Records from 1981 to 2008. Most recent: inspection, 24 November 2008.
Inspection history · 63
24 November 2008
Type not recorded
No type recorded · Activities Europe · Activity 3376715
22 October 2008
Deficiency Check · Annual Inspection
Physical examination · Activities Europe · Activity 3353431
2 October 2008
Type not recorded
No type recorded · Activities Europe · Activity 3377350
19 November 2007
MTSA/ISPS Verification · Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 3080223
20 January 2006
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2570236
21 October 2005
Re-Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2513122
11 January 2005
MTSA/ISPS Verification · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2284388
26 January 2004
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1993211
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970998
19 November 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1962484
8 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2274107
1 October 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1918462
23 December 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1730453
6 March 2002
Construction Oversight · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494871
27 November 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772171
29 August 2000
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 821936
29 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 822351
29 August 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1054160
10 November 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 807138
10 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812397
4 March 1999
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461109
6 October 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801924
17 September 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803454
11 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102868
11 January 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 216850
17 November 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375173
5 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880301
15 October 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434453
15 August 1996
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1418004
8 August 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1087888
8 August 1996
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1092896
28 December 1995
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363444
26 December 1995
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 142321
25 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 8732
15 August 1995
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446231
29 November 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 870275
11 August 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438210
24 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166853
25 January 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370770
19 October 1993
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1132254
20 August 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362643
30 August 1991
Re-Inspection · Examination of Repairs · Damage Survey · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248381
21 August 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238249
18 October 1989
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 927631
23 May 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894419
16 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342877
14 April 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200893
29 August 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1344805
3 February 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1017866
29 October 1987
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1022053
19 September 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007454
2 September 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005276
6 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996848
15 October 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995883
12 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287919
23 April 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 977243
5 January 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970691
5 January 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970960
26 October 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965707
26 October 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279680
3 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966259
15 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968882
26 October 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277606
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 October 2008
Resolved
Provide new or complete hydrostatic test on all five (5) nitrogen activation cylinders for fixed fire extinguishing system. Previous hydro date is 1/2002, date due is in 5 years (1/2007) per the manufacturer servicing manual. Cleared by email dated 11/19/08, will verify during next USCG visit.
Due 22 November 2008
Resolved 17 September 2009
Engineering › Diesel Engine (auxiliary) › Block
Issued 22 October 2008
Resolved
Identify and repair oil leaks to starboard ship service diesel generator. Cleared by email dated 11/19/08, will verify during next USCG visit.
Due 22 November 2008
Resolved 22 October 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 October 2008
Resolved
Clean or replace oil soaked lagging on port main diesel engine exhaust. Cleared by email dated 11/19/08, will verify during next USCG visit.
Due 22 November 2008
Resolved 17 September 2009
Lifesaving › Launching Appliances › Davit
Issued 22 October 2008
Resolved
Provide evidence that rescue boat launching appliance has been serviced per NVIC 4-07.
Due 22 November 2008
Resolved 23 December 2008
Resolution: Item was cleared by email 12/23/08. Rec''d servicing cert and Sea Float servicing authorization letter.
Fire Fighting › Fire Pumps › Pressure
Issued 22 October 2008
Resolved
Determine cause/make repairs to main fire pump. Fire pump operates 2-3 minutes and then shuts down. Emergency fire pump and fire/ballast pump operating normally. Cleared by email from [name withheld] on 30 Oct 08. Fire pump and motor have been replaced, ops checked for 20 minutes. Verification will be made during next USCG attendance.
Due 22 November 2008
Resolved 17 September 2009
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 November 2007
Resolved
Demontrate the proper operation of the emergency lights on the tunnel in way of the life raft stations under black out conditions
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 19 November 2007
Navigation › Piloting/Steering › Chronometer
Issued 19 November 2007
Resolved
Repair the rudder angle indicator so that it reads the true rudder angle at the wheel house and aft steering controls.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 27 November 2007
Lifesaving › Lifebuoys › Stowage
Issued 19 November 2007
Resolved
Demonstrate the proper operation of the quick release function of the port and starboard bridge life wing bouys.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 19 November 2007
Fire Fighting › Portable Foam Applicators › General
Issued 19 November 2007
Resolved
Provide two 4ft. foam applicators as prescribed for by fire control plan.
Condition: Improper/Lack of Maintenance
Due 9 January 2009
Resolved 22 October 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 November 2007
Resolved
Attach line to one ring buoy.
Condition: Improper Installation
Due 23 December 2007
Resolved 24 December 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 November 2007
Resolved
Repair or replace the smoke detector in the laundry.
