Records from 2000 to 2026. Most recent: inspection, 21 May 2026.
Inspection history · 59
21 May 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8377423
21 June 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8163890
6 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8105876
24 February 2025
Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8080944
6 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7907203
6 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7874794
24 May 2023
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7695817
7 April 2023
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7663905
18 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7414040
30 November 2021
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7359526
19 May 2021
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7201399
7 May 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7191474
25 February 2020
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6915086
22 May 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6690695
16 April 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6663200
27 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6549845
21 December 2017
COI Inspection · Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6327422
25 August 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6251212
30 March 2017
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6115149
10 March 2017
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6103605
19 June 2016
Type not recorded
No type recorded · Station Washington DC · USCG East District (CGD-E) · Activity 5912423
24 February 2016
MTSA Verification · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5822715
10 February 2016
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5822686
2 November 2015
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5755484
29 October 2015
Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5770940
18 June 2014
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4893233
21 February 2012
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4251657
7 December 2011
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4203740
8 February 2011
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3942234
18 October 2010
Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3877307
2 March 2010
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3661832
25 April 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3462058
3 March 2009
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3427568
31 January 2009
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3403863
31 January 2009
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3411504
15 December 2008
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3380139
19 March 2008
Examination of Repairs
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3181457
6 February 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3146369
6 February 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3093562
22 February 2006
MTSA Verification · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2589706
31 January 2006
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2576740
6 September 2005
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2485271
3 March 2005
COI Inspection · MARPOL Annex V Examination · Security Plan Review - ASP
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2302655
13 August 2004
MTSA Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2164937
2 June 2004
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2085920
5 April 2004
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2037518
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1979350
27 May 2003
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1802374
20 May 2003
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1797361
20 May 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1797838
17 May 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1796390
3 June 2002
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1626515
29 March 2002
Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1599134
16 May 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1450635
26 January 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1376450
11 July 2000
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1051443
23 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 172071
10 March 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1465540
3 March 2000
Inclining Experiment · Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1465536
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 February 2025
Resolved
"The emergency lighting... must automatically actuate upon failure of the main lighting system. If a vessel is not equipped with a single source of power for emergency lighting, it must have individual battery powered lights." Vessel's battery powered emergency lighting in the following locations was observed extinguished: Main Deck, 02 lights stbd side midships and fwd; 2 Deck, 01 light fwd center dining room; Bridge Deck, 01 light on bridge, 01 light in women's head, 01 light main stairwell, 01 light aft dining room. Replace batteries.
46 CFR 120.432(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2025
Resolution: Witnessed all E lights operational
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2025
Resolved
"Penetrations in A-Class fire control boundaries for electrical cables... must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated." Penetration in aft storage room did not have satisfactory insulation. Repair with new insulation.
46 CFR 116.415(a)(2)(ii)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2025
Resolution: Peneration filled with approved fire stop
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 February 2025
Resolved
"A door in a fire control boundary must meet the following requirements: double doors capable of independent operation and latching... if one door must always be closed first, means shall be provided to ensure that the doors close in the proper order." On the vessel's Bridge Deck, double leaf doors in main stairwell would not close in sequence for proper order. Provide proposal or repair to standard.
46 CFR 116.435(b)(5)(i)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Witnessed install of squencing bar and sat operation
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 February 2025
Resolved
"A door in a bulkhead required to be A-60, A-30, or A-15 must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation." Door to machinery space was found with structural damage. Repair door.
46 CFR 116.435(c)(1)
46 CFR 116.435(c)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Door was fitted with a 4in X 4in 3/4in steel doubler over the gash. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 February 2025
Resolved
"Doors in A-Class fire control boundaries must meet the following additional requirements: a door must have a latch." Fire door centereed on Main Deck inboard of galley stairs was found with a broken latch. Repair to standard.
46 CFR 116.435(c)(3)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: door was replaced with a new crash bar.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 February 2025
Resolved
"Gauges to indicate engine revolutions per minute (RPM)... must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station." Port main engine did not have RPM gauage. Provide gauge.
46 CFR 119.410(b)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: New gauge installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 February 2025
Resolved
"A grease extraction hood must be equipped with a dry or wet chemical fire extinguishing system..." Foam extinguishing system in galley had unattached band clamp. Reattach band clamp.
