← All vessels
PATROL II
Passenger (Inspected) · Passenger Ship class · Built 1940s · USCG Northeast District (CGD-NE) · Other hulls named PATROL II
PATROL II is a 1947 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1984, most recently in June 2026, along with 84 deficiencies and 1 operational control.
Records from 1984 to 2026. Most recent: inspection, 11 June 2026.
- Built
- 1947
- Last inspected
- 11 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 84 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
WDN8267
50616
Flag
UNITED STATES
—
Maury page id
psix-50616
Inspections, by type
…with no type recorded3
Years with a record
36 calendar years (1984–2026)
The 57 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 57
11 June 2026
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8402851
14 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8208930
3 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8042001
27 June 2024
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7924037
8 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7681585
9 November 2022
Internal Structural Exam · Hull Examination · Construction Oversight
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7591922
12 May 2022
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7445204
21 January 2021
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7130409
5 October 2020
Administrative Inspection · Internal Structural Exam · Plan Review "T" Boat · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7084238
9 September 2020
Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7055293
16 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6810956
25 June 2019
Hull Examination · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6725087
9 July 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6469120
13 June 2018
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6437951
30 May 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6236138
16 June 2016
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5941744
23 May 2016
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5884501
11 June 2014
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4886621
5 June 2014
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4880559
26 June 2012
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4356247
1 June 2012
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4331289
23 July 2008
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3271478
5 June 2008
Hull Examination
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3185581
10 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2959457
29 June 2006
Hull Examination · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2687908
27 June 2005
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2404492
7 June 2004
Hull Examination · Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2086646
28 July 2003
Deficiency Check
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1863907
14 July 2003
Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1834131
18 June 2002
Re-Inspection · Hull Examination
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1632017
24 September 2001
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1075424
3 July 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1457957
6 July 2000
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1052001
28 June 2000
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1052000
10 August 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1427748
8 July 1998
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1129818
22 June 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1129813
24 September 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1111560
30 December 1996
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1093925
6 November 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1169897
15 July 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1089586
14 June 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 872314
7 May 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 837914
27 June 1994
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1363015
9 June 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1392019
10 August 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1473223
6 July 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1252756
17 June 1992
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1251820
11 July 1990
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 932146
8 May 1990
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 909588
28 July 1989
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1042841
12 July 1989
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1044763
8 July 1988
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1338051
31 March 1988
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1301996
16 June 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 995896
8 July 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 983269
8 November 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1283585
Deficiency record · 84
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 11 June 2026
Resolved
A mariner may not serve under the authority of an MMC past its expiration date. An expired MMC may be renewed during an administrative grace period of up to 1 year beyond its expiration date as per §?10.227(h) of this part. Vessel is unable to produce proper credentials for the Master. Provide credentials IAW with the cited regulation prior to operating within the conditions of the COI.
46CFR 10.205
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 June 2024
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Upon arriving to the vessel no one was able to produce credentials. The master departed inspection to retrieve theirs. Upon presenting, no medical card could be located. Vessel to provide proof of a medically qualified Master to the attending USCG MI within 14 days.
46CFR 10.301
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 June 2024
Resolved
Valves for drawing fuel or draining water from fuel are not permitted in fuel oil systems except that a single valve may be permitted in the case of diesel driven machinery if suitably located within the machinery space away from any potential source of ignition. Such a valve shall be fitted with a cap or a plug to prevent leakage.
F/O water separator/filter is missing the required plug. Provide IAW regulation.
46CFR 56.50-60.f.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 June 2024
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Vessel to re-stencil ring buoy
and Type I PFD's to come in to compliance.
46CFR 185.604.b.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 June 2024
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Ring buoy is missing retro tape. Provide IAW regulation.
46CFR 185.604.i.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2024
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Vessel to provide clip to the waterlight of 3-6 foot (46CFR 180.70.d.2.) lanyard for ring buoy.
