← All vessels
SIGMAGAS
SIGMAGAS is a 1998 tank ship. The Coast Guard has recorded 29 inspections since 1999, most recently in June 2022, along with 10 deficiencies and 5 operational controls.
Records from 1999 to 2022. Most recent: inspection, 17 June 2022.
- Built
- 1998
- Last inspected
- 17 June 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9183568 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2MQ
506327
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-506327
Inspections, by type
…with no type recorded4
Years with a record
15 calendar years (1999–2022)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9736 - Displacement, Ton
6051 - Convention (Subpart B), Gross Ton
7876 - Dead Weight, Metric Ton
2398 - Convention (Subpart B), Net Ton
6051 - Convention (Subpart B), Gross Ton
7876 - Dead Weight, Metric Ton
2398 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
17 June 2022
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7480051
29 December 2020
COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7117049
19 November 2019
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6845846
10 September 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6808314
26 August 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6794803
23 June 2019
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6704772
18 June 2019
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6717762
23 May 2019
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6687454
13 November 2018
COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 6571414
27 November 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6343018
4 September 2017
COC-GAS Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6256308
24 March 2017
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6111220
23 August 2016
ISPS II Exam · Ballast Water Examination · COC-GAS Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5976203
1 October 2015
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5733646
6 September 2015
Ballast Water Examination · ISPS II Exam · COC-GAS Annual
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5236453
14 August 2014
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4952425
18 February 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4246822
3 December 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4200965
20 August 2011
Administrative Inspection · Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam · COC-GAS Annual
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4121432
17 August 2011
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4116031
19 November 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3894691
5 March 2010
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3690374
18 January 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3665680
30 July 2009
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3550921
13 July 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3266292
25 May 2002
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1619022
24 May 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1622213
1 November 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 434700
1 November 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 805892
Deficiency record · 10
Deck/Cargo › Cargo Condition › Bulk Liquefied Gas
Issued 4 September 2017
Resolved
Liquified gasses in bulk - On ships carrying flammable or toxic products or both, a water-spray system for cooling, fire prevention and crew protection should be installed to cover boundaries of unmanned forecastle structures not containing high fire risk items or equipment do not require water-spray protection. Forward bosun hole did not have adequate coverage. Repair prior to cargo loading. 10 c
Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 23 August 2016
Resolved
1840 - Instrumentation - The alarms of the vapor space of each cargo tank should be activated before the set pressures are reached. Vessels alarm PLC is not functional as of 23JUN2016.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 23 August 2016
Resolved
0114 - Cargo Ship Safety - Electrical installations should be such as to minimize the risk of fire and explosion from flammable products. CT1 discharge pump motor number 2 had 2 loose cable conductors hanging from stuffing tubes from electrical connection box.
Lifesaving › Lifebuoys › Stowage
Issued 23 August 2016
Resolved
0650 - Lifebuoys - Lifebuoys shall be so stowed as to be capable of being rapidly cast loose and not permanently secured in any way. Lifebuoys were secured by line to brackets.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 September 2015
Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be reasonably gastight and self-closing. Three A-60 doors failed to lash to completely close the doors. SOLAS 74(01 Cons.) II-2/47.1
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 11 September 2015
Resolved
The system shall be capable of delivering inert gas with an oxygen content of not more than 5% to the cargo tanks. Inert Gas Generator was not capable of providing oxygen at the required percentage. SOLAS 74(01 Cons.) II-2/62.3.2
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 15 August 2011
Resolved
It was reported that the shaft seal was leaking sea water into the bilge, and that there MAY be line wrapped around the propeller shaft causing the leak. There was no loss of propultion reported.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 25 May 2002
Resolved
Provide report attesting to the proper operation of the cargo tank safety relief valves. (4.0) BAR, Current Report. LEGACY COMPONENT DESC: Relief Valve
Deck/Cargo › Holds/Tanks
Issued 25 May 2002
Resolved
Prove proper operation and calibration of the fixed gas detection system to the satisfaction of the administration. LEGACY COMPONENT DESC: Fixed Gas Detection
Deck/Cargo
Issued 1 November 1999
Resolved
PRIOR TO ENTERING NEXT U.S. PORT, PROVIDE EVIDENCE THAT THE ANNUAL HYDROSTATIC TEST HAS BEEN CONDUCTED ON THE CARGO PIPING BY THE CLASS SOCIETY.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.