MAURY USCG vessel records Sign in
← All vessels

ANNA

ANNA is a 1979 offshore supply vessel. The Coast Guard has recorded 63 inspections since 1981, most recently in November 2008, along with 65 deficiencies and 4 casualty investigations between 2002 and 2008.

Records from 1981 to 2008. Most recent: inspection, 24 November 2008.

Built
1979
Last inspected
24 November 2008
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7827201 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB7882
Flag
UNITED STATES
303059000, 338425000, 369242000 (licence lapsed)
Maury page id
psix-50468

Inspections, by type

…with no type recorded22
Years with a record 28 calendar years (1981–2008)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)210.1 ft × 40.0 ft × 16.0 ft
Registered tonnagegross 997 / net 299
ITC dimensions (L × B × D)210.1 ft × 40.0 ft × 16.0 ft
ITC tonnagegross 997 / net 299
BuilderHALTER MARINE INC · LOCKPORT, LA, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCROWN POINT, LA
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it299 - Convention (Subpart B), Net Ton
997 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB7882MMSI 303059000 · expired · compulsorily equipped · granted 18 March 2014, cancelled 20 July 2024
WDB2915MMSI 369242000 · cancelled · compulsorily equipped · granted 10 February 2003, cancelled 30 July 2004
WCW4732MMSI 338425000 · expired · compulsorily equipped · granted 16 September 1998, cancelled 1 July 2006
WCP9789MMSI not assigned · expired · compulsorily equipped · granted 21 February 1995, cancelled 23 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOLIAD Offshore Supply Vessel · MISLE 48942 · 11 January 1998 · activity 102868MARIE G Passenger (Inspected) · MISLE 49694 · 11 January 1998 · activity 102868

Inspection history · 63

24 November 2008 Type not recorded
No type recorded · Activities Europe · Activity 3376715
22 October 2008 Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 3353431
2 October 2008 Type not recorded
No type recorded · Activities Europe · Activity 3377350
19 November 2007 MTSA/ISPS Verification · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 3080223
20 January 2006 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2570236
21 October 2005 Re-Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2513122
11 January 2005 MTSA/ISPS Verification · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2284388
26 January 2004 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1993211
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970998
19 November 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1962484
8 October 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2274107
1 October 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1918462
23 December 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1730453
6 March 2002 Construction Oversight · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494871
27 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772171
29 August 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 821936
29 August 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822351
29 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1054160
10 November 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 807138
10 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812397
4 March 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461109
6 October 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801924
17 September 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803454
11 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102868
11 January 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 216850
17 November 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375173
5 December 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880301
15 October 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434453
15 August 1996 Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1418004
8 August 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1087888
8 August 1996 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1092896
28 December 1995 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363444
26 December 1995 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 142321
25 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 8732
15 August 1995 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446231
29 November 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870275
11 August 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438210
24 March 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166853
25 January 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370770
19 October 1993 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1132254
20 August 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362643
30 August 1991 Re-Inspection · Examination of Repairs · Damage Survey · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248381
21 August 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238249
18 October 1989 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 927631
23 May 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894419
16 May 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342877
14 April 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200893
29 August 1988 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1344805
3 February 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1017866
29 October 1987 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1022053
19 September 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007454
2 September 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005276
6 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996848
15 October 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995883
12 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287919
23 April 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 977243
5 January 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970691
5 January 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970960
26 October 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965707
26 October 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279680
3 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966259
15 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968882
26 October 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277606