46CFR 180.70.d.3.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 June 2024
Resolved
A vessel not required to have a power driven fire pump by §?181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets. Vessel is missing 01 fire bucket. Provide IAW regulation.
46CFR 181.610
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2024
Resolved
When, in accordance with §178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Vessel unable to provide any form of stability letter, memo or booklet. Provide IAW regulation.
46CFR 176.306
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 June 2024
Resolved
Vessel had expired medications on board. Removed prior
to completion of exam. Corrected on the spot.
46CFR 184.710
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
04 jife jackets found not serviceable, until rectified, max allowable persons carried is reduced to 10
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2022
Resolved
A vessel of more than 36 feet in length, must carry a minimum of one life buoy of not less that 24 inches in diameter
Life buoy found in un-serviceable condition.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 September 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The Fireboy has been disconnected due to the failure of an interlock between the engine and the fireboy, leaving the space unprotected, as well as dead-ended wires behind the fire panel and in the engine compartment.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2020
Resolved
The Cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel is taking on water through a 1/8 inch hole under the waterline on the STBD aft area of the vessel. Additionally, other dry-rot was discovered throughout the vessel. Vessel must undergo a Credit Drydock and Internal Structural Examination.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 September 2020
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel's bilge pump was inoperable, and was not of the appropriate approval.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2020
Resolved
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel had installed a wooden plug in the hull on the STBD midships area to prevent water ingress. The plug was roughly 1 and 1/4 inch in diameter.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2020
Resolved
A drydock examination conducted in compliance with 46 CFR 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. For wooden vessels, fastenings may be required to be pulled for examination. During the inspection, the marine inspector pulled a fastener out through the bilge-side of the vessel. Vessel must undergo additional fastener pulls during next credit Drydock Exam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2020
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Numerous exposed or dead-ended wires were discovered throughout the vessel, including behind the fire control panel, on the Fireboy, in the forward compartment and in the vicinity of the Main Engine.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2020
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. The engine coolant hose on the MDE is dry-rotted and no longer serviceable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2020
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. The engine cooler gasket is wasted and no longer serviceable, causing a leak of cooling water into the bilge of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 September 2020
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. The Port side aft engine mount is cracked entirely through.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2020
Resolved
Non-metallic hose may be used for exhaust provided it is specially adapted to resist the action of oil, acid and heat. Vessel exhaust hose was partially melted and no longer serviceable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2020
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] wires were zip-tied to the engine, presenting an electrical fire hazard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2020
Resolved
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel has altered their reduction gear piping. These alterations were not reviewed or approved.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 September 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 46CFR 160.041 or a kit with equivalent contents and instructions. The vessel's onboard first aid kit did not meet the specified requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 September 2020
Resolved
All agreements and arrangements, written or unwritten, between and among employers and service agents concerning the implementation of DOT drug and alcohol testing requirements are deemed, as a matter of law, to require compliance with all applicable provisions of this part and DOT agency drug and alcohol testing regulations. Compliance with these provisions is a material term of all such agreements and arrangements. Vessel could not provide proof of enrollment in a DAPI program.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 September 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. The interlock that shuts down the engine upon discharge of the pre-engineered fire system has failed, and is not allowing the engine to start.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2020
Resolved
The Cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel is taking on water, as evidenced by the activation of the bilge pump no less than 3 times during inspector attendance. Vessel must undergo a Credit Drydock and Internal Structural Examination.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2020
Resolved
Each small battery installation must be protected from falling objects. There was no lid on the battery box, and the battery terminals were exposed to potential falling objects.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2020
Resolved
Each life jacket must be approved in accordance with either 160.002, 160.005, or 160.055 in subchapter Q of this chapter, or other standard specified by the Coast Guard. 04 of the vessel's adult life jackets were unapproved and were marked as "Not for commercial use."