46 CFR 118.425(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Wire securing device installed around ansel canister
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 February 2025
Resolved
"Each item of lifesaving equipment determined by the marine inspector to be not in serviceable condition must be repaired or replaced." 05 child lifejackets were found unserviceable on Main Deck. Replace 01 child lifejacket on Main Deck fwd.
46 CFR 115.808(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Child life jackets replaced to fufill the reqired number on the main deck
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 February 2025
Resolved
"An exposed hazard, such as gears or rotating machinery, must be protected by a cover, guard, or rail." Machinery guard on port main engine is loose. Machinery guard on stbd generator is missing. Repair port guard, install stbd generator.
46 CFR 116.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: new guards installed on both port and stbd generator and securing device for stbd ME guard was replaced with metal clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2025
Resolved
"Machinery and equipment on each vessel must be suitable for the vessel and its operation, and for the purpose intended." HVAC receive burst disk was found capped. Properly install the burst disk.
46 CFR 119.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Burst disk was re-assemblemed to the hose to overboard outlet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 February 2025
Resolved
"Machinery and equipment on each vessel must be suitable for the vessel and its operation, and for the purpose intended." Bow thruster seal head tank was found leaking. Repair leak.
46 CFR 119.100
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2025
Resolved 6 March 2025
Resolution: Seal was replaced. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 March 2024
Resolved
A system protecting a manned space must be fitted with a time delay and alarm of a type approved by the Commandant, arranged to require the alarm to sounds for at least 20 seconds or the time necessary to escape from space, whichever is greater, before the agent is released into the space. Alarms must be powered by extinguishing agent. The alarm for the CO2 fire extinguishing system was not operational. 46 CFR 118.410.(b)(9)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2024
Resolution: Operator submitted video of horn working. Pressure switch for CO2 sysem kills power ventilation, but was mislabled as "fire alarm." See no. 11 of the schematic in documents tab.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 6 March 2024
Resolved
Fire damper must be capable of manual operation from outside the space served, be fitted with an indicator showing whether the damper is open or closed, and be marked with red letters of at least 12.7 millimeters (0.5 inches) in height stating "VENTILATION FIRE DAMPER". Vessel was not found in compliance with any of the above requirements. Submit repair proposal within 7 days. 46 CFR 116.610(g)(4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2024
Resolved 26 March 2024
Resolution: It has been determined that the manual actuation of the CO2 system fufills the requirement for manual closure. The fusable link acts as automatic closure. Def cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information , specific to the vessel. Placard was noted missing. 46 CFR 121.506
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 18 March 2024
Resolution: Operator submitted template for radio distress calls
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
A vessel must carry either first aid kits approved series or a kit with equivalent contents and instructions. The first aid kits had expired medications. 46 CFR 121.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 26 March 2024
Resolution: Operator submitted photo of first aid kit supplies
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
Unless otherwise specified in this section, the vessel Security Officer must keep records of the activities as set out in paragraph (b) of this section for at least 2 years. The VSO did not have 2 years worth of security exercises kept on record. 33 CFR 104. 235(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 18 March 2024
Resolution: Exercise for 2024 was complete and added to vessel's record
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 6 March 2024
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the design requirements of the standards listed below for the hull material of the vessel. The port side main deck door located in the main parole was noted as being corroded, missing gasket material, and is not weather tight. Submit a repair proposal within 7 days. 46 CFR 116.300
Action required: 705 - Other - as specified
Due 13 March 2024
Resolved 2 May 2024
Resolution: Operator submitted photos of the repaired door.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 March 2024
Resolved
A self propelled vessel must meet the applicable requirements for main and auxiliary steering apparatus in subchapter F (Marine Engineering) and J (Electrical Engineering) of the chapter. The steering gear was missing safety pins. 46 CFR 119.600
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2024
Resolved 26 March 2024
Resolution: Operator submitted photos of pins inserted into steering gear
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 May 2023
Resolved
Penetrations in A-Class fire control boundaries for electrical cables, pipes, trunks, ducts, etc. must be constructed to prevent the passage of flame and smoke for one hour. In addition, the penetration must be designed or insulated so that it will withstand the same temperature rise limits as the boundary penetrated.
