MAURY USCG vessel records Sign in
← All vessels

JUBILEE

JUBILEE is a 1999 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 2000, most recently in December 2025, along with 39 deficiencies and 1 casualty investigation in 2006.

Records from 2000 to 2025. Most recent: inspection, 4 December 2025.

Built
1999
Last inspected
4 December 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB5013
506386
Flag
UNITED STATES
366904830
Maury page id
psix-506386

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (2000–2025)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)74.4 ft × 19.7 ft × 7.3 ft
Registered tonnagegross 71 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE, INC. · PANAMA CITY, FL, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB5013MMSI 366904830 · active · compulsorily equipped · granted 22 August 2023, expires 16 August 2033
WDA2182MMSI not assigned · expired · voluntarily equipped · granted 5 September 2000, cancelled 6 November 2010
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

M/V AMERICA Industrial Vessel · MISLE 71515 · 17 February 2006 · activity 2593252

Inspection history · 37

4 December 2025 Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8276091
18 November 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8270581
18 August 2025 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8212654
12 November 2024 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8031871
20 November 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7827408
15 November 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7825466
17 November 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7596080
1 December 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7360291
17 November 2021 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7353074
19 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7335501
16 November 2020 Administrative Inspection · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7096394
16 October 2019 In-Service Inspection · DAPI Audit · Hull Examination · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6835887
14 November 2018 Damage Survey · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6580550
6 December 2017 Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6314979
15 November 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6307180
14 November 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6040415
7 December 2015 Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5776499
17 November 2015 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5765608
9 December 2011 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4203094
10 November 2010 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3886952
3 December 2009 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3635456
19 November 2008 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3363300
14 December 2007 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115840
17 February 2006 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2593252
1 December 2005 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2544269
15 November 2005 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2535011
15 December 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2261185
18 November 2004 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2243439
24 August 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2174837
27 January 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1992816
6 October 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1924864
10 September 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1867268
16 April 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1605230
11 March 2002 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1495194
11 March 2002 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1847783
18 October 2001 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1437967
22 June 2000 Inclining Experiment · Hull Examination · Initial Construction-Excluding Oversight · Initial Certification
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1422140

