← All vessels
RELIANCE II
Freight Ship · Ro-Ro Cargo Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named RELIANCE II
RELIANCE II is a 1999 freight ship. The Coast Guard has recorded 29 inspections since 1999, most recently in January 2026, along with 41 deficiencies and 5 operational controls.
Records from 1999 to 2026. Most recent: inspection, 26 January 2026.
- Built
- 1999
- Last inspected
- 26 January 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 41 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9221322 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
5VHS7
506897
Flag
TOGO
—
Maury page id
psix-506897
Inspections, by type
…with no type recorded3
Years with a record
15 calendar years (1999–2026)
The 29 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it498 - Convention (Subpart B), Gross Ton
498 - Regulatory (Subpart C or D), Gross Ton
149 - Convention (Subpart B), Net Ton
149 - Regulatory (Subpart C or D), Net Ton
498 - Regulatory (Subpart C or D), Gross Ton
149 - Convention (Subpart B), Net Ton
149 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 29
26 January 2026
CCSSC Examination · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8301612
28 August 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8219972
25 July 2025
PSC A · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8194206
23 January 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8067542
18 July 2024
PSC A · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7957720
18 January 2024
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7849866
5 July 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7733738
20 May 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7692658
15 May 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7688913
3 October 2022
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7570290
23 March 2022
PSC A · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7416529
17 February 2022
Ballast Water Examination · PSC A · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7397658
10 January 2022
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7377902
18 November 2021
PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7347142
27 September 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6821831
14 December 2018
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6596996
7 June 2018
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6436635
4 May 2018
CCSSC Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6373810
21 July 2011
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4089240
4 March 2007
ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2881396
8 August 2004
ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2159617
9 June 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2093418
2 April 2003
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1766967
14 March 2003
Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1757265
11 September 2002
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1674285
26 July 2002
Deficiency Check · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1652297
11 August 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 292716
27 February 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 293096
29 November 1999
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435184
Deficiency record · 41
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 7 July 2023
Resolved
Each survival craft shall be stowed: in a state of continuous readiness. Rescue boat engine was unable to start.
CCSS Code 4.9.2.3
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 24 March 2022
Resolved
The ring, lines and letters shall be... permanently marked on the sides of the ships to the satisfaction of the administration. Load line markings were not permanently affixed/marked on the hull.
ICLL 66/88 Annex 1 Reg 8
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 17 February 2022
Resolved
Oil filtering equipment...shall be of a design approved by the administration and shall be such as will ensure any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15ppm. MARPOL 1/14.6
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 17 February 2022
Resolved
The emergency fire pump shall be capable of producing at least a jet of water of not less than 6m in any condition and state of trim of the vessel, from one hydrant and hose through a nozzle complying with the requirements of 3.5.11.1.
CCSSC CHAP. 3.3.7.2
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 17 February 2022
Resolved
OIL FILTERING EQUIPMENT REFERRED TO IN PARAGRAPH 1 OF THIS REGULATION SHALL BE OF A DESIGN APPROVED BY THE ADMINISTRATION AND SHALL BE SUCH AS WILL ENSURE ANY OILY MIXTURE DISCHARGED INTO THE SEA AFTER PASSING THROUGH THE SYSTEM HAS AN OIL CONTENT METER NOT EXCEEDING 15 PPM.OIL FILTERING ARRANGEMENT DID NOT INCLUDE AN AUTOMATICALLY CLOSING THREEWAY VALVE OR AN ALARM DEVICE PRE-SET TO 15PPM. THE VALVE WAS NOT ARRANGED TO AUTOMATICALLY CLOSE AND/OR AN ALARMING DEVICE WAS NOT PRESENT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2021
Resolved
In ships of 50m in length and over at least two lifebuoys should be provided with self activating smoke signals. The vessel is missing one due to past expiration.
ccss code 4.12.3
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 18 November 2021
Resolved
An emergency fire pump shall be permanently connected to the fire mains. the use of portable fire pumps shall be avoided. Emergency fire pump is not permanently connected to the fire mains.
ccss code 3.3.10.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 November 2021
Resolved
A main source of electrical power of sufficient capacity shall be provided. Port generator is not operational.
ccss code 2.28.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2021
Resolved
The owner of every ship shall ensure that the condition of the ship and its equipment to conform with the provision of this code will remain fit to proceed to sea without danger to persons on board. Starboard main has an exhaust leak.
ccss 1.11.1
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 4 May 2018
Resolved
0715-Detection-The condition of the ship and its equipment is maintained to conform with the provisions of this code. There are no means to test the operation of the fire detection system in the engine room. CSSCC 1.11.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 4 May 2018
Resolved
0750-Fire Dampers Remote Control, etc.-When bulkheads are penetrated for the passage of cables, arangements shall be made to ensure that the fire integrity is not impaired. There are penetrations in the engineroom bulkhead that do not prevent the passage of fire. CCSSC 3.19.1.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 4 May 2018
Resolved
0750-Fire Prevention-When bulkheads are penetrated for the passage of ventilation, arangements shall be made to ensure that the fire integrity is not impaired. There are penetrations around the exhaust fan on the stack that do not prevent the passage of fire. CCSSC 3.19.1.
