L.Y.C. III is a 1972 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1985, most recently in April 2025, along with 65 deficiencies and 1 operational control.

Records from 1985 to 2025. Most recent: inspection, 25 April 2025.

Built
1972
Last inspected
25 April 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-50699

Inspections, by type

…with no type recorded6
Years with a record 36 calendar years (1985–2025)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

25 April 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8119893
20 May 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7914249
18 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897071
28 April 2023 Deficiency Check · Re-Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7638204
14 April 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7668563
28 April 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7439901
8 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7427293
14 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7196990
8 July 2020 DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7008082
17 June 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6979625
20 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956513
11 April 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6697149
13 April 2018 Hull Examination · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6390582
24 May 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6153661
4 May 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5868935
8 April 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5849788
25 March 2014 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4823232
4 June 2012 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4333252
5 December 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4201706
3 September 2010 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3841177
25 March 2008 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3170814
26 April 2006 MARPOL Annex V Examination · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2634062
28 March 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2611248
18 April 2005 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2336230
29 March 2004 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2032994
29 April 2003 Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1770500
5 April 2002 Hull Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1601667
2 April 2001 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1406902
13 April 2000 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 819315
30 March 2000 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1379009
5 April 1999 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1393128
24 February 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 800385
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787477
31 March 1998 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 788657
29 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1091381
8 April 1996 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1080929
19 April 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1169980
18 April 1994 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859990
10 May 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842271
12 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145140
20 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953084
3 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956459
2 April 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957749
9 July 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927119
14 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 896655
15 March 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1042032
10 September 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005173
28 July 1987 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028436
6 August 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309392
30 July 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309389
28 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 984629
5 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288630