Deficiency record · 65

Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 October 2008 Resolved
Provide new or complete hydrostatic test on all five (5) nitrogen activation cylinders for fixed fire extinguishing system. Previous hydro date is 1/2002, date due is in 5 years (1/2007) per the manufacturer servicing manual. Cleared by email dated 11/19/08, will verify during next USCG visit.
Due 22 November 2008
Resolved 17 September 2009
Engineering › Diesel Engine (auxiliary) › Block
Issued 22 October 2008 Resolved
Identify and repair oil leaks to starboard ship service diesel generator. Cleared by email dated 11/19/08, will verify during next USCG visit.
Due 22 November 2008
Resolved 22 October 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 October 2008 Resolved
Clean or replace oil soaked lagging on port main diesel engine exhaust. Cleared by email dated 11/19/08, will verify during next USCG visit.
Due 22 November 2008
Resolved 17 September 2009
Lifesaving › Launching Appliances › Davit
Issued 22 October 2008 Resolved
Provide evidence that rescue boat launching appliance has been serviced per NVIC 4-07.
Due 22 November 2008
Resolved 23 December 2008
Resolution: Item was cleared by email 12/23/08. Rec''d servicing cert and Sea Float servicing authorization letter.
Fire Fighting › Fire Pumps › Pressure
Issued 22 October 2008 Resolved
Determine cause/make repairs to main fire pump. Fire pump operates 2-3 minutes and then shuts down. Emergency fire pump and fire/ballast pump operating normally. Cleared by email from [name withheld] on 30 Oct 08. Fire pump and motor have been replaced, ops checked for 20 minutes. Verification will be made during next USCG attendance.
Due 22 November 2008
Resolved 17 September 2009
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 November 2007 Resolved
Demontrate the proper operation of the emergency lights on the tunnel in way of the life raft stations under black out conditions
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 19 November 2007
Navigation › Piloting/Steering › Chronometer
Issued 19 November 2007 Resolved
Repair the rudder angle indicator so that it reads the true rudder angle at the wheel house and aft steering controls.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 27 November 2007
Lifesaving › Lifebuoys › Stowage
Issued 19 November 2007 Resolved
Demonstrate the proper operation of the quick release function of the port and starboard bridge life wing bouys.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 19 November 2007
Fire Fighting › Portable Foam Applicators › General
Issued 19 November 2007 Resolved
Provide two 4ft. foam applicators as prescribed for by fire control plan.
Condition: Improper/Lack of Maintenance
Due 9 January 2009
Resolved 22 October 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 November 2007 Resolved
Attach line to one ring buoy.
Condition: Improper Installation
Due 23 December 2007
Resolved 24 December 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 November 2007 Resolved
Repair or replace the smoke detector in the laundry.
Condition: Improper/Lack of Maintenance
Due 20 November 2007
Resolved 21 November 2007
Construction/Loadline › Penetrations › Weld
Issued 19 November 2007 Resolved
Weld the holes in the engine room, port and starboard side in way of the emergency exits, closed to A-60 standards.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 19 November 2007
Fire Fighting › Fire Main › Condition
Issued 19 November 2007 Resolved
Crop and renew the holed fire main.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 19 November 2007
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 19 November 2007 Resolved
Repair all ouside dampers on the funnels and house so that they close tightly and quickly.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 19 November 2007
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 19 November 2007 Resolved
Label inside damper shut-offs and demonstrate their operation.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 22 November 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 November 2007 Resolved
Calibrate the compass
Condition: Improper/Lack of Maintenance
Due 9 January 2009
Resolved 22 October 2008
Electrical › Electric Supply System (service) › Cable
Issued 19 November 2007 Resolved
Remove all dead end wiring on the flying bridge and the wheel house.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Communications › Radio Communications › Satellite Communications Capability
Issued 19 November 2007 Resolved
Demonstrate proper operation of the GMDSS, including the DSC receiver.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 November 2007 Resolved
Renew battery for the emergency light in steering passageway.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 November 2007 Resolved
Prove proper operation of all automatic door closures in engine space.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Electrical › Lighting (service) › Lighting Feeder
Issued 19 November 2007 Resolved
Prove proper operation of light fixture above port main engine.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Engineering › Bilge Water Management System › Strainer
Issued 19 November 2007 Resolved
Provide strainers for all bilge suctions.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 November 2007 Resolved
Properly install cover on breaker panel in bow thruster space.
Condition: Improper Installation
Due 19 November 2007
Resolved 20 November 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 November 2007 Resolved
Properly install bilge alarm in passageway.
Condition: Improper Installation
Due 19 November 2007
Resolved 20 November 2007
Engineering › Fuel Oil Service System › Valve, Control
Issued 19 November 2007 Resolved
Properly label emergency fuel shutoff.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Engineering › Fuel Oil Service System › Valve, Control
Issued 19 November 2007 Resolved
Provide T-handle for emergency fuel shutoffs.
Condition: Improper Installation
Due 19 November 2007
Resolved 20 November 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 19 November 2007 Resolved
Clean up the lint from behing the dryer and inside the hose.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007 Resolved
Replace the #3 port aft ballast thank hatch cover.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Cargo Stowage › General
Issued 19 November 2007 Resolved
Renew the hatch cover flanges #2 port and starboard liquid mud tanks.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007 Resolved
Crop and renew painted inset in the #2 starboard ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007 Resolved
V gouge the painted fractured weld in the #2 starboard ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007 Resolved
