MEMORY is a 1978 freight ship. The Coast Guard has recorded 80 inspections since 1999, most recently in January 2024, along with 113 deficiencies and 30 operational controls.

Records from 1999 to 2024. Most recent: inspection, 27 January 2024.

Built
1978
Last inspected
27 January 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7713204 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP9695
504662
Flag
PANAMA
—
Maury page id
psix-504662

Inspections, by type

…with no type recorded49
Years with a record 13 calendar years (1999–2024)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1345 - Convention (Subpart B), Gross Ton
1345 - Regulatory (Subpart C or D), Gross Ton
771 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 80

27 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856541
24 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7854070
10 August 2014 Type not recorded
No type recorded · USCGC TAMPA (WMEC 902) · Activity 4977913
14 July 2009 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3535157
12 July 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3531087
22 April 2009 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3458469
20 April 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3454973
20 April 2009 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3455856
23 January 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3397224
23 January 2009 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3401618
24 October 2008 Ballast Water Examination · PI Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3350541
26 August 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3309447
8 July 2008 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3262419
17 April 2008 ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3186150
7 March 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3160045
5 March 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3159100
20 February 2008 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3150230
22 December 2007 PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3119765
12 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3114146
9 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3112273
8 June 2007 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2957097
6 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2952932
11 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2885617
10 March 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2885236
9 August 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2740961
9 August 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2861232
15 May 2006 Deficiency Check · Ballast Water Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2649588
14 May 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2648751
13 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2648091
13 April 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2624291
12 April 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2623065
19 March 2006 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2605279
16 March 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2603684
6 December 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2546733
6 December 2005 Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2546902
5 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2529787
4 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2528609
13 October 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2513667
12 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2512855
9 October 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2510932
23 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2499666
18 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2495648
29 August 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2478326
23 August 2005 MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Deficiency Check · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2472038
22 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2472546
19 August 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2468251
3 August 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2449716
29 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2443701
1 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2410062
1 June 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2376006
11 May 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2355617
8 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2351974
8 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2330989
6 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2328169
22 February 2005 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex II Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2297013
26 January 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2281152
17 August 2004 PI Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2168380
16 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2167374
26 March 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2031590
7 January 2004 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1977239
18 July 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1849827
17 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1849514
3 March 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1751771
10 February 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1742302
5 January 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1725958
3 August 2002 Type not recorded
No type recorded · USCGC KEY LARGO (WPB 1324) · USCG Northeast District (CGD-NE) · Activity 1657843
23 July 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1650887
17 June 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1632175
3 August 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1484528
13 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 291857
7 June 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 290802
25 April 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 732670
25 March 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 288874
19 March 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 732669
12 March 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 289494
22 August 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 281208
13 June 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 278881
20 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435815
19 September 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 432945
19 September 1999 Port Security Assessment
Type not classified · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 570807

Deficiency record · 113

Engineering › Generator (propulsion-electric) › Battery Charging Circuitry
Issued 14 July 2009 Resolved
Emergency generator alternator not capable of recharging batteries.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 July 2009 Resolved
Hand rail on port side is missing horizontal support bars.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 7 August 2009
Deck/Cargo › Mooring/Anchoring › Winch
Issued 14 July 2009 Resolved
Windlass hydraulic line is leaking fluid.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 7 August 2009
Lifesaving › Visual Distress Signals (General) › Condition
Issued 24 October 2008 Resolved
Signaling lamp is inoperable.
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 12 December 2008
Resolution: Signaling lamp repaired.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 24 October 2008 Resolved
Auto pilot lost power. Service tech to inspect prior to departure.
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 12 December 2008
Resolution: Auto pilot lost power repaired.
Engineering › Steering Gear System › Pump
Issued 24 October 2008 Resolved
Leaking hydraulic fluid from the steering helm pump.
Action required: 705 - Other - as specified
Due 24 November 2008
Resolved 12 December 2008
Resolution: Leaking hydraulic fluid from the steering helm pump repaired.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 August 2008 Resolved
Owner/operator failed to prepare and submit a nontank vessel response plan IAW 33 U.S.C 1321(j)(5).
