MAURY USCG vessel records Sign in
← All vessels

RAPID RUNNER

RAPID RUNNER is a 1988 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1988, most recently in March 2026, along with 43 deficiencies — 2 with no resolution recorded — and 2 casualty investigations between 2011 and 2012.

Records from 1988 to 2026. Most recent: inspection, 10 March 2026.

Built
1988
Last inspected
10 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-50573

Inspections, by type

…with no type recorded3
…past their stated due date2
Years with a record 37 calendar years (1988–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 11.0 ft × 5.0 ft
Registered tonnagegross 15 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRIVER BANK ENTERPRISES · ASOTIN, WA, UNITED STATES · built 1988
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portLEWISTON, ID
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Net Ton
15 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 50

10 March 2026 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8320395
25 March 2025 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8099690
23 May 2024 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7928962
29 March 2023 Examination of Repairs · Hull Examination · COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7666887
22 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7448535
15 April 2021 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7153548
18 February 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6917525
25 April 2019 Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6718227
19 March 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6663394
26 February 2018 Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6361907
7 March 2017 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6097783
8 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5825557
4 September 2015 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5234894
4 March 2014 Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4804931
28 September 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4156421
31 August 2011 Damage Survey · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4132286
27 August 2011 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4151819
17 March 2010 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3682432
18 March 2009 Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428828
16 April 2008 DAPI Audit
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3185796
3 April 2008 COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3171224
12 March 2008 Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3170316
27 March 2007 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3022440
14 March 2006 Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2598969
30 March 2005 Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2290839
30 March 2004 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2022333
27 March 2003 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756550
28 March 2002 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1494829
22 March 2001 Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445777
1 May 2000 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1048712
23 March 2000 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1047524
15 April 1999 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1123413
23 March 1999 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 781092
17 March 1998 Initial Construction-Excluding Oversight · Re-Inspection · Plan Review "T" Boat · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 782504
21 March 1997 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1102748
20 March 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1374538
8 May 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1042358
18 April 1995 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1163954
21 March 1995 Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1367325
10 August 1994 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1171917
15 March 1994 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1461561
15 March 1993 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1362745
24 June 1992 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1267786
20 June 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 61170
30 March 1992 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1320504
30 April 1991 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1213180
30 April 1991 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1217041
15 March 1990 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 915634
14 March 1989 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1210423
12 May 1988 Initial Certification · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1201140