Deficiency record · 65

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2025 Resolved
"Life preservers for children shall be stored separately."MI identified both adult and child life jackets together. Address the separation of life jackets. 46 CFR 180.25-10(c) "OLD T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Received satisafactory photographic evidence. Locate under "Documents" tab.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2025 Resolved
"A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI..." Vessel is missing 01 fire bucket. Ensure 03 buckets onboard. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2025
Resolution: Locate photographic correction under "Documents" tab.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 April 2025 Resolved
"All vessels must have navigation lights." Vessel's stern light was inoperable. Ensure light is operable. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2025
Resolution: Locate photographic correction under "Documents" tab.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 April 2025 Resolved
"A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions..." Vessel had expired medicine in first-aid kit. Ensure vessel has adequate first-aid kit with satisfactory contents. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2025
Resolution: Locate photographic correction under "Documents" tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2024 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: (1) Be buoyant; (2) Be of at least 18.3 meters (60 feet) in length; (3) Be non-kinking; (4) Have a diameter of at least 7.9 millimeters (5/16 inch); (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and (6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Lifeline fitted to vessels ring life buoy is less than 60 feet. Vessel shall replace with proper lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 27 May 2024
Resolution: Vessel replaced lifeline on ring buoy. This deficiency has been resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2024 Resolved
While performing inspection of the steering gear, a grounding wire was found broken off of the rudder post. Vessel replaced connection on the spot. This deficiency has been resolved.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2024
Resolution: )While performing inspection of the steering gear, a grounding wire was found broken off of the rudder post. Vessel replaced connection on the spot. This deficiency has been resolved.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: a) Operation of the main propulsion machinery both ahead and astern; (b) Operational test and inspection of engine control mechanisms including primary and alternate means of starting machinery. Prior to carriage of passengers conduct satisfactory propulsion and pre-engineered fire system engine shut off tests. 46 CFR 176.804
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2023
Resolution: Op tested engine and tested fireboy engine shutdown and override. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Conduct man overboard recovery drill with minimum required manning prior to carriage of passengers. 46 CFR 176.808
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2023
Resolution: Conducted satisfactory MOB drill with just master. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 April 2019 Resolved
Vessel failed testing of the pre-engineered fire extinguishing sytem. Service equipment and provide proof of proper operation of pre-engineered fire extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2019
Resolution: Operator provide video proof of proper operation and testing of system.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 13 April 2018 Resolved
Prove proper operation of fireboy system, to include engine shutdown and override.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Verified proper operation of the fireboy, to include the override function.
Engineering › Bilge Water Management System › Not Installed
Issued 24 May 2017 Resolved
veseel does not have visual bilge alarm at operating station.
Condition: Design Flaw
Due 29 June 2017
Resolved 29 June 2017
Resolution: vessel installed an indicator lighjt at operating station
Engineering › Bilge Water Management System › Pump
Issued 24 May 2017 Resolved
vessel did not have pump indicator when the bilge pump is running
Condition: Design Flaw
Due 29 June 2017
Resolved 29 June 2017
Resolution: vessel installed indicator to let operator know when pump is running.
Navigation › Piloting/Steering › Marine Charts
Issued 4 June 2012 Resolved
PF01: Vessel must provide up to date charts. Due 12Ju2012
Action required: 705 - Other - as specified
Resolved 1 July 2012
Resolution: Received a letter from the master stating the proper up to date chart is onboard.
Navigation › Piloting/Steering › US Coast Pilot
Issued 4 June 2012 Resolved
PF02: Vessel must have Coast Pilot onboard. Due 12Ju2012
Action required: 705 - Other - as specified
Resolved 1 July 2012
Resolution: Received a letter from the master stating Coast Pilots is onboard.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 June 2012 Resolved
PF03: Provide a document folder for each vessel to keep onboard. Due 12Ju2012
Action required: 705 - Other - as specified
Resolved 14 June 2012
Resolution: Attended vessel verified vessel had a document folder onboard
Documentation › Certificates/Documents › Stability Letter
Issued 5 December 2011 Resolved
Owner/Operator failed to submit stability certification compliance by 01DEC11. Issued CG-835 reducing maximum persons allowed to 16 based on the assumed average weight per person of 185 pounds and in accordance with 46 CFR 178.320 amended by FR vol. 75, No. 239, USCG-2007-0030. Reduction will remain in effect until Owner/Operator submits stability certification compliance to Coast Guard.
Action required: 705 - Other - as specified
Resolved 5 April 2012
Resolution: Drafted stability letter.
Communications › Audible Communications › Horn/Whistle
Issued 4 April 2006 Resolved
Provide signalling horn
Due 1 May 2006
Resolved 26 April 2006
Resolution: Air horn provided.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 April 2006 Resolved
Provide 01 life jacket to replace non-serviceable one as discussed.
Due 1 May 2006
Resolved 26 April 2006
Resolution: Provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 April 2006 Resolved
Prover operation of navigation lights.
Due 1 May 2006
Resolved 26 April 2006
Resolution: All lights working.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 April 2006 Resolved
Repair holes in engine space ventilation tube.
Due 1 May 2006
Resolved 26 April 2006
Resolution: New ventilation tubing installed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 4 April 2006 Resolved
Provide firefighting servicing certificates.
Due 1 May 2006
Resolved 26 April 2006
Resolution: Serviced April 2006.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 18 April 2005 Resolved
Secure stern tube leak. Stern tube currently leaks steady stream of water while vessel is operating.
Due 25 April 2005
Resolved 21 April 2005
Resolution: Mechanic tightened stern tube, and reduced leak to a safe drip. Cleared via fax.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 18 April 2005 Resolved
Replace bracket on BI fire extinguisher.
Due 25 April 2005
Resolved 21 April 2005
Resolution: Bracket on helm extinguisher replaced. Cleared via fax.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2005 Resolved
Replace lifeline on ring buoy w/ 60' of sun resistant line.
Due 25 April 2005
