MAURY USCG vessel records
← All vessels

L.Y.C. III

L.Y.C. III is a 1972 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in April 2025, along with 12 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 25 April 2025.

Built
1972
Last inspected
25 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-50699

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

25 April 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8119893
20 May 2024 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7914249
18 April 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897071
28 April 2023 Deficiency Check · Re-Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7638204
14 April 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7668563
28 April 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7439901
8 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7427293
14 May 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7196990
8 July 2020 DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7008082
17 June 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6979625
20 May 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6956513
11 April 2019 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6697149
13 April 2018 Hull Examination · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6390582
24 May 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6153661
4 May 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5868935
8 April 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5849788

Deficiency record · 12

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 April 2025 Resolved
"Life preservers for children shall be stored separately."MI identified both adult and child life jackets together. Address the separation of life jackets. 46 CFR 180.25-10(c) "OLD T"
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Received satisafactory photographic evidence. Locate under "Documents" tab.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 April 2025 Resolved
"A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI..." Vessel is missing 01 fire bucket. Ensure 03 buckets onboard. 46 CFR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2025
Resolution: Locate photographic correction under "Documents" tab.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 April 2025 Resolved
"All vessels must have navigation lights." Vessel's stern light was inoperable. Ensure light is operable. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2025
Resolution: Locate photographic correction under "Documents" tab.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 April 2025 Resolved
"A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions..." Vessel had expired medicine in first-aid kit. Ensure vessel has adequate first-aid kit with satisfactory contents. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2025
Resolution: Locate photographic correction under "Documents" tab.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 May 2024 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: (1) Be buoyant; (2) Be of at least 18.3 meters (60 feet) in length; (3) Be non-kinking; (4) Have a diameter of at least 7.9 millimeters (5/16 inch); (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and (6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Lifeline fitted to vessels ring life buoy is less than 60 feet. Vessel shall replace with proper lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2024
Resolved 27 May 2024
Resolution: Vessel replaced lifeline on ring buoy. This deficiency has been resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2024 Resolved
While performing inspection of the steering gear, a grounding wire was found broken off of the rudder post. Vessel replaced connection on the spot. This deficiency has been resolved.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2024
Resolution: )While performing inspection of the steering gear, a grounding wire was found broken off of the rudder post. Vessel replaced connection on the spot. This deficiency has been resolved.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: a) Operation of the main propulsion machinery both ahead and astern; (b) Operational test and inspection of engine control mechanisms including primary and alternate means of starting machinery. Prior to carriage of passengers conduct satisfactory propulsion and pre-engineered fire system engine shut off tests. 46 CFR 176.804
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2023
Resolution: Op tested engine and tested fireboy engine shutdown and override. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 April 2023 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Conduct man overboard recovery drill with minimum required manning prior to carriage of passengers. 46 CFR 176.808
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2023
Resolution: Conducted satisfactory MOB drill with just master. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 11 April 2019 Resolved
Vessel failed testing of the pre-engineered fire extinguishing sytem. Service equipment and provide proof of proper operation of pre-engineered fire extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2019
Resolution: Operator provide video proof of proper operation and testing of system.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 13 April 2018 Resolved
Prove proper operation of fireboy system, to include engine shutdown and override.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2018
Resolution: Verified proper operation of the fireboy, to include the override function.
Engineering › Bilge Water Management System › Not Installed
Issued 24 May 2017 Resolved
veseel does not have visual bilge alarm at operating station.
Condition: Design Flaw
Due 29 June 2017
Resolved 29 June 2017
Resolution: vessel installed an indicator lighjt at operating station
Engineering › Bilge Water Management System › Pump
Issued 24 May 2017 Resolved
vessel did not have pump indicator when the bilge pump is running
Condition: Design Flaw
Due 29 June 2017
Resolved 29 June 2017
Resolution: vessel installed indicator to let operator know when pump is running.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.