Communications › Radio Communications › EPIRB
Issued 4 May 2018
Resolved
Hydrostatic release units other than disposable units shall be serviced at intervals not exceeding 12 months. Hydrostatic release for EPIRB had not been serviced for over 12 months. CCSSC 4.8.1.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 May 2018
Resolved
0699-Other (Life Saving Appliances)-The condition of the ship and its equipment is maintained to conform with the provisions of this code. There were expired batteries on two portable VHF radios. CSSCC 1.11.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 4 May 2018
Resolved
Vessel failed to make required Ballast Water Report to NBIC prior to its' arrival to Jacksonville.
Lifesaving › Lifebuoys › Stowage
Issued 4 March 2007
Resolved
Vessel does not have rapid release system for the bridge wing life buoys.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 4 March 2007
Resolved
Vessel does not have a valid safety radio certificate and shore based maintence is expired for the GMDSS
Documentation › Certificates/Documents › IOPP Certificate
Issued 4 March 2007
Resolved
IOPP certificate was not issued to vessel. Flag state surveyor issued exemption to the vessel stating that they were not required an IOPP certificate. MARPOL 73/78 Annex I Regulation 5 States that an IOPP certificate shall be issued, to any oil tanker of 150 gross tons or any other ship of 400 gross tons and above. The vessel is 498 gross tons.
Documentation › Certificates/Documents › Special Purpose Ship Safety Certificate
Issued 4 March 2007
Resolved
Vessel is missing Carribean Cargo ship safety certificate. (CCSSC)
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 4 March 2007
Resolved
Vessel is missing all original documents issued to the vessel. Copies were not sufficient. Vessels master claimed that the original documents had gotten wet.
Fire Fighting › Combustible Materials
Issued 14 March 2003
Resolved
Remove paints/solvents from fwd stbd locker & stow in paint locker. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Fire Fighting › Miscellaneous Items
Issued 14 March 2003
Resolved
Provide spanner wrenches for all fire stations.
Engineering › Fuel Oil Storage/Transfer System
Issued 14 March 2003
Resolved
Provide guards for all sight glass gauges. LEGACY COMPONENT DESC: Tank
Navigation › Piloting/Steering
Issued 14 March 2003
Resolved
Provide current Coast Pilot and Light List. LEGACY COMPONENT DESC: Coast Guard Light List
Pollution Prevention/Response › Prevention Equipment
Issued 14 March 2003
Resolved
Secure MSD overboard discharge valve. LEGACY COMPONENT DESC: Sewage System Valve
Deck/Cargo › Cargo Stowage
Issued 27 July 2002
Resolved
Offload Hazardous cargo or provide dangerous cargo manifest and proof of crew training in HAZMAT prior to departure. LEGACY COMPONENT DESC: HAZMAT
Accommodation/Occupational Safety › Occupational Safety
Issued 26 July 2002
Resolved
Remove materials in bilge located in emergency escape passageway.
Pollution Prevention/Response › Prevention Equipment
Issued 26 July 2002
Resolved
Install positive control valve on OWS discharge line/pipe. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Documentation › Markings/Placards › Oil Discharge Placard
Issued 26 July 2002
Resolved
Provide oil discharge placard.
Fire Fighting › International Shore Connection
Issued 26 July 2002
Resolved
Address location of International Shore Connection and install according to Fire Control Plan.
Navigation › Piloting/Steering
Issued 26 July 2002
Resolved
Provide navigational chart for Port Everglades, FL. LEGACY COMPONENT DESC: Marine Charts
Navigation › Piloting/Steering
Issued 26 July 2002
Resolved
Update deviation table. Table has not been updated since 1999. LEGACY COMPONENT DESC: Compass Deviation Table
Documentation › Manuals/Policy Documentation
Issued 26 July 2002
Resolved
Provide instructions for maintanence and operations of all installations/equipment for fire fighting and containment of fire in accordance with CCSSC 3.13.3.
Lifesaving › Buoyant Smoke Signals
Issued 26 July 2002
Resolved
Provide new smoke signal for stbd bridge lifebuoy.
Documentation › Safety/Response Plans/Programs
Issued 26 July 2002
Resolved
Update Fire Control Plan to accurately reflect layout of vessel and equipment onboard in accordance with CCSSC 3.13. LEGACY COMPONENT DESC: Fire Control Plans
Electrical › Lighting (service)
Issued 26 July 2002
Resolved
Provide cover for open lights in forward storage lockers. LEGACY COMPONENT DESC: Lighting Fixture
Pollution Prevention/Response › Prevention Equipment
Issued 26 July 2002
Resolved
Install standard discharge connection in accordance with 33CFR 155.430. LEGACY COMPONENT DESC: Standard Discharge Connection
Deck/Cargo
Issued 11 August 2001
Resolved
Prior to departure prove all fuel has been removed from all vehicles on board.
Documentation
Issued 11 August 2001
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 29 November 1999
Resolved
Provide copies of all pertinent certificates, including CCSS, COFR, ITC, prior to entry to territorial waters of U.S.
Documentation
Issued 29 November 1999
Resolved
Vsl to pass USCG CCSS examination prior to loading/offloading cargo in U.S.port.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National