Crop and renew two inserts in the #2 port ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007 Resolved
V and gouge two fracture in the #2 port ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 November 2007 Resolved
Install guards over all moving machinery.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 19 November 2007 Resolved
Place a copy of the automation test procedures on board.
Due 19 November 2007
Resolved 20 November 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 November 2007 Resolved
Properly repair all fractures in way of the main engine exaust were it penetrates the forward machinery bulkhead.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 19 November 2007 Resolved
Provide electrical mating in front of all switchboard panels.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Operations/Management › Drills/Instruction › Fire
Issued 19 November 2007 Resolved
Conduct a satisfactory fire and boat drill in the presence of a Marine inspector.
Due 25 December 2007
Resolved 27 November 2007
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 19 November 2007 Resolved
Make connection between the SCBA and regulator seal tightly.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 19 November 2007 Resolved
Prove proper operation of port generator shut-down safety devices.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 27 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 19 November 2007 Resolved
Prove proper operation of the bridge windshield wipers.
Condition: Damaged By Earlier Event
Due 25 December 2007
Resolved 27 November 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 19 November 2007 Resolved
Demonstrate the proper operation of the upper and lower running lights and mast lights.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 19 November 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 November 2007 Resolved
Install emergency lighting in the cargo tank passageway.
Due 19 November 2007
Resolved 20 November 2007
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 19 November 2007 Resolved
Relace or properly repair the flywheel so that all teeth can engage the starter gear.
Condition: Damaged By Earlier Event
Due 25 December 2007
Resolved 27 November 2007
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 November 2007 Resolved
Provide an approved copy of the automated test procedures on board.
Due 30 January 2008
Resolved 22 January 2008
Resolution: Procedures reveiwed and approved locally.
Electrical › Electric Supply System (service) › Cable
Issued 19 November 2007 Resolved
Demonstrate proper operation of the main engines bridge tachometers
Due 9 January 2009
Resolved 22 October 2008
Engineering › Electric Propulsion System › Battery
Issued 19 November 2007 Resolved
Provide proper battery box for SSDG
Due 27 December 2007
Resolved 26 December 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 November 2007 Resolved
Make repairs to E/R aft W.T.D. closing mechanism.
Due 27 December 2007
Resolved 27 November 2007
Communications › Internal Communications System › Sound-powered Telephone
Issued 19 November 2007 Resolved
Provide adiquate communications at the sound powered phone station in the engineroom
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 22 October 2008
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 19 November 2007 Resolved
Provide flame impingment bowls on all f/o filters.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 22 October 2008
Stability › Watertight Integrity › General
Issued 11 January 2005 Resolved
Crew disabled watertight door indicators intentionally. Stated that they did not work properly. Tidewater stated that they have a 60 second time delay. Tidewater is to provide approved plans to the OCMI in Morgan City, showing operation of the indicators.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 21 October 2005
Resolution: Watertight door indicators work properly and current crew has not disabled them as before. Deficiency cleared.
Lifesaving
Issued 4 March 1999 Resolved
PROVIDE SUITABLE RESCUE BOAT IAW DISTRICT EIGHT POLICT LETTER 16613 DATED 12NOV98.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Documentation
Issued 16 May 1989 Resolved
PLACE ON BOARD VESSEL CURRENT EDITION OF LAWS GOVERNING MARINE, INSPECTION,COAST PILOT, TIDE TABLE, CURRENT TABLE AND LIGHT LIST.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Documentation
Issued 16 May 1989 Resolved
PLACE ON BOARD VESSEL CARGO RECORD BOOK AS PER 46 CFR 98.31-10.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 29 October 1987 Resolved
REPAIR PORT SHAFT TACHOMETER.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Unknown
Issued 29 October 1987 Resolved
INSTALL RELIEF VALVE OF THR PROPER SIZE BETWEEN THE AIR COMPRESSOR AND FIRST CUT-OUT VALVE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Deck/Cargo
Issued 29 October 1987 Resolved
INSTALL A CHAIN AND LOCK ON THE SEWAGE OVERBOARD DISCHARGE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987 Resolved
FREE DOGS ON THE PORT AND STARBOARD ESCAPE HATCHES FROM THE ENGINE ROOM.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Electrical
Issued 29 October 1987 Resolved
PROVIDE EMERGENCY LIGHTING FOR THE S/S GENERATOR SWITCHBOARD.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Navigation
Issued 29 October 1987 Resolved
REPAIR #2 STEERING PUMP POWER FAILURE ALARM, INCLUDING INDICATOR LIGHTS AS NEEDED.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Engineering
Issued 2 September 1986 Resolved
REPAIR RUDDER ANGLE INDICATOR IN ENGINEROOM.
Condition: Unknown
Due 2 September 1986
Resolved 2 September 1986
Engineering
Issued 2 September 1986 Resolved
REPAIR SHAFT TACHS ON BRIDGE.
Condition: Unknown
Due 2 September 1986
Resolved 2 September 1986
Construction/Loadline
Issued 5 January 1984 Resolved
PLACE T-HANDLE WRENCH ONBOARD FOR OPERATION OF THE FOREPEAK TANK BILGE SUCTION VALVE AND MOUNT SAID WRENCH IN VICINITY OF SAID VALVE.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 26 October 1983 Resolved
INSTALL GUARDS OVER OILER BELT DRIVES ON BOTH GENERATORS.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983
Documentation
Issued 26 October 1983 Resolved
PROVIDE A VALID FEDERAL MARITIME COMMISSION CERTIFICATE ONBOARD VESSEL.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983

Casualty record · 4

23 December 2002Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1730453
26 November 2006Routine · role: Involved in a Marine Casualty · activity 2832259
2 October 2008Routine · role: Subject to Marine Inspection · activity 3377350
24 November 2008Routine · role: Subject to Marine Inspection · activity 3376715
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 2

WHIRLAWAY (2002), STANNARD TIDE (2006–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.