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 September 2020
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 03 of the vessel's approved adult lifejackets were found to be in unserviceable condition.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 September 2020
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The grab-line on the vessel's life ring buoy was dry-rotted and unserviceable.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2020
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life jacket. 01 child life jacket possessed the name of another vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 July 2019
Resolved
Vessel must be provided with 03 orange smoke distress signals.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 June 2019
Resolved
Raw water cooling pump is leaking water into the vessel. Replace with new one.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 30 May 2017
Resolved
Clean bilge.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 30 May 2017
Resolved
Provide MMD for actual Captian of the vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 May 2017
Resolved
Conduct drills MOB and Fire.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 16 June 2016
Resolved
F/O hoses are wasted
Navigation › Piloting/Steering › Marine Charts
Issued 24 May 2016
Resolved
Provide new Harbor Charts
Engineering › Bilge Water Management System › Pump
Issued 24 May 2016
Resolved
Prove proper operation of bilge high water light.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 24 May 2016
Resolved
Prove proper operation of bilge pump/float switch.
Lifesaving › Hand Flares › Approval
Issued 24 May 2016
Resolved
Replace pistol flares w/ approved flares Red hand flares.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 May 2016
Resolved
Provide corrosion res. clip for life ring water light.
Construction/Loadline › Hull › Transverse Frame
Issued 5 June 2014
Resolved
Crop and renew and/or sister rotten frames #5, 6, and 9 portside located in main passenger space.
Construction/Loadline › Hull › Keel Plate
Issued 5 June 2014
Resolved
Crop and renew forward 2 foot section of the horn timber (rotten) located above the shaft log.
Construction/Loadline › Hull › Keel Plate
Issued 5 June 2014
Resolved
Crop and renew skeg (rotten) and its lag bolts.
Construction/Loadline › Structures › End Bulkhead
Issued 29 June 2006
Resolved
Repair all holes in engine room bulkhead prior to placing boat in commercial service. Demonstrate satisfactory repairs to USCG inspector.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 29 June 2006
Resolved
Replace retro tape on 19 adult life jackets prior to placing vessel i commercial service. Demonstrate satisfactory repairs to USCG inspector.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 29 June 2006
Resolved
Fire-Boy engine shut down is not wired into system. Repair and prove proper operation of this sytem to a USCG inspector prior to placing vessel in commercial service.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 June 2006
Resolved
Mount COI, Passsenger Emergency Instructions, and Life Jacket Donning Instructions in visible location to passengers prior to placing vessel in commercial operations. Demonstrate satisfactory repairs to USCG inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 27 June 2005
Resolved
PROVIDE 1 B-II FIRE EXTINGUISHER AND SERVICE THE B-1 FIRE EXTINGUISHER AND FIXED ENGINEROOM FIRE SYSTEM.
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 June 2005
Resolved
LABEL THE FUEL OIL SHUT OFF VALVE.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 June 2005
Resolved
PROVIDE ON BOARD COPY OF THE COI.
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 27 June 2005
Resolved
REPLACE EMERGENCY CHECK OFF LIST AND THE LIFE JACKET DONNING PROCEDURES PLACARD.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 June 2004
Resolved
REPAIR BILGE ALARM AND FIRE BOY WIRING.
Fire Fighting › Fire Bucket › Capacity
Issued 7 June 2004
Resolved
PROVIDE 3 - 2 1/2 GALLON FIRE BUCKETS WITH LINE.
Electrical › Electric Supply System (service) › Battery Installation
Issued 7 June 2004
Resolved
REINSTALL BATTERY COVERS.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 7 June 2004
Resolved
PROVIDE 3 ORANGE SMOKE FLARES.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2004
Resolved
PROVIDE FIRST AID KIT.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 June 2004
Resolved
SEAL UP FORWARD ENGINEROOM BULKHEAD.
