CHIMBORAZO

CHIMBORAZO is a 1999 tank ship. The Coast Guard has recorded 3 inspections in 2017, along with 5 deficiencies.

Records in 2017. Most recent: inspection, 8 May 2017.

Built
1999
Last inspected
8 May 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 May 2017
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9174581
504825
Flag
ECUADOR
Maury page id
psix-504825

Documentation record

Tonnage as PSIX records it35770 - Regulatory (Subpart C or D), Gross Ton
20199 - Regulatory (Subpart C or D), Net Ton
66318 - Dead Weight, Ton
78336 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

8 May 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6141627
5 April 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6118376
1 April 2017 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6112267

Deficiency record · 5

Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 1 April 2017 Resolved
The vessels AIS is not operating properly, the AIS last operated properly around March 19th, during their PERU Port call. Reg 19.1.2.3
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 1 April 2017
Resolved 5 April 2017
Resolution: Received e-mail with scanned technician report #387419 from Mackay Marine from agent stating a deficiency issued from Activity #6112267 has been rectified. Tech report states: Multiple tests were conducted and found the AIS fully operational. All Sat
Operations/Management › Vessel Traffic Service › Deviation from VTS Rules
Issued 1 April 2017 Resolved
Vessel failed to notify the COTP that AIS was inoperable.
Condition: Improper/Lack of Maintenance
Due 1 April 2017
Resolved 1 April 2017
Resolution: PSCO informed CAPT of the requirements to report inoperable navigational equipment to USCG, and the requirement to request a deviation if the equipment is inoperable.. Captain claimed the vessel was unaware that it was inoperable..
Engineering › Generator (propulsion/auxiliary-electric) › Generator Excitation Circuitry
Issued 1 April 2017 Resolved
The vessels #3 generator requires replacement filters to operate satisfactorily. The vessel does not have spares on board rendering the generator inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 8 May 2017
Resolution: Filter replaced and Surveyor attested to satisfactory operation.
Engineering › Lubricating Oil Service System › Piping
Issued 1 April 2017 Resolved
After any survey of the ship has been completed, no change shall be made in the structural arrangments, machinery equipment without the sanction of the adminstration. PSCO observed eleven areas of concern along the hydraulic oil lines on the cargo deck. The crew attempted to repair leaks along the lines by removing protective casing and making temporary repairs.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 May 2017
Resolution: Surveyor attested to repairs and satisfaction of general exam performed on hydraulic lines.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 April 2017 Resolved
The vessel owner or operator must ensure that they maintain one english copy of the VRP and a copy of Coast Guard approval letter onboard. The vessel failed to provide Coast Guard approval letter of VRP.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 April 2017
Resolution: Vessel submitted a copy of the VRP approval letter.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.