← All vessels
STARSHIP
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named STARSHIP
STARSHIP is a 1999 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1999, most recently in March 2026, along with 255 deficiencies, 2 operational controls and 7 casualty investigations between 2006 and 2019.
Records from 1999 to 2026. Most recent: inspection, 9 March 2026.
- Built
- 1999
- Last inspected
- 9 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 255 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 7 investigations · 2006–2019
Identity
1087635
WDF8292
504648
Flag
UNITED STATES
367493350
Maury page id
psix-504648
Inspections, by type
…with no type recorded18
Years with a record
24 calendar years (1999–2026)
The 91 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)147.7 ft × 42.0 ft × 7.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)147.7 ft × 42.0 ft × 7.0 ft
ITC tonnagegross 1,127 / net 365
BuilderFREEPORT SHIPBLDG HULL #261 INC · FREEPORT, FL, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
1127 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
365 - Convention (Subpart B), Net Ton
1127 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
365 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF8292MMSI 367493350 · active · compulsorily equipped · granted 30 March 2021, expires 4 June 2031
WCZ5806MMSI not assigned · expired · voluntarily equipped · granted 8 December 1999, cancelled 13 February 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 91
9 March 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8323240
12 January 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8295323
16 December 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8284147
15 September 2025
Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8235105
28 May 2025
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8148401
31 March 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8102936
5 August 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7975225
28 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7891557
17 August 2023
In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7770440
1 August 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7757895
23 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7662363
8 August 2022
Hull Examination · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7528287
29 July 2022
Load Line/Change of Employment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7511989
7 July 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7499711
18 April 2022
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7405954
21 October 2021
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7330776
3 May 2021
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7172951
21 August 2020
Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7026016
15 June 2020
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6965408
30 October 2019
Administrative Inspection · Security Breach, Potential
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6845717
23 September 2019
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6819050
16 June 2019
Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6716466
16 June 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6724293
10 June 2019
Annual Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6664440
18 September 2018
Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6533342
31 July 2018
Annual Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6482655
29 June 2018
Deficiency Check · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6459534
1 August 2017
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6215099
13 September 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995449
30 August 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6009783
23 August 2016
Administrative Inspection · Excursion Permit
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5980902
26 June 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5919444
26 June 2016
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5933788
26 June 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5937916
29 April 2016
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5865350
10 January 2011
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3922700
11 February 2010
Internal Structural Exam · Drydock Extension · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3687122
20 February 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3422213
5 February 2009
Administrative Inspection · DAPI Audit
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3412807
3 November 2008
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3356246
28 May 2008
Re-Inspection · Deficiency Check · MTSA Verification · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3220958
7 January 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3126284
28 November 2007
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3105964
19 November 2007
MTSA Verification · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3100837
27 May 2007
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2944738
20 April 2007
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2911802
20 April 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2926958
9 March 2007
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3175127
3 March 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2881774
27 February 2007
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2878924
25 February 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2882562
12 February 2007
MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2870641
22 September 2006
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2789305
31 August 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2779245
11 April 2006
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2622474
28 February 2006
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2593086
28 November 2005
Excursion Permit
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2541651
3 August 2005
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2449887
30 March 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2323165
29 March 2005
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2322077
8 March 2005
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2321943
24 February 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2298310
10 January 2005
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2271905
25 October 2004
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2227633
21 October 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2294560
23 August 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2248229
29 June 2004
Deficiency Check · MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2114653
3 June 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2087616
24 April 2004
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2051602
5 February 2004
Plan Review "T" Boat · In-Service Inspection · Deadweight Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2001258
29 January 2004
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1996511
15 January 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2209792
7 January 2004
Hull Examination · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1684360
2 December 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1929763
13 August 2003
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1874936
15 July 2003
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1847147
19 December 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1720756
27 November 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1706072
21 December 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1474490
24 October 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1412390
24 September 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1462992
17 September 2001
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1073328
3 April 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060243
3 April 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1069716
26 January 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469338
2 January 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1062883
21 April 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 183444
29 March 2000
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 105410
3 February 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1047151
30 November 1999
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1465522
24 November 1999
Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 809607
Deficiency record · 255
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 December 2025
Resolved
46 CFR 120.310(a)
Each vessel that relies on electricity to power the vital systems must be arranged so that the loads can be energized from two sources of electricity. O/O notified office that they identified an issue with port generator while conducting routine maintenance. Generator is not operational.
CODE 705: Vessel must operate within the parameters of the approved waiver to continue commercial operations with one generator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 May 2024
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks.
MI observed exhaust leaks on both main diesel engines and the bow thruster engine while operating.
46 CFR 119.430(b)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2024
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operations.
MI observed emergency fuel shutoff labeling was missing direction of operations.
46 CFR 122.608
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 May 2024
Resolved
The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed.
MI observed loose dogs on the engine room emergency escape hatch and a loose handle on the engine room door.
46 CFR 116.500(i)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
MI observed three electrical wires hanging from the ceiling in the lazarette compartment.
46 CFR 120.200(b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2024
Resolved
The Vessel Security Officer must, for each vessel for which he or she has been designated: ensure security equipment is properly operated, tested, calibrated and maintained.
MI observed vessel did not have maintenance records for security screening wand on board past 2022.
Vessel must conduct maintenance in accordance with manufacturers' instructions.
33 CFR 104.215(e)(10)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 May 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
MI observed two adult life jackets were unserviceable.
Vessel's adult life jackets total is 722.
46 CFR 117.71(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2024
Resolved
Minimize accidental personnel contact with energized parts.
MI observed a missing switch in a breaker panel on vessel's second deck and had not been blanked off.
46 CFR 120.200(c)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 May 2023
Resolved
A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead.
MI observed that the sliding fire door separating the galley from the accommodation space door frame was not secured to the bulkhead properly allowing the door frame to protrude off the bulkhead.
Vessel will repair/restore the fire boundary prior to the carriage of passengers.
46 CFR 116.435(C)(1)
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 May 2023
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. Unless specifically permitted in 400.7, flexible cords and cables shall not be used for as a substitute for the fixed wiring of a structure.
MI found non-portable fans on upper deck found to be powered by temporary cables.
