Records from 1980 to 2020. Most recent: inspection, 8 December 2020.
Documentation record
Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUXS BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portALAMEDA, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
8 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108317
19 July 2018
Administrative Inspection · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6482119
22 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6152133
18 April 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6127299
14 July 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5940525
27 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4214407
7 February 2011
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3940913
3 December 2010
Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3904998
18 February 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3681176
25 March 2009
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3439761
9 February 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3414840
16 October 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3080912
10 July 2007
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2991771
11 October 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2798583
20 January 2006
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2569893
22 July 2005
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2435425
29 September 2004
Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2210989
27 August 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2178404
7 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1922881
29 September 2003
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1916244
10 December 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1716861
10 October 2001
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1460579
29 May 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307023
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 July 2018
Resolved
Large crack/separation in rudder room on frame that connected the rudder posts
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2018
Resolution: Witnessed satisfactory weld at Dulac Ship Yard, Houma, LA
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 February 2010
Resolved
MDE's have 6 inch gap in lagging. SSDG missing all lagging within steering compartment. Provide proper lagging on both MDE's and generator.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 22 February 2010
Resolution: Witnessed installation of proper lagging on MDE and SSDG exhaust piping.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 February 2010
Resolved
One lifjacket deemed unsafe and taken out of service. Replace unservicable PFD with serviciable one.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 22 February 2010
Resolution: Vsl supplied with proper number of PFD''s
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 February 2009
Resolved
Provide 01 new lifejacket, old kapok style jacket failed examination.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2009
Resolved 10 February 2009
Resolution: Received copy of receipt via fax, proof of purchase for proper lifejacket.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 20 January 2006
Resolved
Provide required day shapes and not under command lights.
Condition: Improper Installation
Due 19 February 2006
Resolved 12 October 2006
Resolution: not required on vsl less than 65''
Lifesaving › Lifefloat › Markings
Issued 20 January 2006
Resolved
Mark underside of lifefloat as required.
Condition: Unknown
Due 12 October 2006
Resolved 12 October 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 20 January 2006
Resolved
Provide valve for a/c overboard spool piece. (rep could not determine if within 6 inches of deepest load condition--insector noted valve in spool piece on opposite side of vsl in same location)
Condition: Unknown
Due 12 October 2006
Resolved 12 October 2006
Resolution: ovbd 2'' above waterline.
Stability › Watertight Integrity › General
Issued 20 January 2006
Resolved
Provide captive chains for hatches.
Condition: Unknown
Due 12 October 2006
Resolved 12 October 2006
Lifesaving › Lifebuoys › Stowage
Issued 20 January 2006
Resolved
Secure lifebuoy bracket.
Condition: Improper/Lack of Maintenance
Due 12 October 2006
Resolved 12 October 2006
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 27 August 2004
Resolved
Condition: Improper/Lack of Maintenance
Due 27 September 2004
Resolved 23 April 2006
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 7 October 2003
Resolved
There was no flame screen on the port side gooseneck fuel vent.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2003
Resolution: 30 x 30 flame screen installed.
Lifesaving › Buoyant Apparatus
Issued 7 October 2003
Resolved
The water light on the life float did not function. LEGACY COMPONENT DESC: Water light
Action required: 705 - Other - as specified
Resolved 8 October 2003
Resolution: Provided new waterlight.
Lifesaving › Buoyant Apparatus
Issued 7 October 2003
Resolved
Only one paddle was provided for the life float, and that one was not tied down. LEGACY COMPONENT DESC: Paddle
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2003
Resolution: One new paddle was provided and both paddles were properly lashed down.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 October 2003
Resolved
Aft light in engine room did not function.
Action required: 705 - Other - as specified
Resolved 8 October 2003
Resolution: Made repair to light.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 October 2003
Resolved
Several hoses which were under pressure were only single clamped. LEGACY COMPONENT DESC: Hose clamps
Action required: 705 - Other - as specified
Resolved 8 October 2003
Resolution: Double clamps were provided as discussed.