Communications › Alarms/Indicators
Issued 14 July 2003
Resolved
REPAIR BILGE ALARM TO OPERATIONAL CONDITION. LEGACY COMPONENT DESC: Bilge Alarm
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 14 July 2003
Resolved
REINSTALL MANUAL SHUT DOWN WIRE FOR THE FIXED FIREFIGHTING SYSTEM IN THE ENGINEROOM. LEGACY COMPONENT DESC: Operating Controls
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 14 July 2003
Resolved
INSTALL A B-II PORTABLE FIRE EXTINGUISHER. LEGACY COMPONENT DESC: Number
Lifesaving › Lifebuoys
Issued 14 July 2003
Resolved
INSTALL LINE WITH A CLIP FOR ATTACHING THE FLOAT LIGHT TO THE RING BUOY. LEGACY COMPONENT DESC: Self-igniting Lights
Electrical › Electric Supply System (service)
Issued 14 July 2003
Resolved
PLACE TWO BATTERIES INTO BOXES AND PROVIDE COVERS FOR ALL BATTERIES. LEGACY COMPONENT DESC: Battery Installation
Fire Fighting › Miscellaneous Items
Issued 18 June 2002
Resolved
INSTALL THE REMOTE ACTIVATION CONTROL FOR THE FIXED DRY CHEM FIRE EXTINGUISHER IN ENGINEROOM.
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 June 2002
Resolved
PROVIDE TWO ADULT AND ONE CHILD TYPE I LIFE JACKETS TO MEET ALLOWED PASSENGER NUMBERS. LEGACY COMPONENT DESC: Quantity
Engineering › Bilge Water Management System
Issued 18 June 2002
Resolved
CAP THE OVERBOARD PIPE FROM THE OLD BILGE OVERBOARD LINE ON THE STARBOARD SIDE OF THE VESSEL. LEGACY COMPONENT DESC: Piping
Fire Fighting
Issued 3 July 2001
Resolved
PROVIDE MANUAL CONTROLS FOR FIXED FIRE FIGHTING SYSTEM AT THE OPERATING STATION AS REQUIRED BY 46 CFR 181.410(c)(2).
Construction/Loadline
Issued 3 July 2001
Resolved
PROVE PROPER OPERATION OF BILGE HIGH LEVEL ALARMS AS REQUIRED BY 46 CFR 182.530.
Lifesaving
Issued 10 August 1999
Resolved
Life ring; install 60ft of line/ 3ft lanyard on waterlight.
Construction/Loadline
Issued 10 August 1999
Resolved
Install bilge alarm.
Engineering
Issued 10 August 1999
Resolved
Replace hose on exhaust cooling.
Lifesaving
Issued 10 August 1999
Resolved
Remove oil from bilges.
Fire Fighting
Issued 10 August 1999
Resolved
Repair fixed fire fighting system.
Navigation
Issued 10 August 1999
Resolved
Install hanger on steering cable to lift off the shaft.
Engineering
Issued 10 August 1999
Resolved
Replace hose on main engine raw water pump discharge.
Electrical
Issued 10 August 1999
Resolved
Install cover on ship service battery.
Lifesaving
Issued 10 August 1999
Resolved
Life ring repair waterlight.
Engineering
Issued 15 July 1996
Resolved
REPLACE FLAME SHIELD FOR RACOR FUEL FILTER.
Construction/Loadline
Issued 15 July 1996
Resolved
EXPOSE INTENAL AREA OF TRANSOM AND BOTTOM FRAMING, AFT AREA. TO BE COMPLETED FALL DRYDOCK.
Construction/Loadline
Issued 12 July 1989
Resolved
MAKE TEMPORARY REPAIRS AS NECESSARY TO MAKE THE REAR COCKPIT SEAT SECURE, PRIOR TO 26 JULY 89. REMOVE AND REBUILD DURING NEXT DRYDOCK PERIOD.
Construction/Loadline
Issued 12 July 1989
Resolved
CUT TO GOOD WOOD AND REPLACE ROTTEN FORWARD PORT CORNER POST AND ADJACENT WOOD AROUND WINDSHIELD, DURING NEXT DRYDOCK PERIOD.
Construction/Loadline
Issued 31 March 1988
Resolved
REPAIR UPPER SECTION OF STEM POST.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.