ADMIRALTY DREAM

ADMIRALTY DREAM is a 1979 passenger vessel (inspected). The Coast Guard has recorded 49 inspections since 2016, most recently in March 2026, along with 84 deficiencies — 1 with no resolution recorded — and 13 casualty investigations between 2003 and 2025.

Records from 2003 to 2026. Most recent: inspection, 17 March 2026.

Built
1979
Last inspected
17 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8963727
WDF7628
Flag
UNITED STATES
Maury page id
psix-50478

Documentation record

Registered dimensions (L × B × D)122.2 ft × 28.0 ft × 9.7 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)122.2 ft × 28.0 ft × 9.7 ft
ITC tonnagegross 514 / net 154
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSITKA, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 31 December 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
514 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
154 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

49 inspections, each with its date, unit and type; 84 deficiencies with the resolution recorded against each; 1 other recorded name, with years; 13 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 49

17 March 2026 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8328404
2 September 2025 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8225694
9 August 2025 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8207640
16 July 2025 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8193181
12 June 2025 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8158412
29 May 2025 In-Service Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8152427
25 May 2025 Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8144001
25 May 2025 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8172571
12 May 2025 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8133666
7 October 2024 Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8016165
10 August 2024 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7978372
20 June 2024 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7940105
13 May 2024 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7911695
17 November 2023 Administrative Inspection · Special Consideration · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7836740
19 September 2023 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7793968
29 June 2023 Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7729103
20 June 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7726822
29 May 2023 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7699728
10 May 2023 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7685347
29 November 2022 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7600856
19 September 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7566263
7 August 2022 In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7524877
17 May 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7453223
26 April 2022 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7438204
21 April 2022 Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7438041
29 September 2021 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7353730
18 September 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7316481
13 May 2021 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7195607
30 November 2020 Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7103912
16 November 2020 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7096509
7 April 2020 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6936646
10 December 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6870264
1 October 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6826901
7 May 2019 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6683290
28 March 2019 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6651707
9 February 2019 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6628581
8 November 2018 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6578430
9 October 2018 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6558841
25 September 2018 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6548333
23 March 2018 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6379010
6 March 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6367698
21 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6358739
1 November 2017 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6299179
11 October 2017 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6286702
6 March 2017 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6102681
2 November 2016 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6031412
12 October 2016 In-Service Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6021413
15 September 2016 Damage Survey · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6002297
10 May 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5874402