Condition: Improper/Lack of Maintenance
Due 20 November 2007
Resolved 21 November 2007
Construction/Loadline › Penetrations › Weld
Issued 19 November 2007
Resolved
Weld the holes in the engine room, port and starboard side in way of the emergency exits, closed to A-60 standards.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 19 November 2007
Fire Fighting › Fire Main › Condition
Issued 19 November 2007
Resolved
Crop and renew the holed fire main.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 19 November 2007
Fire Fighting › Structural Fire Protection - General › Deckhouse Construction
Issued 19 November 2007
Resolved
Repair all ouside dampers on the funnels and house so that they close tightly and quickly.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 19 November 2007
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 19 November 2007
Resolved
Label inside damper shut-offs and demonstrate their operation.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 22 November 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 November 2007
Resolved
Calibrate the compass
Condition: Improper/Lack of Maintenance
Due 9 January 2009
Resolved 22 October 2008
Electrical › Electric Supply System (service) › Cable
Issued 19 November 2007
Resolved
Remove all dead end wiring on the flying bridge and the wheel house.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Communications › Radio Communications › Satellite Communications Capability
Issued 19 November 2007
Resolved
Demonstrate proper operation of the GMDSS, including the DSC receiver.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 November 2007
Resolved
Renew battery for the emergency light in steering passageway.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 November 2007
Resolved
Prove proper operation of all automatic door closures in engine space.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Electrical › Lighting (service) › Lighting Feeder
Issued 19 November 2007
Resolved
Prove proper operation of light fixture above port main engine.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Engineering › Bilge Water Management System › Strainer
Issued 19 November 2007
Resolved
Provide strainers for all bilge suctions.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 19 November 2007
Resolved
Properly install cover on breaker panel in bow thruster space.
Condition: Improper Installation
Due 19 November 2007
Resolved 20 November 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 November 2007
Resolved
Properly install bilge alarm in passageway.
Condition: Improper Installation
Due 19 November 2007
Resolved 20 November 2007
Engineering › Fuel Oil Service System › Valve, Control
Issued 19 November 2007
Resolved
Properly label emergency fuel shutoff.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Engineering › Fuel Oil Service System › Valve, Control
Issued 19 November 2007
Resolved
Provide T-handle for emergency fuel shutoffs.
Condition: Improper Installation
Due 19 November 2007
Resolved 20 November 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 19 November 2007
Resolved
Clean up the lint from behing the dryer and inside the hose.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007
Resolved
Replace the #3 port aft ballast thank hatch cover.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Cargo Stowage › General
Issued 19 November 2007
Resolved
Renew the hatch cover flanges #2 port and starboard liquid mud tanks.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007
Resolved
Crop and renew painted inset in the #2 starboard ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007
Resolved
V gouge the painted fractured weld in the #2 starboard ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007
Resolved
Crop and renew two inserts in the #2 port ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Deck/Cargo › Ballast › Tank
Issued 19 November 2007
Resolved
V and gouge two fracture in the #2 port ballast tank.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 November 2007
Resolved
Install guards over all moving machinery.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 19 November 2007
Resolved
Place a copy of the automation test procedures on board.
Due 19 November 2007
Resolved 20 November 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 November 2007
Resolved
Properly repair all fractures in way of the main engine exaust were it penetrates the forward machinery bulkhead.
Condition: Damaged By Earlier Event
Due 19 November 2007
Resolved 20 November 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 19 November 2007
Resolved
Provide electrical mating in front of all switchboard panels.
Condition: Improper Installation
Due 25 December 2007
Resolved 27 November 2007
Operations/Management › Drills/Instruction › Fire
Issued 19 November 2007
Resolved
Conduct a satisfactory fire and boat drill in the presence of a Marine inspector.
Due 25 December 2007
Resolved 27 November 2007
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 19 November 2007
Resolved
Make connection between the SCBA and regulator seal tightly.
Condition: Improper/Lack of Maintenance
Due 19 November 2007
Resolved 20 November 2007
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 19 November 2007
Resolved
Prove proper operation of port generator shut-down safety devices.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 27 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 19 November 2007
Resolved
Prove proper operation of the bridge windshield wipers.
Condition: Damaged By Earlier Event
Due 25 December 2007
Resolved 27 November 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 19 November 2007
Resolved
Demonstrate the proper operation of the upper and lower running lights and mast lights.
Condition: Improper/Lack of Maintenance
Due 25 December 2007
Resolved 19 November 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 19 November 2007
Resolved
Install emergency lighting in the cargo tank passageway.
