MAURY USCG vessel records Sign in
← All vessels

FLYING FISH II

FLYING FISH II is a 2001 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1999, most recently in November 2025, along with 59 deficiencies.

Records from 1999 to 2025. Most recent: inspection, 25 November 2025.

Built
2001
Last inspected
25 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK3100
505347
Flag
UNITED STATES
368041960
Maury page id
psix-505347

Inspections, by type

…with no type recorded3
Years with a record 23 calendar years (1999–2025)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 15.5 ft × 8.0 ft
Registered tonnagegross 41 / net 33
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKLEY'S MARINA INC · BALTIMORE MD, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portSARASOTA, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 31 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it41 - Simplified, Gross Ton
33 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK3100MMSI 368041960 · active · compulsorily equipped · granted 31 May 2018, expires 31 May 2028
WDI7621MMSI 367103360 · expired · compulsorily equipped · granted 27 April 2016, cancelled 27 June 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDC9519MMSI 367103360 · terminated · voluntarily equipped · granted 30 March 2006, cancelled 13 April 2016 · licensed under a name not among this hull’s recorded names (not shown)
WDA7888MMSI 366848280 · expired · compulsorily equipped · granted 20 April 2002, cancelled 2 July 2011 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 47

25 November 2025 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8259508
10 April 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8100663
1 March 2025 Administrative Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8086789
8 March 2024 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7875855
31 March 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7648933
22 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7634010
17 February 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7389085
19 February 2021 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7142993
19 November 2020 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7098554
18 November 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6857964
6 September 2019 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6776993
27 March 2019 Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6642474
13 February 2018 Deficiency Check · Administrative Inspection · COI Inspection · Examination of Repairs · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6354291
11 October 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6251539
4 September 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6264178
28 June 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6176994
14 April 2017 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6122311
27 September 2016 Simplified Stability Test
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6005834
13 April 2016 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5856225
31 August 2015 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5231601
24 August 2015 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5225952
29 September 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4156882
28 July 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4097503
13 January 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3926470
5 January 2011 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3919411
15 November 2010 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3891680
24 October 2010 Type not recorded
No type recorded · Station St Inigoes · USCG East District (CGD-E) · Activity 3876825
24 October 2010 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3879712
4 December 2009 DAPI Audit · Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3644607
26 March 2009 Annual Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3440727
5 December 2008 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3373592
1 April 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3175687
5 December 2007 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3109990
3 April 2007 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2904722
30 March 2007 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2898387
28 March 2006 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2597056
26 October 2005 Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2524083
20 September 2005 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2496835
29 March 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2322500
16 March 2005 Periodic Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2312021
13 April 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2113619
28 August 2003 Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1889670
8 April 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1771656
25 March 2003 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1762579
9 April 2002 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1484108
27 April 2001 Plan Review "T" Boat · Initial Certification · Inclining Experiment · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1468234
28 September 1999 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1461204