The A-60 boundary in the engine room had 2 cable
penetrations on the port side that were found open.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 May 2023
Resolution: Penetration ports were properly closed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2023
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. 02 ring buoys were rendered out-of-service due to cracking and and penetrations in the buoyant material.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2023
Resolution: Operator installed new buoys.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 May 2023
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type that is installed in accordance with part 76 in subchapter H of this chapter: A space containing propulsion machinery. Vessel was unable to demonstrate operation of heat detection alarm in the machinery space at the time of inspection.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 May 2023
Resolution: Heat detection alarm in machinery space operated as required.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2023
Resolved
Suitable means, such as a manual damper, automatic damper, or vent cover, must be provided in an accessible location outside the space served by the ventilation duct for shutting off the passage of air through the ventilation duct in the event of fire. Galley ventilation duct does not have damper or vent closure. Rectify within 6 months.
Action required: 705 - Other - as specified
Resolved 17 April 2024
Resolution: Rectified by activity #7874794 - duct is not for ventilation, but exhaust and is therefore not required to have damper closure. Exhaust fan shut-off tested satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2023
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel found to have drainage pipe corroded and leaking on port side of engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency conditions. Main deck power panels 1-3 and the power panels in the pump room must be properly labeled with each breaker’s service.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2023
Resolution: Operator marked electrical panel as required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 May 2023
Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. Stbd generator missing lagging on exhaust
duct.
Action required: 705 - Other - as specified
Resolved 26 May 2023
Resolution: Stbd exhaust lagging was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Electrical receptacle in laz missing cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 May 2023
Resolution: Electrical cover in laz was installed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 May 2023
Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device:...(iii) A self-propelled vessel that is certificated to carry more than 150 passengers. AIS not transmitted properly.
Action required: 10 - Deficiency Rectified
Resolved 24 May 2023
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2023
Resolved
Ducts serving cargo spaces, machinery spaces, or vehicles spaces must be fitted with automatic fire dampers. Automatic closure of fire damper was unable to be tested at the time of the inspection.
26MAY23 As per OCMI vessel is allowed to sail once earliest arrangments are made to have maintance compoany attend to test dampners. SeaSafety is scheduled to attend 30MAY.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2023
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 May 2023
Resolved
Fire dampers must be capable of manual operation from outside the space served, be fitted with an indicator showing whether the damper is open or closed, and be marked with red letters of at least 12.7 millimeters (0.5 inches) in height stating “VENTILATION FIRE DAMPER”
vessel was not found in compliance with any of the above
requirements. Rectify within 6 months.
Action required: 705 - Other - as specified
Resolved 17 April 2024
Resolution: Resolved - see def no. 2 in activity #7874794
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 May 2023
Resolved
A door must be of the self-closing type capable of closing against a 3.5 list of the vessel. Fire door on main deck, inboard entrance to the galley did not close fully.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2023
Resolution: Door satisfactorily closed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 March 2022
Resolved
46 CFR 116.435(c)(6)(i)
A door must be of the self closing type capable of closing against a 3.5 list of the vessel;
Action required: 10 - Deficiency Rectified
Due 18 March 2022
Resolved 18 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2020
Resolved
Exhaust in the lazarette prevented inspection of the space. Submit causal analysis and repair report prior to the carriage of passengers. 46 CFR 119.430
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2020
Resolution: Due to COVID-19, Accepted operator statement to clear deficiencies
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2020
Resolved
Raw water on the port main engine transmission cooler is leaking and must be repaired. Submit causal analysis and repair report within 14 days. 46 CFR 119.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2020
Resolved 22 April 2020
Resolution: Due to COVID-19, Accepted operator statement to clear deficiencies
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 February 2020
Resolved
A garbage management plan must be in writing. Develop and make available on board a garbage management plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2020
Resolved 26 February 2020
Resolution: Vessel submitted plan via e-mail.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 February 2020
Resolved
Company drug policy must be in writing and posted aboard the vessel in an area accessible to the crew. The company policy statement should clearly identify the company’s position regarding substance abuse and describe the actions that will occur if the policy is violated. Develop and post a policy. 46 CFR 16.201
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2020
Resolved 26 February 2020
Resolution: Vessel submitted policy via e-mail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 April 2019
Resolved
Generators unable to evidence proof of reverse power relay. Deficiency changed to 701 due to passing 2 week expiration date with no extension request submitted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 2 May 2019
Resolution: proved reverse power relay.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2019
Resolved
Child PFD's not segregated and labeled at each storage station.