Action required: 10 - Deficiency Rectified
Due 26 August 2008
Resolved 17 January 2024
Resolution: Vessel had subsequent exams marked as complete/narrative stated all sat.
Construction/Loadline › Hull › Bottom Plating
Issued 17 April 2008 Resolved
PSCOs noted numerous instances of hull damage severe enough to question the vessel’s seaworthiness: SEE NARRATIVE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2008
Resolution: PSCOs recieved Flag State Report attesting to proper repairs.
Deck/Cargo › Cargo Stowage › General
Issued 17 April 2008 Resolved
Starboard deck amidships- 2” hole through wasted metal leading to cargo hold –epoxy patch Starboard deck loadline deck mark is located above freeboard deck approximately 2”; Loadline certificate indicates deck line is 0 millimeters from freeboard deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2008
Resolution: PSCOs recieved Flag State Report attesting to proper repair.
Construction/Loadline › Markings › Load Line Mark
Issued 17 April 2008 Resolved
Loadline certificate indicates deck line is 0 millimeters from freeboard deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 8 July 2008
Resolution: PSCOs received Flag State Report attesting to proper repairs.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 April 2008 Resolved
Ladder rungs wasted, bent, missing - forward cargo hold ladder and starboard side midship deck ladder to cargo hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 July 2008
Resolution: PSCOs received Flag State Report attesting to proper repairs.
Navigation › Piloting/Steering › Marine Charts
Issued 17 April 2008 Resolved
Vessel does not have updated and current charts for their route into Jacksonville, Fl.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2008
Resolution: Corrected, see attached "MENDIONDOREPORT"
Lifesaving › Lifebuoys › Serviceable
Issued 17 April 2008 Resolved
Forward life ring and life ring located between the super structure and cargo hold are unserviceable. (exterior cover cracked and exposing core)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2008
Resolution: Corrected with new transformer installed, see attached "MENDIONDOREPORT"
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 17 April 2008 Resolved
Vessel has 03 lifeboat radios but 01 of them is non-functioning.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2008
Resolution: Corrected with new transformer installed, see attached "MENDIONDOREPORT"
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 April 2008 Resolved
Exposed wiring in crew’s and officers’ mess.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2008
Resolution: Corrected with new transformer installed, see attached "MENDIONDOREPORT"
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 17 April 2008 Resolved
Vessel does not appear to be following SMS procedures regarding non conformity reports/ resolution. SEE NARRATIVE
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2008
Resolution: PSCOs received Flag State Report attesting to proper repairs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 April 2008 Resolved
Vessel is missing paneling along with insulation on 03 decks that insulates/ protects accommodation spaces from the funnel. The current condition poses a fire and safety hazard to the crew. Both the captain and C/E confirm that there had been an exhaust leak that covered the same area of the missing panels, the leak was fixed but the paneling/ insulation has not been replaced for a period/ 2mths
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2008
Resolution: Corrected with new transformer installed, see attached "MENDIONDOREPORT"
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 20 February 2008 Resolved
21DEC2007: Vessel failed to report into the WHALESSOUTH Mandatory Ship Reporting System while transiting into the Port of Brunswick, Ga.
Condition: Unknown
Due 5 March 2008
Resolved 5 March 2008
Resolution: LOW
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 December 2007 Resolved
The vessel's cargo hold was found to be compromised due to 6 holes identified in cargo hold covers. Four more holes were found during a further investigation which had been patched and painted over. The weather tightness of the vessel cargo hold covers do not comply with the regulations. Vessel is to repair or replace cargo hold covers.
Action required: 705 - Other - as specified
Resolved 28 December 2007
Construction/Loadline › Hull › Hull Plating
Issued 22 December 2007 Resolved
PSCO's identified a hole in the ship's bow, between the 46 and 48 depth mark above the bulbous bow. Water witnessed leaking from hole is coming from the forward ballast tank.