Deficiency record · 84

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 September 2025 No resolution recorded
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding it designed limitations. Vessel representative reported port main engine fuel pump failure. Vessel is required to repair/replace fuel pump and demonstrate proper operation of the the port main engine to the satisfaction of Marine Inspector prior to the operations of the vessel with passenger or cargo. Passenger may remain on board while vessel is moored. 46 CFR 182.05-1 (a)
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 August 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions and Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Emergency light in engine room had a broken lamp head and was dangling by the wires. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2025
Resolved 18 August 2025
Resolution: Emergency light in engine room was replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2025 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Dead end wires with wire nuts was found next to the over head emergency light in the medical stairwell. 46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2025
Resolved 18 August 2025
Resolution: Dead end wire was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 August 2025 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. Light in galley in front of reefers was missing the bulbs and cover which exposed the energized component of the fixture. 46 CFR 183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2025
Resolved 18 August 2025
Resolution: Light and cover were replaced in kind.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 August 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Blank in electrical panel 6 located in engineering passageway was missing. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2025
Resolved 18 August 2025
Resolution: Blank was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 May 2025 Resolved
marine load under such requirements without exceeding its designed limitations. O/O reported loss of stbd propulsion. Vessel is not able to generate thrust, indicating a possible loss of propeller. Investigate to determine cause and complete final repairs. After disembarking passengers at a safe location, no passengers are to be carried, to include transit to port with repair capabilities, until satisfactory repairs are completed and verified by a Marine Inspector. 46CFR182.200
Action required: 705 - Other - as specified
Resolved 30 May 2025
Resolution: 4 blade prop was installed ont he starboard shaft and underway OPTEST sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 12 May 2025 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Port aft 300 deck CO2 activated fire damper has not been serviced. 46 CFR 176.810(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: Fire dampers serviced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 May 2025 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment.Inspection and testing of all smoke and fire detection systems, including sensors and alarms. 46 CFR 177.810(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: Serviced. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to:(a) Provide services necessary for safety under normal and emergency conditions;(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;(c) Minimize accidental personnel contact with energized parts. The following issues were identified: -Electrical enclosure in crew RM101 not secured properly - Electrical enclosure in overhead of FWD 100's RM101 is missing the cover - Light fixture in room 107 is hanging from overhead with exposed wires. - Port Aft passenger room (Yakobi) vanity light is hanging off the bulkhead with exposed wires - Reefer room overhead light was not properly secured. Was found zip tied to the overhead frame. - Light in above engineering work bench is missing the protective cover. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: All identified electrical issues were resolved SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 May 2025 Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. Forward lounge space emergency escape scuttle did not open freely. 46 CFR 177.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: Opens freely. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 12 May 2025 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant OCMI. 46 CFR 185.606
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: New sign. All sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 May 2025 Resolved
Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered automatically operated lights in strategic locations. Engineering passageway emergency light was not properly secured to the bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: Emergency light runs off e-gen. All sat.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 May 2025 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Room 109 PA speaker was not properly secured and was found lying on the bed. 46 CFR 184.610(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: Remounted. All sat
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 12 May 2025 Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595, or shall bear the proper Underwriters' Laboratories, Inc. "Marine Type" label, or shall be constructed in accordance with the requirements of other recognized testing laboratories. Several main deck exterior lights were missing the protective guard around the globe and were full of water. 46 CFR 183.10-20(I)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: Protective guards added. All sat
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 12 May 2025 Resolved
At each inspection for certification and at every other vessel inspection galleys may be examined to determine that they are serviceable and sanitary. Galley range hood fan and exhaust vent was found with excessive grease. 46 CFR 176.818
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2025
Resolution: Vent cleaned. All sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port engine is overheating due to unknown causes at this time. Make repairs and determine cause. 46CFR182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2024
Resolution: New port engine block installed and optested sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2024 Resolved
46 CFR 176.810(a)(1)On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. 46 CFR 181.300(b)
Action required: 705 - Other - as specified
Resolved 14 May 2024
Resolution: Pump throttle was adjusted and subsequent testing achieved 60psi at the pump gauge.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. 02 fire extinguishers were found past due on its inspection. 46 CFR 176.810(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: 02 fire extinguishers were serviced.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 13 May 2024 Resolved
