MAURY USCG vessel records
← All vessels

STARSHIP

STARSHIP is a 1999 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2016, most recently in March 2026, along with 78 deficiencies, 2 operational controls and 7 casualty investigations between 2006 and 2019.

Records from 2006 to 2026. Most recent: inspection, 9 March 2026.

Built
1999
Last inspected
9 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 March 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF8292
504648
Flag
UNITED STATES
Maury page id
psix-504648

Documentation record

Registered dimensions (L × B × D)147.7 ft × 42.0 ft × 7.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)147.7 ft × 42.0 ft × 7.0 ft
ITC tonnagegross 1,127 / net 365
BuilderFREEPORT SHIPBLDG HULL #261 INC · FREEPORT, FL, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
1127 - Convention (Subpart B), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
365 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 35

9 March 2026 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8323240
12 January 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8295323
16 December 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8284147
15 September 2025 Deficiency Check · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8235105
28 May 2025 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8148401
31 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8102936
5 August 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7975225
28 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7891557
17 August 2023 In-Service Inspection · Plan Review (Other than "T")
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7770440
1 August 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7757895
23 May 2023 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7662363
8 August 2022 Hull Examination · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7528287
29 July 2022 Load Line/Change of Employment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7511989
7 July 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7499711
18 April 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7405954
21 October 2021 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7330776
3 May 2021 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7172951
21 August 2020 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7026016
15 June 2020 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6965408
30 October 2019 Administrative Inspection · Security Breach, Potential
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6845717
23 September 2019 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6819050
16 June 2019 Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6716466
16 June 2019 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6724293
10 June 2019 Annual Inspection · MTSA Verification · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6664440
18 September 2018 Deficiency Check · Drydock Exam · Internal Structural Exam · Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6533342
31 July 2018 Annual Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6482655
29 June 2018 Deficiency Check · Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6459534
1 August 2017 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6215099
13 September 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995449
30 August 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6009783
23 August 2016 Administrative Inspection · Excursion Permit
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5980902
26 June 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5919444
26 June 2016 Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5933788
26 June 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5937916
29 April 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5865350