Deficiency changed to 701 due to passing 2 week expiration date with no extension request submitted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 2 May 2019
Resolution: segregated to satisfaction of mi
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 September 2018
Resolved
Vsl is broadcasting greater than expected vessel length
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 24 May 2023
Engineering › Diesel Engine (propulsion-reduction gear) › Connecting Rod
Issued 30 March 2017
Resolved
Vessel's port main threw a rod during start up.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2017
Resolution: Witnessed satisfactory sea trials.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 24 February 2016
Resolved
Port ME leaking coolant JW on FWD side of engine, also leaking oil on aft side of the engine. 46 CFR 115.830
Condition: Improper/Lack of Maintenance
Due 9 March 2016
Resolved 4 March 2016
Resolution: Attended vessel ran ME for 10 min noticed no leaks. operator provided tech report verifying engine repairs.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 24 February 2016
Resolved
STBD ME leaking oil out of exhaust manifold. 46 CFR 115.830
Condition: Improper/Lack of Maintenance
Due 9 March 2016
Resolved 4 March 2016
Resolution: Attended vessel ran ME for 10 min noticed no leaks. operator provided tech report verifying engine repairs.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 24 February 2016
Resolved
Missing one circuit breaker leaving open slot in panel, breaker panel door does not securley latch closed.
Condition: Improper Installation
Due 2 March 2016
Resolved 4 March 2016
Resolution: Attended vessel, verified slot has been properly closed and panel door properly latches closed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 February 2016
Resolved
Multiple lights on various decks do not automatically come one when power is cut from SSDG.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2016
Resolution: Attended vessel verified all light properly functioning.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 February 2016
Resolved
Manual call points throughout the vessel do not funtion as designed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2016
Resolution: Attended vessel, found call points to be funtioning properly. Fire service tech attended vessel and found a disconected wire within the system, all call points down from there didn not alarm in the pilot house.
Electrical › Electric Generation Source (service) › Generator
Issued 19 November 2015
Resolved
Provide temprature readings of engine room during summer months while vessel is underway operating under normal conditions to determine if installed generators rated at 40 degree C will need to be derated to accommodate for ambient engine room temperature.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 10 March 2017
Resolution: Attended vessel and cleared above deficiency. Vessel is derated and now has 50 degree C rating.
Electrical › Electric Supply System (service) › Cable
Issued 19 November 2015
Resolved
Provide protected metal coverings or other suitable means to enclose port and starboard generator bus tie cable connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2015
Resolved 21 December 2015
Resolution: Inspected istallation of protective metal enclosure to provide shock protection on both port and starboard generator fedder cables.
Electrical › Electric Generation Source (service) › Generator
Issued 29 October 2015
Resolved
Prove proper opertion of starbaord generator after overspeed condion, which resulted in destruction of generator, prior to operation of vessel. IAW 46CFR120.310(a)(1)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 November 2015
Resolution: Witnessed satisfactory test of new starboard generator.
Fire Fighting › Ventilation Systems › Fans
Issued 21 February 2012
Resolved
Vessel galley ventilation shutdown inoperable, prove proper operation to the satisfaction of Coast Guard Marine Inspector.
Due 21 March 2012
Resolved 27 March 2012
Resolution: Ventialltion shut down fixed to the satisfaction of the CG marine inspector.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 21 February 2012
Resolved
Vessel emergency lighting in the vicinity of the starboard entry/exit door on the second deck is inoperable, prove proper operation to the Coast Guard.
Due 21 March 2012
Resolved 27 March 2012
Resolution: Emergency light fixture installed and operational to the satisfaction of the CG marine inspector.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 2 March 2010
Resolved
Heat detector in galley hanging loose. Also, heat detectors in galley hadn't been annually tested.
Condition: Improper/Lack of Maintenance
Due 2 April 2010
Resolved 5 March 2010
Resolution: Heat detector in galley secured and heat detectors annually tested.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 March 2010
Resolved
Dead end wires from gauges above both main engines. Secure/remove as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2010
Resolved 5 March 2010
Resolution: Dead end wires above main engines secured as appropriate.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2009
Resolved
Vessel had an allision w/ D.C Fire Boat [name withheld] Jr. Spirit of Washington collided w/ the stbd external hull structure resulting in a 11.0' x 11.5" gash in the hull approximately 3.5' above the waterline. Vessel will have permanent repairs done @ General Shipyard on02/02/2009. SecBalt will follow up on 02/05/2009 @ General Shipyard
Action required: 705 - Other - as specified
Due 5 February 2009
Resolved 12 February 2009
Resolution: [name withheld], provided digital pictures detailing the proper repair of the accommodation railing located on the starboard quarter of the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 19 March 2008
Resolved
Vessel reported that the engine temp has risen to 250 degrees and the collant was pushing out the inboard exhaust manifold on 03/19/2008. Vessel rep ([name withheld]) filed a CG 2692 and reported the marine casualty to SecBalt. SecBalt will continue to follow and provide construction oversight for the proposed repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2008
Resolution: Vessel rep and crew performed a complete frame overhaul of the engine to include new cylinder heads, cylinder kits, tune up, full engine checks and sea trials. Marine inspectors cleared outstanding deficiencies and cleared the vessel for underway trips.
