Records from 1985 to 1995. Most recent: inspection, 23 May 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
23 May 1995
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 871043
6 April 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 856757
22 April 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1156072
15 April 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 959623
4 June 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1318324
18 April 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 921855
23 May 1990
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1217514
23 April 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1233843
29 March 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1206470
10 May 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1351268
20 May 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1024472
16 April 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1316928
23 May 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1304908
30 April 1986
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987384
18 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1285751
Lifesaving
Issued 18 April 1991
Resolved
RESTENCIL VESSEL NAME ON RING LIFE BOUY AND LIFE PRESERVERS AS NEEDED.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Lifesaving
Issued 18 April 1991
Resolved
PROVIDE ON BOARD 1 ADULT SIZE LIFE PRESERVER, MAXIMIUM NUMBER OF ADULT PERSONS ON BOARD REDUCED TO 12.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Lifesaving
Issued 18 April 1991
Resolved
PROVIDE ON BOARD 6 ORANGE AND 6 RED FLARES.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Lifesaving
Issued 18 April 1991
Resolved
PROVIDE WATER PROOF CONTAINER FOR FLARES.
Condition: Unknown
Due 18 April 1991
Resolved 18 April 1991
Lifesaving
Issued 23 April 1990
Resolved
PROVIDE MOUNTING BRACKET FOR RING BOUY.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 23 April 1990
Resolved
PROVIDE EMERGENCY DISCONNECT SWITCH CLOSE TO BATTERIES.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Construction/Loadline
Issued 23 April 1990
Resolved
REPAIR HORN.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Documentation
Issued 23 April 1990
Resolved
PROVIDE EMERGENCY CHECKOFF LIST.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Construction/Loadline
Issued 23 April 1990
Resolved
CONDUCT CREDIT DRYDOCK EXAM PRIOR TO OPERATION.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 23 April 1990
Resolved
SECURE BATTERY BOXES.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Construction/Loadline
Issued 23 April 1990
Resolved
DETERMINE SOURCE OF WATER IN STARBOARD HULL, MAKE PERMANENT REPAIR AND PROVE TIGHT PRIOR TO OPERATION.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Electrical
Issued 23 April 1990
Resolved
REPLACE ALL WIRE NUTS IN ELECTRICAL SYSTEM WITH APPROVED CRIMP TYPE CONNECTIONS.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Construction/Loadline
Issued 23 April 1990
Resolved
REPLACE TO GOOD WOOD ROTTED AFT AREA OF DECK.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Engineering
Issued 23 April 1990
Resolved
REPLACE FUEL HOSE.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Construction/Loadline
Issued 23 April 1990
Resolved
PROVIDE 30" RAILS.
Condition: Unknown
Due 23 April 1990
Resolved 23 April 1990
Lifesaving
Issued 16 April 1987
Resolved
REPLACE WATER LIGHT BATTERY PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Lifesaving
Issued 16 April 1987
Resolved
REMARK RING BUOY WITH VESSEL'S NAME.
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Electrical
Issued 30 April 1986
Resolved
PROVIDE BATTERY BOX THAT IS RESISTANT TO ACID AND IN COMPLIANCE WITH 46CFR 183.05-20(D).
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986
Electrical
Issued 30 April 1986
Resolved
INSTALL TERMINAL BLOCK FOR VESSELS ELEACTICAL DISTRIBUTION.
Condition: Unknown
Due 30 April 1986
Resolved 30 April 1986