46 CFR 120.340(r)
46 CFR 111.60-13(b)(1)
NFPA NEC 2002 400.8(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2023
Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150.
MI observed the port aft main deck life buoy to not have the identification tag with an approval number.
46 CFR 117.70(b)(1)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2023
Resolved
Each hose must: Be lined commercial fire hose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies” (incorporated by reference, see § 114.600 of this chapter), or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance.
MI observed a hole in the fire hose at the fitting connected to the hydrant. Vessel has procured new hose.
46 CFR 118.320(b)(1)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2022
Resolved
Each fire hose must be lined commercial firehose that conforms to UL 19.
MI found firehose for Fire Station #3 leaking at connection to hydrant.
46 CFR 118.320(b)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 April 2022
Resolved
Each life jacket must be marked with Type 1 retro-reflective material.
MI found 03 life jackets requiring new retro-reflective material.
46 CFR 122.604(h)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2022
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. Unless specifically permitted in 400.7, flexible cords and cables shall not be used for as a substitute for the fixed wiring of a structure.
MI found non-portable fans on upper deck found to be powered by temporary cables.
Provide repair proposal.
46 CFR 120.340(r)
46 CFR 111.60-13(b)(1)
NFPA NEC 2002 400.8(1)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 May 2021
Resolved
In fire detection and alarm systems with addressable detectors and manual pull stations, every fault must be monitored and must not prevent the continued individual identification of the remaining detectors.
After testing the smoke detector on the bridge, no other smoke detector would activate throughout the ship. Prove full operational capability of fire detection system prior to carrying passengers.
46 CFR 76.27.10(e)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 May 2021
Resolved
The A-60 fire boundary from bow thruster to main galley room/ball room was missing insulation in multipile areas and would not prevent passage of smoke/flame for specified time.
46 CFR 116.415
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021
Resolved
The fuel lines to the starboard MDE fuel pressure gauge and the port MDE oil pressure gauge are cotton sleeved and pose a fire hazard.
46 CFR 119.455
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2020
Resolved
The following spaces must be equipped with a fire detection and alarm system, except that when a fixed gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed: (1) A space containing propulsion machinery.
The heat detection probe in the bow thruster room was painted over, changing the heat detection properties of the sensor. 46 CFR 118.520
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited.
Terminal connections to port battery in bow thruster compartment secured via wing nuts.
46 CFR 120.350
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway.
Junction box in fuel tank compartment was not securely
mounted.
46 CFR 120.2020 (a)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020
Resolved
All electrical equipment and circuits must be clearly marked and identified.
Distribution panels in the following locations were missing or had inaccurate circuit directories:
-Third Deck Bar
-Galley
-Wine Room
-Port Side Second Deck for "Starboard Nav. Lights"
-Dry-stores(2x)
46 CFR 120.220 (d)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 June 2020
Resolved
A shutoff valve must be located where the cooler piping penetrates the shell, as near the shell as practicable, except where the penetration is forward of the collision bulkhead.
Starboard keel cooler shut off valve in lazarette was missing handle.
46 CFR 119.422 (b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2019
Resolved
The engine head, block, and exhaust manifold must be water jacketed and cooled by water from a pump that operates whenever the engine is operating. Prior to getting underway or operating generators, provide technician report attesting to the proper repair and operation of the port generator prime mover. 46CFR119.420(a)(1)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2019
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the cognizant [name withheld] side engine room fire extinguisher at ladder well mounted using a hook and a hose clamp. Mount extinguisher in accordance with manufacturer's recommendation. 46 CFR 118.520
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2019
Resolved
The following spaces must be equipped with a fire detection and alarm system, except that when a fixed gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed: (1) A space containing propulsion machinery. The heat detection probe in the port side engine room was painted over, changing the heat detection properties of the sensor. Clean to original. 46 CFR 118(c)(1)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 June 2019
Resolved
Each Class 1 door must have a quick action closing device operative from both sides of the door. The watertight door at the entrance to the engine room did not close completely with the closing device. Repair.46 CFR 116.100(b)46 CFR 170.270(a)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 June 2019
Resolved
If installed, a hold back mechanism for a door must allow the door to be released. The 2nd Deck galley sliding fire screen door did not close properly when released from the bridge control station. Repair as original. 46 CFR 116.435(c)(6)(i)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 June 2019
Resolved
A door in a bulkhead required to be a A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead. Fire doors leading from the main deck galley out to the whether deck and to the storage room were missing gasket material. Replace as original. 46 CFR 116.435(c)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2019
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Forward mast light was inoperable. Repair or replace. 46 CFR 120.420
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop/renew 2 sections on port side of bow in forepeak prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop/renew section along stbd side shell, bulkhead ivo port damper side shell, and damper frame in bos thruster compartment prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop/renew bottom plate ivo keel in fuel void prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop and renew bulkhead along 2 bays in lazarette prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop/renew stbd hull forward of exhaust discharge prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop/renew 2nd deck galley prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Repair 03 welds on stbd hull prior to credit drydock iaw 46CFR115.600 (a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Clean and gauge port and stbd exhaust dischage ports prior to credit DD iaw 46CFR155.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Repair/replace forepeak hatch prior to credit DD iaw 46CFR115.600(a).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2018
Resolved
At each initial and subsequent inspection for certification of a vessel the owner shall have the vessel ready for inspections of machinery.
Repair/replace leaking capstan motor iaw 46CFR115.804
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop/renew center frame in forepeak prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Remove contents in fore peak and guage bow ivo center line iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Crop/renew wasted fire damper ivo bow thruster room prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Clean and gauge deck in bow thruster room ivo bilge suction area prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
In fuel compartment gauge forward stbd side and area ivo bilge suction prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Clean and gauge under port chiller in engine room prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Clean and gauge under port shaft prior to credit DD iaw 46CFR115.600(a).
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018
Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations.
Gauge second deck galley prior to credit DD iaw 46CFR115.600(a).
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 September 2018
Resolved
In the application of inspection standards due consideration must be given to the hazards involved in the operation permitted by the vessel's COI.
