← All vessels
AURORA AMETHYST
AURORA AMETHYST is a 1999 freight ship. The Coast Guard has recorded 23 inspections since 2000, most recently in August 2011, along with 10 deficiencies and 4 operational controls.
Records from 2000 to 2011. Most recent: operational control imposed, 29 August 2011.
- Built
- 1999
- Last inspected
- 28 August 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9188609 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DYCX
505592
Flag
PHILIPPINES
—
Maury page id
psix-505592
Inspections, by type
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it28074 - Convention (Subpart B), Gross Ton
16065 - Convention (Subpart B), Net Ton
48893 - Dead Weight, Ton
57340 - Displacement, Ton
16065 - Convention (Subpart B), Net Ton
48893 - Dead Weight, Ton
57340 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
28 August 2011
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 4130184
26 August 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4127787
8 March 2010
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3691780
13 July 2009
ISPS I Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3529037
13 July 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3535962
9 May 2009
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3455794
6 February 2008
PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3142726
11 September 2006
MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2774397
19 May 2006
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2653586
17 May 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2651587
6 May 2006
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2642528
8 August 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2455822
3 August 2005
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2449821
11 May 2005
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3641725
30 December 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2267867
25 August 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2176661
21 August 2003
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1883859
6 July 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1854988
2 July 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1833188
1 July 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1831829
19 November 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 295640
15 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 288236
20 April 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 277110
Deficiency record · 10
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 August 2011
Resolved
Vessel submitted letter of deviation for secondary marine radar. Prior to departure from the Port of Houston vessel must submit technician report attesting to the proper repair and operation of the secondary marine radar.
Fire Fighting › Firemans Outfit › Quantity
Issued 9 May 2009
Resolved
All ship's fire suites are in poor condition with significant delamination. Fire suits are not capable of acting as designed and offer inadequate fire protection.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 May 2006
Resolved
Sludge Lines from oily water separator have been removed. Changes to piping diagram must be approved by class. Or pipes must be refitted to OWS to satisfaction of class.
Documentation › Logs/Records › Bunker Delivery Notes/Samples
Issued 3 August 2005
Resolved
The Bunker Transfer procedures are not in accordance with the Code of Federal Regulations.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 3 August 2005
Resolved
The garbage containers have not been properly color-coded. All of the containers throughout the vessel need to be the same color and stenciled for the same type of garbage.
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 August 2005
Resolved
The salt water-cooling discharge pipe for the main engine has a small pinhole in it. The crew has notified and received from the company the correct pipe for replacing this section from flange to flange.
Lifesaving › Launching Appliances › Davit
Issued 3 August 2005
Resolved
The port limit switch is cracked and approximately 80% wasted due to corrosion.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 3 August 2005
Resolved
The sewage treatment plant is not being maintained as per the manufacturers requirements. Daily, weekly and monthly inspections are not being carried out. In addition the crew is not using the correct size chlorine tablets for the system.
Engineering › Steering Gear System › Rudder Stock
Issued 21 August 2003
Resolved
Vessel may not depart the berth until USCG Activities New York has received a Class Report stating that the vessel is fit for the route and services intended.
Lifesaving
Issued 20 April 2000
Resolved
STBD SIDE LIFEBOAT FALL UNEVEN. VESSEL REQUIRED TO ADJUST FALLS AND PROVIDE CLASS REPORT STATING LIFEBOAT LOWERS PROPERLY PRIOR TO DEPARTURE.