Records from 1981 to 1986. Most recent: inspection, 18 August 1986.
Documentation record
Registered dimensions (L × B × D)97.2 ft × 26.0 ft × 6.7 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · BAYOU LA BATRE, AL, UNITED STATES · built 1979
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsCoastwise, unrestricted
DocumentationInvalid
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
98 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
18 August 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1292593
14 August 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1292962
17 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292096
23 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287382
11 September 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283645
10 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281269
6 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281773
6 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967593
13 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964805
9 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274287
10 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272160
Engineering
Issued 23 April 1985
Resolved
REMOVE PLASTIC SITE GLASS FROM FUEL OIL DAY TANK AND PROVIDE PYREX GLASS ORPLUG.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Navigation
Issued 23 April 1985
Resolved
TEST SINGLE SIDE BAND RADIO ON 2182 KHZ.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Engineering
Issued 23 April 1985
Resolved
MAKE OPERABLE FORWARD AIR COMPRESSOR.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Unknown
Issued 23 April 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, DAKOTA ARROW, DN615741
Condition: Unknown
Due 23 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 23 April 1985
Resolved
PROVIDE APPROVED PLANS FOR MODIFICATION TO FIRE MAIN PIPING AND FIRE/ BALLAST PIPING.
Condition: Unknown
Due 23 May 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 23 April 1985
Resolved
REPAIR AND TEST FIRE/BALLAST PUMP TO ENSURE SUFFICIENT PRESSURE.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Engineering
Issued 23 April 1985
Resolved
PROVIDE MACHINERY GUARDS FOR BOTH MAIN ENGINES.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Engineering
Issued 23 April 1985
Resolved
REMOVE PECOCKS RACOR FILTER AND PROVIDE PLUGS. PROVIDE FLAME BOWLS FOR RACOR FILTERS.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Engineering
Issued 23 April 1985
Resolved
TEST AIR RECEIVER PRESSURE RELIEF VALVE.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Accommodation/Occupational Safety
Issued 23 April 1985
Resolved
REPAIR FAN FOR GALLEY RANGE EXHAUST.
Condition: Unknown
Due 23 April 1985
Resolved 23 April 1985
Documentation
Issued 10 May 1984
Resolved
CORRECT THE 1983 LIGHT LIST USING NOTICE TO MARINERS OR PURCHASE A NEW 1984LIGHT LIST.
Condition: Unknown
Due 10 May 1984
Resolved 10 May 1984
Unknown
Issued 10 May 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE DAKOTA ARROW, DN615741.
Condition: Unknown
Due 10 May 1984
Resolved 10 May 1984
Electrical
Issued 10 May 1984
Resolved
HAVE THE SECOND GENERATOR OVERSPEED CHECKED IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 10 May 1984
Resolved 10 May 1984
Unknown
Issued 13 May 1983
Resolved
PRESENT FOR ITERNAL INSPECTION THE STARTING AIR RECEIVER.
Condition: Unknown
Due 13 May 1983
Resolved 13 May 1983