Records from 1985 to 1999. Most recent: inspection, 30 November 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
30 November 1999
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 810875
22 January 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788218
23 June 1998
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1424614
12 September 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828957
20 March 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078704
11 July 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1184250
26 June 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 882723
13 April 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853108
18 April 1994
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1167198
12 April 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145804
3 April 1992
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268576
2 April 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1268577
29 August 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231569
9 July 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931821
14 April 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210539
15 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1043280
10 September 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1312683
28 July 1987
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336526
6 August 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001804
28 June 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 984628
5 April 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994148
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 January 1999
Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 22 January 1999
Resolved 23 June 2001
Resolution: COI deactivated and def was never cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 January 1999
Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 11 March 1999
Resolved 23 June 2001
Resolution: COI deactivated and def was never cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 January 1999
Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 11 March 1999
Resolved 23 June 2001
Resolution: COI deactivated and def was never cleared.
Construction/Loadline › Hull › Hull Plating
Issued 23 June 1998
Resolved
Repair cracks in deck IWO forward hatch.
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI deactivated and def never cleared.
Documentation › Manuals/Policy Documentation › Company Action Plan (SIP)
Issued 23 June 1998
Resolved
Provide proof of current enrollment in DAPI program._x001C_
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI deactivated and def was never cleared.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 23 June 1998
Resolved
Properly connect fuel fill pipe ground._x001C_
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI Deactivated and def never cleared.
Construction/Loadline › Hull › Hull Plating
Issued 23 June 1998
Resolved
Repair holes IWO vsl perimeter rub rail.
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI deactivated and def never cleared.
Construction/Loadline › Hull › Hull Plating
Issued 23 June 1998
Resolved
Repair hole inner port forward deck box.
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI deactivated and def never cleared.
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 June 1998
Resolved
Repair rotted wood at #1 port and stbd side longitudinal frames IWO seating/pole racks.
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI deactivated and def was never cleared.
Engineering › Diesel Engine (propulsion-electric) › Blower, Centrifugal
Issued 23 June 1998
Resolved
Properly install vent blower interlock with engine starter, provide warningsign and properly route/make gas tight ducting.
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI Deactivated and def never cleared.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 23 June 1998
Resolved
Make fuel shutoff valve at tank operational and label.
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI Deactivated.
Construction/Loadline › Penetrations › Pipe Flange
Issued 23 June 1998
Resolved
Cap unused stern bilge overboard.
Condition: Unknown
Due 23 July 1998
Resolved 23 June 2001
Resolution: COI deactivated and def was never cleared.
Engineering
Issued 26 June 1995
Resolved
SECURE FUEL TANK GROUNDING CABLE.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Lifesaving
Issued 26 June 1995
Resolved
REPAIR INSTALLED HAND OPERATED BILGE PUMP.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Engineering
Issued 26 June 1995
Resolved
REPAIR DAMAGED FUEL VENT FLAME SCREEN.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Engineering
Issued 26 June 1995
Resolved
LABLE "EMERGENCY FUEL SHUT OFF" VALVE.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Fire Fighting
Issued 26 June 1995
Resolved
PROVIDE HAND OPERATED FIRE PUMP.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Engineering
Issued 9 July 1990
Resolved
PROVIDE FUEL VENT FLAME SCREEN.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Navigation
Issued 9 July 1990
Resolved
REPACK OR TIGHTEN RUDDER STUFFING TUBE.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Engineering
Issued 9 July 1990
Resolved
PROVIDE METAL NON-RETURN VALVE FOR BILGE OVERBOARD DISCHARGE.
Condition: Unknown
Due 9 July 1990
Resolved 9 July 1990
Engineering
Issued 15 March 1989
Resolved
REPLACE FILL PIPE FLEXIBLE COUPLING.
Condition: Unknown
Due 15 March 1989
Resolved 15 March 1989
Engineering
Issued 15 March 1989
Resolved
REPAIR DAMAGED AREA TO FUEL LINE.
Condition: Unknown
Due 15 March 1989
Resolved 15 March 1989
Fire Fighting
Issued 28 July 1987
Resolved
PROVIDE VALVES FOR OVERBOARDS OFF ALL BILGE PUMPS AT HULL.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Electrical
Issued 28 July 1987
Resolved
PROPERLY MOUNT PANEL BOARD AT PILOT STATION.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Electrical
Issued 28 July 1987
Resolved
PROVIDE INDICATOR LIGHT FOR AUTOMATIC OPERATION OF BILGE PUMP.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987
Resolved
PROVIDE LIGHT FOR RING BUOY, ATTACHED TO RING BUOY.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Electrical
Issued 28 July 1987
Resolved
PROVIDE PROPER BATTERY BOX.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987
Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Engineering
Issued 28 July 1987
Resolved
REDUCE LEAKAGE THROUGH STERN TUBE.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Engineering
Issued 28 July 1987
Resolved
MARK EMERGENCY FUEL SHUT-OFF.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987