01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 October 2022
Resolved
Vessel was required to conduct credit drydock and Internal Structural Exam prior to 30SEP22. Vessel did not complete credit drydock and Internal Structural Exam. Vessel required to complete credit drydock and Internal Structural Exam prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2022
Resolved
Provide 2 additional life ring buoys and 1 additional ring buoy light to bring the total life ring buoys to 8 and lights to 4.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 15 June 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 April 2022
Resolved
Update vessel fire control pan with the new life ring buoys and lights
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 15 June 2022
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 March 2022
Resolved
Vessel shall ensure that storage batteries driving fitted systems for emergency lighting and power are
tested at least once each 6 months that the vessel is operated and logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 13 April 2022
Resolution: All Sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2022
Resolved
Replace Port bridge wing Life ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 14 April 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2022
Resolved
Remove all flammable liquids in wash basin space
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 14 April 2022
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2022
Resolved
Remove all combustible material in plant locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 13 April 2022
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022
Resolved
Prove proper operation of paint locker light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 13 April 2022
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 March 2022
Resolved
Replace Starboard generator flex hose from cooling tank to overflow tank.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 13 April 2022
Resolution: all sat hose has been replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 March 2022
Resolved
Remove all drain valves on the bottom of fuel filter in
E/R and provide plug.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 13 April 2022
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Emergency cleaning devices
Issued 30 March 2022
Resolved
Replace all expired eye wash stations bottles.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 13 April 2022
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2022
Resolved
Install metal guard on light over starboard generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 13 April 2022
Resolution: guard installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 March 2022
Resolved
Make both engine room to deck water tight doors water tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 15 June 2022
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 March 2022
Resolved
Provide means to conduct Low Lube oil shutdowns for
both Generators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 15 June 2022
Resolution: tested sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022
Resolved
Provide blocking and bracing for Generator battery box.
Provide call directive and handle for rudder room sound
powered Phone.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 13 April 2022
Resolution: All Sat
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 30 March 2022
Resolved
Replace missing and worn lagging on bow thrusters exhaust pipe on main deck by galley door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 15 June 2022
Resolution: replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 March 2022
Resolved
E-light on bridge is extinguished, repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 13 April 2022
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 30 March 2022
Resolved
Provide call directive and handle for rudder room sound
powered Phone.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 13 April 2022
Resolution: All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2022
Resolved
Port day tank remote emergency fuel shut off valve is stripped. Provide temp repair and a repair plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 April 2022
Resolved 14 April 2022
Resolution: Vessel has made a new closing wrench and provide a Repair plan to replace the rod during the next DD in SEP 2022.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 March 2022
Resolved
Packing flange on Stbd rudder wasted, renew at next dry dock.
Action required: 705 - Other - as specified
Due 31 March 2022
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 March 2022
Resolved
No. 3 fire station wasted, renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 15 June 2022
Resolution: alll sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 July 2021
Resolved
There is a fuel leak on the high pressure side of the fuel line on the port MDE. Repair prior to using MDE.
Action required: 705 - Other - as specified
Resolved 15 July 2021
Resolution: Tech rep repaired and CG conducted satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
While testing fuel oil shutoff valves, crew was not familiar with where tools were to access valves. Many of the deck access plugs were siezed. Prove proper operation of all fuel shutoff valves prior to departing Kachemak Bay.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
Resolution: Conducted satisfactory operation of 08 fuel shutoff valves.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 14 July 2021
Resolved
Crew was not familiar with how to close fuel shutoff valves, so did not conduct fire drill. Complete satisfactory fire drill in presence of CG Marine Inspector prior to departure from Kachemak Bay.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2021
Resolution: Conducted satisfactory fire drill.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 14 July 2021
Resolved
Vessel only had 02 charges for for line throwing device. Ensure vessel has 04 total charges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 August 2021
Resolution: Received photos of charges
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 July 2021
Resolved
Provide operating instructions for paint locker fixed fire extinguishing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 10 August 2021
Resolution: Received photo of instructions
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2021
Resolved
Mount hanging J-box in fwd AB stateroom.