Replace bilge suction strainer in potable water void and in fuel compartment prior to credit DD iaw 46CFR115.600(a).
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2018
Resolved
If a cylinder is discharged and more than 5 years have elapsed since the last test, it must be retested before recharging. MI observed accidental discharge of fixed CO2 system in bow thruster room. Vessel Rep must hydro cylinders, flex tubes, provide tech report. MI present for tech testing. 46CFR147.65(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 31 July 2018
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. MI observed crew members lacking proper training on fire extinguishing systems on board.46CFR122.524(a)
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 31 July 2018
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew
members are familiar with their duties during
emergencies that necessitate abandoning ship or the
recovery of persons who have fallen overboard.46CFR122.520(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2018
Resolved
A vessel must have a sufficient number of fire hydrants
to reach any part of the vessel using a single length of
fire hose. MI observed #5 fire station inaccessible.
46CFR118.310(a)
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 July 2018
Resolved
A door must have a latch with a minimum throw of 20 millimeters. MI observed stbd side second deck fire door did not latch.
46CFR114.400(b)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 July 2018
Resolved
High risk service spaces (9) include galley; large laundry or drying room; garbage or trash disposal storage area; paint or lamp locker; cleaning gear locker or small storeroom in an accommodation area; mail or baggage room; and pantries and storerooms which contain flammable liquids or have a deck area not less than 5 square meters including connecting alleyways and stairs.
MI observed furniture in galley space designated as a high risk service space being used improperly as a storage locker.
46CFR116.435(c)(3)
02 - Structural Conditions › N/A - No Subsystem › Information on the A/A-max Ratio (Roro/pass. only)
Issued 31 July 2018
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed stbd side exhaust fan in engine room covered in oil and cluttered.
46CFR120.200(b)
11 - Life Saving Appliances › N/A - No Subsystem › Anti-exposure suits
Issued 31 July 2018
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MI observed 01 life buoy in need of replacement.
46CFR117.70(a)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2018
Resolved
At least one ring buoy must be fitted with a floating waterlight, unless the vessel is limited to daytime operation, in that case no floating waterlight is required. MI observed that waterlight is inoperable.
46CFR117.70(d)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 31 July 2018
Resolved
If a vessel operates on exposed or partially protected waters, an opening port light is not permitted below the weather deck unless it has an inside, hinged dead cover.
MI observed wasted hatch leading to steering gear compartment. To be repaired during next DD.
46CFR171.119(a)(2)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 July 2018
Resolved
The emergency lighting required by paragraph (a) of this section must automatically actuate upon failure of the main lighting system. MI observed multiple emergency lights that were inoperable.
46CFR120.432(b)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 July 2018
Resolved
A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. MI observed hole/leak ivo main deck/engine room bulkhead; ivo bar and pipe with soda lines. To be repaired during next DD.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 July 2018
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Provide updated charts for area of operations. MI observed navigation charts are out of date.
46 CFR 121.420 (a)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2018
Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with mat black inboard screens and meet the requirements of 84.17. Navigation light screens are faded. Repaint light screens to a mat black.
Inland Navigation Rules Annex I 84.09
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2018
Resolved
Each ring life buoy on a vessel must: (3) Be stowed in a way that it can be rapidly cast loose: (4) Not be permanently secured in any way. Ring life buoy located on the port bridge wing was secured in place with banding strap. Vessel representative removed banding strap.
46 CFR 117.70(b)(3)(4)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 July 2018
Resolved
A weathertight door with permanent watertight coamings that comply with must be provided for each opening located in a deck house or companionway. Weathertight
door located on 2nd deck portside aft leading to promenade deck does not close. Repair/replace
46 CFR 171.124(d)
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 31 July 2018
Resolved
An internal structural examination conducted in compliance with 115.600 of this part may be conducted while the vessel is afloat. Found deck located on the 2nd deck with in the galley area needs to be gauge during next drydock and provided findings to local marine inspector.
46 CFR 115.610(b)
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 July 2018
Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] located on the portside in the steering compartment has two pinholes. Identify system piping is for and repair or replace piping.
46 CFR 119.700
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 July 2018
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations and underwater surveys required by this section. At vessels next drydock make available for inspection suspect areas identified in the steering gear compartment by the attending marine inspector.
46 CFR 115.600(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 June 2018
Resolved
Exhaust gas must not leak from the engine or any connection.
03 pinhole exhaust leaks discovered on generator. Replace muffler in-kind. - 46CFR119.430(b) - 16c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2018
Resolved
Exhaust gas must not leak from the piping or any connections.
Multiple exhaust leaks discovered on port generator. Remove generator lagging and inspect all piping to identify for any additional leaks. Repair all leaks or replace exhaust piping. Tighten exhaust flange identified on starboard main diesel engine. - 46CFR119.430(b) - 17c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 June 2018
Resolved
Except as otherwise provided in paragraph (b) of this section, all engines must be water cooled and meet the requirements of this paragraph. Engine salt water cooling line for bow thruster is leaking. Repair or replace. - 46CFR119.420(a) - 17c
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 29 June 2018
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be insulated where necessary to prevent injuries. Starboard main engine exhaust lagging is missing near the aft engine room bulkhead. Install lagging. - 46CFR116.970 - 16c
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 1 August 2017
Resolved
Remove all non-metallic trash barrels onboard IAW 46 CFR 116.405(i).
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 August 2017
Resolved
Repair latch on "wine room" fire door IAW 46 CFR 116.435.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 August 2017
Resolved
Replace SOLAS retro tape on 152 extended size and 35 childrens lifejackets IAW 46 CFR 117.71. Restricted to 0 children and 569 adults.
Fire Fighting › Combustible Materials › Facings/Mouldings/Decorations/Veneers
Issued 1 August 2017
Resolved
Remove combustibles from category 12 space on 3rd deck IAW 46 CFR 116.405(b).
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 August 2017
Resolved
Repair latches on galley fire doors IAW 46 CFR 116.435.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 June 2016
Resolved
Main generator breaker phase C is running at a higher temperature than usual. Make repairs to the main generator breaker panel to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 February 2010
Resolved
Reattach the metal clips for the winch motor in the bow void.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 February 2010
Resolved
Readjust fire screen doors main deck entrance area.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 11 February 2010
Resolved
Reseal and secure beverage line in deck penetration behind bar in Star 2 with UL rated (CG accepted) fire rated caulk.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 February 2010
Resolved
Provide operable door latch (3/4" throw) for main store room door.