Deficiency record · 78

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 December 2025 Resolved
46 CFR 120.310(a) Each vessel that relies on electricity to power the vital systems must be arranged so that the loads can be energized from two sources of electricity. O/O notified office that they identified an issue with port generator while conducting routine maintenance. Generator is not operational. CODE 705: Vessel must operate within the parameters of the approved waiver to continue commercial operations with one generator.
Action required: 705 - Other - as specified
Due 16 December 2025
Resolved 27 December 2025
Resolution: Received technician service report. Attached in documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 May 2024 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. MI observed exhaust leaks on both main diesel engines and the bow thruster engine while operating. 46 CFR 119.430(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 30 May 2024
Resolution: Vessel rep provided picture of main engine exhaust flanges and the bow thruster engine flange with tightened and secured bolts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operations. MI observed emergency fuel shutoff labeling was missing direction of operations. 46 CFR 122.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 30 May 2024
Resolution: Vessel rep provided picture of labeled emergency fuel shutoff station.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 28 May 2024 Resolved
The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. MI observed loose dogs on the engine room emergency escape hatch and a loose handle on the engine room door. 46 CFR 116.500(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 30 May 2024
Resolution: Vessel rep provided picture of secured emergency escape hatch.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed three electrical wires hanging from the ceiling in the lazarette compartment. 46 CFR 120.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 11 June 2024
Resolution: Vessel rep provided a photo of the electrical wires in the lazarette compartment closed off and labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 May 2024 Resolved
The Vessel Security Officer must, for each vessel for which he or she has been designated: ensure security equipment is properly operated, tested, calibrated and maintained. MI observed vessel did not have maintenance records for security screening wand on board past 2022. Vessel must conduct maintenance in accordance with manufacturers' instructions. 33 CFR 104.215(e)(10)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2024
Resolved 10 June 2024
Resolution: Vessel rep provided picture of security wand maintenance log.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 May 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed two adult life jackets were unserviceable. Vessel's adult life jackets total is 722. 46 CFR 117.71(a)
Action required: 10 - Deficiency Rectified
Due 28 May 2024
Resolved 28 May 2024
Resolution: Replaced on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 May 2024 Resolved
Minimize accidental personnel contact with energized parts. MI observed a missing switch in a breaker panel on vessel's second deck and had not been blanked off. 46 CFR 120.200(c)
Action required: 10 - Deficiency Rectified
Due 28 May 2024
Resolved 28 May 2024
Resolution: Blank installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 May 2023 Resolved
A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead. MI observed that the sliding fire door separating the galley from the accommodation space door frame was not secured to the bulkhead properly allowing the door frame to protrude off the bulkhead. Vessel will repair/restore the fire boundary prior to the carriage of passengers. 46 CFR 116.435(C)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2023
Resolved 25 May 2023
Resolution: Vessel POC sent pictures showing the repairs to clear the deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 May 2023 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. Unless specifically permitted in 400.7, flexible cords and cables shall not be used for as a substitute for the fixed wiring of a structure. MI found non-portable fans on upper deck found to be powered by temporary cables. 46 CFR 120.340(r) 46 CFR 111.60-13(b)(1) NFPA NEC 2002 400.8(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 31 May 2023
Resolution: Vessel POC sent pictures showing correct install of the fans power cables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2023 Resolved
Each ring life buoy on a vessel must: Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI observed the port aft main deck life buoy to not have the identification tag with an approval number. 46 CFR 117.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 25 May 2023
Resolution: Vessel POC sent pictures showing the new life buoy in service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2023 Resolved
Each hose must: Be lined commercial fire hose that conforms to UL 19 “Standard for Safety for Lined Fire Hose and Hose Assemblies” (incorporated by reference, see § 114.600 of this chapter), or hose that is listed and labeled by an independent laboratory recognized by the Commandant as being equivalent in performance. MI observed a hole in the fire hose at the fitting connected to the hydrant. Vessel has procured new hose. 46 CFR 118.320(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 30 May 2023
Resolution: Vessel POC provided pictures showing new fire hose in service.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 April 2022 Resolved
Each fire hose must be lined commercial firehose that conforms to UL 19. MI found firehose for Fire Station #3 leaking at connection to hydrant. 46 CFR 118.320(b)(1)
Action required: 10 - Deficiency Rectified
Due 18 April 2022
Resolved 18 April 2022
Resolution: Replaced with new hose while MI onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 April 2022 Resolved
Each life jacket must be marked with Type 1 retro-reflective material. MI found 03 life jackets requiring new retro-reflective material. 46 CFR 122.604(h)
Action required: 10 - Deficiency Rectified
Due 18 April 2022
Resolved 18 April 2022
Resolution: Replaced retroreflective material on 03 life jackets while MI onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 April 2022 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. Unless specifically permitted in 400.7, flexible cords and cables shall not be used for as a substitute for the fixed wiring of a structure. MI found non-portable fans on upper deck found to be powered by temporary cables. Provide repair proposal. 46 CFR 120.340(r) 46 CFR 111.60-13(b)(1) NFPA NEC 2002 400.8(1)
Action required: 705 - Other - as specified
Due 30 August 2022
Resolved 31 May 2023
Resolution: During 2023 Annual inspection deficiency was still outstanding. 835 Deficiency was reissued during inspection and rectified on this date. See activity number 7662363
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 May 2021 Resolved
