Records from 1999 to 2001. Most recent: inspection, 22 January 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
22 January 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286260
28 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 283261
28 October 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 823509
30 March 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 276312
16 October 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433803
16 October 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1126528
Documentation
Issued 28 October 2000
Resolved
CONDUCT AND DOCUMENT TRAINING OF ALL CREW AND OFFICERS IN APPLICABLE CRITICAL OPERATIONS PER VESSEL'S SAFETY MANAGEMENT SYSTEM TRAINING PLAN (DOC: CMCAP 001, REV.0): REQUIRED TO BE COMPLETED PRIOR TO DOWNGRADING OF 2MAJOR NONCONFORMITIES TO NONCONFORMITIES.
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Lifesaving
Issued 28 October 2000
Resolved
MAINTENANCE/SAFETY ITEMS ON DECK: DANGLING LIGHT FIXTURE ON FANTAIL, DANGLING MANUAL OIL SEAL PUMP ON #3 CARGO PUMP, BRACKETS FOR 4 INCH DIA HYDRAULIC PIPING AT PORT SIDE EXTERIOR COMPRESSOR ROOM (SOLAS 74 [AMD] I/11): MAKE REPAIRS TO INDICATED ITEMS.
Condition: Unknown
Due 22 November 2000
Resolved 14 February 2001
Fire Fighting
Issued 28 October 2000
Resolved
NUMEROUS HOLED FIRE HOSES (SOLAS 60, II/66): REPLACE FIRE HOSES AS NECESSARY.
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Deck/Cargo
Issued 28 October 2000
Resolved
LEAKING HYDRAULIC PIPING TO ANCHOR WINDLASS COVERED WITH CEMENT PATCH (SOLAS 74 [AMD] I/11): MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 22 November 2000
Resolved 14 February 2001
Deck/Cargo
Issued 28 October 2000
Resolved
GLYCOL TANK IN COMPRESSOR ROOM LEAKING (SOLAS 74 [AMD] I/11): REPAIR OR REPLACE GLYCOL TANK.
Condition: Unknown
Due 22 November 2000
Resolved 14 February 2001
Lifesaving
Issued 28 October 2000
Resolved
AIR LOCK SELF-CLOSING DOOR INOPERABLE (EXISTING GAS CARRIER CODE 11.3.1): PROPERLY ADJUST DOOR.
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Documentation
Issued 28 October 2000
Resolved
PROVIDE SURVEY REPORT FROM CERTIFICATE ISSUING AUTHORITY (I.E. CLASS) INDICATING STATUS & CONDITION OF ALL CRITICAL EQUIP SPECIFIED IN VSL'S SMS PLAN (SECTION G, DOC: CMMAP 001, REV.1): REQ'D TO BE COMPLETED PRIOR TO DOWNGRADING OF 2 MAJOR NONCONFORMITIES TO NONCONFORMITIES.
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Fire Fighting
Issued 28 October 2000
Resolved
NUMEROUS CLOGGED NOZZLES AND PIPING LEAKS RESULTING IN INSUFFICIENT COVERAGE BY CARGO DECK WATER SPRAY SYTEM.
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Documentation
Issued 28 October 2000
Resolved
VALIDITY OF VESSEL'S SAFETY MANAGEMENT SYSTEM IN QUESTION.
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Deck/Cargo
Issued 28 October 2000
Resolved
PRESSURE AND TEMPERATURE GAUGES FOR CARGO TANKS NOT CALIBRATED SINCE OCT96 (EXISTING GAS CARRIER CODE 13.1.2): PROVIDE ADMINISTRATION REQUIREMENT FOR CALIBRATION AND/OR RECALIBRATE GAUGES.
Condition: Unknown
Due 3 November 2000
Resolved 3 November 2000
Electrical
Issued 16 October 1999
Resolved
Hole in emergency generator electrical panel needs to be covered.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Accommodation/Occupational Safety
Issued 16 October 1999
Resolved
Install cover for rotating machinery in the provision freezer.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Construction/Loadline
Issued 16 October 1999
Resolved
Provide Marpol standard discharge connection.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Construction/Loadline
Issued 16 October 1999
Resolved
Eliminate the unused discharge line from the 100PPM oil water seperator.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Construction/Loadline
Issued 16 October 1999
Resolved
Repack or replace General System #1 and #2 Pump Valves. To satisfaction ofclass.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Fire Fighting
Issued 16 October 1999
Resolved
Cover heat sensor in purifying room.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Lifesaving
Issued 16 October 1999
Resolved
Install light covers throughout the engine room.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000