Construction/Loadline › Structures › Deck Plating
Issued 6 February 2008
Resolved
Replace deck plating 2' by 2' in the forward galley
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 22 February 2008
Resolution: Vessel owner successfully completed repairs to the 2'' x 2'' deck plating in the galley. Pictures of the work will be placed in vessel''s current file.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 6 February 2008
Resolved
Calibrate rudder angle indicactor in steerage compartment.
Action required: 705 - Other - as specified
Due 1 March 2008
Resolved 22 February 2008
Resolution: Vessel owner ordered a Rudder Angle Indicator model 51 RAI to replace the non-functional device. An invoice of the part and subsequent work will be placed in current vessel file.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 February 2006
Resolved
Repair or replace piece of structural fir protection in engine room directly above engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2006
Resolved 28 February 2006
Resolution: Maintenance crew repaired prior to our departure.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 22 February 2006
Resolved
Provide proof of a properly functioning rudder angle indicator.
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 6 March 2006
Resolution: Company had vendor calibrate system and it is reading correctly.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 22 February 2006
Resolved
Provide proof of repair to hand grab rail leading to galley.
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 9 March 2006
Resolution: Company repaired broken hand grab rail.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 22 February 2006
Resolved
Replace main shaft seal on fire pump.
Action required: 705 - Other - as specified
Due 9 March 2006
Resolved 14 March 2006
Resolution: Company replaced pump seal.
Engineering › Sea-water System (primary cooling) › Valve
Issued 6 September 2005
Resolved
Replace valve 3" raw water intake valve for the AC in the galley.
Action required: 705 - Other - as specified
Due 6 September 2005
Resolved 21 October 2005
Documentation › Markings/Placards › Capacity Marking
Issued 6 September 2005
Resolved
Label upper deck for number of passengers at ladder.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 21 October 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 6 September 2005
Resolved
Renew/reconnect fresh water wash-down piping to upperdeck.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 21 October 2005
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 6 September 2005
Resolved
Repair elevator, not working at time of inspection.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 21 October 2005
Engineering › Bilge Water Management System › Piping
Issued 6 September 2005
Resolved
Repair leak in floor drain pipe located in rudder space.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 21 October 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 September 2005
Resolved
Chip out & renew ramp to Port side aft door, check out & coat steel underneath.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 21 October 2005
Documentation › Certificates/Documents › FCC SSL
Issued 6 September 2005
Resolved
Provide on board a valid FCC station license.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2005
Resolved 21 October 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 6 September 2005
Resolved
Repair high level alarms. WTD and bilge alarm indicators on bridge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2005
Resolved 21 October 2005
Engineering › Steering Gear System › Pump
Issued 6 September 2005
Resolved
Repair steering pump operation indicator on bridge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2005
Resolved 21 October 2005
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 6 September 2005
Resolved
Repair and verify rudder angle indicators on bridge and in steering compartment are in alignment with rudder angle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2005
Resolved 21 October 2005
Engineering › Steering Gear System › Valve, Control
Issued 6 September 2005
Resolved
Repair steering controllers on bridge and bridgewings.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2005
Resolved 21 October 2005
Communications › Audible Communications › SPD (Other)
Issued 6 September 2005
Resolved
Repair PA system throughout the ship.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2005
Resolved 21 October 2005
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 6 September 2005
Resolved
Port shaft seal leaking, repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2005
Resolved 21 October 2005
Engineering › Steering Gear System › Pump
Issued 6 September 2005
Resolved
Repair #2 steering pump. Pump only works in local operation and not remote. Must work from steering station.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 2 November 2005
Communications › Alarms/Indicators › High Water Alarm
Issued 6 September 2005
Resolved
Repair high level alarm in bilge below galley area.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 2 November 2005
Engineering › Bilge Water Management System › Not Operational
Issued 3 March 2005
Resolved
Vessel must demonstrate the proper operation of all high level bilge visual and audible alarms. Vessel may operate with an additional deckhand assigned strictly to conduct rounds on monitored voids until permanent repairs can be made.
