Records from 2016 to 2024. Most recent: inspection, 22 July 2024.
Inspection history · 10
22 July 2024
COI Inspection · Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7963976
15 May 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7931600
22 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7435897
10 June 2021
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7222434
15 July 2020
Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7007051
14 April 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6939843
23 April 2019
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6669300
15 May 2017
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6144008
19 April 2017
Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6129665
25 July 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5851867
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 July 2024
Resolved
Handle on fuel shut off valve missing.
Due 24 July 2024
Resolved 25 July 2024
Resolution: Handle replaced. Valve tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 July 2024
Resolved
Electric submersible bilge pump does not have a working visual indicator to tell when pump is running.
Due 7 August 2024
Resolved 7 August 2024
Resolution: Indicator installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2024
Resolved
Life jackets and ring buoy need to have full vessel name on them.
Due 7 August 2024
Resolved 7 August 2024
Resolution: Equipment labelled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2024
Resolved
Flexible lines in machinery space need to have double clamps where possible.
Due 7 August 2024
Resolved 7 August 2024
Resolution: Lines clamped where possible.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 July 2020
Resolved
Engine would not over ride and restart when fireboy engine shut off was demonstrated. Repair as needed.
Due 15 July 2020
Resolved 22 July 2020
Resolution: System repaired and tested to satisfaction of MI.
Engineering › Bilge Water Management System › Pump
Issued 15 May 2017
Resolved
Vessel has two bilge pumps which work, but the audible/visual alarm does not.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 22 May 2017
Resolution: Circuit is powered by an 9V battery. The battery was renewed.