Records from 1999 to 2010. Most recent: inspection, 4 November 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
4 November 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3882110
7 July 2009
Type not recorded
No type recorded · USCGC SEAHAWK (WPB 87323) · USCG Southeast District (CGD-SE) · Activity 3529013
11 May 2009
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3472696
19 November 2008
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3366321
4 September 2008
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3318344
21 August 2008
Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3304616
29 November 2007
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3106551
23 July 2007
PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3005155
25 March 2006
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2621926
13 February 2006
Random ISPS/MTSA/PSC · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2582586
6 September 2005
Random ISPS/MTSA/PSC
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2485455
11 February 2005
MARPOL Annex I Examination · ISPS III Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2290276
2 July 2004
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2117858
27 January 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1993950
22 February 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1748518
27 June 2002
Administrative Inspection
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1637937
15 January 2002
Administrative Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1478724
20 November 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 295693
30 August 2001
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 1496648
9 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 289992
7 December 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 435539
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 21 August 2008
Resolved
Replace expired hydrostatic release for EPRIB, prior to departure. SOLAS 74/78 IV/7
Action required: 17 - Rectify deficiencies prior to departure
Due 21 August 2008
Resolved 21 August 2008
Resolution: Recieved notification of the replacement of the hydrostatic release.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 21 August 2008
Resolved
Noted that the Safety Equipment Certificate specifies 02x 12 man liferafts. Ship currently has 02x 10 man: reducing it capacity below 150%. Class to ammend certificate or attest to correction nlt 29AUG08. SOLAS 74/78 III/31
Action required: 705 - Other - as specified
Due 29 August 2008
Resolved 29 August 2008
Resolution: Attended the vessel and saw documentation from class attesting to the correction of the liferafts. Observed the liferafts and confirmed that the two 10 man rafts had indeed been replaced by two 12 man liferafts.
Lifesaving › Rescue Boat › Construction
Issued 13 February 2006
Resolved
Provide a mooring bit forward on the rescue boat to secure the rescue boat's sea painter to the ship while underway as required by SOLAS 74/78 III-17(3).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 March 2006
Resolved 25 March 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 13 February 2006
Resolved
Provide non-conductive matting for emergency generator as required by SOLAS 74/78 II-1-45(2).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 13 February 2006
Navigation › Piloting/Steering
Issued 22 February 2003
Resolved
The vessel's Maneuvering Information Fact Sheet is incomplete. Add missing information IAW 33 CFR 164.35. LEGACY COMPONENT DESC: Maneuvering Information Fact Sheet
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 February 2003
Resolved 25 February 2003
Resolution: Received corrected copy of Maneuvering Information Fact Sheet.
Documentation › Certificates/Documents
Issued 22 February 2003
Resolved
The vessel's Certificate of Class is expired. Provide new certificate to USCG. LEGACY COMPONENT DESC: Certificate of Class
Action required: 705 - Other - as specified
Due 26 February 2003
Resolved 25 February 2003
Resolution: Received proper documentation.
Engineering
Issued 20 November 2001
Resolved
Fuel Oil Purifier flush piping currently piped directly into bilge. Class to attest to proper instlation of Fuel Oil Purifier flush piping.
Condition: Unknown
Due 20 December 2001
Resolved 15 January 2002
Resolution: RECEIVED SATISFACTORY REPORT FROM GL CLASS RECTIFYING DEFICIENCY NOTED 20DEC01. SEE ATTACHED
Lifesaving
Issued 20 November 2001
Resolved
0610 Limit switich on rescue boat inoperative.
Condition: Unknown
Due 27 November 2001
Resolved 28 November 2001
Navigation
Issued 7 December 1999
Resolved
COMMS BETWEEN BRIDGE AND STEERING ROOM (ONLY ONE WAY COMMS.)
Condition: Unknown
Due 7 December 1999
Resolved 22 November 2000
Resolution: received satisfactory class report 22NOV00
Navigation
Issued 7 December 1999
Resolved
STEERING INSTRUCTIONS NOT POSTED ON BRIDGE OR IN STEERING ROOM
Condition: Unknown
Due 19 April 2000
Resolved 22 November 2000
Lifesaving
Issued 7 December 1999
Resolved
SHOW PROPER OPERATION OF LIMIT SWITCH ON STRB RESCUE BOAT DAVIT
Condition: Unknown
Due 19 April 2000
Resolved 22 November 2000
Documentation
Issued 7 December 1999
Resolved
IOPP STATES VESSEL EQUIPED WITH AUTO STOPING AND ALARM. HAVE CLASS VERIFY IOPP TO MATCH SHIPS EQUIPMENT.
Condition: Unknown
Due 7 December 1999
Resolved 18 April 2000
Resolution: Received class report rectifying issue.