Combustibles and other foreign materials are not allowed within ventilation ducts. Galley griddle exhaust ventilation had excessive build up of grease. 46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Ventilation fans and duct were degreased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Emergency diesel generator CO2 bottle was past its required servicing date. 46 CFR 176.810(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2024
Resolution: EDG CO2 bottle was replaced in kind with one that had been serviced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 May 2024 Resolved
An interconnected detection and alarm system must e installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. New system was installed and initial testing did not activate all alarms as required. 46 CFR 181.450(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: O/O identified the issue and it was corrected. Additional testing activated all alarms as designed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2024 Resolved
A space containing diesel machinery must be fitted with at least two ducts to furnish natural or powered supply and exhaust ventilation. Aft engine room powered ventilation was not functioning properly. 46 CFR 182.465(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: Inoperable fan was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 13 May 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. ENC charts were out of date. 46 CFR 184.420(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2024
Resolution: ENC charts were updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. After repairs are complete on the starboard side generator, complete operational test to the satisfaction of a Coast Guard Marine Inspector. 46 CFR 176.840
Action required: 705 - Other - as specified
Resolved 10 August 2024
Resolution: Starboard side generator was repaired and gen set was reinstalled. Optest sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 19 September 2023 Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Monthly EPIRB testing logs could not be located. 46 CFR 185.728(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: EPIRB tests were logged apropriately.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 September 2023 Resolved
A weathertight door must be provided for each opening located in a deck house or companionway. Several companionway sliding doors on the 300 deck cabin level did not close properly and were not weathertight. 46 CFR 179.360(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: Doors were adjusted and were found weathertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 September 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MSD raw water pump had been removed in the MSD space and the wires were found exposed. 46 CFR 183.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: MSD raw water pump was reinstalled and wires were contained in the enclosure.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 19 September 2023 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03–2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Alcohol testing device onboard was not calibrated this year and alcohol swabs were not located onboard. 46 CFR 185.212
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: Alcohol testing device was onboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 May 2023 Resolved
A self priming, power driven fire pump must be installed on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. Vessels fire pump was not able to achieve 60 psi at the pump outlet. 46 CFR 181.300(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2023
Resolution: Fire pump was tested sat @ 60 psi.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. HVAC electrical panel in the starboard side bridge crawl space was missing the panel cover. 46 CFR 183.200
Action required: 10 - Deficiency Rectified
Resolved 19 September 2022
Resolution: Electrical panel cover was reinstalled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 September 2022 Resolved
Receptacle outlets and attachment plugs for portable lamps, tools, and similar apparatus operating at 100 volts or more, must have a grounding pole and a grounding conductor in the portable cord. Several portable fans and portable heaters that operated in excess of 100 volts that did not have a grounding pole were found throughout the vessel. 46 CFR 183.370(b)
Action required: 10 - Deficiency Rectified
Resolved 19 September 2022
Resolution: Portable equipment was removed from the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 April 2022 Resolved
A vessel of more than 19.8 meters (65 feet) in length must have at least one fire axe located in or adjacent to the primary operating station. Vessel had numerous fire axes throughout the vessel but none were located in or adjacent to the primary operating station. 46 CFR 181.35-1 (Old T)
Action required: 10 - Deficiency Rectified
Due 26 April 2022
Resolved 26 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 April 2022 Resolved
The means provided for pumping bilges shall be tested by operation. All suctionj strainers shall be examined. Forward 100's bilge suction strainer was corroded and clogged. 46 CFR 176.25-1(7) - Old T
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2022
Resolved 6 May 2022
Resolution: Bilge screen was replaced new and operable.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 June 2021 Resolved
Found firedoor in forward 100's did not satisfactorily close.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2021
Resolution: Fire door operation was found satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2021 Resolved
Found dead end wire above air receiver in engine room. Wire needs to be corrected or removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 9 June 2021
Resolution: Dead end wire was removed from vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 3 June 2021 Resolved
Found grey water tank hatch cover removed. Secure hatch cover.
Action required: 10 - Deficiency Rectified
Resolved 3 June 2021
Resolution: Hatch was secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 June 2021 Resolved
Found compressor cover contactor switch missing. Replace cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
Resolution: Compressor cover was found replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 June 2021 Resolved
Found dead end wire above bow thruster engine in the overhead.
Action required: 10 - Deficiency Rectified
Resolved 3 June 2021
Resolution: Dead end wire was removed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 13 May 2021 Resolved
Properly inspect portable fire extinguisher in fwd lounge all the way fwd.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Fire extinguisher was found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2021 Resolved