Accommodation/Occupational Safety › Potable Water System › General
Issued 11 February 2010
Resolved
Fuel void - provide metallic pipe support bracket for sink drain.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 11 February 2010
Resolved
Provide annual service report for fixed fire systems and fire detection.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 February 2010
Resolved
Provide GA plan change for Star 2 wait station (bulkheads).
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 February 2010
Resolved
Make galley sliding fire door handles and emergency stop push bar operational and replace missing insulation on bulkheads above the door. Identify which side of the bulkhead is supposed to be insulated.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 February 2010
Resolved
Install electrical receptacle cover in main galley near the dumb waiter.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 11 February 2010
Resolved
Palm Court - install missing overhead insulation in stbd side closet near aft bulkhead and in the port side closet on the overhead near the aft bulkhead.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 February 2010
Resolved
Conduct credit drydock and internal structural examination meeting 46 CFR 115 Subpart F, and Coast Guard COI or Annual Inspection per 46 CFR 115 Subpart D or E, as determined by the cognizant OCMI prior to carrying more than 6 passengers for hire.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 November 2008
Resolved
Install double hose clamps on exhaust hoses in the steering compartment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 November 2008
Resolved
Hard wire water softener pump and carbon filter in steering compartment.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 November 2008
Resolved
Remove dead ended wires in overhead port side steering compartment.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 November 2008
Resolved
Install guard on the engine room exhaust fan.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 November 2008
Resolved
Remove dead end wires in overhead above the #1 generator.
Documentation › Markings/Placards › Warning Signs
Issued 3 November 2008
Resolved
Re-stencil remote fuel shutoff valve in way of Star Bar Two.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 November 2008
Resolved
Re-install lights where missing in way of rescue boat launching platform.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 3 November 2008
Resolved
Provide report for servicing of fixed fire fighting system for engine room and bow thruster.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 3 November 2008
Resolved
Provide checklist for lifesaving maintenance exams.
Operations/Management › Drills/Instruction › Fire
Issued 28 May 2008
Resolved
Conduct fire & boat drills prior to carriage of passengers
Lifesaving › Rescue Boat › Hull (rigid)
Issued 28 May 2008
Resolved
Make permanent repairs to crack along the keel.
Construction/Loadline › Penetrations › Bottom Plug
Issued 28 May 2008
Resolved
Repair or replace plug hole IWO main deck bar.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 May 2008
Resolved
remove all flammable liquids from galley.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 May 2008
Resolved
make permenet repairs to exhaust for stbd generator "V" band near turbo.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 May 2008
Resolved
Make repairs to water leak in exhaust system for stbd generator.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 28 May 2008
Resolved
repair lagging for the stbd generator.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 November 2007
Resolved
Properly secure or remove dead end wires and loose junction box in the fuel tank void.
Electrical › Electrical Distribution System (service) › Switch
Issued 19 November 2007
Resolved
Prove proper operation of the ventilation in the bow thruster room.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 November 2007
Resolved
Repair the anchor light.
Documentation › Certificates/Documents › FCC SSL
Issued 19 November 2007
Resolved
Provide proof of the Safety Radio Telephony Certificate.
Construction/Loadline › Structures › Door
Issued 19 November 2007
Resolved
Insure the proper threshold clearance IWO two 2nd deck fire boundry doors, (aft door to the galley and the forward door stbd side to the weather deck).
Engineering › Bilge Water Management System › Not Operational
Issued 19 November 2007
Resolved
Prove proper operation of the bilge system in all compartments served.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 November 2007
Resolved
Provide light covers as necessary for the fixtures in both galley's.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 19 November 2007
Resolved
Provide ceiling tiles where missing in the main deck galley.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 19 November 2007
Resolved
Provide two hose clamps for each hose connection in the lazarette.
Engineering › Freshwater Generation System › Heat Exchanger
Issued 19 November 2007
Resolved
Properly secure the water heater in the lazarette.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 27 May 2007
Resolved
Repair or replace the solenoid switch controling the forward propulsion control on th e port main engine.
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 20 April 2007
Resolved
Make permanent repairs to port generator prior to 24Apr07. Ensure engine room rounds are made every 30 minutes while stbd generator is running.
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 20 April 2007
Resolved
Change lube oil and filters on port generator as recommended by service representative from Florida Detroit Diesel and place generator in standby.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 February 2007
Resolved
Satisfactorily complete all 38 worklist items issued 12FEB07 as described in MISLE Activity #2870641.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 February 2007
Resolved
Repair 2nd deck port fwd door. (Door pulls open when closed/ does not properly secure)
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 February 2007
Resolved
Make general repairs to deteriorating exhaust cooling piping for the #2 main and #2 generator engines during next dry-dock.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 12 February 2007
Resolved
Port side exit door- repair latch with min 3/4" latch throw.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 28 February 2006
Resolved
Secure all galley equipment (table, burners, warmers).
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 February 2006
Resolved
Repair emergency light for engine room ladder.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 February 2006
Resolved
Swap emergency lights dry stores to engineroom vise versa as discussed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 28 February 2006
Resolved
Remove extra oil/gear/cardboard from engine room as discussed.
Electrical › Lighting (service) › Outlet Box
Issued 28 February 2006
Resolved
Provide switch cover for multi switches behind sage in star one.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 February 2006
Resolved
Demonstrate proper operation of masthead lights prior to operation after dark.
Operations/Management › Navigation Safety › Towing Tests/Inspections
Issued 28 February 2006
Resolved
Prior to carriage of passengers provide 6 orange smoke flares
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 February 2006
Resolved
Prior to operating greater than 1 mile from land replace EPIRB and hydrostatic release IAW 46 CFR 117.207(d).