Deficiency record · 59

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 April 2025 Resolved
46 CFR 182.530 (a) On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI observed that visual indicator for the engine room and cabin bilge alarm was not operational. Enact permanent repairs to the satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2025
Resolved 11 July 2025
Resolution: Received vidoe of operational visual indicators.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 April 2025 Resolved
46 CFR 180.130 (a) (1) Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel. MI observed that the float-free link for 22 person life float was not attached to the vessel.
Action required: 10 - Deficiency Rectified
Resolved 10 April 2025
Resolution: Weak link was attached to the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2025 Resolved
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessels anniversary date was 23Nov2024, and vessel is past 3 months from said date. Vessel shall not operate with passengers until an annual inspection has been completed. 46CFR176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2025
Resolved 10 April 2025
Resolution: Completed annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 March 2024 Resolved
The installed fire fighting system in the engine room (FireBoy) had its maintenance pin installed and the manual pull was not hooked up. This would prevent manual operation of the FireBoy system. Correctly hook up manual pull cable and remove the maintenance pin. 46 CFR 176.810
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 March 2024
Resolved 19 March 2024
Resolution: Systems was properly set up by the third party fire company that did the maintenance.
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 19 March 2024 Resolved
A vessel of not more than 65 feet is not required to carry a rescue boat unless the OCMI determines the vessel can act as its own. The freeboard is over 2' which would require a swim platform or equivalent recovery method. Propose a suitable plan to recover a helpless person from the water within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2024
Resolved 15 July 2024
Resolution: MOB recovery system, SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 March 2024 Resolved
Vessel must undergo an annual inspection as specified in paragraph (b)(1) of this section. Vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessels anniversary date was 23Nov2023, and vessel is past 3 months from said date. Vessel shall not operate with passengers until an annual inspection has been completed. 46CFR176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 March 2024
Resolved 19 March 2024
Resolution: Completed annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 February 2023 Resolved
General arrangement and outfitting internal combustion engine exhausts must be kept clear of and suitably insulated from combustible material. MI found the ships diesel generator exhaust hose chaffed from contact with engine room hatch. 46 CFR 177.405(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 7 March 2023
Resolution: Owner sent proof of repair via email.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 February 2023 Resolved
Each connection to a conductor or terminal part of a conductor must be made within a pressure type connector on each conductor. MI found the battery charger connected with a standard three prong 120 volt AC connector. 46 CFR 183.340 (g)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 March 2023
Resolved 7 March 2023
Resolution: Owner sent proof of repair via email.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 22 February 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MI found the vessels freeing ports obstructed by one way valves. Complete repair during Credit drydock scheduled for 31MAR23. 46 CFR 177.100
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 31 March 2023
Resolution: MI attended vessel. Removal of scupper obstruction verified. All sat.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 23 November 2020 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’ must be stenciled in a contrasting color on each bucket. No fire buckets found onboard. 46CFR181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 December 2020
Resolved 8 December 2020
Resolution: Vessel rep attained 3 fire buckets and brought up to regulation. See Documents for photo.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2020 Resolved
A vessel to which this subchapter applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. The vessel is two months passed required inspection date. 46CFR176.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2020
Resolution: Completed Inspection for Certification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 September 2019 Resolved
A vessel must be provided with an auxiliary means of steering that is: Capable of moving the rudder from 15 degrees on one side to 15 degrees on the other side. Prove operation of auxiliary steering. 46CFR182.620
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2019
Resolution: Witnessed satisfactory operation of auxiliaty tiller.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 September 2019 Resolved
Each inlet or discharge pipe that penetrates the hull below 6 inches above the deepest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. Provide cap for out of service through hull valve in engine room. 46CFR179.350(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2019
Resolution: Metallic end cap secured to fitting.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 September 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. Replace expired items in first aid kit. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 September 2019
Resolution: Operator replaced expired items.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 27 March 2019 Resolved
Vessel must be provided with a main steering gear of adequate strength. Rudder poist assembly bushing is cracked through on the forward most part IAW 46 CFR 182.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2019
Resolution: Vessel o/o replaced piece
Engineering › Steering Gear System › Interlock
Issued 7 June 2018 Resolved
A vessel must be provided with an auxiliary means of steering capable of moving the rudder from 15 degrees on one side to 15 degrees on the other side... Crew was unable to demonstrate operation of hand tiller due to improper fitting of tiller to rudder post. Prove operation of auxiliary steering as required. 46 CFR 182.620(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 23 June 2018