Action required: 10 - Deficiency Rectified
Resolved 14 July 2021
Resolution: mounted
08 - Alarms › N/A - No Subsystem › General alarm
Issued 14 July 2021
Resolved
The visual alarm in the engine room was extinguished when general alarm was tested. Repair.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 August 2021
Resolution: Received video of operational alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
ER - the mud pump cooling line was wrapped and painted; remove and and repair if needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 August 2021
Resolution: Received photo of removed tape and vessel rep statement that operational test was sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
ER - fuel filters are not allowed to have quick acting drains; plug or renew with appropriate drains.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 August 2021
Resolution: Received photo of filter plugs installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
ER - mount oil pressure gauge on port gen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 10 August 2021
Resolution: Received photo of mounted gauge.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2021
Resolved
Remove or place in a J-box multiple deadend wires (02 in ER, 01 in bow thruster space, and 01 on deck port quarter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 August 2021
Resolution: Received photos of corrected deadend wires.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2021
Resolved
Renew all wasted hoses in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 10 August 2021
Resolution: Received photo of renewed hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 July 2021
Resolved
Renew light cover in port ER emergency escape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 August 2021
Resolution: Received photo of renewed light cover.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2021
Resolved
Inspect all kapok lifejackets for serviceability.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 23 August 2021
Resolution: Received statement from vsl rep that all kapok lifejackets have bben inspected.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 July 2021
Resolved
Ensure there is a guard on the bow thruster fly wheel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2021
Resolved 10 August 2021
Resolution: Received photo of installed guard
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 January 2019
Resolved
46 CFR 91.27-1 Complete annual COI inspection prior to conducting operations requiring COI after 26JAN19 (3 months past COI anniversary date).
Action required: 705 - Other - as specified
Resolved 5 February 2019
Resolution: Completed satisfactory annual COI inspection.
Lifesaving › Inflatable Liferafts › Servicing
Issued 10 January 2018
Resolved
Properly service liferafts, provide proof of liferaft servicing.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 7 March 2018
Resolution: Liferaft service certificate provided by operator.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 10 January 2018
Resolved
Provide proof of marine radio operator permit. 47 CFR 180.151
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 12 March 2018
Resolution: License provided.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 10 January 2018
Resolved
Provide proof of Notice of Intent Letter from EPA Clean Water Act Section 402
Due 10 February 2018
Resolved 15 January 2018
Resolution: Received copy of ENOI; placed onboard vessel.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 January 2018
Resolved
Provide and place updated tide tables on board.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 March 2018
Resolution: Vessel purchased new tide table books. All sat.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 January 2018
Resolved
Provide documentation and proof of participation in a drug and alcohol program.
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 12 March 2018
Resolution: Documentation provided.
Engineering › Steering Gear System › Follow-up Assembly
Issued 10 January 2018
Resolved
Correct follow-up steering position to provide accurate and consistent control of the system; specifically follow-up order and rudder angle indicator must match at all angles.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 9 March 2018
Resolution: Follow-up control box was remarked to align with rudder angle indicator. All sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 10 January 2018
Resolved
Prove proper operation of port main engine shutdown on bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 10 February 2018
Resolved 8 March 2018
Resolution: Witnessed proper operation of port main engine shutdown. All sat.
Construction/Loadline › Structures › Deck Plating
Issued 24 October 2017
Resolved
Provide UT gauging report of main deck on either side of the superstructure’s aft watertight door IAW Load Lines Regulation 1(2). Water intrusion is evident where exhaust stack penetrates the deck and exits the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2018
Resolved 5 March 2018
Resolution: Witnessed final NDT, all sat.
Engineering › Pressure Vessel › Safety Valve
Issued 8 September 2017
Resolved
Conduct testing or provide servicing reports of the pressure relief valves for the 04 dry bulk pressure vessels located in the #2 port and starboard ballast tanks IAW 46 CFR 126.460.
