Inspection history · 54
5 June 2026
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8392763
29 May 2026
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8383564
2 October 2025
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8228024
12 September 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8001517
11 June 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7980598
19 October 2023
Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7811061
17 July 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7744790
18 January 2023
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7623089
19 July 2022
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7511882
15 June 2021
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7227068
21 May 2021
Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7202971
21 May 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6691432
13 September 2017
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6277145
13 September 2016
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5996284
26 June 2015
COI Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5163875
13 August 2014
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4952350
21 May 2014
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4864514
22 August 2013
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4691390
15 October 2012
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4464431
5 October 2011
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4161736
14 July 2010
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3794760
18 August 2009
Internal Structural Exam · Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3569849
30 September 2008
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3316832
15 August 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3028582
25 August 2006
Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 2759371
13 June 2005
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2389631
30 August 2004
Annual Inspection · Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2181543
26 May 2004
Administrative Inspection
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2079185
10 February 2004
Administrative Inspection
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2003800
29 January 2004
Administrative Inspection · Security Plan Review - ASP
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2018642
24 September 2002
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1728475
21 June 2001
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1068474
21 June 2000
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1050941
25 May 1999
Hull Examination · Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1442844
22 June 1998
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 793239
29 May 1997
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1107337
4 June 1996
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1084612
30 October 1995
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1189045
16 October 1995
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1191351
6 July 1995
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1192600
5 June 1995
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 872613
2 December 1994
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1180458
31 May 1994
Hull Examination · Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1170579
4 June 1993
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 837694
2 June 1993
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1149932
8 June 1992
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 951632
4 June 1991
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 908164
11 June 1990
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 914103
14 June 1989
Hull Examination · COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 894615
9 June 1988
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1198085
22 February 1988
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1022896
15 June 1987
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1002222
11 June 1986
Credit Drydock · Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1298752
20 June 1985
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 985864
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2026
Resolved
Provide updated annual service report for cargo systems showing completed repairs and DOT compliance. Due 07Aug26.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2026
Resolved 8 July 2026
Resolution: Updated inspection report provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 December 2025
Resolved
Vessels subject to this subpart may not perform the following functions, unless operating in compliance with a plan approved under § 155.1065:(1) Handling, storing, or transporting oil on the navigable waters of the United States; or(2) Transferring oil in any other port or place subject to U.S. jurisdiction. Vessel does not have an approved vessel response plan under 155.1065.
33 CFR 155.1025
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2026
Resolution: Valid VRP on file for MSU Duluth zone.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 2 October 2025
Resolved
Each nonmetallic transfer hose must: Not burst, bulge, leak, or abnormally distort under static liquid pressure at least 1 1/2 times the maximum allowable working pressure. Vessel is only testing their hoses to 1.2 times the MAWP.
33 CFR 155.800
33 CFR 154.500(f)(3)
33 CFR 156.170(c)(1)(iii)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2025
Resolution: Vessel completed new hose test to 1.5x MAWP.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 12 September 2024
Resolved
Cargo hoses not marked ina ccordance with 33 CFR 154.500.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 October 2024
Resolved 26 September 2024
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2023
Resolved
Cargo tranfer hose is in need of replacement. 46CFR32.50-30
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 19 October 2023
Resolution: Hose replaced.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 17 July 2023
Resolved
Warning sign deteriorated and is in need of replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2023
Resolved 19 October 2023
Resolution: New sign.
Engineering › Bilge Water Management System › Pump
Issued 13 September 2017
Resolved
Use of the onboard electronic bilge pumps is not authorized while the barge is operating due to the potential for ignition with gasoline fumes and issues with wiring. Alternate methods will be explored for rectification.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 21 May 2019
Resolution: Owner provide explosion proof wire connections.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 13 September 2016
Resolved
No copy of vessel response plan aboard. Copy of approved response plan must be on board. Required prior to next transfer operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2016
Resolved 13 September 2017
Resolution: Verified by CG inspectors during the 2017 annual inspection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 September 2016
Resolved
No record of cargo piping or hose tests. Cargo piping and hoses must be tested annually. Required prior to next transfer operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2016
Resolved 13 September 2017
Resolution: Verified by CG inspectors during the 2017 annual inspection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 September 2016
Resolved
No test of cargo pump pressure relief valve. Test of pressure relief valve required annually. Required prior to next transfer operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2016
Resolved 13 September 2017
Resolution: Verified by CG inspectors during the 2017 annual inspection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 5 October 2011
Resolved
Provide/install remote shut down for cargo pump.
