Records from 2003 to 2026. Most recent: inspection, 21 May 2026.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 February 2025
Resolved
"The emergency lighting... must automatically actuate upon failure of the main lighting system. If a vessel is not equipped with a single source of power for emergency lighting, it must have individual battery powered lights." Vessel's battery powered emergency lighting in the following locations was observed extinguished: Main Deck, 02 lights stbd side midships and fwd; 2 Deck, 01 light fwd center dining room; Bridge Deck, 01 light on bridge, 01 light in women's head, 01 light main stairwell, 01 light aft dining room. Replace batteries.
46 CFR 120.432(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2025
Resolution: Witnessed all E lights operational
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2025
Resolved
"Penetrations in A-Class fire control boundaries for electrical cables... must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated." Penetration in aft storage room did not have satisfactory insulation. Repair with new insulation.
46 CFR 116.415(a)(2)(ii)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2025
Resolution: Peneration filled with approved fire stop
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 February 2025
Resolved
"A door in a fire control boundary must meet the following requirements: double doors capable of independent operation and latching... if one door must always be closed first, means shall be provided to ensure that the doors close in the proper order." On the vessel's Bridge Deck, double leaf doors in main stairwell would not close in sequence for proper order. Provide proposal or repair to standard.
46 CFR 116.435(b)(5)(i)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Witnessed install of squencing bar and sat operation
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2025
Resolved
"A door in a bulkhead required to be A-60, A-30, or A-15 must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation." Door to machinery space was found with structural damage. Repair door.
46 CFR 116.435(c)(1)
46 CFR 116.435(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Door was fitted with a 4in X 4in 3/4in steel doubler over the gash. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 February 2025
Resolved
"Doors in A-Class fire control boundaries must meet the following additional requirements: a door must have a latch." Fire door centereed on Main Deck inboard of galley stairs was found with a broken latch. Repair to standard.
46 CFR 116.435(c)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: door was replaced with a new crash bar.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 February 2025
Resolved
"Gauges to indicate engine revolutions per minute (RPM)... must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station." Port main engine did not have RPM gauage. Provide gauge.
46 CFR 119.410(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: New gauge installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2025
Resolved
"A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system..." Foam extinguishing system in galley had unattached band clamp. Reattach band clamp.
46 CFR 118.425(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Wire securing device installed around ansel canister
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 February 2025
Resolved
"Each item of lifesaving equipment determined by the marine inspector to be not in serviceable condition must be repaired or replaced." 05 child lifejackets were found unserviceable on Main Deck. Replace 01 child lifejacket on Main Deck fwd.
46 CFR 115.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Child life jackets replaced to fufill the reqired number on the main deck
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 February 2025
Resolved
"An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail." Machinery guard on port main engine is loose. Machinery guard on stbd generator is missing. Repair port guard, install stbd generator.
46 CFR 116.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: new guards installed on both port and stbd generator and securing device for stbd ME guard was replaced with metal clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2025
Resolved
"Machinery and equipment on each vessel must be suitable for the vessel and its operation, and for the purpose intended." HVAC receive burst disk was found capped. Properly install the burst disk.
46 CFR 119.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Burst disk was re-assemblemed to the hose to overboard outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2025
Resolved
"Machinery and equipment on each vessel must be suitable for the vessel and its operation, and for the purpose intended." Bow thruster seal head tank was found leaking. Repair leak.