In fire detection and alarm systems with addressable detectors and manual pull stations, every fault must be monitored and must not prevent the continued individual identification of the remaining detectors. After testing the smoke detector on the bridge, no other smoke detector would activate throughout the ship. Prove full operational capability of fire detection system prior to carrying passengers. 46 CFR 76.27.10(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2021
Resolution: Technician attended vessel and tested all smoke detectors with smoke can and all heat detectors with heat gun; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 May 2021 Resolved
The A-60 fire boundary from bow thruster to main galley room/ball room was missing insulation in multipile areas and would not prevent passage of smoke/flame for specified time. 46 CFR 116.415
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 27 May 2021
Resolution: Vessel rep replaced insulation and secured with fire resistant tape.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2021 Resolved
The fuel lines to the starboard MDE fuel pressure gauge and the port MDE oil pressure gauge are cotton sleeved and pose a fire hazard. 46 CFR 119.455
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 15 May 2021
Resolution: Vessel rep replaced line to stbd MDE fuel pressure gauge and port MDE oil pressure gauge.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2020 Resolved
The following spaces must be equipped with a fire detection and alarm system, except that when a fixed gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed: (1) A space containing propulsion machinery. The heat detection probe in the bow thruster room was painted over, changing the heat detection properties of the sensor. 46 CFR 118.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 24 June 2020
Resolution: Verified heat detection probe in bow thruster room was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Terminal connections to port battery in bow thruster compartment secured via wing nuts. 46 CFR 120.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 16 June 2020
Resolution: Verified wing nuts removed and hex nuts installed on batteries.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Junction box in fuel tank compartment was not securely mounted. 46 CFR 120.2020 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 16 June 2020
Resolution: Junction box secured to overhead.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020 Resolved
All electrical equipment and circuits must be clearly marked and identified. Distribution panels in the following locations were missing or had inaccurate circuit directories: -Third Deck Bar -Galley -Wine Room -Port Side Second Deck for "Starboard Nav. Lights" -Dry-stores(2x) 46 CFR 120.220 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 24 June 2020
Resolution: Verified O/O correctly labeled distribution panel directories.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 June 2020 Resolved
A shutoff valve must be located where the cooler piping penetrates the shell, as near the shell as practicable, except where the penetration is forward of the collision bulkhead. Starboard keel cooler shut off valve in lazarette was missing handle. 46 CFR 119.422 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 16 June 2020
Resolution: Keel Cooler shut off valve handle reattached to valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 June 2019 Resolved
The engine head, block, and exhaust manifold must be water jacketed and cooled by water from a pump that operates whenever the engine is operating. Prior to getting underway or operating generators, provide technician report attesting to the proper repair and operation of the port generator prime mover. 46CFR119.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2019
Resolved 19 June 2019
Resolution: Received technician report of coolant hose replacement; witnessed operational test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2019 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the cognizant [name withheld] side engine room fire extinguisher at ladder well mounted using a hook and a hose clamp. Mount extinguisher in accordance with manufacturer's recommendation. 46 CFR 118.520
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 13 June 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 June 2019 Resolved
The following spaces must be equipped with a fire detection and alarm system, except that when a fixed gas fire extinguishing system that is capable of automatic discharge upon heat detection is installed: (1) A space containing propulsion machinery. The heat detection probe in the port side engine room was painted over, changing the heat detection properties of the sensor. Clean to original. 46 CFR 118(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 13 June 2019
Resolution: Operator replaced heat sensor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 June 2019 Resolved
Each Class 1 door must have a quick action closing device operative from both sides of the door. The watertight door at the entrance to the engine room did not close completely with the closing device. Repair.46 CFR 116.100(b)46 CFR 170.270(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 13 June 2019
Resolution: Witnessed proper operation of watertight door.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 June 2019 Resolved
If installed, a hold back mechanism for a door must allow the door to be released. The 2nd Deck galley sliding fire screen door did not close properly when released from the bridge control station. Repair as original. 46 CFR 116.435(c)(6)(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 13 June 2019
Resolution: Witnessed proper operation of fire screen door.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 June 2019 Resolved
A door in a bulkhead required to be a A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead. Fire doors leading from the main deck galley out to the whether deck and to the storage room were missing gasket material. Replace as original. 46 CFR 116.435(c)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 13 June 2019
Resolution: Operator installed gasket material.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Forward mast light was inoperable. Repair or replace. 46 CFR 120.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2019
Resolved 13 June 2019
Resolution: Verified operation of mast head light.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop/renew 2 sections on port side of bow in forepeak prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 19 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop/renew section along stbd side shell, bulkhead ivo port damper side shell, and damper frame in bos thruster compartment prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 19 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop/renew bottom plate ivo keel in fuel void prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 19 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop and renew bulkhead along 2 bays in lazarette prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 19 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop/renew stbd hull forward of exhaust discharge prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 19 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop/renew 2nd deck galley prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 19 September 2018
