Records from 1981 to 1993. Most recent: inspection, 20 May 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 23
20 May 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834231
4 June 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1255296
28 April 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257816
9 March 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1267058
25 February 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266503
12 October 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938230
13 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228759
17 January 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216700
12 October 1990
Drydock Extension · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233466
4 January 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916124
13 October 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039316
25 April 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895928
13 January 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043242
19 February 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1333586
10 November 1987
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312516
19 December 1986
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1027899
14 October 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322928
5 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300759
26 November 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995545
11 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990473
13 December 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970812
13 December 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279672
9 December 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965545
Lifesaving
Issued 12 October 1991
Resolved
REPLACE EPIRB AND PROVE PROPER OPERATION.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Electrical
Issued 12 October 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF DECCA RADAR.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Electrical
Issued 12 October 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF PORT ENGINEROOM SUPPLY BLOWER, LOCALLYAND REMOTELY.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Electrical
Issued 12 October 1991
Resolved
REPLACED BURN-OUT BULB FOR THE PORT EMBARKATION SPOTLIGHT.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Navigation
Issued 12 October 1991
Resolved
PROVE PROPER OPERATION OF THE SHEERING GEAR POWER FAILURE ALARM, PORT AND STARBOARD PUMPS.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Engineering
Issued 12 October 1991
Resolved
PROVE PROPER OPERATION OF OVERSPEED DEVICES FOR NO.1 & 2 MAIN ENGINES.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Electrical
Issued 12 October 1991
Resolved
FABRICATE NEW BATTERY BOX FOR NO.2 S/S GENERATOR STARTING BATTERIES.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Electrical
Issued 12 October 1991
Resolved
SECURE ALL LOOSE WIRING AND CABLE LOCATED IN NUMEROUS PLACES IN ENGINEROOM.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Electrical
Issued 12 October 1991
Resolved
PROPERLY LABEL DISTRIBUTION ELECTRICAL BOXES LOCATED IN ENGINEROOM (2) EA. CENTER LINE AND (1)EA. GALLEY AREA.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Navigation
Issued 12 October 1991
Resolved
REPAIR AND PROVE PROPER OPERATION ON BOARD SOUND POWERED PHONE SYSTEM.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Engineering
Issued 12 October 1991
Resolved
PROVE PROPER OPERATION OF RELIEF VALVES FOR STARTING AIR RECEIVERS, UPPER AND LOWER.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Construction/Loadline
Issued 12 October 1991
Resolved
REPAIR STEERING ROOM BILGE SECTION LOCATED IN THE ENGINEROOM BILGE MANIFOLDAFT, WELD CUT-OFF PIPE SECTION.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Navigation
Issued 12 October 1991
Resolved
REPAIR ANCHOR LIGHT, REPLACE NON-UNDER COMMAND LIGHT, REPAIR CONNECTION BOXFOR ANCHOR LIGHT, AND INSTALL CORRECT LIGHT LOCATED ON THE MAST.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Electrical
Issued 12 October 1991
Resolved
INSTALL PROPER OUTLET RECEPTABLE MARINE TYPE FOR WELDING MACHINE LOCATED CENTERLINE ENGINEROOM.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Lifesaving
Issued 12 October 1991
Resolved
PROVIDE ON LOCKS AND OARS FOR 16 FOOT ALUMINUM WORK/RESCUE BOAT.
Condition: Unknown
Due 12 October 1991
Resolved 12 October 1991
Fire Fighting
Issued 12 October 1990
Resolved
PROVIDE APPROVED HYDROSTATIC TEST OF (7) CO2 BII PORTABLE EXTINGUISHERS ANDANNUAL SERVICE.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Fire Fighting
Issued 12 October 1990
Resolved
PROVIDE APPROVED ANNUAL SERVICE OF (2) DC B-I AND B-II PORT FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Fire Fighting
Issued 12 October 1990
Resolved
RENEW IN LIKE KIND AND UALITY ENGINE ROON FIRE PUMP GAUGE.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Engineering
Issued 12 October 1990
Resolved
DEMONSTRATE PROPER OPERATION OF OVERSPEEDS FOR BOTH PORT AND STBD MAIN PROPULSION ENGINE.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Engineering
Issued 12 October 1990
Resolved
DEMONSTRATE PROPER OPERATION OF HIGH WATER TEMPERATURE ALARM FOR STBD MAIN PROPULSION.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Navigation
Issued 12 October 1990
Resolved
DEMONSTRATE PROPER OPERATION OF STEERING GEAR POWER FAILURE ALRAM ON BRIDGE.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Lifesaving
Issued 12 October 1990
Resolved
PROVIDE APPROVED HYDROSTATIC RELEASE UNITS FOR SWITLIK 20MAN L/R SER#33 LOT26 AND SWITLIK 10 MAN L/R SER#4 LOT#35.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Lifesaving
Issued 13 October 1989
Resolved
CONDUCT ANNUAL SERVICING OF BOTH INFLATABLE LIFE RAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Navigation
Issued 25 April 1989
Resolved
INSTALL SERVICABLE BATTERY AND PROVE PROPER OPERATION OF THE EPIRB.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Fire Fighting
Issued 25 April 1989
Resolved
CONDUCT HYDROSTATIC TEST OF BII (CO2) FIRE EXTINGUISHER LOCATED IN GALLEY.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 25 April 1989
Resolved
PROVIDE ON BOARD 6 SERVICABLE DAY FLARES AND 6 SERVICABLE NIGHT FLARES COAST GUARD APPROVED MODELS.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 13 January 1989
Resolved
INSTALL SERVICABLE BATTERY AND PROVE PROPER OPERATION OF THE EPIRB.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Fire Fighting
Issued 13 January 1989
Resolved
CONDUCT HYDROSTATIC TEST ON B-II (CO2) FIRE EXTINGUISHER LOCATED IN THE GALLEY.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Lifesaving
Issued 13 January 1989
Resolved
PROVIDE ON BOARD 6 USCG APPROVED SERVICABLE DAY FLARES AND 6 SERVICABLE NIGHT FLARES.
Condition: Unknown
Due 13 January 1989
Resolved 13 January 1989
Unknown
Issued 26 November 1985
Resolved
LIFEBOATS OR INFLATABLE LIFERAFTS ARE TO BE INSALLED IN ACCORDANCE WITH 46 CFR 94.10-20(B)(5).
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Engineering
Issued 11 October 1985
Resolved
REPAIR FUEL SHUT OFF REACH ROD, PORT SIDE.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985