Action required: 705 - Other - as specified
Resolved 28 December 2007
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 22 December 2007 Resolved
PSCO's unable to identify watertight integrity of the cargo hold due to cargo in hold. Water was observed in tanks but origin unknown. Classification Society surveyor to confirm watertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2007
Operations/Management › Drills/Instruction › Fire
Issued 22 December 2007 Resolved
During the review of the ship's log book PSCO's identified there has been no fire or abandon ship drill conducted since 26NOV07. There was a 50% crew change out between the 14th and 18th of Dec 2007 in Miami, FL.
Action required: 705 - Other - as specified
Resolved 28 December 2007
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 22 December 2007 Resolved
An unauthorized flex pipe connected from the OWS to the slop tank. PSCO's removed the pipe and discovered it could be connected directly to an overboard discharge outlet.
Action required: 705 - Other - as specified
Resolved 28 December 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 December 2007 Resolved
Chief Engineer and crew failed to show the proper operation of the Oily Water Separator. The vessel's crew attempted on approx. 6 separate occasions to operate the OWS but could not make it work.
Action required: 705 - Other - as specified
Resolved 28 December 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 December 2007 Resolved
PSCO's found the OWS 15 ppm alarm to be disabled. Witnessed Chief Engineer contact the disconnected wires together to make the audible alarm sound. Prior to departure
Action required: 705 - Other - as specified
Resolved 28 December 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 December 2007 Resolved
PSCO's found 7 of the 11 lifebouys that have the vessel's name and port of registry to be worn off and unreadable. Prior to departure from port
Action required: 705 - Other - as specified
Resolved 28 December 2007
Deck/Cargo › Cargo Stowage › General
Issued 22 December 2007 Resolved
PSCO's located two concrete patches in the aft part of the cargo hold. Vessel did not have condition of class to verify when proper repairs are to be made in the cargo hold. On 19 Dec 2007, the cement patches were installed. Vessels master stated that cement was added to prevent cargo from going into bilge.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 December 2007 Resolved
The OWS discharge return line for the oily water exceeding 15 ppm was a plastic corrigated hose routed directly to the bilge. This hose has since been changed to a fixed pipe however, this pipe is still routed to the bilge, not to a dedicated bilge water holding tank. To the satisfaction of the vessel's flag administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 December 2007
Lifesaving › Lifeboat › Propulsion Engine
Issued 15 May 2006 Resolved
IAW SOLAS Cargo Ship Safety Equipment Form E, vessel is required one motorized lifeboat onboard. Vessel has lifeboat that is not equipped with a motor.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2006
Resolved 24 May 2006
Resolution: Observed installation and operation of motorized lifeboat as per Form E
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 May 2006 Resolved
Aft bulkhead in steering gear room has a 12inch by 12inch square hole cut out of steel bulkhead. Replace steel and make proper repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2006
Resolved 24 May 2006
Resolution: Observed permanent repair of 12 x 12 in. square hole previously cut in bulkhead of steering gear room.
Fire Fighting › Fire Main › Condition
Issued 15 May 2006 Resolved
Fire main piping located by port side superstructure staircase is wasted. Marine Inspector put a hole in the piping with inspection hammer.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2006
Resolved 24 May 2006
Resolution: Observed installation and permanent repair of 3 foot fire main piping located by port side superstructure staircase. Observed test of Fire Main.
Communications › Radio Communications › Emergency Source of Power
Issued 15 May 2006 Resolved
Battery back-up containment box for GMDSS has no means of ventilation.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2006
Resolved 24 May 2006
Resolution: Observed gooseneck ventilation hose installed in battery back-up containment box.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 May 2006 Resolved
Missing Oil Pollution placard in way of OWS. Permanently post the placard.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2006
Resolved 24 May 2006
Resolution: Observed Oil Pollution Placard installed in way of OWS.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 August 2005 Resolved
Vessel's refrigerators (stern, weather deck and in port side crew cabin) are powered via household extension cord. Install proper wiring and terminals to power refrigerators. Provide flag State report attesting to repairs.