Resolved 21 April 2005
Resolution: Poly-line on lifering replaced with 60'''' of new UV resistant line. Cleared via fax.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 March 2004 Resolved
Post emergency instructions as required by 46CFR185.510.
Due 31 May 2004
Resolved 17 June 2004
Resolution: [name withheld], Director of Marine Facilities, attested by fax that instructions have been posted.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 29 March 2004 Resolved
Paint hailing port on hull.
Due 31 May 2004
Resolved 17 June 2004
Resolution: Vessel < 5 GT and does not need to meet 46CFR67.120 general requirements for vessel hull documentation.
Lifesaving › Lifebuoys
Issued 29 April 2003 Resolved
Replace Life Ring Buoy LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2003
Documentation › Certificates/Documents
Issued 29 April 2003 Resolved
Post COI LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Improper/Lack of Maintenance
Due 6 May 2003
Resolved 8 May 2003
Resolution: COI made available.
Accommodation/Occupational Safety › Occupational Safety
Issued 29 April 2003 Resolved
Tighten hand rail fwd of control station. LEGACY COMPONENT DESC: Hand Grab
Condition: Improper/Lack of Maintenance
Due 6 May 2003
Resolved 15 May 2003
Resolution: Received digital photos showing structural reinforcement of fwd hand rails.
Lifesaving › Lifejacket/PFD (General)
Issued 29 April 2003 Resolved
Post Lifejacket donning placard. LEGACY COMPONENT DESC: Lifejacket Donning Placard
Condition: Improper/Lack of Maintenance
Due 6 May 2003
Resolved 29 April 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 April 2003 Resolved
Replace First Aid Kit with one approved under 46 CFR 160.041 LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 6 May 2003
Resolved 15 May 2003
Resolution: Received receipt for CG approved first aid kit.
Fire Fighting › Miscellaneous Items
Issued 29 April 2003 Resolved
Add two additional Fire Fighting Buckets or add one portable hand pump of at least 5gpm.
Due 6 May 2003
Resolved 8 May 2003
Resolution: Hand pump added.
Engineering › Sea-water System (primary cooling)
Issued 29 April 2003 Resolved
Place two clamps on all vital system piping. (Raw water suction) LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 6 May 2003
Resolved 15 May 2003
Resolution: Received digital photos showing all double hose clamping required.
Engineering › Bilge Water Management System
Issued 29 April 2003 Resolved
Need one portable hand pump of at least 5gpm. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 6 May 2003
Resolved 8 May 2003
Resolution: Hand pump added.
Operations/Management › Pollution
Issued 29 April 2003 Resolved
Post MARPOL V placard. LEGACY COMPONENT DESC: Garbage Placard
Condition: Unknown
Due 6 May 2003
Resolved 8 May 2003
Resolution: Placard posted.
Operations/Management › Drills/Instruction
Issued 29 April 2003 Resolved
Post Emergency Broadcast placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Condition: Unknown
Due 6 May 2003
Resolved 8 May 2003
Resolution: Instructions posted.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 5 April 2002 Resolved
Affix proper vessel name to transom.
Condition: Placed in Improper Service
Due 16 April 2002
Resolved 5 April 2002
Resolution: Received fax confirmation from O/O indicating compliance.
Engineering › Fuel Oil Storage/Transfer System
Issued 3 April 2002 Resolved
Replace fuel tank vent screen with 30x30 mesh. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 16 April 2002
Resolved 5 April 2002
Resolution: Received fax confirmation from O/O indicating compliance.
Lifesaving
Issued 30 March 2000 Resolved
Renew retroreflective tape on 10 adult sized life jackets.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Documentation
Issued 30 March 2000 Resolved
Provide copy of current drug testing contract.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Fire Fighting
Issued 30 March 2000 Resolved
Provide hydrostatic testing for BII portable CO2 fire extinguisher.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Documentation
Issued 30 March 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Navigation
Issued 30 March 2000 Resolved
Provide emergency steering system.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Construction/Loadline
Issued 30 March 2000 Resolved
Provide valve at hull penetration for the installed hand bilge pump overboard discharge.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Fire Fighting
Issued 30 March 2000 Resolved
Provide a hand fire pump or three - 2 1/2 gallon fire buckets.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Engineering
Issued 30 March 2000 Resolved
Renew improper fuel hose with hose rated SAE J-1942.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Fire Fighting
Issued 30 March 2000 Resolved
Renew safety pin for manual pull handle. Pin is corroded to the point of rendering the pull handle unusable.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Construction/Loadline
Issued 30 March 2000 Resolved
Renew improper bilge piping/hose with hose rated SAE J-1942, and place valve at hull penetration.
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Fire Fighting
Issued 22 January 1999 Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Fire Fighting
Issued 22 January 1999 Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Fire Fighting
Issued 22 January 1999 Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Fire Fighting
Issued 8 April 1996 Resolved
RECHARGE BI PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 1 May 1996
Resolved 18 July 1996
Engineering
Issued 8 April 1996 Resolved
MARK LOCATION OF FUEL SHUT OFF VALVE.
Condition: Unknown
Due 1 May 1996
Resolved 18 July 1996
Engineering
Issued 12 April 1993 Resolved
PROVE PROPER OPERATION OF MAIN DIESEL ENGINE. DO NOT OPERATE WITH PASSENGERS UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Unknown
Issued 28 July 1987 Resolved
PROVIDE ONE VENT TO BOTTOM OF VESSEL IN COMPLIANCE WITH 46 CFR 182.20-45.50
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987 Resolved
PROVIDE MOUNT FOR RING BUOY.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Fire Fighting
Issued 28 July 1987 Resolved
PROVIDE VALVES AT HULL ON ALL BILGE OVERBOARD LINES.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Lifesaving
Issued 28 July 1987 Resolved
PROVIDE LIGHT FOR RING BUOY PRIOR TO OPERATING AT NIGHT.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Electrical
Issued 28 July 1987 Resolved
REMOVE DEAD END CABLE ON BATTERY.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Documentation
Issued 28 July 1987 Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Electrical
Issued 28 July 1987 Resolved
PROVIDE PROPER BATTERY BOX.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Engineering
Issued 28 July 1987 Resolved
PROVIDE FLAME SHIELD FOR RAYCOR FUEL FILTER.
Condition: Unknown
Due 28 July 1987
Resolved 28 July 1987
Unknown
Issued 6 August 1986 Resolved
PROVIDE ONE VENT TO BOTTOM OF VESSEL IN COMPLIANCE WITH 46 CFR 182.20-45.50
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986
Engineering
Issued 6 August 1986 Resolved
PROVIDE APPROVED FUEL LINE IN COMPLIANCE WITH 46 CFR 182.20-40.
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986
Construction/Loadline
Issued 28 June 1985 Resolved
INSTALL VENTILATION DUCT TO BILGE LEVEL IN BOTH ENGINE AND FUEL COMPART- MENTS. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTORY OF A COAST GUARD INSPECTOR NOT LATER THAN 15 JULY 1985.
Condition: Unknown
Due 28 June 1985
Resolved 28 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.