Records from 1985 to 2026. Most recent: inspection, 5 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 54
5 May 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8369200
6 February 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8307074
21 May 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8140739
3 June 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7925742
27 February 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7871242
8 June 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7791755
1 June 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7712993
16 May 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7452334
15 January 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7125289
25 August 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7042161
15 May 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6688796
21 March 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6647489
2 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6404528
10 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6143047
10 May 2017
DAPI Audit
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6143076
4 May 2016
COI Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5837264
19 May 2014
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4862240
27 March 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4824434
25 June 2012
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4356353
9 March 2009
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3430712
3 June 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3226174
6 June 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2955110
30 May 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2647744
22 June 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2419750
8 June 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2114028
31 March 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2033120
10 June 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1812879
25 June 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1635670
5 June 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1467335
5 July 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1420394
21 June 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1429161
6 April 1999
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 788901
11 June 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1130095
20 June 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1386046
18 June 1997
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1111994
21 May 1997
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1099892
20 June 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441088
12 June 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 882861
17 May 1995
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 926218
5 May 1994
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1172745
13 May 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1359583
20 July 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 945111
15 July 1992
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1256434
16 June 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1467355
5 June 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1246542
16 May 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 890707
16 May 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 890870
21 December 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 931576
25 June 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 931236
2 June 1990
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 928374
29 June 1989
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 892926
5 August 1987
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1325050
31 July 1986
Re-Inspection · Credit Drydock
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1004658
9 August 1985
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 986321
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2023
Resolved
A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-round white light and sidelights. The vessel's all around white light was found to be inoperable.
33CFR83.23(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Pictured received from vessel owner showing all around white light working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2023
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: (2) Be of at least 18.3 meters (60 feet) in length.
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
Each rescue boat and ring life buoy must be marked with Type II retro reflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Inspector found vessel's ring life buoy lifeline to be less than 60 feet, unmarked and missing retro reflective tape in one side.
46CFR180.70(c)(2)
46CFR604(b)&(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Pictured received from vessel owner showing ring life buoy's lifeline had been replaced, lifeline has been marked and retro tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 June 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel did not have flares on board.
46CFR180.68(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Received picture from vessel owner showing flares had been purchased.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 June 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The vessel did not have emergency instructions at the operating station.
46CFR185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Received picture showing emergency instructions had been posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 June 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel did not have life jacket donning placard on board.
46CFR185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Received picture showing life jacket donning placard had been posted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 June 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel does not have first aid kit on board.
46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Received picture showing first aid kit had been purchased.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 June 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel portable lights did not have working batteries.
46CFR183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 8 June 2023
Resolution: Received picture showing portable lights batteries had been replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 May 2017
Resolved
Fixed extinguishing system was overdue for annual inspection.
Action required: 705 - Other - as specified
Due 19 May 2017
Resolved 19 May 2017
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 June 2002
Resolved
Label each inboard side of launch with "Passengers Must Remain Seated," in lieu of standard railing.
Due 25 July 2002
Resolved 10 July 2002
Lifesaving
Issued 5 June 2001
Resolved
REPLACE REFLECTIVE TAPE ON 2 LIFEJACKETS. VSL TO CARRY TOTAL
Condition: Unknown
Due 10 June 2001
Resolved 4 October 2001
Fire Fighting
Issued 5 June 2001
Resolved
RESTORE FIXED FIRE FIGHTING SYSTEM TO PROPER OPERATION AND CARRY EXTRA 15LBFIRE EXTINGUISHER ON BOARD UNTIL ABOVE IS COMPLETED.
Condition: Unknown
Due 10 June 2001
Resolved 4 October 2001
Fire Fighting
Issued 21 June 1999
Resolved
Provide ventilation closures for engine box vents.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Lifesaving
Issued 16 June 1992
Resolved
Provide 04 Red Flares
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Electrical
Issued 16 June 1992
Resolved
Shore battery to minimize movement
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Engineering
Issued 16 June 1992
Resolved
Provide double hose clamps on raw water intake.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Construction/Loadline
Issued 16 June 1992
Resolved
Provide adequate hanger for bilge hose.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Engineering
Issued 16 May 1991
Resolved
STENCIL EMERGENCY FUEL SHUT-OFF LOCATION ON ENGINE
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
STENCIL LIFE PRESERVER LOCKER WITHY NUMBER CONTAINE WITHIN
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Construction/Loadline
Issued 2 June 1990
Resolved
REATTACH CAPTIVE CHAINS TO DECK HATCHES ACTUAL COMPLIANCE DATE: 16JUN90
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Lifesaving
Issued 2 June 1990
Resolved
LABEL PFD STORAGE WITH LETTERING 1-1/2" HIGH ACTUAL COMPLIANCE DATE: 16JUN90
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Documentation
Issued 2 June 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Navigation
Issued 2 June 1990
Resolved
MOUNT COMPASS ON VESSEL ACTUAL COMPLIANCE DATE: 16JUN90
Condition: Unknown
Due 2 June 1990
Resolved 2 June 1990
Electrical
Issued 29 June 1989
Resolved
PROVIDE MECHANICAL CRIMP OR SOLDER ELECTRICAL FORWARD
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989
Resolved
RENEW CHINE OR REPLACE RING BOUY
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989
Resolved
PROVIDE 18 LANYARD FOR WATER LIGHT WITH QUICK CONNECTION
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Engineering
Issued 29 June 1989
Resolved
PROVIDE REINFORCED OIL RESISTANT BILGE HOSE TO ELECTRIC PUMP
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Engineering
Issued 29 June 1989
Resolved
PROVIDE ALARM LIGHT FOR BILGE ELECTRIC PUMP AT NAV CONSOLE
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Engineering
Issued 29 June 1989
Resolved
MAKE VESSEL AVAILABLE FOR OPERATIONAL TEST
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Navigation
Issued 29 June 1989
Resolved
DOUBLE CLAMP ALL 3 THROUGH HULL FITTINGS
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989