Action required: 705 - Other - as specified
Due 29 September 2005
Resolved 13 October 2005
Engineering › Fuel Oil Service System › Piping
Issued 23 August 2005 Resolved
Fuel leak on fuel oil purifier.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2005
Engineering › Fuel Oil Service System › Filter
Issued 23 August 2005 Resolved
Fuel leak on main engine STBD side at the fuel oil filters/collectors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2005
Fire Fighting › Fire Hoses › Condition
Issued 23 August 2005 Resolved
fire hoses have several holes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2005
Resolved 29 August 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 August 2005 Resolved
Fuel shutoffs for the engine room are inoperable. No cables attached.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 23 August 2005 Resolved
Port light glass missing in crew shower
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 23 August 2005 Resolved
Current operating instructions missing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2005
Construction/Loadline › Markings › Load Line Mark
Issued 11 May 2005 Resolved
Loadline markings do not reflect load line certificate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 23 August 2005
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 11 May 2005 Resolved
Provide initial external Document of Compiance audit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 23 August 2005
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 August 2004 Resolved
Hole discovered in bulkhead located in machinery compartment bilge in way of port side sea chest piping. Water intrusion apparent.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2004
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 17 August 2004 Resolved
Numerous wastage in overhead located in machinery compartment. To the satisfaction of a USCG Marine Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 August 2004 Resolved
Missing belt guards for two generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2004
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 17 August 2004 Resolved
Missing Cargo Ships Safety Radio Certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2004
Construction/Loadline › Markings › Load Line Mark
Issued 17 August 2004 Resolved
Properly afix load line markings in accordance with Load Line Certificate. To the satisfaction of a USCG Marine Inspector
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2005
Construction/Loadline › Structures › Manhole
Issued 17 August 2004 Resolved
Chain locker hatch cover is wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2004
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 17 August 2004 Resolved
Improper A/C units in superstructure. All deck vents wasted. To the satisfaction of a USCG Marine Inspector.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 January 2005
Construction/Loadline › Structures › Superstructure
Issued 17 August 2004 Resolved
Properly repair cargo area hatch covers on port and starboard side. Hatch covers are holed and wasted, and have doublers in various locations. To the satisfaction of a USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 September 2004
Resolved 26 January 2005
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 17 August 2004 Resolved
Port side sea chest badly wasted and deteriorated. Crop out old sea chest and install new sea chest. To the satisfaction of a USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 September 2004
Resolved 26 January 2005
Electrical › Electrical Distribution System (service)
Issued 7 January 2004 Resolved
Provide adequate protection for back of switchboard. LEGACY COMPONENT DESC: Switchboard
Condition: Improper Installation
Due 7 February 2004
Resolved 26 March 2004
Resolution: Witnessed installed fences for back portion of the switchboard.
Communications › Alarms/Indicators
Issued 7 January 2004 Resolved
Provide report from flag state attesting to proper installation of bilge alarm and provide test results. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 9 January 2004
Fire Fighting › Fire Main
Issued 7 January 2004 Resolved
Provide report from flag state attesting to the proper installation of the fire main piping and provide test results. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2004
Resolved 9 January 2004
Engineering
Issued 18 July 2003 Resolved
Provide adequate fittings to fuel lines on generators. LEGACY COMPONENT DESC: Generators
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2003
Engineering › Freshwater System (jacketwater cooling)
Issued 18 July 2003 Resolved
Repair freshwater cooling pipe to main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 July 2003
Resolved 24 July 2003
Fire Fighting › Fire Pumps
Issued 18 July 2003 Resolved
Provide cover to rotating parts on both fire pumps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2003
Operations/Management › Equipment Service/Testing
Issued 18 July 2003 Resolved
Provide flag state report to all "prior to departure" items listed on ISM report initiated by captain while underway.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 July 2003
Electrical › Lighting (service)
Issued 5 January 2003 Resolved
Repair/Replace light fixture on starboard side bridge wing. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Damaged By Earlier Event
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected onboard sat.
