Records from 1985 to 2014. Most recent: inspection, 6 June 2014.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
6 June 2014
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4880867
17 July 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4382601
5 July 2012
Simplified Stability Test · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4369511
13 June 2012
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4342918
4 June 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4333804
12 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4206249
2 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3225224
28 April 2008
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3193941
5 June 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2952245
8 June 2006
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2673704
1 June 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2375456
21 July 2004
Hull Examination · Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2140288
16 June 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1819118
1 May 2003
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1780624
24 April 2002
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1601068
14 June 2001
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1403426
18 May 2001
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1064186
3 May 2001
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1403425
11 May 2000
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1448135
13 May 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1424752
4 May 1999
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1372633
6 May 1998
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 788650
14 May 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1105735
9 May 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1093594
15 May 1996
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1088194
17 May 1995
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1236877
18 May 1994
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1382770
2 May 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1456161
19 May 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1401718
13 May 1992
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 953604
15 May 1991
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 905716
15 May 1990
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1240734
3 May 1989
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1208901
27 May 1988
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1194513
20 July 1987
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1333135
7 March 1987
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1027283
23 May 1986
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 990204
23 May 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1292029
6 May 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1288133
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 6 June 2014
Resolved
Shaft seal leaking excessively, repair.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 16 July 2014
Resolution: Seal was tightened to bring leak to acceptable limit.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 June 2014
Resolved
Fire extinguisher not mounted properly. Mound with approved bracket.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 16 July 2014
Resolution: Mounting bracket was replaced and properly installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 June 2014
Resolved
Stern light inoperable. Make repairs.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 16 July 2014
Resolution: Stern light bulb was replaced and tested SAT.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 June 2014
Resolved
Bolts missing/lose on railing. Repair.
Action required: 705 - Other - as specified
Due 18 June 2014
Resolved 16 July 2014
Resolution: Bolts were installed and railing was secure.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 June 2014
Resolved
Drills not conducted due to master lack of knowledge. Train, conduct drills in presence of CGMI.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 16 July 2014
Resolution: Training was conducted by yacht club steward and drills were SAT.
Engineering › Fuel Oil Service System › Piping
Issued 6 June 2014
Resolved
Fuel shut offs not labeled. Lable fuel shut-offs.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 16 July 2014
Resolution: Fuel shut off label was added. SAT.
Documentation › Certificates/Documents › Stability Letter
Issued 4 June 2012
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 5 July 2012
Resolved 5 July 2012
Resolution: Completed sat simplified stabilty test.
Documentation › Certificates/Documents › Stability Letter
Issued 12 December 2011
Resolved
THE VESSEL'S OWNER/OPERATOR HAS NOT REQUESTED AN INITIAL OR UPDATED STABILITY LETTER OR HAS NOT CERTIFIED COMPLIANCE WITH THE REVISED STABILITY CRITERIA FOR ASSUMED AVERAGE WEIGHT PER PERSON (AAWPP) OF 185 POUNDS. TO VERIFY COMPLIANCE, A STABILITY TEST MUST BE COMPLETED. BASED UPON A WEIGHT RATIO CALCULATION, THE VESSEL'S CAPACITY IS THERFORE LIMITED TO: 15 PERSONS(PASSENGERS AND CREW)
Action required: 705 - Other - as specified
Due 1 June 2012
Resolved 4 June 2012
Resolution: VESSEL DID NOT COMPLY WITH REQUIREMENT. NEW CG-835 WITH DUE DATE OF 05 JULY 2012. COI WILL BE REVOKED IF REQUIREMENT NOT MET BY 7/05/2012.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 July 2004
Resolved
Provide linkage from the pull cable to the fixed fire extinguisher.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 August 2004
Resolved 6 August 2004
Engineering › Steering Gear System › Rudder
Issued 8 July 2004
Resolved
Secure rudder in the skeg.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 19 July 2004
Resolution: Proper retaining collar installed on the rudder shaft.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 8 July 2004
Resolved
Unclog the through hull intake screen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 19 July 2004
Resolution: Paint removed from the intake screen.
Accommodation/Occupational Safety › Ventilation › General
Issued 8 July 2004
Resolved
Replace crushed and torn ventilation piping in the peak void space.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 19 July 2004
Resolution: Ventilation hoses replaced.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 8 July 2004
Resolved
Fasten hand grab, behind steering station, to the gunwal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 19 July 2004
Resolution: Hand grab refastened to the gunwal.
Engineering › Sea-water System (primary cooling) › Valve
Issued 8 July 2004
Resolved
Prove proper operation of the through hull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 July 2004
Resolved 19 July 2004
Resolution: Wittnessed the proper operation of the through hull.
Fire Fighting › Ventilation Systems
Issued 24 April 2002
Resolved
Seal around vents in engine room compartment.
Due 8 May 2002
Resolved 22 May 2002
Resolution: Area around vents were properly sealed.
Engineering › Fuel Oil Service System
Issued 24 April 2002
Resolved
Label emergency fuel shutoff.
Due 8 May 2002
Resolved 22 May 2002
Resolution: Shut Off properly labeled.
Fire Fighting
Issued 13 May 1999
Resolved
Prior to carrying more than six passengers, install a fixed firefighting system IAW 46 CFR 181.420 but no later than 15 Jun 1999. To be completed to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Fire Fighting
Issued 18 May 1994
Resolved
PROVE PROPER OPERATION OF FIRE PUMP.
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Lifesaving
Issued 19 May 1993
Resolved
AFFIX LABEL TO SHOW WHERE CHILD SIZE PFDS ARE STORED.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Electrical
Issued 19 May 1993
Resolved
REWIRE VHF RADIO CIRCUIT.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Documentation
Issued 19 May 1993
Resolved
OBTAIN AND MAINTAIN FILE OF ORIGINAL CG LICENSES FOR ALL LAUNCH OPERATORS.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Lifesaving
Issued 19 May 1993
Resolved
PROVIDE THREE (3) ADDITIONAL ADULT TYPE I PFDS.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993