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 28 February 2006
Resolved
To operation more than 1,000 feet from shore provide valid safety radio certificate.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 28 February 2006
Resolved
Repair/install door latches for bridal suite and third deck door as necessary conduct maintenance
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 February 2006
Resolved
Conduct six year maintenance on all portable dry chemical extinguishers as necessary conduct maintenance
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 28 February 2006
Resolved
Reinstall structural fire protection insulation as necessary.
Operations/Management › Drug and Alcohol Testing › CG Notification (positive results/refusals)
Issued 1 March 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Lighting (service) › Outlet Box
Issued 1 March 2005
Resolved
Repair/Replace/Ensure proper type electrical receptacle boxes for all main deck floor installations are provided. Boxes are loose or falling off of the overhead. 46 CFR 120.220.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 24 February 2005
Resolved
Provide general description of training as required by 46 CFR 122.420
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 February 2005
Resolved
Provide valid Certificate of Documentation per 46 CFR Part 67
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 24 February 2005
Resolved
Provide deviation table for magnetic compass 46 CFR 122.402
Communications › Radio Communications › VHF Radiotelephone
Issued 24 February 2005
Resolved
Provide specific vessel details required for Emergency Broadcast Placard per 46 CFR 121.506
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 February 2005
Resolved
Provide additional information required for a Fire Control Plan/EEP - Number of Persons in each area, detector symbols updated, and hazard classifications and SFP boundaries per 46 CFR 116.530. Provide update to cognizant OCMI.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 24 February 2005
Resolved
Provide written Emergency Evacuation Plan (EEP) procedures and information per 46 CFR 116.520. Provide copy to cognizant OCMI.
Operations/Management › Drills/Instruction › Fire
Issued 24 February 2005
Resolved
Identify a deckhand assigned specific deckhand duties for each deck (MSM Vol III, Ch 21, Local [name withheld]).
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 February 2005
Resolved
Provide detailed checklist for each piece of lifesaving and machinery equipment requiring maintenance to correspond with mfg guidelines or 46 CFR inspection requirement for each item.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 24 February 2005
Resolved
Provide current/updated copies of navigational publications per 46 CFR 121.420.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 February 2005
Resolved
Provide acceptable door latch system for door in fire boundary located port side 2nd deck galley to comply with 46 CFR 116.435.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 February 2005
Resolved
Provide copy of purchase request for door latch for 2nd deck galley door.
Fire Fighting › Structural - A Class Divisions › Pantries
Issued 24 February 2005
Resolved
Close all holes in A Class boundary blkhd in 2nd deck galley to meet boundary protection required by 46 CFR 116.415(a)(2).
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 February 2005
Resolved
Provide test medium recommended by fixed fire detection system mfg for testing all types detectors on vessel (46 CFR 115.810(a)(7) and mfg recommendation).
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 24 February 2005
Resolved
Demonstrate testing of fixed fire detection system in presence of CG Marine Inspector (46 CFR 115.810(a)(7).
Fire Fighting › Fire Pumps › Pressure
Issued 24 February 2005
Resolved
Repair/replace fire pump outlet pressure gauge.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 February 2005
Resolved
Clean excess grease from exhaust hood in new galley per 46 CFR 115.830.
Documentation › Markings/Placards › Warning Signs
Issued 24 February 2005
Resolved
Remove "Evacuate space when CO2 alarm sounds" sign on fwd blkhd in dry storage compt.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 24 February 2005
Resolved
Mount the fire extinguisher in the dry stores in a more suitable location, not on the fire hose rack. Provide marine approved portable fire ext bracket in galley dry stores compt specified by mfg label on the fire extinguisher per 46 CFR 118.500.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 24 February 2005
Resolved
Seal wire penetration through top of fwd blkhd in galley dry store space with approved fire stop material per 46 CFR 116.415(a)(2).
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 24 February 2005
Resolved
Seal holes in double fire screen door main deck fwd 46 CFR 116.415(a)(2).
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 February 2005
Resolved
Demonstrate proper operation/latching of double fire screen doors stbd side aft main deck main entrance area and 2nd deck stair tower port side per 46 CFR 116.435.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 24 February 2005
Resolved
Identify ongoing repairs aft end overhead Star 1 (fwd main deck dining) behind curtain and remove wood, reinstall SFP insulation and provide proper application of electrical wire nuts (46 CFR 120.340(g)&(h)).
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 24 February 2005
Resolved
Prove curtains meet 46 CFR 116.423(a)(3) (i.e. located on blkhd at aft end of Star 1 (main deck fwd dining), and aft Star 2 main deck, 2nd deck aft exterior).
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 24 February 2005
Resolved
Provide non-combustible waste receptacles meeting 46 CFR 116.405(i) or prove current receptacles meet non-combustible standard defined in 46 CFR Part 164.009.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 24 February 2005
Resolved
Remove combustibles stowed in closets in accommodations spaces (i.e. air handler filter cartons and cardboard).
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 February 2005
Resolved
Stencil the engine room emergency escape in the galley per 46 CFR 122.606
Electrical › Lighting (service) › Lighting Fixture
Issued 24 February 2005
Resolved
Provide two new light covers for the lights in the sewage void.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 24 February 2005
Resolved
Provide GFI electrical outlets in 2nd deck galley and in 1st aft bar per 46 CFR 120.200.
Electrical › Lighting (service) › Lighting Fixture
Issued 24 February 2005
Resolved
Provide wire support meeting 46 CFR 120.340(b) for overhead light fixture aft blkhd in male head on 2nd deck.
Fire Fighting › Ventilation Systems › Ducts
Issued 24 February 2005
Resolved
Stencil the fire damper remote closure for the engine room exhaust located on the stbd side in the main deck galley.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 24 February 2005
Resolved
Correct the following items on SFP plans approved June 14, 2004: Re-classify compartment hazard type for HAVC spaces and Coat Closets in all accommodation areas and provide required fire boundaries for each.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 24 February 2005
Resolved
Correct the following items on SFP plans approved June 14, 2004: Show bulkhead between bridal suite and office on 3rd deck port side forward.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 24 February 2005
Resolved
Correct the following items on SFP plans approved June 14, 2004 Re-classify compartment hazard type for gift shop, install a smoke detector (46 CFR 118.400(e)), and update fire control plan.
