Records from 1985 to 1995. Most recent: inspection, 28 June 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
28 June 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1191595
25 June 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158004
14 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938158
3 August 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952998
10 July 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955170
9 January 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1266682
18 July 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936334
9 July 1990
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927752
27 December 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232130
30 November 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902423
7 November 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334347
20 September 1989
COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330443
30 August 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997796
23 May 1988
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1042949
3 May 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202713
9 June 1987
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010216
16 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999945
2 April 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 999943
10 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289401
Electrical
Issued 3 August 1992
Resolved
REPLACE BATTERY IN EMERGENCY FLASHLIGHT.
Condition: Unknown
Due 3 August 1992
Resolved 11 August 1992
Construction/Loadline
Issued 3 August 1992
Resolved
REPAIR/REPLACE AND PROVE SATISFACTORY OPERATION OF FWD ACTIVATED_x001C_ ELECTRIC BILGE PUMP.
Condition: Unknown
Due 11 August 1992
Resolved 11 August 1992
Documentation
Issued 3 August 1992
Resolved
PROVIDE VALID FCC SHIP STATION CERTIFICATE.
Condition: Unknown
Due 3 August 1992
Resolved 11 August 1992
Construction/Loadline
Issued 3 August 1992
Resolved
TIGHTEN/REPLACE PROPELLER SHAFT PACKDING GUARD TO STEM FLOW OF WATER INTO BILGE.
Condition: Unknown
Due 3 August 1992
Resolved 11 August 1992
Navigation
Issued 3 August 1992
Resolved
REPLACE PORT NAVIGATION RUNNING LIGHT WITH PROPERLY SHIELDED FIXTURE.
Condition: Unknown
Due 11 August 1992
Resolved 11 August 1992
Construction/Loadline
Issued 3 August 1992
Resolved
ADJUST BOTY PROP SHAFT AND RUDDER POST PACKING GLANDS TO STOP WATER FROM LEAKING INTO BOAT WHEN VSL IS NOT IN OPERATION.
Condition: Unknown
Due 11 August 1992
Resolved 11 August 1992
Fire Fighting
Issued 10 July 1992
Resolved
PLACE ON BOARD A B-I FIRE EXTINGUISHER APPROVED FOR MARINE USE AND MOUNT ACCORDINGLY.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Construction/Loadline
Issued 10 July 1992
Resolved
TIGHTEN/REPACK PROPELLER SHAFT PACKING GLAND TO STEM FLOW OF WATER INTO BILGE.
Condition: Unknown
Due 24 July 1992
Resolved 21 August 1992
Navigation
Issued 10 July 1992
Resolved
PROVIDE SUITABLE NAVIGATION/SIGNALING HORN FOR VSL.
Condition: Unknown
Due 24 July 1992
Resolved 21 August 1992
Documentation
Issued 10 July 1992
Resolved
PROVIDE VALID FCC SHIP STATION CERTIFICATE.
Condition: Unknown
Due 24 July 1992
Resolved 21 August 1992
Electrical
Issued 10 July 1992
Resolved
REPLACE BATTERY IN EMERGENCY FLASHLIGHT.
Condition: Unknown
Due 24 July 1992
Resolved 21 August 1992
Electrical
Issued 10 July 1992
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE ANCHOR LIGHT SWITCH.
Condition: Unknown
Due 10 July 1992
Resolved 10 July 1992
Documentation
Issued 18 July 1991
Resolved
PLACE ABOARD PLACARDS FOR DISCHARGE OF OIL, GARBAGE OVERBOARD, PLASTICS OVERBOARD, COMPLIANCE MAY BE PROVEN BY COPY OF INVOICE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Electrical
Issued 18 July 1991
Resolved
REMOVE WIRE NUTS FOR RADIO WIRING AND REPLACE WITH MARINE GRADE BULLET TYPECONNECTORS. COMPLIANCE MAY BE PROVEN BY COPY OF INVOICE.