46 CFR 119.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Seal was replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 March 2024
Resolved
A system protecting a manned space must be fitted with a time delay and alarm of a type approved by the Commandant, arranged to require the alarm to sounds for at least 20 seconds or the time necessary to escape from space, whichever is greater, before the agent is released into the space. Alarms must be powered by extinguishing agent. The alarm for the CO2 fire extinguishing system was not operational. 46 CFR 118.410.(b)(9)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2024
Resolution: Operator submitted video of horn working. Pressure switch for CO2 sysem kills power ventilation, but was mislabled as "fire alarm." See no. 11 of the schematic in documents tab.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 March 2024
Resolved
Fire damper must be capable of manual operation from outside the space served, be fitted with an indicator showing whether the damper is open or closed, and be marked with red letters of at least 12.7 millimeters (0.5 inches) in height stating "VENTILATION FIRE DAMPER". Vessel was not found in compliance with any of the above requirements. Submit repair proposal within 7 days. 46 CFR 116.610(g)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2024
Resolved 26 March 2024
Resolution: It has been determined that the manual actuation of the CO2 system fufills the requirement for manual closure. The fusable link acts as automatic closure. Def cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information , specific to the vessel. Placard was noted missing. 46 CFR 121.506
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 18 March 2024
Resolution: Operator submitted template for radio distress calls
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
A vessel must carry either first aid kits approved series or a kit with equivalent contents and instructions. The first aid kits had expired medications. 46 CFR 121.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 26 March 2024
Resolution: Operator submitted photo of first aid kit supplies
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
Unless otherwise specified in this section, the vessel Security Officer must keep records of the activities as set out in paragraph (b) of this section for at least 2 years. The VSO did not have 2 years worth of security exercises kept on record. 33 CFR 104. 235(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 18 March 2024
Resolution: Exercise for 2024 was complete and added to vessel's record
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 March 2024
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the design requirements of the standards listed below for the hull material of the vessel. The port side main deck door located in the main parole was noted as being corroded, missing gasket material, and is not weather tight. Submit a repair proposal within 7 days. 46 CFR 116.300
Action required: 705 - Other - as specified
Due 13 March 2024
Resolved 2 May 2024
Resolution: Operator submitted photos of the repaired door.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
A self propelled vessel must meet the applicable requirements for main and auxiliary steering apparatus in subchapter F (Marine Engineering) and J (Electrical Engineering) of the chapter. The steering gear was missing safety pins. 46 CFR 119.600
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 26 March 2024
Resolution: Operator submitted photos of pins inserted into steering gear
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 May 2023
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated.
The A-60 boundary in the engine room had 2 cable
penetrations on the port side that were found open.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 May 2023
Resolution: Penetration ports were properly closed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2023
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. 02 ring buoys were rendered out-of-service due to cracking and and penetrations in the buoyant material.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2023
Resolution: Operator installed new buoys.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 May 2023
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type that is installed in accordance with part 76 in subchapter H of this chapter: A space containing propulsion machinery. Vessel was unable to demonstrate operation of heat detection alarm in the machinery space at the time of inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 May 2023
Resolution: Heat detection alarm in machinery space operated as required.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2023
Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. Galley ventilation duct does not have damper or vent closure. Rectify within 6 months.
Action required: 705 - Other - as specified
Resolved 17 April 2024
Resolution: Rectified by activity #7874794 - duct is not for ventilation, but exhaust and is therefore not required to have damper closure. Exhaust fan shut-off tested satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel found to have drainage pipe corroded and leaking on port side of engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Main deck power panels 1-3 and the power panels in the pump room must be properly labeled with each breaker’s service.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2023
Resolution: Operator marked electrical panel as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 May 2023
Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. Stbd generator missing lagging on exhaust
duct.
Action required: 705 - Other - as specified
Resolved 26 May 2023
Resolution: Stbd exhaust lagging was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical receptacle in laz missing cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2023
Resolution: Electrical cover in laz was installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 May 2023
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device:...(iii) A self-propelled vessel that is certificated to carry more than 150 passengers. AIS not transmitted properly.
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2023
Resolved
Ducts serving cargo spaces, machinery spaces, or vehicles spaces must be fitted with automatic fire dampers. Automatic closure of fire damper was unable to be tested at the time of the inspection.