Resolved 2 April 2019
Resolution: Wasted area cropped and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Repair 03 welds on stbd hull prior to credit drydock iaw 46CFR115.600 (a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Clean and gauge port and stbd exhaust dischage ports prior to credit DD iaw 46CFR155.600(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2018
Resolved 19 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Repair/replace forepeak hatch prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2018
Resolved 8 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2018 Resolved
At each initial and subsequent inspection for certification of a vessel the owner shall have the vessel ready for inspections of machinery. Repair/replace leaking capstan motor iaw 46CFR115.804
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2018
Resolved 8 October 2018
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop/renew center frame in forepeak prior to credit DD iaw 46CFR115.600(a).
Due 18 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Remove contents in fore peak and guage bow ivo center line iaw 46CFR115.600(a).
Due 18 September 2018
Resolved 19 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Crop/renew wasted fire damper ivo bow thruster room prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 18 September 2018
Resolved 23 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Clean and gauge deck in bow thruster room ivo bilge suction area prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 18 September 2018
Resolved 19 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. In fuel compartment gauge forward stbd side and area ivo bilge suction prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 18 September 2018
Resolved 19 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Clean and gauge under port chiller in engine room prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 18 September 2018
Resolved 19 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Clean and gauge under port shaft prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 18 September 2018
Resolved 19 September 2018
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 September 2018 Resolved
The owner or managing operator shall make a vessel available for dry-dock examinations and internal structural exmainations. Gauge second deck galley prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 18 September 2018
Resolved 19 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 18 September 2018 Resolved
In the application of inspection standards due consideration must be given to the hazards involved in the operation permitted by the vessel's COI. Replace bilge suction strainer in potable water void and in fuel compartment prior to credit DD iaw 46CFR115.600(a).
Condition: Improper/Lack of Maintenance
Due 18 September 2018
Resolved 23 September 2018
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2018 Resolved
If a cylinder is discharged and more than 5 years have elapsed since the last test, it must be retested before recharging. MI observed accidental discharge of fixed CO2 system in bow thruster room. Vessel Rep must hydro cylinders, flex tubes, provide tech report. MI present for tech testing. 46CFR147.65(a)(1)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: Received Tech report. MI inspected cylinders while attending vessel.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 31 July 2018 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. MI observed crew members lacking proper training on fire extinguishing systems on board.46CFR122.524(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: MI witnessed training records and increased crew proficiency.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 31 July 2018 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.46CFR122.520(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: MI witnessed satisfactory MOB, fire, and abandonship drills.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 July 2018 Resolved
A vessel must have a sufficient number of fire hydrants to reach any part of the vessel using a single length of fire hose. MI observed #5 fire station inaccessible. 46CFR118.310(a)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: MI observed repaired fire station.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 July 2018 Resolved
A door must have a latch with a minimum throw of 20 millimeters. MI observed stbd side second deck fire door did not latch. 46CFR114.400(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: MI witnessed satisfactory operation of fire door.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 July 2018 Resolved
High risk service spaces (9) include galley; large laundry or drying room; garbage or trash disposal storage area; paint or lamp locker; cleaning gear locker or small storeroom in an accommodation area; mail or baggage room; and pantries and storerooms which contain flammable liquids or have a deck area not less than 5 square meters including connecting alleyways and stairs. MI observed furniture in galley space designated as a high risk service space being used improperly as a storage locker. 46CFR116.435(c)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: MI observed high risk service space clear of stored items.
02 - Structural Conditions › N/A - No Subsystem › Information on the A/A-max Ratio (Roro/pass. only)
Issued 31 July 2018 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed stbd side exhaust fan in engine room covered in oil and cluttered. 46CFR120.200(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: MI observed fan cleared and free of hazards.
11 - Life Saving Appliances › N/A - No Subsystem › Anti-exposure suits
Issued 31 July 2018 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MI observed 01 life buoy in need of replacement. 46CFR117.70(a)(3)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: Ring life bouy replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2018 Resolved
At least one ring buoy must be fitted with a floating waterlight, unless the vessel is limited to daytime operation, in that case no floating waterlight is required. MI observed that waterlight is inoperable. 46CFR117.70(d)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: Waterlight replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 31 July 2018 Resolved
If a vessel operates on exposed or partially protected waters, an opening port light is not permitted below the weather deck unless it has an inside, hinged dead cover. MI observed wasted hatch leading to steering gear compartment. To be repaired during next DD. 46CFR171.119(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2018
Resolution: Hatched replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 July 2018 Resolved
The emergency lighting required by paragraph (a) of this section must automatically actuate upon failure of the main lighting system. MI observed multiple emergency lights that were inoperable. 46CFR120.432(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2018