Action required: 705 - Other - as specified
Due 1 May 2012
Resolved 1 May 2012
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 13 July 2010
Resolved
Replace two discharge hoses at transfer pump, both are worn and wasted. Ensure new hose are hydrostatically tested prior to installing and are compatible with fluids being stored and transferred.
Condition: Improper/Lack of Maintenance
Due 14 August 2010
Resolved 27 July 2010
Resolution: Received pics and letter from O/O. all sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 13 July 2010
Resolved
Replace exhaust piping on both transfer pumps. Piping is worn and wasted.
Condition: Improper/Lack of Maintenance
Due 14 August 2010
Resolved 27 July 2010
Resolution: Corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 30 September 2008
Resolved
Complete hydrostatic test on cargo hoses and provide documentation to OCMI prior to next cargo transfer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2009
Resolution: Received confirmation of tests.
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 September 2008
Resolved
Properly replace damaged electrical wiring for aft bilge pump prior to operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2009
Resolution: completed
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 15 August 2007
Resolved
Transfer hose not hydro tested. Operator required to test hase and provide documentation to uscg prior to cargo ops. 33CFR156.170
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2007
Resolution: Cargo hose teseted as required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 August 2007
Resolved
Bilge pump wiring not secured to vessel and is run across cargo tanks (group of home heating oil tanks). Porperly run, protect, and secure wiring IAW 46CFR111.60.
Due 14 September 2007
Resolved 28 August 2007
Resolution: Wiring removed vice re-routed.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 14 June 2005
Resolved
Pressure test cargo piping and hose and stencil with Maximum allowable working pressure (MAWP).
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 September 2005
Resolution: Received faxed copy of invoice for completion of hose testing.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 June 2005
Resolved
Provide proof of enrollment in Chemical Testing Program.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 July 2005
Resolved 15 June 2005
Resolution: Received fax copy of enrollment form.
Accommodation/Occupational Safety › Occupational Safety
Issued 24 September 2002
Resolved
Found vessel's "No Smoking " signs to be in poor condition. 835 issued. repair or replace. LEGACY COMPONENT DESC: Smoking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 30 April 2004
Construction/Loadline › Markings
Issued 24 September 2002
Resolved
Issued 835 to owner to have vessel's lic. numbers redone and made visable. LEGACY COMPONENT DESC: Vessel Name/Home Port
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 30 April 2004
Documentation
Issued 25 May 1999
Resolved
PRIOR TO ANY CARGO TRNSFER OPERATIONS, RENEW TANKERMAN CERTIFICATE.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Documentation
Issued 16 October 1995
Resolved
PROVIDE AN APPROVED VESSEL RESPONSE PLAN PRIOR TO THE 1996 OPERATING SEASON. MSO DULUTH PERSONNEL ARE AVAILABLE FOR ASSISTANCE AND DIRECTION. SUBMIT YOUR PROPOSED PLAN TO MSO DULUTH. MSO DULUTH WILL ENDORSE AND FORWARD YOUR PLAN TO COMMANDANT (G-MRO-2).
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Fire Fighting
Issued 5 June 1995
Resolved
SERVICE BOTH B-II DRY CHEMICAL FIRE EXTINGUISHERS IN ACCORDANCE WITH NFPA- 10 SERVICING REQUIREMENTS. _x001C_ THIS ITEM MAY BE CLEARED BY LETTER OR FAX TO OCMI DULUTH. INCLUDE COPY OF SERVICING RECEIPT.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Documentation
Issued 5 June 1995
Resolved
SUBMIT VESSEL RESPONSE PLAN TO COMMANDANT (G-MEP-6) FOR APPROVAL. HAVE APPROVED VESSEL RESPONSE PLAN ON BOARD VESSEL NO LATER THAN 05 AUGUST 1995.THIS REQUIREMENT MAY BE CLEARED BY LETTER OR FAX ADDRESSED TO OCMI DULUTH; LETTER SHOULD INCLUDE STATEMENT OF COMPLETION SIGNED BY VESSEL OPERATOR.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Electrical
Issued 15 June 1987
Resolved
REPAIR WIRING ON TUG ALTERNATOR.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Construction/Loadline
Issued 15 June 1987
Resolved
REPAIR 3 FRACTURES SHEER STRAKE STBD BOW AND 1 FRACTURE SHEER STRAKE PORT BOW.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Construction/Loadline
Issued 15 June 1987
Resolved
REPAIR OR REPLACE FRONT DECK.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Deck/Cargo
Issued 15 June 1987
Resolved
REPAIR OR REPLACE PV CAPS ON TANKS 3,5 & 6.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987