Due 19 November 2007
Resolved 20 November 2007
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 19 November 2007
Resolved
Relace or properly repair the flywheel so that all teeth can engage the starter gear.
Condition: Damaged By Earlier Event
Due 25 December 2007
Resolved 27 November 2007
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 November 2007
Resolved
Provide an approved copy of the automated test procedures on board.
Due 30 January 2008
Resolved 22 January 2008
Resolution: Procedures reveiwed and approved locally.
Electrical › Electric Supply System (service) › Cable
Issued 19 November 2007
Resolved
Demonstrate proper operation of the main engines bridge tachometers
Due 9 January 2009
Resolved 22 October 2008
Engineering › Electric Propulsion System › Battery
Issued 19 November 2007
Resolved
Provide proper battery box for SSDG
Due 27 December 2007
Resolved 26 December 2007
Construction/Loadline › Structures › Machinery Space Opening
Issued 19 November 2007
Resolved
Make repairs to E/R aft W.T.D. closing mechanism.
Due 27 December 2007
Resolved 27 November 2007
Communications › Internal Communications System › Sound-powered Telephone
Issued 19 November 2007
Resolved
Provide adiquate communications at the sound powered phone station in the engineroom
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 22 October 2008
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 19 November 2007
Resolved
Provide flame impingment bowls on all f/o filters.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 22 October 2008
Stability › Watertight Integrity › General
Issued 11 January 2005
Resolved
Crew disabled watertight door indicators intentionally. Stated that they did not work properly. Tidewater stated that they have a 60 second time delay. Tidewater is to provide approved plans to the OCMI in Morgan City, showing operation of the indicators.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 May 2005
Resolved 21 October 2005
Resolution: Watertight door indicators work properly and current crew has not disabled them as before. Deficiency cleared.
Lifesaving
Issued 4 March 1999
Resolved
PROVIDE SUITABLE RESCUE BOAT IAW DISTRICT EIGHT POLICT LETTER 16613 DATED 12NOV98.
Condition: Unknown
Due 4 March 1999
Resolved 4 March 1999
Documentation
Issued 16 May 1989
Resolved
PLACE ON BOARD VESSEL CURRENT EDITION OF LAWS GOVERNING MARINE, INSPECTION,COAST PILOT, TIDE TABLE, CURRENT TABLE AND LIGHT LIST.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Documentation
Issued 16 May 1989
Resolved
PLACE ON BOARD VESSEL CARGO RECORD BOOK AS PER 46 CFR 98.31-10.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Engineering
Issued 29 October 1987
Resolved
REPAIR PORT SHAFT TACHOMETER.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Unknown
Issued 29 October 1987
Resolved
INSTALL RELIEF VALVE OF THR PROPER SIZE BETWEEN THE AIR COMPRESSOR AND FIRST CUT-OUT VALVE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Deck/Cargo
Issued 29 October 1987
Resolved
INSTALL A CHAIN AND LOCK ON THE SEWAGE OVERBOARD DISCHARGE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987
Resolved
FREE DOGS ON THE PORT AND STARBOARD ESCAPE HATCHES FROM THE ENGINE ROOM.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Electrical
Issued 29 October 1987
Resolved
PROVIDE EMERGENCY LIGHTING FOR THE S/S GENERATOR SWITCHBOARD.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Navigation
Issued 29 October 1987
Resolved
REPAIR #2 STEERING PUMP POWER FAILURE ALARM, INCLUDING INDICATOR LIGHTS AS NEEDED.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Engineering
Issued 2 September 1986
Resolved
REPAIR RUDDER ANGLE INDICATOR IN ENGINEROOM.
Condition: Unknown
Due 2 September 1986
Resolved 2 September 1986
Engineering
Issued 2 September 1986
Resolved
REPAIR SHAFT TACHS ON BRIDGE.
Condition: Unknown
Due 2 September 1986
Resolved 2 September 1986
Construction/Loadline
Issued 5 January 1984
Resolved
PLACE T-HANDLE WRENCH ONBOARD FOR OPERATION OF THE FOREPEAK TANK BILGE SUCTION VALVE AND MOUNT SAID WRENCH IN VICINITY OF SAID VALVE.
Condition: Unknown
Due 5 January 1984
Resolved 5 January 1984
Unknown
Issued 26 October 1983
Resolved
INSTALL GUARDS OVER OILER BELT DRIVES ON BOTH GENERATORS.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983
Documentation
Issued 26 October 1983
Resolved
PROVIDE A VALID FEDERAL MARITIME COMMISSION CERTIFICATE ONBOARD VESSEL.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983