SAPPHIRE

SAPPHIRE is a 1999 freight ship. The Coast Guard has recorded 22 inspections since 1999, most recently in February 2012, along with 8 deficiencies and 4 operational controls.

Records from 1999 to 2012. Most recent: inspection, 19 February 2012.

Built
1999
Last inspected
19 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9189861 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
505422
Flag
GREECE
—
Maury page id
psix-505422

Inspections, by type

…with no type recorded8
Years with a record 11 calendar years (1999–2012)
The 22 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it38799 - Convention (Subpart B), Gross Ton
25382 - Convention (Subpart B), Net Ton
75574 - Dead Weight, Ton
85589 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 22

19 February 2012 PII Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4243582
18 February 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4243581
22 February 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3949976
28 December 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3911377
9 March 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3430443
17 February 2009 NPV Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3418878
16 February 2009 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3418334
16 February 2009 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3419902
28 October 2008 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3352855
17 August 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3300961
22 March 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167088
30 October 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3089710
3 May 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2639266
16 February 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2586696
3 February 2006 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2579003
25 January 2006 Type not recorded
No type recorded · USCGC SEAHAWK (WPB 87323) · USCG Southeast District (CGD-SE) · Activity 2575953
20 January 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2570848
17 January 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2567926
27 September 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2205210
6 March 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1753308
22 January 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1480489
8 November 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 434374

Deficiency record · 8

Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 28 December 2010 Resolved
Vessel was unable to provide approved instructions for weekly and monthly onboard maintenance of life saving appliances. Weekly and monthly maintenance conducted by crew is being completed with no instructions on how it shall be carried out.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 February 2011
Resolution: Received class report attesting to instructions being onboard.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 17 February 2009 Resolved
Due to an inoperable secondary radar with ARPA capabilities, the vessel does not have the ability to use the APRA for safe maneuvering and plotting. This causes unsafe conditions for navigation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: recieved tech report. Radar fully functional allowing for proper operation of the ARPA.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 February 2009 Resolved
Vessels secondary radar is inoperable and not readily available for use, this causes unsafe conditions for navigation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2009
Resolution: Recieved Tech report stating that radar is now fully functional and in proper working order.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 28 October 2008 Resolved
0735 BOTH FIREMAN OUTFITS HAS A TEAR LOCATED BETWEEN THE LEGS POSING SAFETY RISK TO THE CREW SOLAS 2001 II-2/17.3 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Resolution: VESSEL HAD TWO NEW FIRE SUITS DELIVERED ON 10/31/2008.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 28 October 2008 Resolved
0600 THREE EEBD'S WERE FOUND EMPTY AND NOT READILY AVAILABLE FOR IMMEDIATE USE. THIS POSES SAFETY RISK TO THE CREW SOLAS 2004 II-2/13.4.3 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2008
Resolution: VESSEL OFFLOADED 7 EEBD''''S AND TOOK TO AN AUTHORIZED REPAIR SHOP TO BE INSPECTED AND REFILLED. EEBDS RETURNED TO VESSEL 10/31/2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 November 2007 Resolved
The oily water seperator system failed to operate properly when tested. The OCM alarmed at 01 PPM on every test. OCM shall be calibrated to insure proper operation. Fix to the satisfaction of class.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 March 2008
Resolution: The Emitting diode was found to be malfunctioning by class. Replaced the diode OWS is working satisfactory. Received class report attesting to the proper operation.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 3 February 2006 Resolved
Vessel does not have abbreviations on port side load line. Provide Class Report attesting to permanent markings for both port and starboard load lines in accordance with ILLC Ch. 1/ Annex 1 Reg. 6
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 16 February 2006
Resolution: Received class report from ABS satisfying requirement.
Engineering › Lubricating Oil Service System › Cooler
Issued 6 March 2003 Resolved
PROVIDE ADEQUATE STIFFINERS FOR THE LUBE OIL SUPPLY LINE TO THE LUBE OIL COOLER TO MINIMIZE VIBRATION.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 April 2003
Resolved 27 September 2004
Resolution: Recieved class report from ABS satisfying requirment

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.