Prove proper operation of machinery shutdowns for fixed CO2 system.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 10 June 2021
Resolution: Witnessed satisfactory operation of CO2 machinery shutdown at idle.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2021 Resolved
Provide appropriate lanyard for water light for ring buoy, fwd port deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: RLB was found satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 13 May 2021 Resolved
Grind out cracked weld on stbd aft deck railing base and re-weld.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Cracked weld on deck railing was repaired and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 13 May 2021 Resolved
Prove proper operation of ventilation shutdown adjacent to Chichagof cabin.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Observed satisfactory operation of ventilation shutdown.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2021 Resolved
Prove proper operation of emergency lighting in FWD 100s, Engine Room, deck 1 hall and the flickering leds in fwd lounge.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Observed satisfactory emergency lighting in FWD 100s, engine room, and deck 1.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 May 2021 Resolved
Provide current FCC ships station license.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: FFC SSL was found satisfractory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2021 Resolved
Provide proof of enrollment and preemployment drug testing for entire crew.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Proof of enrollment and pre-employment testing was found satisfactory.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2021 Resolved
Remove trip hazard on top step of deck 3 fwd stairwell.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Trip hazard was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2021 Resolved
Replace deck 2 furnace bottom cover.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Deck 2 furnace cover was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2021 Resolved
Remove or permanently secure blue fan in furnace space.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Fan was removed from furnace space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2021 Resolved
Correct fwd deck 1 fire doors into lounge from rubbing lighting fixture.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2021
Resolved 3 June 2021
Resolution: Lighting fixture was moved and operation of fire door was found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 13 May 2021 Resolved
Replace missing structural fire protection in engine room overhead along aft bulkhead, above stbd gen and stbd MDE.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2021
Resolved 3 June 2021
Resolution: Missing structural fire protection was found satisfactorily replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 May 2021 Resolved
Provide appropriate gasket seal for fwd bow door.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Gasket was replaced and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 May 2021 Resolved
Remove or provide means of keeping deadbolt locks from preventing fire doors from automatically closing.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Observed satisfactory operation of fire doors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2021 Resolved
Properly mount doors on E/R fixed extinguisher CO2 cabinets.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Doors were found satisfactorily mounted.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 13 May 2021 Resolved
Provide international shore connection iaw. approved fire control plan.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 9 June 2021
Resolution: international shore connection was installed with new gaskets and bolts and was found satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2021 Resolved
Replace missing cover on 12v battery charger for emergency generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Cover was found replaced on 12v battery.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2021 Resolved
Repair or properly terminate dangling wires below 12v battery charger for emergency generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Wires were found satisfactorily repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2021 Resolved
Replace missing exhaust pipe lagging on stbd generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Lagging was replaced on stbd generator.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 May 2021 Resolved
Replace missing bolts on stbd generator cover.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Missing bolts were found replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2021 Resolved
Prove proper operation of safety relief valve on engine room air receiver.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 9 June 2021
Resolution: New relief valve was installed. Witnessed satisfactory operation of relief valve under the MAWP of air receiver.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2021 Resolved
Make lower 100s available for inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2021
Resolved 3 June 2021
Resolution: Conducted walktrough of lower 100s and issued 5 CG-835s.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 March 2021 Resolved
Prove proper operation of automatic shut downs for port side generator and fixed fire extinguishing system.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 March 2021
Resolved 10 June 2021
Resolution: After failed shutdown on 9JUN21, vessel crew rebuilt intake dampner on Port generator with new springs and gasket. Witnessed satisfactory CO2 shutdown while generator was rated without load.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 November 2020 Resolved
Replace weather-tight seals on aft door and port side water tight doors. Item to be cleared prior to receiving credit for dry dock inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 January 2021
Resolved 19 May 2021
Resolution: Seal replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 April 2020 Resolved
While the vessel is engaged in towing the vessel must be controlled by a licensed Master or Mate of towing. Vessel has until April 1st 2022 to man vessel with licensed Master and Mate of towing.
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 29 September 2021
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 7 April 2020 Resolved
Vessel must provide updated stability calculations to include towing to Coast Guard Marine Safety Center to update vessels stability letter by April 1st 2022
Action required: 705 - Other - as specified
Due 1 April 2022
Resolved 29 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2020 Resolved