Fire Fighting › Combustible Materials › Ceilings
Issued 24 February 2005
Resolved
Remove wood from overhead of gift shop 46 CFR 116.405(b).
Fire Fighting › Combustible Materials › Ceilings
Issued 24 February 2005
Resolved
Verify/Prove that bulkhead & linings in gift shop meet 46 CFR 116.422.
Lifesaving › Rescue Boat › Markings
Issued 24 February 2005
Resolved
Replace the retro tape on the rescue boat.
Engineering › Pressure Vessel › Relief Valve
Issued 24 February 2005
Resolved
Replace the relief valves on both air receivers per 46 CFR 119.330.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 February 2005
Resolved
Provide MIS form, or Consortium letter stating report filed for employer (2004) 46 CFR 16.500.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 24 February 2005
Resolved
Provide information from consortium to determine number of positive tests for 2004 and establish method for tracking each year.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 24 February 2005
Resolved
Demonstrate use of drug testing background checks per 49 CFR 40.25
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 24 February 2005
Resolved
Demonstrate random tests being performed on individuals identified by consortium 46 CFR 16.230.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 24 February 2005
Resolved
Demonstrate required EAP information is provided and displayed as required by 46 CFR 16.401
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 February 2005
Resolved
Conduct required EAP training for crewmembers before they assume safety sensitive positions and provide documentation 46 CFR 16.401.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 24 February 2005
Resolved
Provide 1 hour EAP training for supervisors and demonstrate documentation of training 46 CFR 16.401.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 February 2005
Resolved
Provide copy of contract or proof of enrollment in consortium 46 CFR 16.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 February 2005
Resolved
Provide Consortium policy/instructions for managing chemical drug and alcohol testing program to include pre-employment, random, SMI, and reasonable cause testing guidance.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 February 2005
Resolved
Identify if consortium has Coast Guard Letter of Regulatory Compliance (LORC) and provide copy.
Engineering › Steering Gear System › Rudder
Issued 25 October 2004
Resolved
Starboard Rudder was reprted missing on 24 OCT 04 after a dive survey on 23 OCT04.
Engineering › Steering Gear System › Follow-up Assembly
Issued 15 January 2004
Resolved
Adjust rudder angle indicator to show full port and starboard angles. LEGACY COMPONENT DESC: Rudder Angle Indicator
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 January 2004
Resolved
Provide personnel for manning bridge, main, and second deck galley until smoke detection system has been placed in normal operations when passengers are on board. LEGACY COMPONENT DESC: Smoke Detectors
Construction/Loadline › Hull
Issued 7 January 2004
Resolved
Submit plans for 4-inch anode protection systems consisting of two penetrations (one each) of port and starboard seachests to CG [name withheld], Florida for approval. LEGACY COMPONENT DESC: Bottom Plating
Construction/Loadline › Hull
Issued 5 January 2004
Resolved
Prior to carriage of passengers and after anode installation is completed have inspected by a CG marine inspector. LEGACY COMPONENT DESC: Bottom Plating
Communications › Radio Communications
Issued 2 December 2003
Resolved
provide an FCC operating permit for [name withheld] COMPONENT DESC: FCC operating permit
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 2 December 2003
Resolved
Provide a emergency light in 2nd deck ladder landing. LEGACY COMPONENT DESC: Emergency lighting
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 2 December 2003
Resolved
Replace all electrical receptacles in wet bar areas to GFI receptacals. LEGACY COMPONENT DESC: Junction Box
Electrical › Lighting (service) › Outlet Box
Issued 2 December 2003
Resolved
Install a latch in electrical panel P-2 IWO dry store compartment.
Engineering › Steering Gear System › Pump
Issued 2 December 2003
Resolved
Replace leaking fitting in STBD side steering pump.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 December 2003
Resolved
Replace the double set of emergency lights at engine room door, bottom of ladder and on the PORT side.
Construction/Loadline › Penetrations
Issued 2 December 2003
Resolved
Prior to the carriage of passengers, insulate A-Class pipe penetrations for all CO2 beverage lines as required by 46CFR116.415(a)(2)(ii).
Accommodation/Occupational Safety › Occupational Safety
Issued 2 December 2003
Resolved
Prior to the carriage of passengers, ensure proper operation of 2nd deck galley door on PORT side.
Operations/Management › FireFighting › Patrol System (Special Category Spaces)
Issued 2 December 2003
Resolved
Verify and update fire control plans, and general arrangement plan for the 3rd deck, audio/visual rooms, photograph room, and gift shop. Ensure proper catagorazation of spaces and proper construction. LEGACY COMPONENT DESC: Plans
Construction/Loadline › Structures
Issued 27 November 2002
Resolved
REPAIR LATCH ON PORT AFT MAIN DECK WEATHER DOOR. LEGACY COMPONENT DESC: Door
Construction/Loadline › Structures
Issued 27 November 2002
Resolved
REPAIR SELF CLOSURE ON DISHWASHER ROOM WEATHER DOOR. LEGACY COMPONENT DESC: Door
Operations/Management › Equipment Service/Testing
Issued 27 November 2002
Resolved
INITIATE EPIRB TESTING LOG. LEGACY COMPONENT DESC: EPIRB
Engineering › Compressed Air System (control)
Issued 27 November 2002
Resolved
MAKE PORT AIR RECEIVER READY FOR INSPECTION. LEGACY COMPONENT DESC: Receiver/Bottle
Accommodation/Occupational Safety › Occupational Safety
Issued 27 November 2002
Resolved
PROVIDE EMERGENCY LIGHTING IN ENGINE ROOM AND DRY STORES AS DISCUSSED. LEGACY COMPONENT DESC: Emergency Lighting
Electrical › Electrical Distribution System (service)
Issued 27 November 2002
Resolved
INSTALL WET LOCATION OUTLETS IN REEF ROOM BAR AND STAR 1 BAR. LEGACY COMPONENT DESC: Outlet Box
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 November 2002
Resolved
PROVIDE CURENT CREW LIST OF ALL PERSONNEL SUBJECT TO CHEMICAL TESTING.
