Records from 2019 to 2026. Most recent: inspection, 23 May 2026.
Inspection history · 5
23 May 2026
PSC A · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8378810
16 November 2022
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7593857
28 March 2022
PSC B · Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7418626
23 March 2022
Deficiency Check · Ballast Water Examination · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7416537
25 February 2019
PI Safety Exam · ISPS I Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6629445
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 March 2022
Resolved
THE ACTIVATION OF ANY DETECTOR OR MANUALLY OPERATED CALL POINT SHALL INITIATE A VISUAL AND AUDIBLE FIRE SIGNAL AT THE CONTROL PANEL AND INDICATING UNITS. IF THE SIGNALS HAVE NOT RECEIVED ATTENTION WITHIN 2 MIN AN AUDIBLE ALARM SHALL BE AUTOMATICALLY SOUNDED THROUGHOUT THE CREW ACCOMODATION AND SERVICE SPACES, CONTROL STATOPMS AND MACHINERY SPACES OF CATEGORY A. FIRE ALARM IS INAUDIBLE FROM CREW ACCOMODATIONS.
74 SOLAS (97) II-2/13.1.4
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2022
Resolved 26 March 2022
Resolution: Deficiency corrected and approved by class.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 23 March 2022
Resolved
THE ALTERNATIVE MEANS TO BE PROVIDED IN ACCORDANCE WITH THE PROVISIONS OF PARAGRAPH 3.3.3 SHALL BE AN INDEPENDENTLY DRIVEN, POWER-OPERATED EMERGENCY FIRE PUMP. EMERGENCY FIRE PUMP IS INOPERABLE.
74 SOLAS (97) II-2/4.3.3.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 4 April 2022
Resolution: Deficiency corrected and approved by class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 March 2022
Resolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. HOWEVER, HOLD-BACK ARRANGEMENTS FITTED WITH REMOTE RELEASE DEVICES OF THE FAIL-SAFE TYPE MAY BE UTILIZED. STAIRWELL DOOR ON DECK B HAS A REMOTE RELEASE DEVICE THAT IS INOPERABLE.
74 SOLAS (97) II-2/47
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 28 March 2022
Resolution: Deficiency corrected and approved by class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 March 2022
Resolved
THE FIRE RESISTANCE OF DOORS SHALL. AS FAR AS PRACTICABLE, BE EQUIVALENT TO THAT OF DOORS SHALL, AS FAR AS PRACTICABLE, BE EQUIVALENT TO THAT OF THE DIVISION IN WHICH THEY ARE FITTED. FIRE DOOR IN GALLEY DOES NOT LATCH, CREATING INSUFFICIENT BOUNDARY.
74 SOLAS (97) II-2/47
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 28 March 2022
Resolution: Deficiency corrected and approved by class.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 23 March 2022
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9, OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. DURING DECK WALK, PSCOs OBSERVED A LEAK ON THE PORT SIDE HYDRAULIC LINE.
74 SOLAS (20) I-11(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 28 March 2022
Resolution: Deficiency corrected and approved by class.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 March 2022
Resolved
EFFICIENT GUARD RAILS OR BULWARKS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. STARBOARD SIDE AFT CRANE DECK WAS MISSING GUARD RAILS.
ILLC (88 Proto) 25.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 April 2022
Resolved 28 March 2022
Resolution: Deficiency corrected and approved by class.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 March 2022
Resolved
THE SECRETARY MAY ORDER ANY VESSEL, IN A PORT OF PLACE SUBJECT TO THE JURISDICTION OF THE U.S. OR IN THE NAVIGABLE WATERS OF THE U.S., TO OPERATE OR ANCHOR IN A MANNER THE SECRETARY DIRECTS IF – BY REASON OF WEATHER. VISIBILITY, SEA CONDITIONS, PORT CONGESTION, OTHER HAZARDOUS CIRCUMSTANCES, OR THE CONDITION OF SUCH VESSEL. THE SECRETARY IS SATISFIED SUCH DIRECTION IS JUSTIFIED IN THE INTEREST OFSAFETY … HOSPITAL SPACE WAS INHABITED BY CREW MEMBER.
46 USC 70002(3)
Action required: 10 - Deficiency Rectified
Resolved 23 March 2022