Due 11 March 2005
Resolved 1 June 2005
Resolution: Completed Same/Op Chk. Sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 March 2005
Resolved
Vessel must replace the burned out circuit boards in the wheelhouse and the galley.
Due 11 March 2005
Resolved 1 June 2005
Resolution: Replaced Same/ Both Positions.
Communications › Radio Communications › EPIRB
Issued 3 March 2005
Resolved
Vessel must replace the expired hydrostatic release for the EPIRB. Vessel is restricted to operations within 3 NM of shore until this deficiency is cleared.
Due 11 March 2005
Resolved 31 March 2005
Resolution: Vessel owner replaced expired hydrostatic release for the EPIRB.
Communications › Radio Communications › EPIRB
Issued 3 March 2005
Resolved
Vessel must replace the expired EPIRB battery.
Due 11 March 2005
Resolved 31 March 2005
Resolution: Vessel owner replaced expired EPIRB battery.
Accommodation/Occupational Safety › Potable Water System › General
Issued 3 March 2005
Resolved
Vessel must replace the rubber patch on the pressurized water copper piping, port side aft of the galley.
Due 18 March 2005
Resolved 31 March 2005
Resolution: Vessel owner removed the rubber patch and replaced with properly sized copper pipe.
Documentation › Certificates/Documents › FCC SSL
Issued 3 March 2005
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 11 March 2005
Resolved 4 March 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 March 2005
Resolved
Vessel must repair the cracked head floor washdown piping in the lazarette starboard side of ladder.
Due 18 March 2005
Resolved 31 March 2005
Resolution: Vessel owner replaced cracked washdown piping with new pipe.
Construction/Loadline › Structures › Superstructure
Issued 3 March 2005
Resolved
Vessel must replace the missing window in the #3 starboard side below deck.
Due 18 March 2005
Resolved 5 May 2005
Resolution: New window installed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Governor
Issued 2 June 2004
Resolved
Prove proper operation of regulated oil PSI sensing unit on port engine.
Due 9 June 2004
Resolved 23 June 2004
Lifesaving › Lifejacket/PFD (General)
Issued 2 June 2004
Resolved
Provide 2 additional child PFDs as per COI.
Due 9 June 2004
Resolved 7 June 2004
Accommodation/Occupational Safety › Medical/First Aid
Issued 2 June 2004
Resolved
Provide CG approved or equivalent first aid kits.
Due 9 June 2004
Resolved 7 June 2004
Engineering › Diesel Engine (propulsion-direct drive) › Valve, Check (air start)
Issued 2 June 2004
Resolved
Replace missing air intake breathers on stbd main engine.
Due 9 June 2004
Resolved 23 June 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 27 May 2003
Resolved
Secure electrical outlet box iwo aft galley wtd.
Due 3 June 2003
Resolved 28 May 2003
Resolution: Outlet box secured properly.
Electrical › Electric Supply System (service) › Cable
Issued 27 May 2003
Resolved
Replace damaged power cord on port side beer cooler.
Due 3 June 2003
Resolved 29 June 2003
Resolution: Beer cooler power cord replaced.
Engineering › Fuel Oil Service System
Issued 27 May 2003
Resolved
Repair leaks on P/S MDE and P/S generator fuel oil strainers. LEGACY COMPONENT DESC: fuel supply system
Due 27 May 2003
Resolved 27 May 2003
Resolution: It was determined oil in flame impingement bowls was from recent maintenance. Leaks corrected.
Fire Fighting › Structural - A Class Divisions
Issued 27 May 2003
Resolved
Repair 20 fire screen doors that did not close properly due to inop closure devices/hardware. LEGACY COMPONENT DESC: Openings - Fire Doors
Due 27 May 2003
Resolved 29 May 2003
Resolution: Place 3 additional crew on board as fire watch until all fire screeen doors were repaired on 29MAY03.
Fire Fighting › Combustible Materials
Issued 27 May 2003
Resolved
Prove installed curtains fwd meet NFPA 701 standard. LEGACY COMPONENT DESC: Linings
Due 3 June 2003
Resolved 3 June 2003
Resolution: Curtains removed.
