrical › Electric Supply System (service) › Cable
Issued 26 July 2005
Resolved
Sensor for hydraulic block on Hamilton drive removed on two of three drives. Ensure manufacture approves of this modification, with report to Transport Canada and follow-up approval to the reported installation of gasket and inoperative switch.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 7 October 2005
Resolution: Received report form Transport Canada attesting to their examination of vessels and satisfactory completion of issued discrepancies.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 26 July 2005
Resolved
Provide report from Transport Canada regarding the serviceability of vessel.
Action required: 705 - Other - as specified
Due 5 August 2005
Resolved 7 October 2005
Resolution: Received report form Transport Canada attesting to their examination of vessels and satisfactory completion of issued discrepancies.