Stability › Watertight Integrity
Issued 5 January 2003 Resolved
Replace missing gasket on watertight hatch aft of galley.
Due 8 February 2003
Resolved 8 January 2003
Resolution: Corrected on the spot.
Stability › Weathertight Integrity
Issued 5 January 2003 Resolved
Install covers for 2 vents on deck aft of galley.
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 January 2003 Resolved
Replace broken steps on ladder aft, fwd and throughout main deck and above.
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 3 March 2003
Resolution: Corrected during def check inspection.
Navigation › Collision/Grounding Avoidance
Issued 5 January 2003 Resolved
Permanently affix all navigation lights on mast. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Due 18 July 2003
Resolved 18 July 2003
Electrical › Electric Supply System (service)
Issued 5 January 2003 Resolved
Remove all dead end wiring in rooms next to starboard accomodation spaces. LEGACY COMPONENT DESC: Cable
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Lifesaving › Lifebuoys
Issued 5 January 2003 Resolved
Replace all lines on liferings. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Pollution Prevention/Response › Prevention Equipment
Issued 5 January 2003 Resolved
Permanently repair saltwater pipe inway of OWS. Pipe has rubber hose covering a crack. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Due 8 February 2003
Resolved 3 March 2003
Resolution: Corrected during def check inspection.
Engineering › Bilge Water Management System
Issued 5 January 2003 Resolved
Label emergency bilge suction as such. LEGACY COMPONENT DESC: Piping
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Accommodation/Occupational Safety › Potable Water System
Issued 5 January 2003 Resolved
Provide piping for freshwater supply for sink in engine room.
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Fire Fighting › Emergency Fire Pumps
Issued 5 January 2003 Resolved
Make permanent repairs to piping for emergency fire pump. LEGACY COMPONENT DESC: Pressure
Due 8 February 2003
Resolved 3 March 2003
Resolution: Corrected during def check inspection.
Stability › Watertight Integrity
Issued 5 January 2003 Resolved
Replace gasket for hatch cover leading into chain locker.
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Stability › Watertight Integrity
Issued 5 January 2003 Resolved
Replace gasket to fwd cargo hold hatch.
Condition: Improper/Lack of Maintenance
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Navigation › Piloting/Steering
Issued 5 January 2003 Resolved
Update deviation table. Prior to next U.S. port. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 15 - Rectify deficiencies by next port
Resolved 10 February 2003
Resolution: Inspected sat onboard.
Lifesaving › Lifeboat
Issued 5 January 2003 Resolved
Provide SOLAS approved retro-tape on lifeboats. LEGACY COMPONENT DESC: Markings
Due 8 February 2003
Resolved 10 February 2003
Resolution: Inspected sat. onboard.
Electrical › Electrical Distribution System (service)
Issued 17 June 2002 Resolved
Provide rear panels or restrict access to rear of main switchboard. LEGACY COMPONENT DESC: Switchboard
Due 30 June 2002
Resolved 23 July 2002
Resolution: Installed Plexiglass preventor/doors IWO main electrical panel.
Construction/Loadline › Structures
Issued 17 June 2002 Resolved
Replace gasket on Weathertight Door leading to forward Bosun Stores. LEGACY COMPONENT DESC: Door
Due 30 June 2002
Resolved 23 July 2002
Resolution: Gasketing renewed and repairs were made to knife edge IWO lower right corner.
Pollution Prevention/Response › Prevention Equipment
Issued 17 June 2002 Resolved
Repair minor leak on intake line of the Oily Water Seperator. LEGACY COMPONENT DESC: Oily Mixture Discharge Fixed Piping System
Due 30 June 2002
Resolved 23 July 2002
Resolution: No leak was apparent in any part of the OWS piping.
Lifesaving › Lifeboat
Issued 17 June 2002 Resolved
Replace lifelines on both boats to meet SOLAS requirements. LEGACY COMPONENT DESC: Lifeline (becketed)
Due 30 June 2002
Resolved 23 July 2002
Resolution: Renewed all man-lines iwo port and starboard life boats.