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Lifesaving
Issued 20 September 1989
Resolved
RENEW REFLECTIVE TAPE ON ALL PFDS.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Lifesaving
Issued 20 September 1989
Resolved
PROVE PROPER OPERATION OF LIFE RING BUOY WATER LIGHT.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Engineering
Issued 20 September 1989
Resolved
REPLACE CG TYPE "A" FUEL HOSE WITH TYPE THAT SATISFIES 46 CFR 182.20-40(A) (2) OR REPLACE WITH COPPER TUBING OF A MINIMUM WALL THICKNESS OF .035 INCH.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Engineering
Issued 20 September 1989
Resolved
PROVE RACOR FUEL CONDITIONER IS A MARINE TYPE ACCEPTABLE TO THE COAST GUARDFOR USE ON INSPECTED VESSELS.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Engineering
Issued 20 September 1989
Resolved
PROVE NEW FUEL TANK CAN MEET THE REQUIREMENTS OF 46 CFR 182.20-25 AND CONDUCT TEST DESCRIBED THEREIN.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Lifesaving
Issued 20 September 1989
Resolved
PROPERLY MARK ALL PFDS.
Condition: Unknown
Due 20 September 1989
Resolved 20 September 1989
Lifesaving
Issued 30 August 1989
Resolved
RENEW REFLECTIVE TAPE ON ALL PFDS
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Lifesaving
Issued 30 August 1989
Resolved
PROVE PROPER OPERATION OF LIFERING BUOY WATER LIGHT.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Lifesaving
Issued 30 August 1989
Resolved
PROPERLY MARK ALL PFDS
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 23 May 1988
Resolved
PROVIDE BATTERY BOXES.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Electrical
Issued 23 May 1988
Resolved
PROVIDE A FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Fire Fighting
Issued 23 May 1988
Resolved
PROVIDE ONE BII FIRE EXTINGUISHER.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Electrical
Issued 23 May 1988
Resolved
PROPERLY SPLICE WIRE FOR NAVIGATION LIGHTS.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Documentation
Issued 23 May 1988
Resolved
PROVIDE EMERGENCY CHECK-OFF PROCEDURE.
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Documentation
Issued 9 June 1987
Resolved
MOVE FENDERS AWAY FROM STATE NUMBER DISPLAY AT BOW SO THAT NUMBERS MAY BE SEEN.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Engineering
Issued 9 June 1987
Resolved
RENEW THE TAILSHAFT.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Engineering
Issued 9 June 1987
Resolved
INSTALL METAL THROUGH HULL FITTING AND VALVE FOR BILGE PUMP DISCHARGE. PROVIDE 1" DISCHARGE HOSE FOR BILGE PUMP.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Engineering
Issued 9 June 1987
Resolved
REPLACE PLASTIC FUEL LINES WITH PROPER FLAME SHIELDED STEEL WIRE REINFORCEDOR COPPER LINES.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Electrical
Issued 9 June 1987
Resolved
REMOVE WIRE NUTS AND MAKE SPLICES PROPERLY IN ELECTRICAL SYSTEM.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Engineering
Issued 9 June 1987
Resolved
INSTALL PROPER SIZE VEE BELT ON ENGINE ALTERNATOR AND WATER PUMP.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Electrical
Issued 9 June 1987
Resolved
REPLACE MAIN DISCONNECT SWITCH FOR FEEDER FROM BATTERY.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Electrical
Issued 9 June 1987
Resolved
PROVIDE OVER CURRENT PROTECTION FOR MAIN FEEDER TO PANEL BOARD FROM STARTERSOLENOID TERMINAL.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Navigation
Issued 9 June 1987
Resolved
RESECURE LOWER END OF HELM TILLER TO DECK.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Accommodation/Occupational Safety
Issued 9 June 1987
Resolved
RESECURE HANDRAIL AT GANGWAY.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987