Deficiency record · 39

10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 November 2020 Resolved
Provide proof of a current rules of the road book.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2020
Resolution: Owner provided proof of NAV rules.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 16 November 2020 Resolved
Various deck lighting covers missing throughout. Properly install shatter proof cages throughout.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2020
Resolved 30 November 2020
Resolution: Owner installed approved light cages.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 November 2020 Resolved
Fire station missing spanner wrench. Provide a spanner wrench.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2020
Resolution: Owner provide proof of spanner wrench.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2019 Resolved
Vessel was not made available to conduct in-service inspection. Vessel is prohibited from carrying passengers overnight until vessel completes in-service inspection to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 October 2019
Resolved 13 November 2019
Resolution: In-service inspection conducted.
Engineering › Steering Gear System › Trunnion Block
Issued 15 November 2017 Resolved
Renew vessel rudder block and table.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2017
Resolved 15 December 2017
Resolution: Vessel replaced rudder table
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 7 December 2015 Resolved
Replace port adn stbd cutlass bearing.
Action required: 705 - Other - as specified
Due 21 December 2015
Resolved 9 December 2015
Resolution: Vessel replaced both bearings.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 7 December 2015 Resolved
Replace port side sewage skin valve. Prior to receiving hull credit
Action required: 705 - Other - as specified
Due 21 December 2015
Resolved 9 December 2015
Resolution: Vessel replaced valve.
Engineering › Bilge Water Management System › Piping
Issued 7 December 2015 Resolved
Replace A/C compartment bilge foot piping
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 December 2015
Resolved 9 December 2015
Resolution: Vessel replaced piping
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 December 2015 Resolved
Repair strip trim to entrance to both berthing areas.
Action required: 705 - Other - as specified
Due 21 December 2015
Resolved 9 December 2015
Resolution: Vessel repaired trim.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 November 2008 Resolved
Demonstrate proper operation of fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2008
Fire Fighting › Fire Pumps › Pressure
Issued 19 November 2008 Resolved
Provide pressure gauge for fire pump.
Due 19 December 2008
Resolved 20 November 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 November 2005 Resolved
Provide B-II fire extinguisher IAW COI vice the B-I for a total of 3 (B-II's) and 1 (B-I). 46CFR176.810
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 22 November 2005
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 15 November 2005 Resolved
Provide copy of Inland Navigation Rules as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 22 November 2005
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 15 November 2005 Resolved
Provide proper glass port side bridge windows as required by 46 CFR 177.1010.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 December 2005
Resolved 22 November 2005
Lifesaving › Lifebuoys › Serviceable
Issued 18 November 2004 Resolved
Replace wasted grab lines on life buoys, main deck, port & stbd. (46 CFR 180.70)
Action required: 705 - Other - as specified
Due 18 December 2004
Resolved 15 December 2004
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 November 2004 Resolved
Demonstrate proper operation of emergency lighting fixtures in all passenger accomodations located below the main deck. (46 CFR 183.432)
Action required: 705 - Other - as specified
Due 18 December 2004
Resolved 15 December 2004
Resolution: Corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Fire Fighting › Fire Main › Condition
Issued 24 August 2004 Resolved
Prove proper operation of fire pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2004
Resolved 24 August 2004
Resolution: Ship''''s Service generator voltage regulator was adjusted to provide proper voltage to motor. Test SAT under load for 10 mins.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 August 2004 Resolved
Install cover on open electrical box in machinery space.
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 24 August 2004
Engineering › Bilge Water Management System › Strainer
Issued 24 August 2004 Resolved
Install strainer in machinery space fixed bilge suction pump.
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 24 August 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 August 2004 Resolved
Repair machinery guard on starboard main engine.
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 24 August 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 August 2004 Resolved
Prove proper operation of SME fire fighting shutdown.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2004
Resolved 24 August 2004
Resolution: Adjusted travel of fuel oil shutdown solenoid plunger. Tested SAT.
Stability › Watertight Integrity
Issued 27 January 2004 Resolved
Renew sewage valve discharge stbd through hull. Renew with like kind valve. LEGACY COMPONENT DESC: Sewage Discharge Valve
Action required: 705 - Other - as specified
Due 27 February 2004
Resolved 28 January 2004
Resolution: Owner renewed sewage valve discharge stbd through hull. Renewed with like kind valve.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 September 2003 Resolved
Have fixed fire system weighed and provide weight and service report to MSFO Panama City. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 10 September 2003
Resolved 10 September 2003
Resolution: Owner provided weight and service report by Brown''''s Fire Protection Service, prior to completion of inspection.
Electrical › Lighting (service)
Issued 10 September 2003 Resolved
Remove light fixtures and install marine grade lighting fixtures. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 6 October 2003
Resolution: Owner installed marine grade lighting fixtures.
Engineering › Steering Gear System
Issued 10 September 2003 Resolved
Double nut steering cross connect. LEGACY COMPONENT DESC: Linkage
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 6 October 2003
Resolution: Owner double nutted steering cross connect.
Electrical › Electric Supply System (service)
Issued 10 September 2003 Resolved
Properly strap wire ways in fwd potable water room. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 6 October 2003
Resolution: Owner properly strapped wire ways in water room.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 September 2003 Resolved
Post "Emergency Exit Keep Clear" signs at each means of escape. LEGACY COMPONENT DESC: Emergency Exit
Action required: 705 - Other - as specified
Due 10 October 2003
Resolved 6 October 2003
Resolution: Owner posted proper signs at each means of escape.
Documentation › Certificates/Documents
Issued 18 October 2001 Resolved
Provide for review, to the satisfaction of the attending U.S. Coast Guard marine inspector, a valid Certificate of Documentation. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 18 November 2001
Resolved 18 October 2001
Documentation › Certificates/Documents
Issued 18 October 2001 Resolved
Provide and post stability letter on board vessel as required by 46 CFR 176.306. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Due 18 November 2001
Resolved 11 March 2002
Resolution: Stability Letter posted.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 18 October 2001 Resolved
Provide evidence that fixed fire suppression has been maintained and serviced in accordance with 46 CFR 176.810(b). LEGACY COMPONENT DESC: Annual Servicing
Due 18 November 2001
Resolved 11 March 2002
Resolution: Maintenance certs provided.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 18 October 2001 Resolved
Repair and prove operation of propulsion engine control system in accordance with 46 CFR 184.620. LEGACY COMPONENT DESC: Control System
Due 18 November 2001
Resolved 11 March 2002
Resolution: Main engines tested.
Fire Fighting › Means of Escape
Issued 18 October 2001 Resolved
Properly mark emergency means of escape in forward accommodation space in accordance with 46 CFR 177.500. LEGACY COMPONENT DESC: Escape Route Signs
Condition: Unknown
Due 18 November 2001
Resolved 11 March 2002
Resolution: Escape labled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 18 October 2001 Resolved
Provide evidence of maintenance and servicing of all portable fire extinguishers in accordance with 46 CFR 176.810. LEGACY COMPONENT DESC: Service
Condition: Unknown
Due 18 November 2001
Resolved 11 March 2002
Resolution: Portable extinguishers serviced.
Accommodation/Occupational Safety › Occupational Safety
Issued 18 October 2001 Resolved
Provide and install machinery guard on starboard main diesel engine flywheel in accordance with 46 CFR 177.960 LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 18 November 2001
Resolved 11 March 2002
Resolution: Machinery guards installed.
Engineering › Bilge Water Management System
Issued 18 October 2001 Resolved
Remove existing flexible non-metallic hose with flexible non-metallic hose that meets the standards set forth in 46 CFR 182.710. LEGACY COMPONENT DESC: Hose
Due 18 November 2001
Resolved 11 March 2002
Resolution: Flexable hoses replaced with approved.
Engineering › Bilge Water Management System
Issued 18 October 2001 Resolved
Repair and prove opeartion of bilge pump located in engine room as required by 46 CFR 176.804 LEGACY COMPONENT DESC: Pump
Due 18 November 2001
Resolved 11 March 2002
Resolution: Bilge pump repaired and tested.
Communications › Alarms/Indicators
Issued 18 October 2001 Resolved
Repair and prove operation of bilge high level alarm located in lazarette as required by 46 CFR 182.530. LEGACY COMPONENT DESC: Bilge Alarm
Due 18 November 2001
Resolved 11 March 2002
Resolution: Bilge alarms repaired and tested.
Electrical › Electrical Distribution System (service)
Issued 18 October 2001 Resolved
Properly support 110 vac electrical wiring throughout the vessel in accordance with 46 CFR 183.340. LEGACY COMPONENT DESC: Wiring
Due 18 November 2001
Resolved 11 March 2002
Resolution: Wiring supported properly.
Fire Fighting › Fire Pumps
Issued 18 October 2001 Resolved
Repair and prove operation of fire pump in accordance with 46 CFR 176.810.
Due 18 November 2001
Resolved 11 March 2002
Resolution: Fire pump repaired and tested.

Casualty record · 1

17 February 2006Routine · role: Involved in a Marine Casualty · activity 2593252
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.