Resolution: Operator fabricated new auxiliary tiller. Witnessed proper operation.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 7 June 2018 Resolved
Provision must be made for closing all supply and exhaust discharge openings for a space protected by a fixed gas extinguishing system. Make repairs to starboard side ventilation closure and prove proper operation of closing device. 46 CFR 182.465(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2018
Resolved 18 June 2018
Resolution: Verified proper operation of closure device.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 June 2018 Resolved
An Employee Assistance Program (EAP) training program must be conducted for the employer's crew-members and supervisory personnel. Provide proof employees have received EAP training. 46 CFR 16.401(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2018
Resolved 18 June 2018
Resolution: Received proof of EAP training.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 June 2018 Resolved
Each vessel must be marked as required by part 67, subpart I. Place name of vessel (FLYING FISH II) on port and starboard bow; four inches in height. 46 CFR 185.602(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2018
Resolved 18 June 2018
Resolution: Owner places name of vessel on port and starboard sides as required.
Lifesaving › Lifefloat › Quantity
Issued 21 July 2017 Resolved
Vessel has a single 12 person lifefloat onboard. Reduce passenger/crew capacity to 12 personnel until new lifefloats are installed to the satisfaction of the attending USCG marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 2 October 2017
Resolution: Witnessed proper installation of appropriate lifefloats.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 21 July 2017 Resolved
Vessel did not have the current Coast Guard issued Certificate of Inspection onboard. Locate the vessel's COI, or request replacement from Coast Guard Sector Maryland-NCR, and post as required by 46 CFR 176.302.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2017
Resolution: Sector Hampton Roads to reissue Sector Maryland-NCR COI with updated drydock information and annual endorsement.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 June 2017 Resolved
FCC Safety Radio Certificate has an inaccurate radio call sign number. Provide updated certificate to match the Radio Station Authorization (WDI7621)
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 4 September 2017
Resolution: Vessel's owner submitted copy of corrected FCC Communications Act Safety Radiotelephony Certificate reflecting the same Call Sign as the FCC Radio Station Authorization.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 June 2017 Resolved
Vessel does not have current copies of CG Light List and Coast Pilot for operating areas.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 7 July 2017
Resolution: Vessel rep provided a print out version of the up to date Light List and Coast Pilot.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 28 June 2017 Resolved
Vessel did not have a Captain present with a valid Master's license or radio operator permit to operate the vessel.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 21 July 2017
Resolution: Licensed master for the vessel was in attendance for the third visit of the annual inspection. Provided all requested documentation and conducted operational test of machinery and conducted emergency drills.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 June 2017 Resolved
Vessel does not have current enrollment for a drug and alcohol program.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 21 July 2017
Resolution: Licensed master for the vessel was in attendance for the third visit of the annual inspection. Provided all requested DAPI documentation. Vessel master is enrolled in DAPI program.
Lifesaving › Lifefloat › Not on Board
Issued 28 June 2017 Resolved
Vessel is missing lifefloats required by COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 21 July 2017
Resolution: Vessel representatives installed (01) lifefloat with a capacity of 12 personnel. Issued new CG-835 limiting passenger count.
Communications › Radio Communications › EPIRB
Issued 28 June 2017 Resolved
EPIRB hydrostatic release is expired.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 7 July 2017
Resolution: Vessel rep replaced EPIRB HRU. Marine inspector confirmed that the EPIRB is installed properly.
Operations/Management › Vessel Activity › Underway
Issued 28 June 2017 Resolved
Vessel was unable to conduct underway operational testing steering and propulsion due to there not being a licensed mariner onboard during the inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 21 July 2017
Resolution: Licensed master for the vessel was in attendance for the third visit of the annual inspection. Provided all requested documentation and conducted operational test of machinery and conducted emergency drills.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 June 2017 Resolved
Vessel was unable to conduct emergency drills due to the absense of a credential mariner during the inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 21 July 2017
Resolution: Licensed master for the vessel was in attendance for the third visit of the annual inspection. Provided all requested documentation and conducted operational test of machinery and conducted emergency drills.
Engineering › Bilge Water Management System › Not Operational
Issued 28 June 2017 Resolved
Vessel's bilge pumps were not properly connected to conduct operational testing.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 7 July 2017
Resolution: Vessel rep demonstrated proper operation of all electric bilge pumps.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 June 2017 Resolved
Vessel was unable to conduct test of bilge high level alarms.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2017
Resolved 21 July 2017
Resolution: Vessel rep demonstrated the proper testing of the bilge high level alarms.
Lifesaving › Lifebuoys › Approval
Issued 13 April 2016 Resolved
Remove white life ring buoy and replace with approved orange life ring. Vessel limited to Lakes, Bays and Sounds until replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 20 April 2016
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifefloat › Serviceable
Issued 13 April 2016 Resolved
Grab lines and basket ring lines wasted. Repair or replace life floats. Repair outer shell of both life floats with approved repair kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 26 April 2016
Resolution: Attended vessel and cleared above deficiency.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 April 2016 Resolved