Vessel shall provide correct light and day shape configuration for the tow being conducted prior to towing.
Action required: 705 - Other - as specified
Due 7 April 2020
Resolved 29 September 2021
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 April 2020 Resolved
Vessel shall start and maintain records for towline and terminal gear used for towing astern or alongside prior to towing
Action required: 705 - Other - as specified
Due 7 April 2020
Resolved 29 September 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 December 2019 Resolved
Make vessel ready and available for inspection. Vessel to be put into laid up status until completed.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 December 2019
Resolved 19 May 2021
Resolution: Vessel made ready for inspection.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 October 2019 Resolved
Emergency escape exit hatch in the main deck lounge overhead does not open freely. Make permanent repairs to ensure the emergency exit opens easily.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2019
Resolution: Hatched properly repaired.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 October 2019 Resolved
Post operating instructions for installed fire fighting system on aft deck emergency generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 December 2019
Resolution: Operating instructions installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2019 Resolved
Ensure all hot water heaters are properly installed and secured from rolling by straps or other devices.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 May 2021
Resolution: All hot water heaters properly installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 October 2018 Resolved
Fire extinguishing equipment installed must be maintained in accordance with a recognized industry standard; the engine room siren supply piping is cut rendering the system inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 28 March 2019
Resolution: Verified the supply piping was repaired and witnessed a satisfactory pressure test.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 October 2018 Resolved
Fire extinguishing equipment installed must be maintained in accordance with a recognized industry standard; the galley hood system is a dry chemical type and beyond its serviceable life.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2019
Resolved 28 March 2019
Resolution: Verified installation of a new ANSUL Marine R-102 system and witnessed a satisfactory operational test.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 March 2018 Resolved
Display an up-to-date SPV Decal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 May 2018
Resolution: Verified placement of provided SPV decals.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 6 March 2018 Resolved
Prove proper operation of ventilation fire dampers for the liquor locker and forward lounge.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 May 2018
Resolution: Witnessed an operational test of the fire dampers.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 March 2018 Resolved
Conduct underway drills prior to commencing the season.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 May 2018
Resolution: Witnessed crew drills.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 6 March 2018 Resolved
Submit required plans for starboard generator renewal and conduct installation to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 8 May 2018
Resolution: Vessel rep did not have sufficient time to execute generator upgrade. Existing starboard generator was put back into service.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 6 March 2017 Resolved
Vent opening closures for the engine compartment failed to operate freely and close completely. Maintenance hinge devices and provide method for a secured fit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 11 May 2017
Resolution: Verified all hinges for ventilation closure devices operated freely and a means to secure in place was provided.
Construction/Loadline › Structures › Deck Plating
Issued 2 November 2016 Resolved
Identified the stbd forward ovhd deck in aft steering was wasted and holed through. Provide proposal to make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 23 February 2017
Resolution: Verified wasted sections of aft main decking was cropped and renewed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 November 2016 Resolved
Identified exposed conductor and terminal connections for fwd water heaters. Provide covers or make connections within an enclosure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 9 May 2017
Resolution: Verified instalation of electrical box covers.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 November 2016 Resolved
Identified water heater located in fwd berthing that was not securely installed. Secure from rolling with straps or other device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 9 May 2017
Resolution: Verfied water heater was properly secured.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 2 November 2016 Resolved
Renew broken electrical outlet cover identified in the bar area.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 9 May 2017
Resolution: Verfied cover was renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 November 2016 Resolved
Provide missing fluoreescent light fixture cover in the fwd sewage space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 9 May 2017
Resolution: Verified cover was installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 15 September 2016 Resolved
Replace starboard main engine coupling between shaft and reduction gear. Vessel is restricted from carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 9 May 2017
Resolution: Witness underway operation test. All sat.

Casualty record · 13

12 June 2003Routine · role: Involved in a Marine Casualty · activity 1826623
9 July 2005Routine · role: Involved in a Marine Casualty · activity 2475499
31 May 2006Routine · role: Involved in a Marine Casualty · activity 2680097
7 July 2006Routine · role: Involved in a Marine Casualty · activity 2711970
26 July 2007Routine · role: Involved in a Marine Casualty · activity 3082604
19 August 2007Routine · role: Involved in a Marine Casualty · activity 3034547
11 May 2008Routine · role: Involved in a Marine Casualty · activity 3204649
19 September 2009Routine · role: Involved in a Marine Casualty · activity 3646144
28 June 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3832159
21 July 2010Routine · role: Involved in a Marine Casualty · activity 3827075
10 August 2011Routine · role: Involved in a Marine Casualty · activity 4113560
17 July 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4388147
25 May 2025Routine · role: Involved in a Marine Casualty · activity 8172571
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SPIRIT OF COLUMBIA (2003–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.