MAURY USCG vessel records
← All vessels

SCOUT

SCOUT is a 1970 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in June 2026, along with 14 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 25 June 2026.

Built
1970
Last inspected
25 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WYD9434
Flag
UNITED STATES
Maury page id
psix-50624

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

25 June 2026 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8413741
13 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090964
17 June 2025 COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090903
26 September 2024 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873730
20 June 2024 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7942742
16 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7826072
28 September 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7624439
16 December 2022 Deficiency Check · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7613385
7 July 2022 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411351
5 November 2021 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161165
19 August 2021 Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161414
1 July 2020 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6908349
5 November 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6849611
11 July 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637821
13 July 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375170
30 November 2017 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307560
13 July 2017 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105939
7 July 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830695
7 April 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829321

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 November 2025 Resolved
At each inspection, the owner or managing operator shall have the vessel ready for inspections of the hull structure and its appurtenances. A crack was identified in the hull gel coat with water weeping approximately 1 inch above the keel on the port side below the transducer. Grind the gel coat back and prepare the area for further inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2026
Resolved 25 June 2026
Resolution: Area was repaired without further visits from CG. All sat. No major damaged was found according to rep.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 November 2025 Resolved
At each inspection, the owner or managing operator shall have the vessel ready for inspections of the hull structure and its appurtenances. Wood rot identified along aft steering gear hatch support frame. Renew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2026
Resolved 25 June 2026
Resolution: All damged wood was replaced in kind. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 November 2025 Resolved
At each inspection, the owner or managing operator shall have the vessel ready for inspections of the hull structure and its appurtenances. Initial signs of wood rot/angel hair was identified along the interior port side of the transom and frames. Clean the affected area and preserve against further decay.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2026
Resolved 25 June 2026
Resolution: Area was cleaned. No additional damage noted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 November 2025 Resolved
At each inspection, the owner or managing operator shall have the vessel ready for inspections of the hull fittings and sea valves. Provide the sea valve for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2026
Resolved 25 June 2026
Resolution: Provided and tested. All sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 September 2023 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel did not have means to secure ventilation to engine space on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 25 October 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 28 September 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff markings were barely legible and need to be re-stenciled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2023
Resolved 25 October 2023
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 July 2022 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space...and may require the vsl to be dry docked to assess the extent of the damage. Found wood rot on a starboard bottom plank located in the forward compartment, in way of the previously plugged through-hull fitting. Vessel is directed to submit a repair proposal to adequately address noted rot to the satisfaction of the attending CGMI during winter haul out period of 2022-2023, no later than March 01, 2023. 46 CFR 176.600(d) NVIC 07-95
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2023
Resolved 30 December 2022
Resolution: See Activity Number 7613385
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 7 July 2022 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space...and may require the vsl to be dry docked to assess the extent of the damage. Found a wooden plug in what appears to be a keel bolt pilot hole; located in the engine compartment, directly aft of the transverse frame that has the exhaust manifold strapped down to it. Vessel is directed to haul the vessel, make determination with the attending marine inspector if the plug is covering a missing keel bolt, no later than March 01, 2023. 46 CFR 176.600(d) NVIC 07-95
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 March 2023
Resolved 3 January 2023
Resolution: See Activity Number 7613385
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 August 2021 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3ft but not more than 6ft in length. Line is worn and falling apart.
Action required: 10 - Deficiency Rectified
Resolved 19 August 2021
Resolution: replaced line to waterlight and remarked.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 July 2020 Resolved
Magnetic compass was inoperable. Replace magnetic compass.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2020
Resolved 7 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2020 Resolved
Vessel's sound signal was inoperable. Provide sound signals.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2020
Resolved 7 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2020 Resolved
Bilge pump was inoperable. Provide bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2020
Resolved 7 July 2020
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 July 2017 Resolved
Missing brackets, utilizing hook and loop set up.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 18 July 2017
Resolution: Install new approved brackets on vessel.
Lifesaving › Lifefloat › Serviceable
Issued 13 July 2017 Resolved
Found lifefloat grab line rotten, ring not servicable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: New ring installed and proper labeling, withline and light.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.