Fire Fighting › Combustible Materials
Issued 27 May 2003
Resolved
Remove cardboard boxes iwo galley access. LEGACY COMPONENT DESC: trash/cardboard boxes
Due 27 May 2003
Resolved 27 May 2003
Resolution: Boxes removed.
Documentation › Manuals/Policy Documentation
Issued 27 May 2003
Resolved
Missing current Light List/Tidal Current Tables. LEGACY COMPONENT DESC: Light List/Tidal Current Tables
Due 27 May 2003
Resolved 27 May 2003
Resolution: Pubs placed onboard.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 May 2003
Resolved
Broken window stbd midship access.
Due 3 June 2003
Resolved 29 May 2003
Resolution: Broken window replaced.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 27 May 2003
Resolved
Storm rail missing from galley griddle
Due 3 June 2003
Resolved 28 May 2003
Resolution: Storm rail installed on griddle.
Accommodation/Occupational Safety › Occupational Safety
Issued 27 May 2003
Resolved
Remove debris from galley store room bilge. LEGACY COMPONENT DESC: debris in bilge
Due 27 May 2003
Resolved 27 May 2003
Resolution: Debris removed.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 20 May 2003
Resolved
Pistons on stbd MDE damaged when water intruded through exhaust. LEGACY COMPONENT DESC: Piston Rod
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2003
Resolved 21 May 2003
Resolution: Observed satisfactory test, fwd and astern, of the stbd MDE.
Construction/Loadline › Structures
Issued 17 May 2003
Resolved
Forward port side main deck passenger cabin window broken out after allision with Rye Playland pier after heavy weather parted vessels mooring lines. This to be corercted/replaced prior to carrying passengers. LEGACY COMPONENT DESC: Superstructure
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 May 2003
Resolved 21 May 2003
Resolution: Observed satisfactory installation of new window. Witnessed satisfactory water test. No leakage observed.
Communications › Radio Communications › EPIRB
Issued 3 June 2002
Resolved
Renew hyrdrostatic release for EPIRB (Vessel restricted to voyages w/in 3 miles from shore until corrected).
Due 17 June 2002
Resolved 4 June 2002
Resolution: Observed newly installed hydrostatic release.
Communications › Radio Communications
Issued 3 June 2002
Resolved
Ensure NOAA registration sticker attached to EPIRB (Vessel restricted to voyages w/in 3 miles from shore until corrected). LEGACY COMPONENT DESC: EPIRB
Due 17 June 2002
Resolved 10 June 2002
Resolution: Received proof of NOAA registration for EPIRB (fax) from [name withheld].
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 June 2002
Resolved
Prove proper operation of magnetic compass light.
Due 10 June 2002
Resolved 4 June 2002
Resolution: Observed newly installed and operable light.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 3 June 2002
Resolved
Install blank to dishwasher distribution panel.
Due 10 June 2002
Resolved 3 June 2002
Resolution: Corrected prior to my departure.
Fire Fighting › Grease Extraction Hood
Issued 3 June 2002
Resolved
Install grease extraction hood above the 2 griddles in galley.
Due 3 July 2002
Resolved 16 July 2002
Resolution: Fixed fire extinguishing system is installed for galley.
Operations/Management › Equipment Service/Testing
Issued 3 June 2002
Resolved
Provide servicing report for fixed fire fighting extinguishing system. LEGACY COMPONENT DESC: Fixed CO2 system
Due 6 June 2002
Resolved 4 June 2002
Resolution: Received servicing report completed by Sea Safety International.
Personnel › Manning/Qualifications
Issued 3 June 2002
Resolved
Provide copy of written senior deckhand in lieu of licensed mate designation letter. LEGACY COMPONENT DESC: Senior Deckhand Designation Letter
Due 10 June 2002
Resolved 4 June 2002
Resolution: Observed designation letter.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 3 June 2002
Resolved
Prove proper operation of port/stbd generator overspeed trips w/ tachometer. LEGACY COMPONENT DESC: Overspeed
Due 10 June 2002
Resolved 3 June 2002
Resolution: Witnessed prior to my departure.
Engineering
Issued 16 May 2001
Resolved
Renew RPM guages (tachometers) on the bridge for both MDE's.
Condition: Unknown
Due 16 June 2001
Resolved 9 July 2001
Fire Fighting
Issued 16 May 2001
Resolved
Make repairs to fire door latches on engine room door and on upper fire tower door.
Condition: Unknown
Due 23 May 2001
Resolved 20 June 2001
Electrical
Issued 16 May 2001
Resolved
Provide ground fault circuit breaker or outlets in wet kitchen near sinks and steam tables.
