Behind this panel: 17 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 17
8 June 2026
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8376398
7 May 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8328805
9 June 2025
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8126751
10 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7911259
1 May 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7888608
12 June 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7670076
6 June 2022
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7418648
2 May 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7418652
2 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7213319
18 June 2020
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6986327
8 June 2020
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6971454
10 July 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6744036
31 July 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6496602
10 May 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6410658
6 July 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6200102
22 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5915093
9 May 2016
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5872706
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 9 June 2025
Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Operator was not logging passenger count prior to and after each voyage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 August 2025
Resolved 28 July 2025
Resolution: OCMI made policy decision regarding passenger counts. Vessel in compliance.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2024
Resolved
A vessel of not more than 26 feet in length must carry a minimum of one life buoy of not less than 20 inches in diameter. At the time of inspection, the vessel's ring life buoy was found to be significantly deteriorated, and should be replaced with a ring meeting the requirements of this subpart.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2024
Resolved 14 June 2024
Resolution: Operator purchased new a 20" USCG approved lifering. USCG Approval Number 160.050/48/2. MI received objective evidence (photograph) of new life ring onboard. See deficiency documents section for details.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2023
Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets, with an attached lanyard, placed so as to be easily available during an emergency. The words "FIRE BUCKET" must be stenciled in a contrasting color on each bucket. The vessel did not have the required three fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 23 June 2023
Resolution: Vessel operator procured required number of fire buckets.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 2 June 2021
Resolved
Drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:
(1) Date of the drill and training; and
(2) General description of the drill scenario and training topics.
Vessel did not have a updated drill record. Conduct and properly log required drills.
Action required: 10 - Deficiency Rectified
Due 2 June 2021
Resolved 2 June 2021
Resolution: CONDUCTED AND PROPERLY LOGGED DRILLS AS REQUIRED.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2021
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Life ring not did not have retroflective tape. Provide required retroflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 4 June 2021
Resolution: Proper retroreflective material applied to the vessels life float.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 June 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:
(1) Charts of large enough scale to make safe navigation possible;
(2) U.S. Coast Pilot or similar publication;
(3) Coast Guard Light List;
(4) Tide tables; and
(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority.
(b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication.
No updated charts or publications onboard. Provided updated charts and pumlications as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 4 June 2021
Resolution: Proper corrected charts and pumbs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2020
Resolved
Each ring buoy must meet 46CFR160.050. The grab lines on the vessel's ring buoy are deteriorated an unserviceable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 8 July 2020
Resolution: Verified the presence of a new ring buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2019
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that it has a positive shutoff valve installed at the hull penetration. The line leading from the vessel's submersible electric pump lacks a stop valve at the hull
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 29 July 2019
Resolution: Observed picture of installed stop valve.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 July 2019
Resolved
Each vessel must be equipped with at least two operable portable battery lights. The vessel is missing the two required lights.
46CFR183.430
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 29 July 2019
Resolution: Viewed image of the required two portabale lights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 July 2019
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The vessel's first aid kit's contents are expired.
46CFR184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2019
Resolved 29 July 2019
Resolution: Observed image of new first aid kit.
Lifesaving › Lifebuoys › Serviceable
Issued 6 July 2017
Resolved
Grabline was dertiorated. Renew.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 12 July 2017
Resolution: Rcvd email stating def was corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 July 2017
Resolved
Epired meds in first aid kit. Renew.
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 12 July 2017
Resolution: Rcvd email stating def was corrected.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 June 2016
Resolved
ST01- Properly mark stowage of adult and child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 18 July 2016
Resolution: Recieved pictures of renewed life jacket stowage markings.
Engineering › Fuel Oil Service System › Filter
Issued 22 June 2016
Resolved
The fuel filter was not fitted with flame impingement bowl. ST01- Provide flame impingement bowl for fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 18 July 2016
Resolution: Recieved pictures of newly installed flame bowl.