Resolution: E lighting fully functional
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 July 2018 Resolved
A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. MI observed hole/leak ivo main deck/engine room bulkhead; ivo bar and pipe with soda lines. To be repaired during next DD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2018
Resolution: Hole/leak repaired
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 31 July 2018 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Provide updated charts for area of operations. MI observed navigation charts are out of date. 46 CFR 121.420 (a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2018
Resolution: New valid charts purchsed
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 July 2018 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with mat black inboard screens and meet the requirements of 84.17. Navigation light screens are faded. Repaint light screens to a mat black. Inland Navigation Rules Annex I 84.09
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2018
Resolution: Inboard screens repainted mat black
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 July 2018 Resolved
Each ring life buoy on a vessel must: (3) Be stowed in a way that it can be rapidly cast loose: (4) Not be permanently secured in any way. Ring life buoy located on the port bridge wing was secured in place with banding strap. Vessel representative removed banding strap. 46 CFR 117.70(b)(3)(4)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 July 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 July 2018 Resolved
A weathertight door with permanent watertight coamings that comply with must be provided for each opening located in a deck house or companionway. Weathertight door located on 2nd deck portside aft leading to promenade deck does not close. Repair/replace 46 CFR 171.124(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2018
Resolution: Door replaced.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 31 July 2018 Resolved
An internal structural examination conducted in compliance with 115.600 of this part may be conducted while the vessel is afloat. Found deck located on the 2nd deck with in the galley area needs to be gauge during next drydock and provided findings to local marine inspector. 46 CFR 115.610(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2018
Resolution: Area gauged.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 July 2018 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant [name withheld] located on the portside in the steering compartment has two pinholes. Identify system piping is for and repair or replace piping. 46 CFR 119.700
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 September 2018
Resolution: Holes repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 31 July 2018 Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations and underwater surveys required by this section. At vessels next drydock make available for inspection suspect areas identified in the steering gear compartment by the attending marine inspector. 46 CFR 115.600(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 September 2018
Resolution: Area gauged
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 June 2018 Resolved
Exhaust gas must not leak from the engine or any connection. 03 pinhole exhaust leaks discovered on generator. Replace muffler in-kind. - 46CFR119.430(b) - 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2018
Resolved 20 July 2018
Resolution: Inspected repairs and witnessed proper operation of engine. No leaks were detected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 June 2018 Resolved
Exhaust gas must not leak from the piping or any connections. Multiple exhaust leaks discovered on port generator. Remove generator lagging and inspect all piping to identify for any additional leaks. Repair all leaks or replace exhaust piping. Tighten exhaust flange identified on starboard main diesel engine. - 46CFR119.430(b) - 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2018
Resolution: Welders effected repairs to exhaust piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 June 2018 Resolved
Except as otherwise provided in paragraph (b) of this section, all engines must be water cooled and meet the requirements of this paragraph. Engine salt water cooling line for bow thruster is leaking. Repair or replace. - 46CFR119.420(a) - 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2018
Resolution: Clad welds conducted to effect repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 29 June 2018 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be insulated where necessary to prevent injuries. Starboard main engine exhaust lagging is missing near the aft engine room bulkhead. Install lagging. - 46CFR116.970 - 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2018
Resolution: Additional lagging installed.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 1 August 2017 Resolved
Remove all non-metallic trash barrels onboard IAW 46 CFR 116.405(i).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Removed all non combustible waste receptacles.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 August 2017 Resolved
Repair latch on "wine room" fire door IAW 46 CFR 116.435.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Repaired latch on fire door.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 1 August 2017 Resolved
Replace SOLAS retro tape on 152 extended size and 35 childrens lifejackets IAW 46 CFR 117.71. Restricted to 0 children and 569 adults.
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 2 August 2017
Resolution: Replaced SOLAS tape on all affected lifejackets.
Fire Fighting › Combustible Materials › Facings/Mouldings/Decorations/Veneers
Issued 1 August 2017 Resolved
Remove combustibles from category 12 space on 3rd deck IAW 46 CFR 116.405(b).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Removed all combustibles from category 12 space.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 1 August 2017 Resolved
Repair latches on galley fire doors IAW 46 CFR 116.435.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2017
Resolution: Repaired latches and tested doors, all sat.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 26 June 2016 Resolved
Main generator breaker phase C is running at a higher temperature than usual. Make repairs to the main generator breaker panel to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2016
Resolved 8 July 2016
Resolution: MI attended vessel to observe load test on new 3 phase breaker. All sat.

Casualty record · 7

31 August 2006Routine · role: Involved in a Marine Casualty · activity 2779245
25 February 2007Routine · role: Involved in a Marine Casualty · activity 2882562
3 March 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2881774
20 April 2007Routine · role: Involved in a Marine Casualty · activity 2926958
14 July 2013Routine · role: Involved in a Marine Casualty · activity 4654670
26 June 2016Routine · role: Involved in a Marine Casualty · activity 5937916
16 June 2019Routine · role: Involved in a Marine Casualty · activity 6724293
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.