Condition: Unknown
Due 23 May 2001
Resolved 20 June 2001
Accommodation/Occupational Safety
Issued 26 January 2001
Resolved
Install holdback devices for all emergency escape scuttles.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Accommodation/Occupational Safety
Issued 26 January 2001
Resolved
NY04 from reference case MI00008592 is extended to 26Feb01.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Accommodation/Occupational Safety
Issued 10 March 2000
Resolved
PROVIDE PLANS FOR INSTALLATIONS OF PROPER EMERGENCY ESCAPE HATCH AND ACCESSTO SAID HATCH IN/FROM GALLEY STORAGE COMPARTMENT IN ACCORDANCE WITH 46 CFR[phone withheld] EDITION. IN INTERIM, PROVIDE SIGN ON COMPARTMENT DOOR LIMITING ACCESS WHILE UNDERWAY AND NOTING THE LACK OF EMERGENCY HATCH.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 10 March 2000
Resolved
Remove carpet from under all fire doors and provide a proper door jam in accordance with 46 CFR 116.435(c)(5) 1999 edition.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 10 March 2000
Resolved
Provide a fire suppression system for the galley hood in accordance with 46CFR 118.400(d) 1999 edition and with 46 CFR 118.425(b) 1999 edition
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 10 March 2000
Resolved
PROVIDE SEPARATE STORAGE OF CHILD LIFE JACKET INDEPENDENT OF ADULT LIFE JACKETS AND LABELED AS SUCH.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Lifesaving
Issued 10 March 2000
Resolved
PROVIDE AN ADDITIONAL USCG APPROVED LIFE RING ON THE PORT SIDE AFT ON 3 DECK.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Navigation
Issued 10 March 2000
Resolved
PROVIDE A 406MHZ EPIRB, ROUTE IS LIMITED TO LAKES BAY AND SOUNDS UNTIL EPIRB IS PROVIDE IN ACCORDANCE WITH 46 CFR 117.200 (TABLE 117.200) LIMITED COAST WISE (B)(III)(B).
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Deck/Cargo
Issued 10 March 2000
Resolved
PROVE PROPER OPERATION OF THE GROUND TACKLE (ANCHORING) WITH NORMAL CREW AS PROVIDED FOR IN THE CREW'S STATION BILL.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Lifesaving
Issued 10 March 2000
Resolved
PROVIDE SIGN LIMITING PASSENGER ACCESS TO BRIDGE AREA AND PILOTHOUSE. PLACE SIGNS JUST FORWARD OF LIFE JACKET LOCKERS AND ENSURE LOCKERS REMAIN ACCESSIBLE.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Fire Fighting
Issued 10 March 2000
Resolved
Provide sequencer for double doors on third deck, ensure independent operation, proper door jam and that all other applicable requirements of 46CFR [phone withheld] edition are meet.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Lifesaving
Issued 10 March 2000
Resolved
PROVE PROPER OPERATION OF DUMBWAITER INTERLOCK.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Electrical
Issued 10 March 2000
Resolved
PROVIDE PROPER TERMINATION IN AN ENCLOSURE FOR SPARE ELECTRICAL CABLES (2 SETS) IN ENGINE ROOM AS DISCUSSED AND IN ACCORDANCE WITH 46 CFR 120.340(G) 1999 EDITION.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Electrical
Issued 10 March 2000
Resolved
REMOVE OR COMPLETE INSTALLATION OF POWER SUPPLY TO THE 34BAR34 RECEPTACLE AENTRANCE TO ENGINE ROOM.
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Electrical
Issued 10 March 2000
Resolved
PROVIDE PLANS AND PROVE PROPER OPERATIONS OF THE GENERATOR SYCROSCOPE IN THE PARALLEL POSITION PRIOR TO USING SYSTEM. (DO NOT PARALLEL GENERATORS UNTIL APPROVED)
Condition: Unknown
Due 10 March 2000
Resolved 10 March 2000
Unknown
Issued 3 March 2000
Resolved
VESSEL IS RESTRICTED FROM CARRYING PASSENGERS UNTIL A SATISFACTORY NEW TO ZONE INSPECTION IS CONDUCTED BY THE COGNIZANT OCMI IN THE VESSEL'S NEW HOMEPORT.
Condition: Unknown
Due 3 March 2000
Resolved 3 March 2000