MAURY USCG vessel records Sign in
← All vessels

MICHAEL J

MICHAEL J is a 1998 freight ship. The Coast Guard has recorded 43 inspections since 1999, most recently in April 2024, along with 34 deficiencies and 9 operational controls.

Records from 1999 to 2024. Most recent: inspection, 6 April 2024.

Built
1998
Last inspected
6 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9164421 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
505054
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-505054

Inspections, by type

…with no type recorded18
Years with a record 13 calendar years (1999–2024)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5850 - Convention (Subpart B), Gross Ton
2835 - Convention (Subpart B), Net Ton
6700 - Dead Weight, Ton
10216 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 43

6 April 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7890975
16 June 2014 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4890135
4 June 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4879294
10 June 2012 ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4339114
23 February 2011 COE-Administrative
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3950631
11 February 2011 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3943592
27 January 2011 ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3934030
25 January 2011 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3932873
10 January 2011 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3924224
27 December 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3916463
11 December 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3908672
27 November 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3899380
13 November 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3890395
30 October 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3881188
15 October 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3870556
16 September 2010 COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3850920
21 June 2007 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2968780
18 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2938247
10 May 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2927119
9 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2925709
11 January 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2854471
9 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2852581
21 September 2006 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2783493
18 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2781296
3 August 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2734611
4 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2641185
21 July 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2440321
20 January 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2278610
13 January 2005 Ballast Water Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2274045
28 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2230021
6 October 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2214921
29 September 2004 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2208585
20 August 2004 In-Service Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2171526
4 July 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2120643
1 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2015851
7 December 2003 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1960029
12 November 2003 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1945196
12 August 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1873324
29 November 2001 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295871
10 May 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 289867
27 October 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 283564
31 August 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 281618
25 September 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433158