Deficiency record · 43

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 March 2026 No resolution recorded
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Vessel's battery connections were observed to have conductors exposed at terminals. Vessel owner to replace connections to prevent accidental shock.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 April 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 March 2026 No resolution recorded
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. Observed visual alarm was not working when testing aft bilge pump high level alarm. Vessel owner must repair visual alarm functionality of aft bilge pump's high level alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2026 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 18 February 2020 Resolved
Make engine room bulkhead vapor tight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2020
Resolved 17 March 2020
Resolution: Conducted visual examination of bulkhead; bulkhead appears to be vapor tight.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 February 2020 Resolved
Prove proper operation of installed system IAW manufactures instructions.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2020
Resolved 17 March 2020
Resolution: Witnessed satisfactory safety function test of installed Fire Boy Fire Suppression system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2019 Resolved
Properly terminate exposed wires in engine room to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2019
Resolved 25 April 2019
Resolution: Dead end wire runs removed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 April 2018 Resolved
Prove proper operation of aft, navigation light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2018
Resolution: Vessel owner repaired aft navigation light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2018 Resolved
Replace seven adult-sized lifejackets. (No longer serviceable.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2018
Resolution: Vessel owner purchased, and replaced seven adult-sized life-jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2018 Resolved
Provide and post life-jacket donning procedures for the type of life-jacket carried aboard the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2018
Resolution: Vessel owner posted laminated life-jacket donning procedures behind the operator's chair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2018 Resolved
Replace the life-line for the ring-buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2018
Resolution: Owner purchased and installed a new life-line for the vessel's ring-buoy.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 April 2018 Resolved
Proved proper operation of the port-side fuel emergency shut-off valve from the remote location (pull cable).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2018
Resolution: Vessel owner repaired the port-side fuel shut-off valve, and proved its proper operation.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 April 2018 Resolved
Provide adequate ground tackle for use aboard the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 May 2018
Resolution: Vessel's owner purchased a grappling hook/anchor and 100' of line for his vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2018 Resolved
Install and prove the proper operation of the port, main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 October 2018
Resolved 25 June 2018
Resolution: Vessel owner installed rebuilt port, main engine in the vessel and completed a satisfactory operational test.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 March 2017 Resolved
DC01 - Provide visual high water indicator at helm to satisfaction of attending marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2017
Resolved 21 March 2019
Resolution: During annual exam verified proper operation of alarms and indicators at helm.
Lifesaving › Buoyant Apparatus › Marking
Issued 7 March 2017 Resolved
DC02 - Stencil name of vessel on ring buoy and provide proof to attending marine inspector within 60 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2017
Resolved 21 March 2019
Resolution: During annual exam verified proper labeling of lifesaving appliances.
Engineering › Steering Gear System › Actuator
Issued 4 March 2014 Resolved
Prove proper operation of the steering actuator ram. The steering gear actuator rod comes into contact with the exhaust discharge hose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2014
Engineering › Bilge Water Management System › Interface Detector
Issued 4 March 2014 Resolved
High level bilge indicator in the engine room was found to be inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2014
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 March 2014 Resolved
Properly block and brace both battery boxes.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2014
Construction/Loadline › Hull › Weld
Issued 4 March 2014 Resolved
Weld fractures were found to the upper corners of the forward cabin access frame; hinges on the forward cabin access window; both engine room vents on the outer aft corners; and the forward and aft corners on the deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 March 2014 Resolved
Float light for life buoy was missing. Vessel was restricted to daylight hour operation until item installed.
Due 4 April 2014
Resolved 10 April 2014
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 4 March 2014 Resolved
Fire extinguisher placard needs to be removed on port Engine Room vent.
Due 4 April 2014
Resolved 10 April 2014
Construction/Loadline › Hull › Bracket
Issued 4 March 2014 Resolved
Properly secure port and starboard upper side windows in the aft cabin at the deck step up.
Due 4 April 2014
Resolved 10 April 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 2 September 2011 Resolved
Have all portable fire extinguishers serviced. Send service report to the CG in Portland.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2011
Resolved 19 September 2011
Resolution: Received Service Report.
Construction/Loadline › Hull › Hull Plating
Issued 2 September 2011 Resolved
provide written repair proposal for damage to stbd transom, side and pump grate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2011
Resolved 19 September 2011
Resolution: Received photos of repair.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 March 2009 Resolved
COD expired; current COD not on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2009
Resolution: Received faxed copy of current COD.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 March 2005 Resolved
Provide proper navigation light configuration for a vessel greater than 12m (rule 23 inland) and less than 50m (rule 23 inland). COLREGS 74
Due 30 April 2005
Resolved 2 April 2005
Resolution: Navigation lights reconfigured to meet regulations.
Construction/Loadline › Hull › Hull Plating
Issued 27 March 2003 Resolved
Make repairs to fractures at the engine room vent supply ducts-both port and stbd sides. 46 CFR 176.700
Condition: Unknown
Due 27 April 2003
Resolved 22 April 2003
Construction/Loadline › Hull › Weld
Issued 27 March 2003 Resolved
Make repair to the stbd-side jet pump intake (pump suction plate) where fractured. 46 CFR 176.700
Condition: Unknown
Due 27 April 2003
Resolved 22 April 2003
Electrical › Electric Supply System (service)
Issued 27 March 2003 Resolved
Install covers over electrical wire strips/bus ties in the engine room and fuel tank compartment. 46 CFR 183.330 LEGACY COMPONENT DESC: Electrical Protection
Condition: Unknown
Due 27 April 2003
Resolved 22 April 2003
Engineering › Fuel Oil Service System › Hose
Issued 27 March 2003 Resolved
Replace all fuel hoses with approved hose (SAE J-1942 hose) or provide approved fire sleeves over current hoses. 46 CFR 182.720
Condition: Improper Installation
Due 27 April 2003
Resolved 22 April 2003
Engineering
Issued 23 March 2000 Resolved
Weld fuel fill pipe to gunwale.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Engineering
Issued 23 March 2000 Resolved
Provide supply and exhaust vents for fuel tank space.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Unknown
Issued 23 March 1999 Resolved
PROVIDE REPLACEMENT ITEMS ASPIRIN AND BURN CREAM WITH VALID EXP DATE.
Condition: Unknown
Due 23 March 1999
Resolved 23 March 1999
Lifesaving
Issued 21 March 1997 Resolved
PROVIDE FIRST AID KIT MEETING OR EQUIVALENT TO 46 CFR 160.041.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Engineering
Issued 21 March 1997 Resolved
INSTALL DRIP PANS FITTED WITH 30 X 30 MESH FLAME SCREEN UNDER EACH SET OF FUEL FILTERS.
Condition: Unknown
Due 30 April 1997
Resolved 30 April 1997
Construction/Loadline
Issued 21 March 1997 Resolved
V-WELD ALL CRACKED WELDS THROUGHOUT VESSEL. HAVE FLOOR BOARDS REMOVED AND BILGES WIPED OUT FOR FINAL INSPECTION.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Construction/Loadline
Issued 21 March 1997 Resolved
CROP AND RENEW OUTBOARD BOTTOM LONGS FROM BUTT JOINT FWD OF ENG. COMPT. TO APPROX. 16 INCHES FWD OF 3RD TRANSVERSE BOTTOM FRAME. ALSO C/R APPROX. 24 INCHES OF 2ND BOTTOM LONG FROM OUTBOARD, AS MARKED, IN WAY OF 3RD TRANSVERSE BOTTOM FRAME.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Documentation
Issued 21 March 1995 Resolved
Provide evidence of enrollment in drug testing program.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Lifesaving
Issued 21 March 1995 Resolved
Stencil vessel name on all PFD's.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Lifesaving
Issued 21 March 1995 Resolved
Provide distress flares prior to operating at night.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Construction/Loadline
Issued 21 March 1995 Resolved
Repair fracture to port engine mount inboard side.
Condition: Unknown
Due 21 March 1995
Resolved 21 March 1995
Engineering
Issued 30 March 1992 Resolved
PROVIDE INTAKE AND EXHAUST DUCTING FOR ENGINE COMPARTMENT THAT IS FIRE PROOF.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Engineering
Issued 30 March 1992 Resolved
PROVIDE BLOWER INTERLOCK SO THAT THE ENGINE DON'T START UNLESS BLOWERS ARE RUNNING.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Engineering
Issued 30 March 1992 Resolved
PROVIDE FUEL SHUTOFF VALVES AT THE FUEL TANK AND MAKE THEM OPERABLE FROM OUTSIDE THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992

Casualty record · 2

27 August 2011Routine · role: Involved in a Marine Casualty · activity 4151819
30 August 2012Routine · role: Involved in a Marine Casualty · activity 4427354
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.