Personnel › Training
Issued 27 November 2002
Resolved
PROVIDE COMPANY TRAINING/QUALIFICATION PROGRAM FOR VESSEL ENGINEER. PROVIDE DOCUMENTATION TO THE OCMI FOR ACCEPTANCE OF TRAINING PROGRAM AND PERSONNEL QUALIFIED UNDER THIS PROGRAM. LEGACY COMPONENT DESC: Diesel Engineering
Documentation › Manuals/Policy Documentation
Issued 27 November 2002
Resolved
PROVIDE UPDATE TO CONTINGENCY AND ACTION PLAN DATED FEB 2000 FOR [name withheld] COMPONENT DESC: Company Action Plan (SIP)
Lifesaving
Issued 24 October 2001
Resolved
Provide additional donning placards for lifejackets, 46CFR122.516.
Navigation
Issued 24 October 2001
Resolved
Make operational #1 steering pump, prior to carrying passengers.
Fire Fighting
Issued 24 October 2001
Resolved
Conduct fire and abandon ship drills in the presence of a CG marine inspector, prior to carrying passengers.
Documentation
Issued 24 October 2001
Resolved
Provide passenger safety orientation as required by 46CFR122.506.
Electrical
Issued 24 October 2001
Resolved
Ensure all electrical installations meet 46 CFR 120.
Lifesaving
Issued 24 October 2001
Resolved
Provide 406 MHz EPIRB for upgrade of route to limited coastwise, per _x001C_ 46 CFR 117.207, prior to carrying passengers.
Lifesaving
Issued 24 October 2001
Resolved
Provide 6 additional red flares, 46CFR117.68. Prior to carrying passengers.
Engineering
Issued 24 October 2001
Resolved
Repair exhaust fan in engine room, 46CFR19.465, prior to carrying_x001C_ passengers.
Fire Fighting
Issued 24 October 2001
Resolved
Test all fire and smoke detectors.
Documentation
Issued 24 October 2001
Resolved
Provide approved structural fire protections plans as submitted for inital certification, 46CFR116.202.
Documentation
Issued 24 October 2001
Resolved
Provide emergency evacution plan, 46CFR116.520.
Documentation
Issued 24 October 2001
Resolved
Provide fire extinguisher servicing certificate for annual service, fixed and portable, 46CFR115.810, 118.500.
Fire Fighting
Issued 24 October 2001
Resolved
Ensure all fire doors close properly as required per 46CFR116.435. No gapsgreater than 0.125 inch. Prior to carrying passengers.
Documentation
Issued 24 October 2001
Resolved
Provide an annual drug and alcohol program for vessel's crew, 46CFR Part 16, prior to carring passengers.
Documentation
Issued 24 October 2001
Resolved
Provide a lifesaving equipment maintenance record, 46CFR122.702.
Documentation
Issued 24 October 2001
Resolved
Provide evidence that the vessel's elevator meets the standards outlined in ANSI A17.1, 46 CFR 120.540. Replace missing phone in elevator.
Fire Fighting
Issued 24 October 2001
Resolved
Replace all missing insulation on structural fire protection boundries as required by 46 CFR 116.
Lifesaving
Issued 24 October 2001
Resolved
Ensure that all decks are marked with total amount of passengers that can be carried on each deck, 46CFR122.602(g).
Electrical
Issued 24 October 2001
Resolved
Ensure that all emergency lighting is operating properly, 46CFR120.432
Electrical
Issued 24 October 2001
Resolved
Ensure that emergency lighting for the rescue boat can be illuminated with the emergency lighting, 46CFR111.75-16.
Lifesaving
Issued 24 October 2001
Resolved
Place co2 cylinders located in the store room into a rack for storage.
Lifesaving
Issued 24 October 2001
Resolved
Secure ice machine on the second deck.
Engineering
Issued 24 October 2001
Resolved
Label fuel shut off valves at location.
Engineering
Issued 24 October 2001
Resolved
Remove covers from fuel vents.
Documentation
Issued 26 January 2001
Resolved
PROVIDE VALID FCC SAFETY RADIO CERTIFICATE.
Lifesaving
Issued 30 November 1999
Resolved
PROVIDE A SAFE LAUNCHING AND RECOVERY PROCEDURE FOR AN APPROVED RESCUE BOATTO INCLUDE A SAFE MEANS TO LIFT AND PLACE THE RESCUE BOAT IN ITS CRADLE._x001C_ PRIOR TO 02 JAN 00.
Documentation
Issued 30 November 1999
Resolved
OPERATOR SHALL PROVIDE A RISK ASSESSMENT FOR PROVISIONAL ROUTE TO ASSIST INTHE EVALUATION OF THE REQUIREMENTS OF 46 CFR 117-207 TO THE SATISFACTION OFTHE OCMI PRIOR TO 03 FEB 00._x001C_
Deck/Cargo
Issued 24 November 1999
Resolved
PROVIDE VESSELS ANCHOR CHAIN WITH A POSITIVE HOLDING DEVICE, I.E. PELICAN HOOK TO PROVENT PASENGERS/CREW FROM ACCIDENTLY RELEASING THE ANCHOR.
Lifesaving
Issued 24 November 1999
Resolved
PROVIDE A SAFE LAUNCHING AND RECOVERY PROCEDURE FOR THE RESCUE BOAT TO INCLUDE A SAFE MEANS TO LIFT AND PLACE THE RESCUE BOAT IN IT'S CRADLE.
Accommodation/Occupational Safety
Issued 24 November 1999
Resolved
REPOSTION AND SECURE TO DECK THE 2ND DECK FIXED SEATING LOCATED IN THE STERN LOUNGE AREA ENSURING THEY MEET THE MINIMUM CLEARANCE (34") AS REQUIRED BY 46 CFR 116.438(n)(2)(iii)(D).
Fire Fighting
Issued 24 November 1999
Resolved
PROVIDE AND PERMANENTLY INSTALL THE OPERATION INSTRUCTONS, LABLE EACH SYSTEM AND PROVIDE THE PIPING DIAGRAMS AS REQUIRED BY 46 CFR 122.612 FOR THE FIXED CO2 FIRE EXTINGUISHING SYSTEM.