Deficiency record · 34

Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 June 2014 Resolved
0945-Emergency Lighting-The emergency source of electrical power shall be capable of supplying for a period of 18 hrs emergency lighting. Emergency lighting onboard is not marked and is unable to be tested. -74 SOLAS (04 Cons) Ch. II-1/Reg 43.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2014
Resolution: CG examiner observed successful operational test of all emergency lighting.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 4 June 2014 Resolved
1430- Auxiliary Engines- Each emergency generator set shall be equipped with starting devices. A second source of energy shall be provided for an additional three starts. Ship's crew unable to successfully demonstrate secondary means of starting emergency generator. -74 SOLAS (04 Cons) Ch. II-1/Reg 44.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2014
Resolution: CG examiner observed successful start-up of emergency generator via secondary means (hydraulic hand pump).
Engineering › Steering Gear System › Follow-up Assembly
Issued 4 June 2014 Resolved
0936 -Steering Gear- Simple operating instructions with block diagram for remote steering gear control systems and power units shall be permanently displayed on navigation bridge. Steering gear block diagram not posted on bridge. -74 SOLAS (09 Cons) Ch. V/Reg 26.3.1
Condition: Improper/Lack of Maintenance
Due 19 June 2014
Resolved 6 June 2014
Resolution: Steering gear block diagram is now posted on the bridge.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 10 June 2012 Resolved
SOLAS74(2001 cons) II-2/5-1-12 Pressure components of fire extinguishing medium shall be designed to the satisfaction of the administration. Two hoses on high- pressure carbon dioxide fixed system have deteriorated/dry rot to an extent that they must be replaced.
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 20 December 2012
Resolution: PSCO conducted visual inspection of hoses and determined that required hoses have been renewed.
Construction/Loadline › Markings › Load Line Mark
Issued 10 June 2012 Resolved
ICLL66 Annex I/Reg 8 The ring, lines and letters shall be painted in white or yellow on a dark ground on all load line marks. The vessel's deck line was painted the same color as the color of the background.
Action required: 705 - Other - as specified
Resolved 10 June 2012
Resolution: Vessel personnel painted the deck line white to contrast background.
Stability › Weathertight Integrity › General
Issued 10 June 2012 Resolved
ICLL66 Annex I /16(4) The means for securing and maintaining weathertightness shall be to the satisfaction of the administration. Emergency escape hatches in steering gear room and engineer workshop could not properly be secured as sunlight was visible through hatch edges when cleats/dogs were fully closed.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 June 2012
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 10 June 2012 Resolved
SOLAS 74 (2001 cons) II-2/17.3 All ships shall carry at least two fireman's outfits complying with the requirements of paragraph 1 (protective clothing of material to protect the skin from heat). One of the vessel's fire suits has multiple holes/tears and does not protect the wearers skin from heat.
Action required: 705 - Other - as specified
Due 24 June 2012
Resolved 20 December 2012
Resolution: PSCO verified renewal of deteriorated fireman''s suit and the presence of required quantity on-board.
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 27 January 2011 Resolved
2560 - Company verification, review and evaluation: The company shall ensure that the SMS policy is implemented and maintained at all levels and in addition periodically evaluate the efficiency of, and when needed review the SMS. An audit of the security/SMS procedures is required as per Captain of the Port order no. 3934030. 2009 SOLAS IX Reg 3.1, ISM Code Part A 2.2 & 12.2
Action required: 17 - Rectify deficiencies prior to departure
Due 27 November 2011
Resolved 28 January 2011
Electrical › Mast › Lightning Ground
Issued 21 June 2007 Resolved
AFT OF BRIDGE, AN ANTENNA WITH EXPOSED WIRE.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 July 2007
Resolved 12 July 2007
Lifesaving › Buoyant Smoke Signals › General
Issued 21 June 2007 Resolved
BRIDGE WING ASMOKE AND LIGHT BUOY, MISSING CURRENT EXPIRATIONS DATE. PORT SIDE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 July 2007
Resolved 12 July 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 21 June 2007 Resolved
OWS SYSTEM HAS A BROKEN PUMP, RECIEVED WHILE CG ON BOARD NEW PUMP WILL HAVE SYSTEM DONE LATER THAT DAY.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 July 2007
Fire Fighting › International Shore Connection › Not on Board
Issued 13 January 2005 Resolved
International shore tie connection missing from starboard side storage location.
Action required: 15 - Rectify deficiencies by next port
Due 20 January 2005
Resolved 21 January 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 13 January 2005 Resolved
Open electrical junction boxes with exposed bare wires were found in the fuel oil filter room and steering gear room
Action required: 15 - Rectify deficiencies by next port
Due 20 January 2005
Resolved 21 January 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 January 2005 Resolved
Starboard forward ring buoy light was found inoperable.
Action required: 15 - Rectify deficiencies by next port
Due 20 January 2005
Resolved 20 January 2005
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 January 2005 Resolved
Numerous combustible items and boxes were found stored behind main switchboard in engine control room.
Action required: 15 - Rectify deficiencies by next port
Due 20 January 2005
Resolved 20 January 2005
Operations/Management › Drills/Instruction › Fire
Issued 13 January 2005 Resolved
Vessel and crew is to review fire fighting procedures and conduct appropriate training. U.S. Coast Guard to re-attend and witness drills
Action required: 15 - Rectify deficiencies by next port
Due 20 January 2005
Resolved 20 January 2005
Documentation › Markings/Placards › Oil Discharge Placard
Issued 13 January 2005 Resolved
No line diagram was posted identifying oily water separator system. A line diagram must be posted to show this system. Placard must also be posted.
Action required: 15 - Rectify deficiencies by next port
Due 20 January 2005
Resolved 20 January 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 13 January 2005 Resolved
Two light covers are broken and or missing on starboard side main engine room.
Action required: 15 - Rectify deficiencies by next port
Due 20 January 2005
Resolved 20 January 2005
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 4 July 2004 Resolved
Repair # 2 emergency fire pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 July 2004
Resolved 4 July 2004
Resolution: Emergency fire pump # 2 was repair.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 4 July 2004 Resolved
Install small gate/door on AO BLK at engine work shop at after most door at top were the railing for hosting equipment was installed.
Condition: Improper Installation
Due 4 August 2004
Resolved 18 August 2004
Resolution: Installed small door on A0 BLK at engine work shop at the after most door at top were railing for hoisting equipment.
Fire Fighting › Means of Escape
Issued 12 November 2003 Resolved
Clear emergency escape route in steering gear room. LEGACY COMPONENT DESC: Corridors
Due 12 December 2003
Resolved 13 November 2003
Resolution: Recieved Master''s statement, deficiency corrected.
Engineering
Issued 12 November 2003 Resolved
Store compressed air bottles in steering gear room in a storage locker or storage rack.
Condition: Improper Installation
Due 12 December 2003
Resolved 13 November 2003
Resolution: Recieved Master''s statement, deficiency corrected.
Engineering › Fuel Oil Storage/Transfer System
Issued 12 November 2003 Resolved
Update bunker procedures in accordance with 33 CFR 155.750.
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 12 December 2003
Resolved 13 November 2003
Resolution: Recieved Master''s statement, deficiency corrected.
Deck/Cargo › Cargo Stowage
Issued 12 November 2003 Resolved
Have Class/Flag State attend vessel to update name change on Cargo Securing Manual.
Due 12 December 2003
Resolved 25 November 2003
Resolution: Recieved Master''s statement and copy of approved and corrected Cargo Securing Manual, deficiency corrected.
Deck/Cargo › Holds/Tanks
Issued 12 November 2003 Resolved
Repair/Replace emergency stop switch to hatch cover #3 Port side to original. LEGACY COMPONENT DESC: Hatch Cover
Due 12 December 2003
Resolved 5 December 2003
Resolution: Recieved Master''s statement, deficiency corrected.
Documentation
Issued 27 October 2000 Resolved
Master license does not meet tonnage STCW 95 Requirement. Provide appropriate license for master.
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Fire Fighting
Issued 27 October 2000 Resolved
Clear items blocking firestation on aft Poop Deck portside.
Condition: Unknown
Due 30 October 2000
Resolved 30 October 2000
Navigation
Issued 27 October 2000 Resolved
Provide sailing directions for area transiting prior to next U.S. port.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Fire Fighting
Issued 27 October 2000 Resolved
Install new brackets for both port and starboard side smoke signals. Smoke cans loose, tied in place.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Documentation
Issued 27 October 2000 Resolved
Include local point of contacts on SOPEP prior to next U.S. port.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Electrical
Issued 27 October 2000 Resolved
Repair lights in emergency escape of engine room prior to next U.S. port.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Documentation
Issued 25 September 1999 Resolved
PROVIDE BUNKERING PROCEDURES IAW 33CFR.155.720.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Documentation
Issued 25 September 1999 Resolved
PROVIDE A COPY OF VESSELS SOPEP ONBOARD. PROVIDE MSO SAN JUAN A COPY OF THECLASS APPROVAL LETTER, TABLE OF CONTENTS AND PORT CONTACTS FOR PUERTO RICO,USA PRIOR TO 02OCT99. (33CFR151.26)
Condition: Unknown
Due 26 September 1999
Resolved 26 September 1999
Navigation
Issued 25 September 1999 Resolved
PROVIDE OPERATING INSTRUCTIONS WITH A BLOCK DIAGRAM SHOWING CHANGE OVER INSTRUCTIONS FOR REMOTE STEERING GEAR.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000

Ownership record