PRISCILLA ANN is a 1979 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 1980, most recently in December 2020, along with 15 deficiencies.

Records from 1980 to 2020. Most recent: inspection, 8 December 2020.

Built
1979
Last inspected
8 December 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF9715
Flag
UNITED STATES
366827020, 367508070 (licence lapsed)
Maury page id
psix-50463

Inspections, by type

…with no type recorded2
Years with a record 15 calendar years (1980–2020)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUXS BAY-CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1979
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portALAMEDA, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF9715MMSI 367508070 · expired · compulsorily equipped · granted 27 October 2011, cancelled 1 January 2022
WDA6037MMSI 366827020 · cancelled · compulsorily equipped · granted 29 September 2001, cancelled 18 January 2011
WQZ5220MMSI not assigned · expired · voluntarily equipped · granted 26 October 1994, cancelled 13 November 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108317
19 July 2018 Administrative Inspection · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6482119
22 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6152133
18 April 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6127299
14 July 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5940525
27 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4214407
7 February 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3940913
3 December 2010 Type not recorded
No type recorded · USCGC PELICAN (WPB 87327) · USCG Heartland District (CGD-H) · Activity 3904998
18 February 2010 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3681176
25 March 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3439761
9 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3414840
16 October 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3080912
10 July 2007 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2991771
11 October 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2798583
20 January 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2569893
22 July 2005 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2435425
29 September 2004 Simplified Stability Test
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2210989
27 August 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2178404
7 October 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1922881
29 September 2003 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1916244
10 December 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1716861
10 October 2001 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1460579
29 May 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307023

Deficiency record · 15

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 July 2018 Resolved
Large crack/separation in rudder room on frame that connected the rudder posts
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 July 2018
Resolution: Witnessed satisfactory weld at Dulac Ship Yard, Houma, LA
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 February 2010 Resolved
MDE's have 6 inch gap in lagging. SSDG missing all lagging within steering compartment. Provide proper lagging on both MDE's and generator.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 22 February 2010
Resolution: Witnessed installation of proper lagging on MDE and SSDG exhaust piping.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 February 2010 Resolved
One lifjacket deemed unsafe and taken out of service. Replace unservicable PFD with serviciable one.
Action required: 705 - Other - as specified
Due 22 February 2010
Resolved 22 February 2010
Resolution: Vsl supplied with proper number of PFD''s
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 February 2009 Resolved
Provide 01 new lifejacket, old kapok style jacket failed examination.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 February 2009
Resolved 10 February 2009
Resolution: Received copy of receipt via fax, proof of purchase for proper lifejacket.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 20 January 2006 Resolved
Provide required day shapes and not under command lights.
Condition: Improper Installation
Due 19 February 2006
Resolved 12 October 2006
Resolution: not required on vsl less than 65''
Lifesaving › Lifefloat › Markings
Issued 20 January 2006 Resolved
Mark underside of lifefloat as required.
Condition: Unknown
Due 12 October 2006
Resolved 12 October 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 20 January 2006 Resolved
Provide valve for a/c overboard spool piece. (rep could not determine if within 6 inches of deepest load condition--insector noted valve in spool piece on opposite side of vsl in same location)
Condition: Unknown
Due 12 October 2006
Resolved 12 October 2006
Resolution: ovbd 2'' above waterline.
Stability › Watertight Integrity › General
Issued 20 January 2006 Resolved
Provide captive chains for hatches.
Condition: Unknown
Due 12 October 2006
Resolved 12 October 2006
Lifesaving › Lifebuoys › Stowage
Issued 20 January 2006 Resolved
Secure lifebuoy bracket.
Condition: Improper/Lack of Maintenance
Due 12 October 2006
Resolved 12 October 2006
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 27 August 2004 Resolved
Condition: Improper/Lack of Maintenance
Due 27 September 2004
Resolved 23 April 2006
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 7 October 2003 Resolved
There was no flame screen on the port side gooseneck fuel vent.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2003
Resolution: 30 x 30 flame screen installed.
Lifesaving › Buoyant Apparatus
Issued 7 October 2003 Resolved
The water light on the life float did not function. LEGACY COMPONENT DESC: Water light
Action required: 705 - Other - as specified
Resolved 8 October 2003
Resolution: Provided new waterlight.
Lifesaving › Buoyant Apparatus
Issued 7 October 2003 Resolved
Only one paddle was provided for the life float, and that one was not tied down. LEGACY COMPONENT DESC: Paddle
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2003
Resolution: One new paddle was provided and both paddles were properly lashed down.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 October 2003 Resolved
Aft light in engine room did not function.
Action required: 705 - Other - as specified
Resolved 8 October 2003
Resolution: Made repair to light.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 7 October 2003 Resolved
Several hoses which were under pressure were only single clamped. LEGACY COMPONENT DESC: Hose clamps
Action required: 705 - Other - as specified
Resolved 8 October 2003
Resolution: Double clamps were provided as discussed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.