Lifesaving
Issued 24 November 1999
Resolved
OPERATOR SHALL PROVIDE A RISK ASSESMENT FOR PROVISIONAL ROUTE TO ASSIST IN THE EVALUATION OF THE REQUIREMENTS OF 46CFR 117-207 TO THE SATISFACTION OF THE OFFICER IN CHARGE MARINE INSPECTION PRIOR TO 03 FEB 2000.
Lifesaving
Issued 24 November 1999
Resolved
RESUBMIT TO MSO MOBILE FOR APPRV'L LIFESAVING PLAN ADDRESSING THE FOLLOWINGITEMS; 1)LIFERING LIGHT RELOCATION FROM ORGINAL LOCATION 2)DELETE 48 PFD'S FM MN DK INTERIOR 3)ADJUST MN DK SEATING PFD COUNT 4)CORRECT LOCATION CHILDPFD 5)ADD 2ND FIRE DOORS 6)CORRECT PLACEMENT WORDING OF 2ND DK LOCATION.
Fire Fighting
Issued 24 November 1999
Resolved
PROVIDE AND DEMONSTRATE THE CAPABILITY OF BOTH GALLEY SLIDING FIRE SCREEN DOORS TO CLOSE AND LATCH IN THE CLOSED POSITION AS REQUIRED BY 46 CFR 116.435(c)(3).
Electrical
Issued 24 November 1999
Resolved
PROVIDE AND DEMONSTRATE OPERATION AN EMERGENCY LIGHT FOR THE ILLUMINATION OF THE RESCUE BOAT LANDING AREA.
Documentation
Issued 24 November 1999
Resolved
PROVIDE COPY OF THE FCC ISSUED RADIO STATION LICENSE TO THE MARINE SAFETY OFFICE, MOBILE ONCE ISSUED TO ALLOW THE UPDATING OF THE MARINE SAFETY INFORMATION SYSTEM.
Accommodation/Occupational Safety
Issued 24 November 1999
Resolved
DEMONSTRATE PROPER OPERATION OF THE VESSEL INSTALLED COMMUNICATION SYSTEM.
Lifesaving
Issued 24 November 1999
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS AND TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR, COMPLETE PERMANENT INSTALLATION OF ALL REQUIRED SAETY/FIRE/HULL MARKINGS.
Lifesaving
Issued 24 November 1999
Resolved
INSTALL AND DEMONSTRATE OPERATIN OF THE PA SYSTEM FOR THE MAIN AND 2ND DECKGALLEY AREAS.
Accommodation/Occupational Safety
Issued 24 November 1999
Resolved
COMPLETE THE INSTALLATION OF THE MAIN DECK GALLEY AREA HEAD INSTALLED HAND DRYER.
Electrical
Issued 24 November 1999
Resolved
COMPLETE THE INSTALLATION OF ALL DROP CEILING TILING, AND COMPLETE THE INSTALLATION OF ACCENT LIGHTING INTO THE CEILING TILES. ALSO DEMOSTRATE OPERATION OF ALL CEILING BOARDER ACCENT LIGHTS/CONTROLS.
Fire Fighting
Issued 24 November 1999
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, DEMOSTRATE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR THE VESSELS CREW PROFICIENCY AT THE FIRE DRILL. TO INCLUDE KNOWLEDGE OF FIRE DAMPER LOCATIONS, OPERATION OF THE FIXED CO2 SYSTEM AND PASSENGER REFUGE AREAS.
Accommodation/Occupational Safety
Issued 24 November 1999
Resolved
CONDUCT GENERAL SHIPBOARD CLEAN UP OF VESSEL, REMOVE ALL COMBUSTIBLE PROTECTIVE COVERINGS PRIOR TO COMMENCING PASSENGER OPERATIONS.
Lifesaving
Issued 24 November 1999
Resolved
COMPLETE THE RESCUE BOAT CERTIFICATION PROCESS AS PER DIRECTION FROM MARINESAFETY OFFICE MOBILE E-MAIL OF 23 NOV 99. TO BE SATISFIED WHEN RESCUE BOATAPPROVAL HAS BEEN GRANTED VIA LETTER FROM MSO MOBILE.
Lifesaving
Issued 24 November 1999
Resolved
BY 10 DEC 99, PROVIDE TO MSO MOBILE DOCUMENTATION OF SATISFACTORY COMPLIANCE WITH THE REQUIREMENTS OF THE DRUG TESTING PROGRAM AS PER 46 CFR 16.
Fire Fighting
Issued 24 November 1999
Resolved
RESUBMIT FIRE CONTROL PLAN TO MSO MOBILE WITH CORRECTIONS FOR APPROVAL AS FOLLOWS, 1)ADDITIONAL B2 AT BOW THRUSTER ENTRANCE 2)CORRECT VOID SPACE FIRECLASSIFICATION 3)ADDITION OF FIRE DOORS TO 2ND DECK MIN-SHIP, PT/ST SIDE.
Navigation
Issued 24 November 1999
Resolved
PROVIDE COAST GUARD LIGHT LIST FOR AREA OF OPERATIONS.
Fire Fighting
Issued 24 November 1999
Resolved
RESUBMIT TO THE CG MARINE SAFETY CENTER A REVISED SFP DRWG (98-727-3510) INDICATING THE ADDITION OF THE FIRE DOORS ON THE 2ND DECK MID-SHIP LOCATION, ALSO ADDRESSCORRECT VOID SPACE CLASSIFICATION ISSUES AS PER COMMENT 1, MSC LTR DTD 6NOV98, SER NO. H2-9803759.
Lifesaving
Issued 24 November 1999
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, DEMOSTRATE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR THE CREWS PROFICIENCY TO CONDUCT AN ABANDON SHIP DRILL.
Casualty record · 7
31 August 2006Routine · role: Involved in a Marine Casualty · activity 2779245
25 February 2007Routine · role: Involved in a Marine Casualty · activity 2882562
3 March 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2881774
20 April 2007Routine · role: Involved in a Marine Casualty · activity 2926958
14 July 2013Routine · role: Involved in a Marine Casualty · activity 4654670
26 June 2016Routine · role: Involved in a Marine Casualty · activity 5937916
16 June 2019Routine · role: Involved in a Marine Casualty · activity 6724293
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.