FCC Radio Station license expired/Renew.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 27 April 2016
Resolution: Deficiency cleared administratively by Sector Hampton Roads.
Lifesaving › Lifefloat › Float-free Link
Issued 13 April 2016 Resolved
Weak link tags missing. Replace weak link with approved size link with tags.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 26 April 2016
Resolution: Attended vessel and cleared above deficiency.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 13 April 2016 Resolved
Alcohol test kit missing, 2 required only 1 onboard. Add another kit.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 20 April 2016
Resolution: Attended vessel and cleared above deficiency.
Engineering › Bilge Water Management System › Pump
Issued 13 April 2016 Resolved
02 aft electric submersible bilge pumps are not U/L listed. Replace with proper U/L listed bilge bumps.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2016
Resolved 26 April 2016
Resolution: Attended vessel and cleared above deficiency.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 August 2015 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 July 2017
Resolution: Deficiency cleared administratively by Sector Hampton Roads.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 August 2015 Resolved
46 CFR 180.71(b) requires one child size lifejacket be available for each child on board. Vessel had 8 children onboard with only 3 child size lifejackets.
Action required: 705 - Other - as specified
Resolved 28 June 2017
Resolution: Deficiency cleared administratively by Sector Hampton Roads.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 August 2015 Resolved
Vessels COI and Stability Letter allows for not more than 30 persons onboard. Vessel was observed operating with 38 persons onboard (28 adult and 8 child passengers and 2 crew)
Action required: 705 - Other - as specified
Resolved 28 June 2017
Resolution: Deficiency cleared administratively by Sector Hampton Roads.
Lifesaving › Lifebuoys › Stowage
Issued 5 January 2011 Resolved
Replace retro reflective tape on ring life buoy IAW 46 CFR 180.70
Due 12 January 2011
Resolved 13 January 2011
Resolution: Vessel replaced retro reflective tape on ring life buoy IAW 46 CFR 180.70
Lifesaving › Hand Flares › Quantity
Issued 5 January 2011 Resolved
Need one (1) red flare IAW 46 CFR 180.68 (a). Limited to Lakes, Bays and Sounds route.
Due 12 January 2011
Resolved 13 January 2011
Resolution: Vessel provided one (1) red flare IAW 46 CFR 180.68 (a).
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 January 2011 Resolved
Provide updated NOAA registration for EPIRB IAW 46 CFR 180.64. Limited to 3 NM from shore.
Due 12 January 2011
Resolved 13 January 2011
Resolution: Vessel provided NOAA registration for EPIRB IAW 46 CFR 180.64.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 5 January 2011 Resolved
Replace expired hydrostatic release unit for EPIRB IAW 46 CFR 180.64. Limited to 3 NM from shore.
Due 12 January 2011
Resolved 13 January 2011
Resolution: Vessel replaced hydrostatic release for EPIRB IAW 46 CFR 180.64.
Lifesaving › Lifefloat › Paddle
Issued 5 December 2007 Resolved
Label paddles with vessel name.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 January 2008
Resolved 5 December 2007
Communications › Radio Communications › EPIRB
Issued 3 December 2007 Resolved
Provide hydrostatic release for EPIRB. Vessel is limited to operating within 3 miles from shore until hydrostatic release is provided.
Action required: 705 - Other - as specified
Resolved 5 December 2008
Resolution: Provided hydrostatic release for EPIRB.
Lifesaving › Hand Flares › Expired
Issued 3 December 2007 Resolved
Replace 3 expired red hand flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 January 2008
Lifesaving › Hand Flares › Not on Board
Issued 28 March 2006 Resolved
Missing 3 red and 5 orange flares. Provide prior to carrying passengers on board for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2006
Resolved 14 April 2006
Resolution: Received receipt for 3 red and 5 orange flares.
Documentation › Certificates/Documents › FCC SSL
Issued 28 March 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 14 April 2006
Resolution: Received fax of new FCC Station license and FCC radiotelephone certificate.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 March 2006 Resolved
Missing log book. Provide on board prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 March 2006
Resolved 14 April 2006
Resolution: Received fax from O/Op showing new log book.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2006 Resolved
Update First Aid kit IAW 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 15 April 2006
Resolved 14 April 2006
Resolution: Received fax from O/Op showing purchase of a new USCG approved first aid kit.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 April 2004 Resolved
Renew high water alarm indicator light for alarm under main cabin.
Action required: 705 - Other - as specified
Resolved 27 September 2004
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 April 2004 Resolved
Provide current tide tables for 2004.
Action required: 705 - Other - as specified
Resolved 27 September 2004
Engineering › Fuel Oil Service System
Issued 28 August 2003 Resolved
Provide metal frlame bowl for main engine Racor fuel filter. LEGACY COMPONENT DESC: Filter
Due 27 September 2003
Resolved 1 October 2003
Resolution: Owner provided a new flame bowl.
Engineering › Fuel Oil Service System
Issued 28 August 2003 Resolved
Provide watertight bulkhead penetration fittings for flexible fuel hose's to generator set. LEGACY COMPONENT DESC: Hose
Due 27 September 2003
Resolved 1 October 2003
Resolution: Owner corrected fuel hose penatrations in watertight blkhd.
Documentation › Markings/Placards › Warning Signs
Issued 8 April 2003 Resolved
PROVIDE LIFE JACKET DONNING PLACARD.
Action required: 705 - Other - as specified
Due 8 May 2003
Resolved 13 August 2004
Communications › Radio Communications
Issued 9 April 2002 Resolved
PROVIDE FCC STATION LICENSE. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 9 May 2002
Resolved 8 April 2003
Communications › Alarms/Indicators
Issued 9 April 2002 Resolved
LABEL FUEL SHUTOFFS AND HIGH WATER ALARMS. LEGACY COMPONENT DESC: High Water Alarm
Due 4 May 2002
Resolved 25 March 2003
Resolution: FUEL SHUTOFFS AND HIGH WATER ALARMS WERE LABELED.
Electrical › Electric Generation Source (service)
Issued 9 April 2002 Resolved
PROVIDE AMPERAGE METER FOR GENERATOR. LEGACY COMPONENT DESC: Panelboard
Due 4 May 2002
Resolved 8 April 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.