Records from 1981 to 2003. Most recent: inspection, 21 November 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 33
21 November 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1952068
9 October 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1687367
22 August 2002
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664397
2 November 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436636
27 February 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 766302
24 February 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 198568
18 October 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1450535
25 October 1999
COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1462785
10 December 1998
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1406399
22 October 1997
Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1465342
16 October 1996
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1363816
16 October 1995
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421027
5 July 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455171
31 May 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1411013
8 June 1993
COI Inspection · Drydock Extension
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 834078
10 June 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473161
26 November 1991
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939070
6 June 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238862
8 June 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230626
28 July 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203678
21 December 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350161
9 August 1988
Drydock Extension · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037560
6 June 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 438718
28 August 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003881
3 February 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015432
28 August 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338788
28 August 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300036
5 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286328
22 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280436
15 September 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279006
23 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966655
18 February 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1274751
13 October 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281595
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 August 2002
Resolved
Installed RPM gauges not working properly. LEGACY COMPONENT DESC: Gauges
Due 23 September 2002
Resolved 23 August 2002
Stability › Watertight Integrity
Issued 22 August 2002
Resolved
Watertight doors to engine room and aft superstructure not adjusted properly. LEGACY COMPONENT DESC: Doors
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 August 2002
Resolved
Cover and breaker blanks not secure and door will not close properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 August 2002
Engineering
Issued 18 October 2000
Resolved
REPAIR/REPLACE 1/2 IN SUCTION FUEL LINE ON PORT GENERATOR IN WAY OF DECK AND NOTCH OUT DECK PLATE IN WAY OF.
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Lifesaving
Issued 18 October 2000
Resolved
LABEL "EMERGENCY EXIT KEEP CLEAR" AT ENGINEROOM ESCAPE TOP/BOTTOM.
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Navigation
Issued 18 October 2000
Resolved
REPAIR STEERING HYDRAULIC LEAK IN WAY OF FORWARD CENTERLINE OVERHEAD IN AUXILLARY MACHINERY SPACE AT NEXT SHIPYARD OR SOONER IF NECESSARY.
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Lifesaving
Issued 18 October 2000
Resolved
PROVE PROPER OPERATION/PROVIDE RESCUE PLATFORM IAW 46 CFR 180.210, SAFETY HARNESS, SAFETY LINE AND STOKESLITTER.
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Electrical
Issued 18 October 2000
Resolved
HARD WIRE ELECTRICAL CORD OR INSTALL NEW WIRE & PLUG TO FREEZER IN AUXILLARY MACHINERY SPACE.
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Lifesaving
Issued 25 October 1999
Resolved
CONDUCT ABANDON SHIP AND MAN OVERBOARD DRILL'S AS INDICATED IN 46 CFR 185.520 AND FIRE DRILL AS INDICATED IN 46 CFR 185.524 IN THE PRESENT OF ATTENDING MARINE INSPECTOR I.A.W. 46 CFR 176.404.
Condition: Unknown
Due 18 November 1999
Resolved 18 November 1999
Electrical
Issued 22 October 1997
Resolved
INSTALL REMOTE SHUT DOWN FOR MAIN ENGINES AT CONTROL STATION.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Electrical
Issued 22 October 1997
Resolved
PROVIDE TWO PORTABLE BATTERY LIGHTS AND INSTALL IAW 46CFR183.430.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Engineering
Issued 22 October 1997
Resolved
RENEW FUEL OIL PACKING FOR PORT GENERATOR.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Lifesaving
Issued 22 October 1997
Resolved
PROVIDE TRAINING LOG TO MEET REQUIRED DRILLS.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Electrical
Issued 22 October 1997
Resolved
RENEW BATTERY CABLE FOR STBD GENERATOR.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Accommodation/Occupational Safety
Issued 22 October 1997
Resolved
STENCIL GALLEY EMERGENCY EXIT FOR CREW ACCOMADATION.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Lifesaving
Issued 22 October 1997
Resolved
PROVIDE EPIRB TEST LOG.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Navigation
Issued 22 October 1997
Resolved
INSPECT/RENEW PORT AND STBD RUDDER BEARINGS.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Construction/Loadline
Issued 22 October 1997
Resolved
REWELD/REPAIR STBD STERN TOP RUB RAIL. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Construction/Loadline
Issued 22 October 1997
Resolved
CLEAN/RENEW BILGE STRAINER IN AFT FWD PEAK.
Condition: Unknown
Due 6 November 1997
Resolved 6 November 1997
Lifesaving
Issued 16 October 1996
Resolved
Install reflective tape on vessels lifering.
Condition: Unknown
Due 16 October 1996
Resolved 18 October 1996
Engineering
Issued 16 October 1996
Resolved
Replace jacket water hoses from engine block to exhaust manifold on both main engines.
Condition: Unknown
Due 16 October 1996
Resolved 18 October 1996
Fire Fighting
Issued 16 October 1996
Resolved
Replace or adjust firepump packing and demonstrate proper operation.
Condition: Unknown
Due 16 October 1996
Resolved 18 October 1996