Engineering
Issued 13 July 2001 Resolved
Make permanent repairs to starboard side fuel oil tank gooseneck.
Condition: Unknown
Due 13 July 2001
Resolved 18 July 2001
Construction/Loadline
Issued 13 July 2001 Resolved
Provide fasteners for all fittings around cargo hatches prior to next U.S. port call.
Condition: Unknown
Due 13 July 2001
Resolved 18 July 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
HANDRAILS FOWARD AT FOSCLE WERE FRACTURED. REPAIR/RENEW PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Fire Fighting
Issued 7 June 2001 Resolved
EMERGENCY FIRE PUMP DIFFICULT TO START, PRESSURE VERY LOW, TWO HOSE PATCHESON BOTH THE SUCTION AND THE DISCHARGE LINE. REPAIR RENEW PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Electrical
Issued 7 June 2001 Resolved
VESSELS MAIN EMERGENCY SWITCHBOARD AFT SECTION IS NOT SUITABLY GUARDED. PROVIDE ADDITIONAL PROTECTION TO MAKE SWITCHBOARD SUITABLY GUARDED PRIOR TO09JUL01 AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Construction/Loadline
Issued 7 June 2001 Resolved
VESSEL HAS MAJOR HULL DAMAGE ON PORT STERN. MAKE PERMANENT REPAIRS TO HULL AND PROVIDE CLASS REPORT ON REPAIRS PRIOR TO 09JUL01.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Fire Fighting
Issued 7 June 2001 Resolved
VESSEL HAS LEAK ON EMERGENCY FIRE PUMP DISCHARGE PIPING. REPAIR/RENEW PRIORTO 09JUL01 AND PROVIDE CLASS REPORT ON PERMANENT REPAIRS.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
VESSELS SEWAGE HOLDING TANK COVER LOCATED IN AFT SHOWER AREA HAS A HOLE. MAKE PERMANENT REPAIRS TO SEWAGE TANK COVER PRIOR TO 09JUL01 AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Construction/Loadline
Issued 7 June 2001 Resolved
HOLES IN FOSCLE BULKHEAD ON MAINDECK PORT SIDE. REPAIR PROVIDE CLASS REPORTPRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
HOLE IN HATCH COVER TO CHAIN LOCKER. REPAIR AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Documentation
Issued 7 June 2001 Resolved
OIL RECORD BOOK NOT BEING MAINTAINED PROPERLY. LAST ENTRY WAS RECORDED 25MAR01 AND MASTERS SIGNATUR AT THE END OF EACH DAY MISSING FOR ABOUT 5 MONTHS. UPDATE OIL RECORD BOOK AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
HOLE IN FOWARD PORT OF WHEEL HOUSE APPROXIMATELY 4" OFF MAIN DECK STBD. SIDE. REPAIR/RENEW PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Accommodation/Occupational Safety
Issued 7 June 2001 Resolved
HOLE IN [name withheld] PORT LIGHT. REPAIR/RENEW PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Fire Fighting
Issued 7 June 2001 Resolved
OVERDUE INSPECTION DATE ON VESSELS FIXED CO2 SYSTEM BOTTLES. INSPECT SYSTEMPROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Lifesaving
Issued 7 June 2001 Resolved
lIFERAFT HYDRO RELEASE WAS HOOKED UP INCORRECTLY. HOOK UP HYDRO RELEASE PROPERLY PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
CARGO HOLD VENT PORT SIDE MAIN DECK HOLED AND COVERED WITH A SOFT PATCH. REPAIR/ RENEW AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 7 June 2001 Resolved
LEAK IN THE FOREPEAK PORT SIDE BELOW THE WATER LINE. WATER WAS GUSHING OUT.REPAIR/RENEW PROVIDE CLASS REPORT PRIOR TO DEPARTURE OF THE VESSEL.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Fire Fighting
Issued 7 June 2001 Resolved
FIREMAN OUTFIT FLASHLIGHT WAS INOPPERABLE. RENEW/REPLACE BATTERIES.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Electrical