Action required: 705 - Other - as specified
Due 10 March 2018
Resolved 5 March 2018
Resolution: Witnessed final insert NDT, all sat.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 28 October 2016
Resolved
Complete testing of heat sensors and provide report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 25 January 2017
Resolution: Op tested air pressure fire detection system; all sat.
Lifesaving › Lifebuoys › Serviceable
Issued 28 October 2016
Resolved
Replace retroreflective tape on life rings as necessary
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 25 January 2017
Resolution: Retroflective tape was renewed; all sat.
Communications › Visual Communication › Signalling Lamp
Issued 28 October 2016
Resolved
Replace inoperable bulbs on pilot house alarm panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 25 January 2017
Resolution: Witnessed lamp test on bridge alarm panel; all sat
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 28 October 2016
Resolved
repair or replace rudder angle indicator in emergency steering room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 25 January 2017
Resolution: Witnessed op test of emergency steering rudder angle indicator; all sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 October 2016
Resolved
Replace battery on emergency light port escape from engine room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 25 January 2017
Resolution: E light battery was replaced and tested sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 28 October 2016
Resolved
Update and submit fire control plan to Sector Anchorage for review and approval
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 23 February 2017
Resolution: FCP has been approved.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 28 October 2016
Resolved
Repair or replace the following engine room gauges at the alarm panel in engine room:
* M/E Stbd - lube oil temp
* Stbd Gen - lube oil temp
* Port Gen - lube oil temp
* Port Gen - jacket water temp
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 25 January 2017
Resolution: Gauges were renewed; all sat.
Engineering › Fuel Oil Service System › Hose
Issued 28 October 2016
Resolved
Replace fuel/oil hoses in engine room to approved SAE J-1942
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 25 January 2017
Resolution: Hoses were renewed with SAE J1942 hose; all sat.
Engineering › Fuel Oil Service System › Hose
Issued 25 April 2016
Resolved
Various nonmetallic flexible hose installed in fuel and oil service is not fire rated.
-STBD Generator all F/O and L/O hoses
-STBD Main ENG L/O to spinner hose (also >30in)
-PORT Main ENG L/O to spinner hose (also>30in)
-Pump Eng +Bow Thruster, all F/O and L/O.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 28 October 2016
Resolution: All hoses listed were replaced except Bow thruster. Re-wrote deficiency at Oct2016 exam to replace all E/R fuel/oil hoses to approved type by next Drydock, 2017.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 25 April 2016
Resolved
No approved Periodic Safety Test Procedure on board. Provide test procedure for installed automation + alarms
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 January 2017
Resolution: PSTPs were provided onboard, however they required updating.
Electrical › Electric Supply System (service) › Cable
Issued 25 April 2016
Resolved
Properly terminate dead end wires aft of port gen.
Due 25 May 2016
Resolved 28 October 2016
Resolution: wires placed in junction box
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 April 2016
Resolved
Exhaust system lagging missing. #1(STBD) gen riser #2(Port) gen inboard elbow.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 28 October 2016
Resolution: lagging replaced satisfactorily after servicing
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2016
Resolved
Fill multi cable transit STBD of WTD in galley to center tunnel with approved watertight method.
Due 25 May 2016
Resolved 28 October 2016
Resolution: Viewed pictures of cables satisfactorily secured in bulkhead penetration.
Lifesaving › Immersion Suits › Not on Board
Issued 25 April 2016
Resolved
Obtain appropriate immersion suits for all personnel
Action required: 17 - Rectify deficiencies prior to departure
Due 25 April 2016
Resolved 25 April 2016
Resolution: Obtained appropriate sized immersion suit.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 April 2016
Resolved
Obtain appropriate number of alcohol test onboard.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 27 April 2016
Resolution: Test strips obtained
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 March 2016
Resolved
Annual inspection started on 3/16/2016, crew limited, complete inspection prior to operation.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2016
Resolved 25 April 2016
Resolution: Inspection Complete
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 16 March 2016
Resolved
Both main engine injector pumps are leaking fuel. Repair F/O leaks prior to sailing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 25 April 2016
Resolution: Caterpillar replaced injector pumps