26MAY23 As per OCMI vessel is allowed to sail once earliest arrangments are made to have maintance compoany attend to test dampners. SeaSafety is scheduled to attend 30MAY.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2023
Resolved
Fire dampers must be capable of manual operation from outside the space served, be fitted with an indicator showing whether the damper is open or closed, and be marked with red letters of at least 12.7 millimeters (0.5 inches) in height stating “VENTILATION FIRE DAMPER”
vessel was not found in compliance with any of the above
requirements. Rectify within 6 months.
Action required: 705 - Other - as specified
Resolved 17 April 2024
Resolution: Resolved - see def no. 2 in activity #7874794
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 May 2023
Resolved
A door must be of the self-closing type capable of closing against a 3.5 list of the vessel. Fire door on main deck, inboard entrance to the galley did not close fully.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2023
Resolution: Door satisfactorily closed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 March 2022
Resolved
46 CFR 116.435(c)(6)(i)
A door must be of the self closing type capable of closing against a 3.5 list of the vessel;
Action required: 10 - Deficiency Rectified
Due 18 March 2022
Resolved 18 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2020
Resolved
Exhaust in the lazarette prevented inspection of the space. Submit causal analysis and repair report prior to the carriage of passengers. 46 CFR 119.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2020
Resolution: Due to COVID-19, Accepted operator statement to clear deficiencies
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2020
Resolved
Raw water on the port main engine transmission cooler is leaking and must be repaired. Submit causal analysis and repair report within 14 days. 46 CFR 119.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 22 April 2020
Resolution: Due to COVID-19, Accepted operator statement to clear deficiencies
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 February 2020
Resolved
A garbage management plan must be in writing. Develop and make available on board a garbage management plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2020
Resolved 26 February 2020
Resolution: Vessel submitted plan via e-mail.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 February 2020
Resolved
Company drug policy must be in writing and posted aboard the vessel in an area accessible to the crew. The company policy statement should clearly identify the company’s position regarding substance abuse and describe the actions that will occur if the policy is violated. Develop and post a policy. 46 CFR 16.201
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2020
Resolved 26 February 2020
Resolution: Vessel submitted policy via e-mail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019
Resolved
Generators unable to evidence proof of reverse power relay. Deficiency changed to 701 due to passing 2 week expiration date with no extension request submitted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 2 May 2019
Resolution: proved reverse power relay.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019
Resolved
Child PFD's not segregated and labeled at each storage station.
Deficiency changed to 701 due to passing 2 week expiration date with no extension request submitted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 2 May 2019
Resolution: segregated to satisfaction of mi
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 September 2018
Resolved
Vsl is broadcasting greater than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 May 2023
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 30 March 2017
Resolved
Vessel's port main threw a rod during start up.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2017
Resolution: Witnessed satisfactory sea trials.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 24 February 2016
Resolved
Port ME leaking coolant JW on FWD side of engine, also leaking oil on aft side of the engine. 46 CFR 115.830
Condition: Improper/Lack of Maintenance
Due 9 March 2016
Resolved 4 March 2016
Resolution: Attended vessel ran ME for 10 min noticed no leaks. operator provided tech report verifying engine repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 24 February 2016
Resolved
STBD ME leaking oil out of exhaust manifold. 46 CFR 115.830
Condition: Improper/Lack of Maintenance
Due 9 March 2016
Resolved 4 March 2016
Resolution: Attended vessel ran ME for 10 min noticed no leaks. operator provided tech report verifying engine repairs.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 24 February 2016
Resolved
Missing one circuit breaker leaving open slot in panel, breaker panel door does not securley latch closed.
Condition: Improper Installation
Due 2 March 2016
Resolved 4 March 2016
Resolution: Attended vessel, verified slot has been properly closed and panel door properly latches closed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 February 2016
Resolved
Multiple lights on various decks do not automatically come one when power is cut from SSDG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2016
Resolution: Attended vessel verified all light properly functioning.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 February 2016
Resolved
Manual call points throughout the vessel do not funtion as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2016
Resolution: Attended vessel, found call points to be funtioning properly. Fire service tech attended vessel and found a disconected wire within the system, all call points down from there didn not alarm in the pilot house.