Issued 7 June 2001 Resolved
JACKET WATER EXPANSION CAPS WERE MISSING OFF THE GENERATOR. REPLACE CAPS AND PROVIDE A CLASS REPORT.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Documentation
Issued 7 June 2001 Resolved
NO ANNUAL ENDORSEMENTS ON SOLAS CERTIFICATES. GET CERTIFICATE ENDORSED BY CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Fire Fighting
Issued 7 June 2001 Resolved
PORTABLE FIRE EXTINGUISHER IN ENGINE ROOM LOWER LEVEL WAS NOE INSPECTED. HAVE EXTINGUISHER INSPECTED OR PROVIDE A NEW ONE AND A CLASS REPORT ADDRESSING THE ISSUE PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Engineering
Issued 7 June 2001 Resolved
OILYWATER SEPARATOR INOPPERABLE. REPAIR OWS TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Engineering
Issued 7 June 2001 Resolved
VESSELS UPPER EXPANSION TANK IS NOT BOLTED AT THE FLANGE CAUSING THE EXPANSION TANK TO OVERFLOW. REPAIR/RENEW PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Engineering
Issued 7 June 2001 Resolved
MAIN ENGINE JACKET WATER LEAK BETWEEN # 2 & 3 CYLINDER. REPAIR RENEW PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Electrical
Issued 7 June 2001 Resolved
VESSELS GENERATORS HAVE SEVERAL WORN FLEXIBLE HOSES. REPAPI/RENEW PROVIDE CLASS REPORT AS TO THE SATISFACTION OF THE HOSES FROM CLASS.
Condition: Unknown
Due 7 June 2001
Resolved 11 June 2001
Navigation
Issued 12 March 2001 Resolved
VESSEL ENTERED PORT WITHOUT A PROPERLY OPERATING PRIMARY RADAR. AN LOU WAS REQUESTED AND RECEIVED FOR NOT NOTIFYING THE PROPER AUTHORITIES OF THE MALFUNCTIONING NAVIGATIONAL EQUIPMENT.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Documentation
Issued 19 September 1999 Resolved
OIL TRANSFER PROCEDURES ARE INCOMPLETE.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Lifesaving
Issued 19 September 1999 Resolved
LIFERING LIGHTS ARE INOPERABLE
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Lifesaving
Issued 19 September 1999 Resolved
LIFEBOATS ARE NOT PROPERLY EQUIPPED; MISSING FLARES, COMPASS, LAMP OIL, MATCHES, FLASHLIGHT, JACKNIFE.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Documentation
Issued 19 September 1999 Resolved
CERTIFICATE OF FINANCIAL RESPONSIBILTIY WAS NOT ON BOARD THE VESSEL.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Lifesaving
Issued 19 September 1999 Resolved
LIFEBOATS DID NOT HAVE RETRO REFLECTIVE TAPE INSTALLED.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Navigation
Issued 19 September 1999 Resolved
GYROCOMPASS WAS INOPERABLE. ALTHOUGH NOT REQUIRED BY SOLAS 60, INSTALLED UNIT WAS DEFECTIVE.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Lifesaving
Issued 19 September 1999 Resolved
LIFEBOAT OPERATING INSTRUCTIONS WERE MISSING.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Documentation
Issued 19 September 1999 Resolved
SHIPBOARD OIL POLLUTION EMERGENCY PLAN WAS WRITTEN IN SPANISH. CREW LANGUAGE IS RUSSIAN/UKRANIAN. PLAN MUST BE TRANSLATED INTO EITHER ENGLISH OR CREW LANGUAGE.
Condition: Unknown
Due 21 December 1999
Resolved 21 December 1999
Navigation
Issued 19 September 1999 Resolved
BLOCK AND TACKLE WAS NOT FITTED IN STEERING GEAR ROOM. VESSEL IS ONLY EQUIPPED WITH 1 STEERING PUMP.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Navigation
Issued 19 September 1999 Resolved
RUDDER ANGLE INDICATOR IN WHEELHOUSE WAS INOPERABLE.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999

Ownership record